Page 1: Broomhill Tennis Club - DC Lighting Services Ltd Tennis Club Project...Broomhill Tennis Club DC Lighting Services Ltd Date: ... Lower Centre Columns Lower Left Columns ... Philips

Broomhill Tennis Club DC Lighting Services LtdDate: 27-01-2011

2. Summary

2.1 General Information

The overall maintenance factor used for this project is 0.80.

2.2 Project Luminaires

Code

A

QtyQty

4

Luminaire TypeLuminaire Type

MVP507 WB/60

Lamp TypeLamp Type1 * MHN-LA2000W/400V/842/842

Power (W)Power (W)

2123.0

Flux (lm)Flux (lm)

1 * 220000

The total installed power: 8.49 (kWatt)

Number of Luminaires Per Arrangement:

Arrangement

Lower Centre ColumnsLower Left ColumnsLower Right ColumnsUpper Centre ColumnsUpper Centre Columns1Upper Corner ColumnUpper Left Side CornerUpper Right Corner farUpper left Side Corner

LuminaireCode

A220000000

Power (kWatt)Power (kWatt)

4.25 4.25 0.00 0.00 0.00 0.00 0.00 0.00 0.00

2.3 Calculation Results

(Il)luminance Calculations:CalculationLower Left Court

TypeTypeSurface Illuminance

UnitUnitlux

AveAve 600

Min/AveMin/Ave0.84

Min/MaxMin/Max0.75

Philips Lighting B.V. - CalcuLuX Area 7.6.1.0 Page: 5/8