POWER SYSTEMS 1-11 kVA50 Hz - 3000 rpm

Peter
for more information please contact:- Generator Associates Ltd tel 01623 624 005 [email protected] - www.generatorassociates.com
Page 2: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

3

PRAMAC GROUPPRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

dynamic growth and a strong presence across the globe.

Power Engineering

Gensets from 6 to 2500kVa in standard and customised versions.

Handling Systems

Hand pallet trucks, electric pallet trucks, high lift pallet trucks and stackers.

Service and Parts

A full line of spare parts and accessories for all PRAMAC products and a worldwide dedicated after sales service organization.

POWER SYSTEMSThis Division of the PRAMAC Group offers a wide range of generator sets, welder generators, water

pumps and pressure washers. Quality, efficiency and high product standards are achieved through the

use of modern design and manufacturing techniques, exceeding international regulations for noise and

environmental pollution. The safety and reliability enhances this vast product range that meets the needs

of professional and amateur users alike.

Our commitment to quality and design is supported by ISO9001 certification we achieved many years

ago. We have also been able to exceed the latest international safety directives and rules; Directive

98/37/CE, Directive 2000/14/EC, Emissions according to EPA (Environmental Protection Agency), CARB

(California Air Resources Board) – offering the user a total warranty for their safety, product reliability

and service.

Challenges and Competition: The desire to always take part with the aim of succeeding.

These are the ideals that the young PRAMAC team represents.

PRAMAC has a close relationship with Honda, a relationship that through the racing team is the perfect

combination of technology, quality and success.

C O N T E N T S

The Range ............................................................. 4Why PRAMAC? .......................................... 6What is ......................................................................... 9Glossary of terms ................................ 13The directive 2000/14/EC ..............................................................................................................................14Model codes .................................................... 15How to select a generator ... 16

Generator setsE CLASS ................................................... 20ES CLASS ............................................... 26S CLASS .................................................... 28C CLASS .................................................... 36P CLASS ................................................... 40

Welder generatorsW CLASS ................................................. 52WP CLASS ............................................ 54

PTO generatorsZG CLASS .............................................. 58

High pressure washers HP CLASS ................................................ 62

Motor pumps MP CLASS .............................................. 66

Accessories and options ........ 70

Service & Parts ...................................... 74

Peter
for more information please contact:- Generator Associates Ltd tel 01623 624 005 [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd tel 01623 624 005 [email protected] - www.generatorassociates.com
Peter
Page 3: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

4 5

GRUPPI ELETTROGENI SERIE E

GRUPPI ELETTROGENI SERIE ES

GRUPPI ELETTROGENI SERIE S

GRUPPI ELETTROGENI SERIE P

GRUPPI ELETTROGENI SERIE C

MOTOSALDATRICI SERIE W

MOTOSALDATRICI SERIE WP

GRUPPI TRATTORE SERIE ZG

MOTOPOMPE SERIE MP

IDROPULITRICI SERIE HP

POWER SYSTEMS RANGE

The range usually found in professional applications on bui-lding sites or by hobbyists and domestic users looking for a robust, practical, reliable and cost efficient temporary power source.

GENERATORS E CLASS

The ideal generators for professional and intensive appli-cations. These generators are an excellent combination of efficiency, endurance and performance.

GENERATORS ES CLASS

Professional generators that are fully equipped and robust. With high performance and reliability, these generators are perfectly suited to the most demanding applications.

GENERATORS S CLASS

The most up to date technology, top level equipment and manufacturing quality makes this line of generators a top performer in almost any application.

GENERATORS P CLASS

A range of Welder Generators; from 170A to 400A, with mechanical or electronic current regulation. The PRAMAC range of welder generators are reliable, strong and efficient – suitable for craftsman and exigent specialists alike.

WELDER GENERATORS W CLASS

Balancing functionality, practicality and performance – these generators are ideal for domestic and hobby applications. They are all straightforward to use, reliable and efficient.

GENERATORS C CLASS

This new ‘Protech’ welder range (180A to 230A) offer all the characteristics and performances of the ‘W’ class along with a larger fuel tank capacity allowing a longer run time for more demanding professional use.

WELDER GENERATORS WP CLASS

PTO generators are a safe, constant and versatile power source, able to generate low cost efficient power for agricul-tural applications.

PTO GENERATORS ZG CLASS

Reliable and strong motor pumps suitable for any kind of application professional or domestic.

MOTOR PUMPS MP CLASS

Petrol or Diesel driven cold water high pressure washers, suitable for all applications where efficiency and power are a necessity.

HIGH PRESSURE WASHERS HP CLASS

P. 20

P. 26

P. 28

P. 40

P. 36

P. 52

P. 56

P. 60

P. 68

P. 64

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 4: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

6 7

3 - Affidabili per ogni utilizzo

LA TECNOLOGIA INVERTER

1 - Risparmi e prestazioni 2 - Dimensioni e peso ridotti

7 - Applicazioni e utenze

4 - UPS

5 - Pannelli fotovoltaici 6 - Connessione alla rete

COMPUTER

RADIO

VIDEO

TV

AIR COMPRESSORS

FAX

WELDERS SUBMERSIBLE PUMPS

NEONLIGHTS

The high reliability and quality of the electrical

energy produced from this system means the

generator can be used to power all types of

electronic equipment such as computers,

electromedical equipment, electronic instruments,

highfrequency equipments and many other devices

highly sensitive to variations in voltage and

frequency. Stable voltage and frequencyIn any working condition

3 - Reliable for any kind of use

WHY PRAMAC?Through constant research we find innovative solutions

Through constant research at PRAMAC Group’s R&D

department, the first PRAMAC generator with inverter

technology has been developed. This new technology

makes it possible to produce a consistent power

output, independent of the load or the speed of the

engine. This is made possible by using an electronic

converter (inverter) that separates the correlation of

the input and output voltage. The alternator, unlike

a traditional type, has a permanent magnetic current

and works with an electronic device that monitors

and controls the speed of the engine, maintaining the

speed at a low level when there is no power demand

and increasing it according to requested power.

Reduced

noise

Improved

consumption

INVERTER TECHNOLOGY

1 - Saving and performances 2 - Reduced dimensions and weight

Generator with UPS are ideal for all applications that requiring highly stable voltage and frequency

i.e. computerised systems, medical and telecommunication equipment, also for the starting of any

machine requiring a strong start-up current (e.g. pumps, compressors etc.)

7 - Applications and uses

Designed exclusively for the PRAMAC generator with inverter technology, this

UPS is able to supply the highest quality reliable electrical voltage. The UPS

is automatically activated without interruption when the generator is switched

off, supplying a continuous power output as part of this mobile unit.

4 - UPS

5 - Solar panelPhotovoltaic cells are an alternative power source to

recharge the batteries of UPS when the generator

cannot be used. A silent system with zero running

costs. This incorporates a renewable energy source with

the most up to date technology, making this machine

uniquely reliable and environmentally friendly.

6 - Connection to the mains network With a dedicated cable it is also possible to

recharge the batteries of the UPS through the

mains electricity network. This solution allows you

to have power always available and ready to be

used. If for whatever reason power is lost, the UPS

will ensure your power is continuous and reliable.

WHY PRAMAC?Through constant research we find innovative solutions

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 5: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

8 9

Alternatore Motore

CAMERA SEMI-ANECOICA

UN GRANDE RISPETTO PER L’AMBIENTE E PER LA QUALITÀ

PRODUZIONE

WHAT IS A GENERATOR SET?

Alternator Engine

Fitted with IP23 protection and complying with safety requirements of directive 89/336 concerning electromagnetic compatibility.

Generators are available with unleaded petrol or diesel engines, with recoil or electric start, chosen from the most respected manufactures and brands in the world.

Sockets Frame/canopy

Fitted with Schuko, CEE or other types (according to model and power output), all fitted with IP44 protection.

Welded tubular or sheet steel; particularly strong and durable, treated with epoxy paint for a long lasting and resilient finish.

Used as an alternative power source for emergencies, industrial or domestic use where mains network

power is not available.

EmergencyAs a solution to interruptions in mains power supply and black-outs where a temporary lack of power

can be dangerous or inconvenient.

Industrial and DomesticGenerators are ideal for all professional, domestic and hobby applications where mains electricity is

not available.

Particular attention is given to the safety for the users of PRAMAC generators. IP44 protection fitted

to the sockets. IP23 protection fitted to the alternators; thermal, electromagnetic or differential

(according to model) electric protection to safeguard loads from overload or short circuit. The careful

selection of high quality components (engines, alternators, electric and electronic components)

assures the maximum performance in all situations. PRAMAC generators are available (according to

model) with recoil or electric start, and some models are available with an automatic mains failure

device in case of temporary cut in mains power supply.

To substantiate the attention and focus of our

company to the noise environmental impact of

our products, during 2002, a Semi-Anechoic

chamber was created, in collaboration with the

University of Florence, within our production

facility in Casole d’Elsa. This will allow us

to verify and certify that all PRAMAC Group

products follow all directives in force in terms

of noise.

SEMI ANECHOIC ROOM

The objective to exceed the needs of the end consumer can only be achieved if the quality

of the products offered is extremely high. The PRAMAC Group has taken this as a philosophy

in the production of its products. The continual improvement in the processes used by the

company, planned with absolute respect for the environment and the specialised training of

its staff, form part of the Total Quality program that the company has set. There is a real and

proper Quality Culture within the company, starting from respect for the environment and regard for specific

regulations concerning this area. Evidence of this commitment can be proven through the achievements and

certificate awarded to the company on both a European level and internationally further a field.

The same attention is given to all phases of production,

with tight and strict quality controls maintained at all

times. All generators are tested one by one at the end

of the assembly line before being carefully packed and

stored ready for delivery.

RESPECT FOR THE ENVIRONMENT AND DESIRE FOR QUALITY

PRODUCTION

WHY PRAMAC?Through constant research we find innovative solutions

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 6: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

10 11

Motore PompaAlternatore MotorePrese di tensione Engine Pump

Available with unleaded petrol and recoil start, chosen from the most reliable manufacturers and respected brands in the world.

Available as trash and clear water types, self priming and self cleaning.

Frame/canopy

Welded tubular or sheet steel; particularly strong and durable, treated with epoxy paint for a long lasting and resilient finish.

A motor pump can be used in all situations where it is necessary to move a great quantity of water in

effective and efficient way. Pumps are chosen by the application and location:

CLEAR WATER: For regular uses with clear water. Ideal for fish breeding, swimming pools and

similar.

TRASH: For intensive or emergency uses with clear or dirty water (with solid components such as

sand, mud, gravel, rubble etc.).

It is then necessary to determine the requested flow according to the use, and then the head. This

is the total height between the level of water to move up (distance between water and pump called

aspiration high cannot be more than eight metres) and the highest point where the same water will be

downloaded (distance between pump and the highest level is called height of flow).

We also need to consider possible leaks of load due to pipes, elbows, valves etc. that are reducing the

total head. To be able to chose the most suitable water pump for the application, it is useful to refer

to the diagram showing the curve of flow/pressure or total head. Flow is described as the intended

quantity of water moved, measured in m³/hour or litres/minutes, and total head described the height of

a theoretical vertical column of water the pump itself would be able to produce.

WHAT IS A MOTOR PUMP?

Alternator EngineSockets

Fitted with Schuko, CEE or other types (according to model and power output), all fitted with IP44 protection.

Asynchronous, all fitted with IP23 protection and complying the safety requirements of directive 89/336 concerning electromagnetic compatibility.

PRAMAC’s welder generators are available with unleaded petrol or Diesel engines with recoil or electric starting chosen from the most important brand at worldwide level.

Welding sockets Frame/canopy

Polarised, standard type in order to connect the electrode holders.

Welded tubular or sheet steel; particularly strong and durable, treated with epoxy paint for a long lasting and resilient finish.

WHAT IS A WELDER GENERATOR?A welder generator is based upon a standard generator, driven by a diesel or petrol engine, coupled with

an electric generator; set to produce AC electric power (using a single or three phase alternator) which is

then (some models use a rectifier) transformed to DC to produce high current, low voltage as required for

welding operations.

The most important change from a conventional generator is the use of an asynchronous alternator in

order to obtain the most suitable fluent energy with low voltage as this is the most important condition of

welding quality.

The AC output current is converted to DC using diodes and after that regulated to be used in welding with

the following systems:

• Through the control of engine speed

• Electronic adjustment through a rectifier diode bridge controlled by thiristors.

The first system, extremely simple, is used in the low power machines (up to 230A) while the second is

used for the professional applications (300, 350 e 400A) where higher currents are required.

Peter
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 7: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

12 13

Telaio Motore

GLOSSARY OF TERMS

Voltage: Potential difference between two points into an electric circuit. Is measured in Volt (V)

Current: Intensity of electrons crossing an electric circuit. Is measured in Ampere (A)

Resistance: Resistance existing in a circuit against the electron flow. Is measured in Ohm (Ω))

Power: Electric power generated or absorbed by an electric equipment in a certain time. Is measured

in Watt (W) or Volt-Ampere (VA) (see power factor)

Frequency: How many times an alternated current reverses its sense per second. Is measured in

Hertz (Hz)

Power factor: Relation between active power (W) and apparent power (VA). Shows the phase

difference between voltage and current and depending from the characteristics of equipments. Is a

pure number, indicated with cosfi.

Power factor is shown on the identification plate of the equipment.

Absorbed power can be calculated as follows:

Single phase W = V x A x cosϕ (power factor)

Three phase W = 3 x V x A x cosϕ (power factor)

SYMBOLS IN PRACTICE

HOW THE POWER OF OUR GENERATORS IS CALCULATED

W Active power supplied or absorbed by an electric equipment (1 kW = 1000 W)

VA Apparent power supplied or absorbed by an electric equipment (1 kVA = 1000 VA)

COP = Continuous power that a generator is able to supply

LTP = Maximum power that a generator is able to supply

To obtain the active power in W (or kW) it is necessary to multiply the value of cosϕ (power factor) by

the apparent power in VA (or kVA)

For a single phase voltage: 1000 VA x cosϕ 0,9 = 900 W – 1 kVA x cosϕ 0,9 = 0,9 kW

For a three phase voltage: 1000 VA x cosϕ 0,8 = 800 W – 1 kVA x cosϕ 0,8 = 0,8 kW

In case of cosϕ 1, values in VA and W are identical

IP DEGREES OF PROTECTION

According to the regulations EN 60529 and EN 60529/A1 defining the degree of protection of the

casing of electric equipments with a nominal voltage not exceeding 72,5 kV. The first two values

indicate: the first digit the degree of protection against external solid bodies and against the possible

access to dangerous parts. The second digit the level of protection against the penetration of liquids.

Examples: IP23 - IP44

A high pressure washer has the power to turn any water source into a high pressure water jet that can

be used for many applications. It can be used to clean and de-scale any type of dirt, car-washing,

workshops, agriculturally, food factories, site use; these are just examples of how useful these

machines can be.

Frame/canopy Engine

Welded tubular or sheet steel; particularly strong and durable, treated with epoxy paint for a long lasting and resilient finish.

Available with unleaded petrol and recoil start, chosen from the most reliable manufacturers and respected brands in the world.

Pump Accessories

Fitted with 3 ceramic pistons, with rod/crank system, double seal system on piston - particularly suitable for intensive and heavy duty works.

Wide range of lances and accessories available to make PRAMAC pressure washers suitable for any application

WHAT IS A HIGH PRESSURE WASHER?

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 8: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

14 15

MODELLO / MODEL

N° SERIE / SERIAL #

V

FREQUENZA / FREQUENCY

POTENZA / POWER

GUIDELINES FOR THE APPLICATION OF THE DIRECTIVE 2000/14/EC The directive 2000/14/EC dated 8th may, 2000 aims to harmonise the laws of the Member States

relating to noise emission standards, conformity assessment procedures, marking, technical

documentation and collection of data concerning the noise emission in the environment of equipment

for outdoor use.

The parameter adopted by this directive for the evaluation of the noise emission level is the Sound Power Level; this identifies the sound emissions of the considered source (the generator), measured in

decibels (dB).

Alternatively, the generic indication of noise level refers to the Acoustic Pressure Level depending, as

well as from the sound energy emitted by the source, on the distance of reading (is to be expressly

specified – usually 7m). This is also measured in decibels (dB).

The two parameters are not independent. The Sound Power Level can be calculated in relation to the

Acoustic Pressure.

Example:

MODEL CODE GUIDELINES

The limits imposed by this directive relate to the Guaranteed Sound Power Level that, as opposed to

the Measured Sound Power Level, takes into consideration all the uncertainties that may arise from

production changes or different measurement procedures.

The following table shows the limits fixed by the directive for generators and motor welders.

Acoustic pressure level at 7 m Sound Power Level

70 dB(A) 95 dB(A)

Sound emission limits depend on the power of the generator. The

reduction of the mentioned limits will happen in two phases (the

first in year 2002, the second in 2006).

The Directive 2000/14/EC also requires that the producer marks

the generator; specifying the Guaranteed Sound Power Level: the

indication of the guaranteed sound power level must consist of the

single-number of the guaranteed sound power in dB, the sign ‘LWA’

and a specified symbol.

Electric Admitted Power Power Level LWA

kW phase I phase II 03/01/2002 03/01/2006

Generator sets Pel ≤ 2 LWA dB(A) 97+log Pel LWA dB(A) 95+log Pel

And motor 2 ≤ Pel ≤ 10 LWA dB(A) 98+log Pel LWA dB(A) 96+log Pel

welders Pel > 10 LWA dB(A) 97+log Pel LWA dB(A) 95+log Pel

S5000 PD412SHB0002004 Y 00244

230V

50Hz

4,97kVA LTP 4,1kVA COP

Pos. 1/2: Class name; Pos. 3/4: Generator power in VAPos. 5: Number of zero referred to power; Pos. 6: Voltage and frequency

Pos. 7: Engine type; Pos. 8: Starting system and fuel type (for the ZG class: Voltage and frequency)

P E 4 O 2 S H I

POS. 1/2 POS. 3/4 POS. 5 POS. 6 POS. 7 POS. 8

VOLTAGE/FREQUENCY ENGINE STARTING SYSTEM/FUEL TYPE

PA E ClassPower in VA,

first two

digits from

the left side

Number

of zero

to complete

the figure

N Asynchronous Asynchronous Asynchronous

H Honda A Electric/DieselPC C Class S Single phase 230V 50 Hz

PD S Class T Three phase 400/230V 50 Hz

PE ES Class

R Ruggerini B Electric/GasolinePF P Class

LA W ClassMaximum welding

current in A

CURRENT REGULATION

C Reverser

Y Yanmar H Manual/DieselLC WP Class

E Electronic

M Manual

NA LG Class

Pressure in BAR Default=0 Z Hatz I Manual/GasolineNB L Class

NC P Class

MA ZG ClassContinuous

power in kVADefault=0 Default=0

VOLTAGE/FREQUENCY

S Single phase 230/115V 50 Hz

T Three phase 400/230V 50 Hz

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 9: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

16 17

HOW TO SELECT A GENERATOR ACCORDING TO THE REQUIRED POWER

The following pages explain the maximum power rating, expressed in Watts, which each generator is

able to supply according to the applied load. Values are purely indicative and may be slightly higher or

lower according to the specific application.

To chose the right PRAMAC generator for your requirements, simply follow these simple steps:

1) Select the necessary power to feed desired equipment,

2) Determine if the load is resistive or inductive,

3) Select the more suitable PRAMAC generator to be used

RESISTIVE LOADSThese are constituted by one or more resistors i.e. electrical components characterised by a resistance

that under a certain voltage generates heat. Example: an electric oven, a stove, a bulb, an iron.

INDUCTIVE LOADS Mainly characterised by the presence of inductances i.e. electrical components that generates

electromagnetic energy.

Voltage and current (having a sinusoidal trend) are out of phase i.e. They reach the maximum value in

two different moments: the angular distance between the two moments determine the phase difference

between voltage and current. Example: a fan, a drill, a pump, an air compressor, a concrete mixer.

POWER IN WATT

MODELRESISTIVE

LOADS 230VLIGHT INDUCTIVE

LOADS 230VHEAVY INDUCTIVE

LOADS 230VHEAVY INDUCTIVE

LOADS 400V

PE

TR

OL

E CLASS

E2400 1900 1550 1050 0

E3100 1950 1600 1050 0

E3200 2200 1750 1200 0

E4000 2650 2100 1400 0

E4900 3250 2600 1750 0

E4900 TF 2350 1850 1250 1950

E5000 3900 3150 2100 0

E5000 TF 2850 2250 1550 2350

E6900 5468 4374 2953 0

DIE

SE

L E4500 3000 2400 1600 0

E6000 TF 3000 2400 1600 2500

E6500 4350 3450 2350 0

PE

TR

OL

ES CLASS

ES3000 2200 1750 1200 0

ES4000 2650 2100 1450 0

ES5000 3900 3150 2100 0

ES5000 TF 2850 2250 1550 2350

ES8000 5500 4400 2950 0

ES8000 TF 3700 2950 2000 3100

S CLASS

S5000 3800 3050 2050 0

S5000 TF 2850 2250 1550 2350

S8000 5500 4400 2950 0

S8000 TF 3700 2950 2000 3100

S12000 3550 2850 1950 2950

S12000 TF 3550 2850 1950 2950

DIE

SE

L

S4500 2900 2300 1550 0

S6000 TF 3000 2400 1600 2500

S6500 4330 3450 2350 0

S9000 6700 5350 3600 0

S9000 TF 4650 3700 2500 3850

PE

TR

OL

C CLASS

C1400 1050 850 600 0

C2000 1550 1250 850 0

C3000 2150 1750 1200 0

P CLASS

P4000 2800 2800 2800 0

P5000 3900 3100 2100 0

P12000 9150 7300 4950 0

P12000 TF 6200 4950 3350 5500

DIE

SE

L

P4500 3000 2300 1550 0

P6000s 4350 3450 2350 0

P6000s TF 3000 2400 1600 2500

P6000 4350 3450 2350 0

P6000 TF 3000 2400 1600 2500

P9000 6700 5350 3600 0

P9000 TF 4650 3700 2500 3850

P11000 9700 7800 5250 0

P11000 TF 5950 4750 3200 4950P12000 TF 5800 4650 3150 4850

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 10: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

GENERATOR SETS

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 11: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

20 21

E

Serie E benzina: Energia essenziale

MODELLO E3200 E4000 E5000 E5000CODICE PA252SHI PA292SHI PA432SHI PA542THIGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 5,04Potenza COP/LTP kVA 5,36/6,30Tensione Volt 400Frequenza Hz 50Fattore di potenza cosϕ 0,8POTENZA MONOFASE

Potenza LTP kW 2,59 3,1 4,6 3,74Potenza COP/LTP kVA 2,45/2,88 2,92/3,44 4,20/5,11 3,14/4,16Tensione Volt 230 230 230 230Frequenza Hz 50 50 50 50Fattore di potenza cosϕ 0,9 0,9 0,9 0,9MOTOREModello Honda Honda Honda HondaTipo GX160 GX200 GX270 GX270Cilindrata CC 163 196 270 270Cilindri 1 inclinato 1 inclinato 1 inclinato 1 inclinatoPotenza kW 3,6 4,3 6,3 6,3Carburante benzina verde benzina verde benzina verde benzina verdeAspirazione naturale naturale naturale naturaleRaffreddamento aria aria aria ariaAvviamento strappo strappo strappo strappoCONSUMOConsumo g/kWh 313 313 313 313Consumo al 75% l/h 0,9 1,1 1,6 1,6Capacità serbatoio l 3,6 3,6 6 6Autonomia al 75% h 3,9 3,2 3,7 3,7LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 97 98 98 98Pressione acustica a 7 m dB(A) 72 73 72 72DIMENSIONILunghezza mm 630 630 715 715Larghezza mm 458 458 540 540Altezza mm 415 415 490 490Peso a secco kg 38 38 74 74DOTAZIONI DI SERIEProtezione termica Protezione oil-guard

Prese 2 x 230V 16A 2 x 230V 16A 2 x 230V 16A1 x 230V 16A1 x 400V 16A

PROTEZIONEProtezione elettrica IP 23 IP 23 IP 23 IP 23Protezione prese IP 44 IP 44 IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto

E Class Petrol: Essential Energy

Simple and essential professional generators; offer maximum

reliability and performance, with a basic but efficient

configuration.

Rigid tubular structure, although light, is tough and provides protection for the generator in tough conditions.

Sockets have IP44 thermal protection and reset device fitted directly to the alternator for a full and optimal use of all the power produced by the generator.

Use

All E-Class alternators are fitted with IP23 protection that ensures safe use even at maximum power.

Alternator

Frame

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

P E T R O L

MODEL E3200 E4000 E5000 E5000 E6900CODE PA252SHI PA292SHI PA432SHI PA542THI PA602SHIGENERATOR 3000 RPMTHREE-PHASE POWER

Power LTP kW 5,04Power COP/LTP kVA 5,36/6,30Voltage Volt 400Frequency Hz 50Power Factor cosϕ 0,8SINGLE-PHASE POWER

Power LTP kW 2,59 3,1 4,6 3,74 6,43Power COP/LTP kVA 2,45/2,88 2,92/3,44 4,20/5,11 3,14/4,16 6,08/7,15Voltage Volt 230 / 115 230 / 115 230 / 115 230 230/115Frequency Hz 50 50 50 50 50Power Factor cosϕ 0,9 0,9 0,9 0,9 0,9ENGINEModel Honda Honda Honda Honda HondaType GX160 GX200 GX270 GX270 GX390Displacement cc 163 196 270 270 389Cylinder 1 inclined 1 inclined 1 inclined 1 inclined 1 inclinedPower kW 3,6 4,3 6,3 6,3 8,3Fuel unleaded petrol unleaded petrol unleaded petrol unleaded petrol gasolineAspiration natural natural natural natural naturalCooling system air air air air airStarting system recoil recoil recoil recoil recoilCONSUMPTIONConsumption g/kWh 313 313 313 313 313Consumption at 75% l/h 0,9 1,1 1,6 1,6 2,2Tank capacity l 3,6 3,6 6 6 6,5Running time at 75% h 3,9 3,2 3,7 3,7 3NOISE EMISSIONNoise level LWA dB(A) 94 98 98 98 99Acoustic pressure at 7 m dB(A) 68 73 72 72 74DIMENSIONS AND WEIGHTLength mm 630 630 715 715 715Width mm 458 458 540 540 550Height mm 415 415 490 490 545Weight (dry) kg 38 38 74 74 78STANDARD EQUIPMENTThermal protection Oil-guard system

Sockets1 X 230V 16A1 X 115V 16A

2 X 230V 16A2 X 115V 16A

2 X 230V 16A1 X 115V 16A1 X 115V 32A

1 x 230V 16A1 x 400V 16A

2 x 230V 16A1 x 115V 16A1 x 115V 32A

PROTECTIONElectric protection IP 23 IP 23 IP 23 IP 23 IP 23Socket protection IP 44 IP 44 IP 44 IP 44 IP 44ACCESSORIESTransportation kit

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 12: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

22: 23

E

Serie E benzina: Non conforme alla direttiva 2000/14/CE

MODELLO E2400* E3100* E4900 E4900CODICE PA212SHI PA222SHI PA352SHI PA442THIGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 4,16Potenza COP/LTP kVA 4,42/5,20Tensione Volt 400Frequenza Hz 50Fattore di potenza cosϕ 0,8POTENZA MONOFASE

Potenza LTP kW 2,24 2,3 3,8 3,09Potenza COP/LTP kVA 2,12/2,49 2,18/2,56 3,59/4,22 2,59/3,43Tensione Volt 230 230 230 230Frequenza Hz 50 50 50 50Fattore di potenza cosϕ 0,9 0,9 0,9 0,9MOTOREModello Honda Honda Honda HondaTipo GX160 LC GX160 LC GX240 GX240Cilindrata CC 163 163 242 242Cilindri 1 inclinato 1 inclinato 1 inclinato 1 inclinatoPotenza kW 3,2 3,2 5,2 5,2Carburante benzina verde benzina verde benzina verde benzina verdeAspirazione naturale naturale naturale naturaleRaffreddamento aria aria aria ariaAvviamento strappo strappo strappo strappoCONSUMOConsumo g/kWh 313 313 313 313Consumo al 75% l/h 0,8 0,8 1,3 1,3Capacità serbatoio l 3,6 3,6 6 6Autonomia al 75% h 4,3 4,3 4,5 4,5LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) ///** ///** ///** ///**Pressione acustica a 7 m dB(A) ///** ///** ///** ///**DIMENSIONILunghezza mm 630 630 715 715Larghezza mm 458 458 540 540Altezza mm 415 415 490 490Peso a secco kg 34 38 61 74DOTAZIONI DI SERIEProtezione termica Protezione oil-guard

Prese 1 x 230V 16A 2 x 230V 16A 2 x 230V 16A1 x 230V 16A1 x 400V 16A

PROTEZIONEProtezione elettrica IP 23 IP 23 IP 23 IP 23Protezione prese IP 44 IP 44 IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto

* Modelli non vendibili nei paesi della Comunità Europea** Non conforme alla direttiva 2000/14/CE

E Class Petrol: Not compliant with directive 2000/14/EC

With the perfect balance of quality and economy, these

generators have reduced fuel consumption, making them

efficient and economical.

Compact and sturdy, this generator is suitable for a wide range of applications due to its versatile dimensions and characteristics.

Sockets have IP44 protection and reset device as part of thermal protection.

Panel

Easy access to the air filter; for fast changing during essential maintenance.

Filter

Strong and Compact

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

P E T R O L

MODEL E2400* E3100* E4900 E4900CODE PA212SHI PA222SHI PA352SHI PA442THIGENERATOR 3000 RPMThree-phase powerPower LTP kW 4,16Power COP/LTP kVA 4,42/5,20Voltage Volt 400Frequency Hz 50Power Factor cosϕ 0,8SINGLE-PHASE POWER

Power LTP kW 2,24 2,3 3,8 3,09Power COP/LTP kVA 2,12/2,49 2,18/2,56 3,59/4,22 2,59/3,43Voltage Volt 230 230 230 230Frequency Hz 50 50 50 50Power Factor cosϕ 0,9 0,9 0,9 0,9ENGINEModel Honda Honda Honda HondaType GX160 LC GX160 LC GX240 GX240Displacement cc 163 163 242 242Cylinder 1 inclined 1 inclined 1 inclined 1 inclinedPower kW 3,2 3,2 5,2 5,2Fuel unleaded petrol unleaded petrol unleaded petrol unleaded petrolAspiration natural natural natural naturalCooling system air air air airStarting system recoil recoil recoil recoilCONSUMPTIONConsumption g/kWh 313 313 313 313Consumption at 75% l/h 0,8 0,8 1,3 1,3Tank capacity l 3,6 3,6 6 6Running time at 75% h 4,3 4,3 4,5 4,5NOISE EMISSIONNoise level LWA dB(A) ///** ///** ///** ///**Acoustic pressure at 7 m dB(A) ///** ///** ///** ///**DIMENSIONS AND WEIGHTLength mm 630 630 715 715Width mm 458 458 540 540Height mm 415 415 490 490Weight (dry) kg 34 38 61 74STANDARD EQUIPMENTThermal protection Oil-guard system

Sockets 1 x 230V 16A 2 x 230V 16A 2 x 230V 16A1 x 230V 16A1 x 400V 16A

PROTECTIONElectric protection IP 23 IP 23 IP 23 IP 23Socket protection IP 44 IP 44 IP 44 IP 44ACCESSORIESTransportation kit

* Not saleable in the EC countries** Not compliant with directive 2000/14/EC

Peter
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 13: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

24 25

E

Serie E Diesel: Non conforme alla direttiva 2000/14/CE

MODELLO E4500 E6000 E6500CODICE PA322SYI PA572TYH PA482SYHGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 5,52Potenza COP/LTP kVA 5,66/6,90Tensione Volt 400Frequenza Hz 50Fattore di potenza cosϕ 0,8POTENZA MONOFASE

Potenza LTP kW 3,5 4,1 5,28Potenza COP/LTP kVA 3,31/3,89 3,32/4,55 4,81/5,87Tensione Volt 230 230 230Frequenza Hz 50 50 50Fattore di potenza cosϕ 0,9 0,9 0,9MOTOREModello Yanmar Yanmar YanmarTipo L70 L100 L100Cilindrata CC 296 406 406Cilindri 1 verticale 1 verticale 1 verticalePotenza kW 4,8 6,9 6,9Carburante gasolio gasolio gasolioAspirazione naturale naturale naturaleRaffreddamento aria aria ariaAvviamento strappo strappo strappoCONSUMOConsumo g/kWh 272 272 272Consumo al 75% l/h 1 1,4 1,4Capacità serbatoio l 3,5 5,5 5,5Autonomia al 75% h 3,4 3,9 3,9LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) ///** ///** ///**Pressione acustica a 7 m dB(A) ///** ///** ///**DIMENSIONILunghezza mm 760 800 800Larghezza mm 490 575 575Altezza mm 530 570 570Peso a secco kg 54 96 100DOTAZIONI DI SERIEProtezione termica

Prese 2 x 230V 16A1 x 230V 16A1 x 400V 16A

1 x 230V 16A1 x 230V 32A

PROTEZIONEProtezione elettrica IP 23 IP 23 IP 23Protezione prese IP 44 IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto

** Non conforme alla direttiva 2000/14/CE

E Class Diesel: Not compliant with directive 2000/14/EC

Diesel generators providing maximum power, efficiently, built

using only quality components for professional users.

The latest generation of diesel engines are easy to use and maintain, and even recoil start is effortless.

1 single phase socket, 1 three phase socket – both fitted with I P44 thermal protection.

Panel

Suitable for any application, these generators are compact and sturdy and able to perform even in the most demanding conditions.

Strong and Compact

Easy Starting

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

D I E S E L

MODEL E4500 E6000 E6500CODE PA322SYH PA572TYH PA482SYHGENERATOR 3000 RPMTHREE-PHASE POWER

Power LTP kW 5,52Power COP/LTP kVA 5,66/6,90Voltage Volt 400Frequency Hz 50Power Factor cosϕ 0,8SINGLE-PHASE POWER

Power LTP kW 3,5 4,1 5,28Power COP/LTP kVA 3,31/3,89 3,32/4,55 4,81/5,87Voltage Volt 230 230 230Frequency Hz 50 50 50Power Factor cosϕ 0,9 0,9 0,9ENGINEModel Yanmar Yanmar YanmarType L70 L100 L100Displacement cc 296 406 406Cylinder 1 vertical 1 vertical 1 verticalPower kW 4,8 6,9 6,9Fuel gasoil gasoil gasoilAspiration natural natural naturalCooling system air air airStarting system recoil recoil recoilCONSUMPTIONConsumption g/kWh 272 272 272Consumption at 75% l/h 1 1,4 1,4Tank capacity l 3,5 5,5 5,5Running time at 75% h 3,4 3,9 3,9NOISE EMISSIONNoise level LWA dB(A) ///** ///** ///**Acoustic pressure at 7 m dB(A) ///** ///** ///**DIMENSIONS AND WEIGHTLength mm 760 800 800Width mm 490 575 575Height mm 530 570 570Weight (dry) kg 54 96 100STANDARD EQUIPMENTThermal protection

Sockets 2 x 230V 16A1 x 230V 16A1 x 400V 16A

1 x 230V 16A1 x 230V 32A

PROTECTIONElectric protection IP 23 IP 23 IP 23Socket protection IP 44 IP 44 IP 44ACCESSORIESTransportation kit

** Not compliant with directive 2000/14/EC

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 14: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

26 27

ES

Serie ES benzina: Energia a lunga durata

MODELLO ES3000 ES4000 ES5000 ES5000 ES8000 ES8000CODICE PE242SHI PE292SHI PE402SHI PE532THI PE612SHI PE652THIGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 5,04 6,64Potenza COP/LTP kVA 5,36 / 6,30 7,00 / 8,30Tensione Volt 400 400Frequenza Hz 50 50Fattore di potenza cosϕ 0,8 0,8POTENZA MONOFASE

Potenza LTP kW 2,59 3,1 4,6 3,74 6,43 4,93Potenza COP/LTP kVA 2.45/2.88 2,92 / 3,44 4,20/5,11 3.14 / 4.16 6,08/7,15 4,11 / 5,48Tensione Volt 230 230 230 230 230 230Frequenza Hz 50 50 50 50 50 50Fattore di potenza cosϕ 0,9 0,9 0,9 0,9 0,9 0,9MOTOREModello Honda Honda Honda Honda Honda HondaTipo GX160 GX200 GX270 GX270 GX390 GX390Cilindrata CC 163 196 270 270 389 389Cilindri 1 inclinato 1 inclinato 1 inclinato 1 inclinato 1 inclinato 1 inclinatoPotenza kW 3,6 4,3 6,3 6,3 8,3 8,3Carburante benzina verde benzina verde benzina verde benzina verde benzina verde benzina verdeAspirazione naturale naturale naturale naturale naturale naturaleRaffreddamento aria aria aria aria aria ariaAvviamento strappo strappo strappo strappo strappo strappoCONSUMOConsumo g/kWh 313 313 313 313 313 313Consumo al 75% l/h 0,9 1,1 1,6 1,6 2,2 2,1Capacità serbatoio l 11 11 11 11 11 11Autonomia al 75% h 11,8 9,9 6,7 6,7 5,1 5,2LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 98 97 98 98 99 99Pressione acustica a 7 m dB(A) 72 71 72 72 73 73DIMENSIONILunghezza mm 623 623 729 729 729 729Larghezza mm 405 405 500 500 500 500Altezza mm 500 500 536 536 536 536Peso a secco kg 41 45 61 75 76 81DOTAZIONI DI SERIEProtezione termica Protezione oil-guard

Prese 2 x 230V 16A 2 x 230V 16A 2 x 230V 16A1 x 230V 16A1 x 400V 16A

1 x 230V 16A1 x 230V 32A

1 x 230V 16A1 x 400V 16A

PROTEZIONEProtezione elettrica IP 23 IP 23 IP 23 IP 23 IP 23 IP 23Protezione prese IP 44 IP 44 IP 44 IP 44 IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto

ES Class Petrol: Long Run Energy

A class of petrol generators designed specifically for intensive

operations where performance power is demanded by

professional users over an extended period of time.

Easy access to the air filter; for simple changing during essential maintenance. User also has easy access to fuel tap and choke knob for controller use.

With a long-run fuel capacity, stored in a safe yet easily accessible tank, ensures an uninterruptible power supply and autonomy whatever size of tasks undertaken.

Fuel Tank

Fitted with both single and three phase sockets and fitted with IP44 thermal protection for user safety.

Sockets

Filter

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

P E T R O L

MODEL ES3000 ES4000 ES5000 ES5000 ES8000 ES8000CODE PE242SHI PE292SHI PE402SHI PE532THI PE612SHI PE652THIGENERATOR 3000 RPMThree-phase powerPower LTP kW 5,04 6,64Power COP/LTP kVA 5,36 / 6,30 7,00 / 8,30Voltage Volt 400 400Frequency Hz 50 50Power Factor cosϕ 0,8 0,8Single-phase powerPower LTP kW 2,59 3,1 4,6 3,74 6,43 4,93Power COP/LTP kVA 2,45/2,88 2,92 / 3,44 4,20/5,11 3.14 / 4.16 6,08/7,15 4,11 / 5,48Voltage Volt 230 / 115 230 / 115 230 / 115 230 230 230Frequency Hz 50 50 50 50 50 50Power Factor cosϕ 0,9 0,9 0,9 0,9 0,9 0,9ENGINEModel Honda Honda Honda Honda Honda HondaType GX160 GX200 GX270 GX270 GX390 GX390Displacement cc 163 196 270 270 389 389Cylinder 1 inclined 1 inclined 1 inclined 1 inclined 1 inclined 1 inclinedPower kW 3,6 4,3 6,3 6,3 8,3 8,3Fuel unleaded petrol unleaded petrol unleaded petrol unleaded petrol unleaded petrol unleaded petrolAspiration natural natural natural natural natural naturalCooling system air air air air air airStarting system recoil recoil recoil recoil recoil recoilCONSUMPTIONConsumption g/kWh 313 313 313 313 313 313Consumption at 75% l/h 0,9 1,1 1,6 1,6 2,2 2,1Tank capacity l 11 11 11 11 11 11Running time at 75% h 11,8 9,9 6,7 6,7 5,1 5,2NOISE EMISSIONNoise level LWA dB(A) 98 97 98 98 99 99Acoustic pressure at 7 m dB(A) 72 71 72 72 73 73DIMENSIONS AND WEIGHTLength mm 623 623 729 729 729 729Width mm 405 405 500 500 500 500Height mm 500 500 536 536 536 536Weight (dry) kg 41 45 61 75 76 81STANDARD EQUIPMENTThermal protection Oil-guard system

Sockets1 X 230V 16A1 X 115V 16A

1 X 230V 16A1 X 115V 16A

1 X 230V 16A1 X 115V 16A

1 x 230V 16A1 x 400V 16A

1 x 230V 16A1 x 230V 32A

1 x 230V 16A1 x 400V 16A

PROTECTIONElectric protection IP 23 IP 23 IP 23 IP 23 IP 23 IP 23Socket protection IP 44 IP 44 IP 44 IP 44 IP 44 IP 44ACCESSORIESTransportation kit

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 15: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

28 29

S

Serie S benzina:Completezza di dotazioni

MODELLO S5000 S5000 S5000 S5000 S8000 S8000 S8000 S8000CODICE PD412SHI PD412SHB PD542THI PD542THB PD612SHI PD612SHB PD652THI PD652THBGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 5,04 5,04 6,64 6,64Potenza COP/LTP kVA 5,36/6,30 5,36/6,30 7,00/8,30 7,00/8,30Tensione Volt 400 400 400 400Frequenza Hz 50 50 50 50Fattore di potenza cos 0,8 0,8 0,8 0,8POTENZA MONOFASE

Potenza LTP kW 4,47 4,47 3,74 3,74 6,43 6,43 4,93 4,93Potenza COP/LTP kVA 4,10/4,97 4,10/4,97 3,14/4,16 3,14/4,16 6,08/7,15 6,08/7,15 4,11/5,48 4,11/5,48Tensione Volt 230 230 230 230 230 230 230 230Frequenza Hz 50 50 50 50 50 50 50 50Fattore di potenza cos 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9MOTOREModello Honda Honda Honda Honda Honda Honda Honda HondaTipo GX270 GX270 GX270 GX270 GX390 GX390 GX390 GX390Cilindrata CC 270 270 270 270 389 389 389 389Cilindri 1 inclinato 1 inclinato 1 inclinato 1 inclinato 1 inclinato 1 inclinato 1 inclinato 1 inclinatoPotenza kW 6,3 6,3 6,3 6,3 8,3 8,3 8,3 8,3Carburante benzina verde benzina verde benzina verde benzina verde benzina verde benzina verde benzina verde benzina verdeAspirazione naturale naturale naturale naturale naturale naturale naturale naturaleRaffreddamento aria aria aria aria aria aria aria ariaAvviamento strappo elettrico strappo elettrico strappo elettrico strappo elettricoCONSUMOConsumo g/kWh 313 313 313 313 313 313 313 313Consumo al 75% l/h 1,63 1,63 1,63 1,63 2,13 2,15 1,98 1,98Capacità serbatoio l 18 18 18 18 18 18 18 18Autonomia al 75% h 11 11 11 11 8,4 8,4 9,1 9,1LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 99 99 98 98 99 99 99 99Pressione acustica a 7 m dB(A) 73 73 72 72 73 73 73 73DIMENSIONILunghezza mm 832 832 832 832 832 832 832 832Larghezza mm 513 513 513 513 513 513 513 513Altezza mm 570 570 570 570 570 570 571 571Peso a secco kg 56 60 77 86 89 94 92 96DOTAZIONI DI SERIEProtezione termica Protezione oil-guard Protezione magnetotermica Carica batterie (12V 10A)

Prese 2 x 230V 16A 2 x 230V 16A1 x 230V 16A1 x 400V 16A

1 x 230V 16A1 x 400V 16A

1 x 230V 16A1 x 230V 32A

1 x 230V 16A1 x 230V 32A

1 x 230V 16A1 x 400V 16A

1 x 230V 16A1 x 400V 16A

PROTEZIONEProtezione elettrica IP 23 IP 23 IP 23 IP 23 IP 23 IP 23 IP 23 IP 23Protezione prese IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto Protezione Isometer Quadro intervento automatico

Disponibile a richiesta versione SP8000 con alternatore IP54

S Class Petrol: The Complete Package

Showcasing the excellence of PRAMAC’s professional

equipment; These generators are the ultimate package when

maximum performance, reliability and efficiency are required.

Rigid tubular structure, although light, is tough and provides protection for the generator even in tough conditions.

Designed for maximum functionality, this complete equipment panel will suit the professional user and is simple enough to understand.

Panel

With a long-run fuel capacity, stored in a safe yet easily accessible tank, ensures an uninterruptible power supply and autonomy for over 8 hours, so no need to refuel more than once a day.

Fuel Tank

Frame

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

P E T R O L

MODEL S5000 S5000 S5000 S5000 S8000 S8000 S8000 S8000CODE PD412SHI PD412SHB PD542THI PD542THB PD612SHI PD612SHB PD652THI PD652THBGENERATOR 3000 RPMTHREE-PHASE POWER

Power LTP kW 5,04 5,04 6,64 6,64Power COP/LTP kVA 5,36/6,30 5,36/6,30 7,00/8,30 7,00/8,30Voltage Volt 400 400 400 400Frequency Hz 50 50 50 50Power Factor cos 0,8 0,8 0,8 0,8SINGLE-PHASE POWER

Power LTP kW 4,47 4,47 3,74 3,74 6,43 6,43 4,93 4,93Power COP/LTP kVA 4,10/4,97 4,10/4,97 3,14/4,16 3,14/4,16 6,08/7,15 6,08/7,15 4,11/5,48 4,11/5,48Voltage Volt 230 / 115 230 / 115 230 230 230 / 115 230 / 115 230 230Frequency Hz 50 50 50 50 50 50 50 50Power Factor cos 0,9 0,9 0,9 0,9 0,9 0,9 0,9 0,9ENGINEModel Honda Honda Honda Honda Honda Honda Honda HondaType GX270 GX270 GX270 GX270 GX390 GX390 GX390 GX390Displacement cc 270 270 270 270 389 389 389 389Cylinder 1 1 1 1 1 inclined 1 inclined 1 inclined 1 inclinedPower kW 6,3 6,3 6,3 6,3 8,3 8,3 8,3 8,3Fuel unleaded petrol unleaded petrol unleaded petrol unleaded petrol unleaded petrol unleaded petrol unleaded petrol unleaded petrolAspiration natural natural natural natural natural natural natural naturalCooling system air air air air air air air airStarting system recoil electric recoil electric recoil electric recoil electricCONSUMPTIONConsumption g/kWh 313 313 313 313 313 313 313 313Consumption at 75% l/h 1,63 1,63 1,63 1,63 2,15 2,15 2,13 2,13Tank capacity l 18 18 18 18 18 18 18 18Running time at 75% h 11 11 11 11 8,4 8,4 8,4 8,4NOISE EMISSIONNoise level LWA dB(A) 97 97 97 97 99 99 99 99Acoustic pressure at 7 m dB(A) 71 71 72 72 73 73 73 73DIMENSIONS AND WEIGHTLength mm 842 842 842 842 842 842 842 842Width mm 523 523 523 523 523 523 523 523Height mm 557 557 557 557 557 557 571 571Weight (dry) kg 71 79 80 88 91 99 91 99STANDARD EQUIPMENTThermal protection Oil-guard system Magneto thermal protection Battery charger (12V 10A)

Sockets2 X 230V 16A1 X 115V 16A1 X 115V 32A

2 X 230V 16A1 X 115V 16A1 X 115V 32A

1 x 230V 16A1 x 400V 16A

1 x 230V 16A1 x 400V 16A

2 X 230V 16A1 X 115V 16A1 X 115V 32A

2 X 230V 16A1 X 115V 16A1 X 115V 32A

1 x 230V 16A1 x 400V 16A

1 x 230V 16A1 x 400V 16A

PROTECTIONElectric protection IP 23 IP 23 IP 23 IP 23 IP 23 IP 23 IP 23 IP 23Socket protection IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44 IP 44ACCESSORIESTransportation kit Lifting kit Isometer protection AMF AVR

Available under request the version SP8000 with IP54 alternator

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 16: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

30 31

S

Serie S benzina: Non conforme alla direttiva 2000/14/CE

MODELLO S12000 S12000CODICE PD103SHB PD123THBGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 11,07Potenza COP/LTP kVA 11,76/13,84Tensione Volt 400Frequenza Hz 50Fattore di potenza cosϕ 0,8POTENZA MONOFASE

Potenza LTP kW 10,73 8,22Potenza COP/LTP kVA 10,00/11,93 6,90/9,13Tensione Volt 230 230Frequenza Hz 50 50Fattore di potenza cosϕ 0,9 0,9MOTOREModello Honda HondaTipo GX620 GX620Cilindrata CC 614 614Cilindri 2 a V 2 a VPotenza kW 14 14Carburante benzina verde benzina verdeAspirazione naturale naturaleRaffreddamento aria ariaAvviamento elettrico elettricoCONSUMOConsumo g/kWh 313 313Consumo al 75% l/h 3,8 3,8Capacità serbatoio l 11 11Autonomia al 75% h 2,9 2,9LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) ///** ///**Pressione acustica a 7 m dB(A) ///** ///**DIMENSIONILunghezza mm 830 830Larghezza mm 490 490Altezza mm 570 570Peso a secco kg 98 101DOTAZIONI DI SERIEProtezione oil-guard Protezione magnetotermica Protezione Isometer Voltmetro

Prese2 x 230V 16A1 x 230V 32A

3 x 230V 16A1 x 400V 16A

PROTEZIONEProtezione elettrica IP 23 IP 23Protezione prese IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto Contaore Quadro intervento automatico

** Non conforme alla direttiva 2000/14/CE

S Class Petrol: Not compliant with directive 2000/14/EC

All the features of a top class generator: A powerful and

economical engine, a strong and modern design and a long-run

easy filling fuel tank.

This machine is easily accessible from three sides allowing easy and quick access to all its components.

High levels of safety and control means this generator range is perfect for any application.

Panel

Suitable for any application, these generators are compact and sturdy and able to perform even in the most demanding conditions.

Strong and Compact

Easy Access

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

P E T R O L

MODEL S12000 S12000CODE PD103SHB PD123THBGENERATOR 3000 RPMTHREE-PHASE POWER

Power LTP kW 11,07Power COP/LTP kVA 11,76/13,84Voltage Volt 400Frequency Hz 50Power Factor cosϕ 0,8SINGLE-PHASE POWER

Power LTP kW 10,73 8,22Power COP/LTP kVA 10,00/11,93 6,90/9,13Voltage Volt 230 230Frequency Hz 50 50Power Factor cosϕ 0,9 0,9ENGINEModel Honda HondaType GX620 GX620Displacement cc 614 614Cylinder 2 V 2 VPower kW 14 14Fuel unleaded petrol unleaded petrolAspiration natural naturalCooling system air airStarting system electric electricCONSUMPTIONConsumption g/kWh 313 313Consumption at 75% l/h 3,5 3,5Tank capacity l 24 24Running time at 75% h 2,9 2,9NOISE EMISSIONNoise level LWA dB(A) 98 98Acoustic pressure at 7 m dB(A) 72 72DIMENSIONS AND WEIGHTLength mm 840 840Width mm 641 641Height mm 667 667Weight (dry) kg 155 159STANDARD EQUIPMENTOil-guard system Magneto thermal protection Isometer protection Voltmeter

Sockets2 x 230V 16A1 x 230V 32A

3 x 230V 16A1 x 400V 16A

PROTECTIONElectric protection IP 23 IP 23Socket protection IP 44 IP 44ACCESSORIESTransportation kit Hourmeter AMF

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 17: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

32 33

S

Serie S Diesel: Non conforme alla direttiva 2000/14/CE

MODELLO S4500 S6000 S6500CODICE PD322SYA PD572TYA PD482SYAGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 5,53Potenza COP/LTP kVA 5,67/6,92Tensione Volt 400Frequenza Hz 50Fattore di potenza cosϕ 0,8POTENZA MONOFASE

Potenza LTP kW 3,41 4,11 5,28Potenza COP/LTP kVA 3,22/3,79 3,33/4,57 4,81/5,87Tensione Volt 230 230 230Frequenza Hz 50 50 50Fattore di potenza cosϕ 0,9 0,9 0,9MOTOREModello Yanmar Yanmar YanmarTipo L70 L100 L100Cilindrata CC 296 406 406Cilindri 1 verticale 1 verticale 1 verticalePotenza kW 4,8 6,9 6,9Carburante gasolio gasolio gasolioAspirazione naturale naturale naturaleRaffreddamento aria aria ariaAvviamento elettrico elettrico elettricoCONSUMOConsumo g/kWh 272 272 272Consumo al 75% l/h 1 1,41 1,41Capacità serbatoio l 3,5 5,5 5,5Autonomia al 75% h 3,4 3,9 3,9LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) ///** ///** ///**Pressione acustica a 7 m dB(A) ///** ///** ///**DIMENSIONILunghezza mm 810 830 830Larghezza mm 450 490 490Altezza mm 500 570 570Peso a secco kg 84 112 105DOTAZIONI DI SERIEProtezione magnetotermica Protezione differenziale Voltmetro Carica batterie (12V 10A)

Prese2 x 230V 16A1 x 230V 32A

2 x 230V 16A1 x 400V 16A

2 x 230V 16A1 x 230V 32A

PROTEZIONEProtezione elettrica IP 23 IP 23 IP 23Protezione prese IP 44 IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto Protezione Isometer Contaore Quadro intervento automatico Comando a distanza

** Non conforme alla direttiva 2000/14/CE

S Class Diesel: Not compliant with directive 2000/14/EC

Built to the same high specification as the S Class Petrol

products, this range offers the same robust package with a

modern and economical Diesel engine.

The semi-opened structure of the machine offers easy access without compromising physical protection to the engine, alternator or electrical panel.High levels of safety and control means this

generator range is perfect for any application.

Panel

The engine is fully accessible from all sides for any types of maintenance and any other necessary operation.

Engine

Frame

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

D I E S E L

MODEL S4500 S6000 S6500CODE PD322SYA PD572TYA PD482SYAGENERATOR 3000 RPMTHREE-PHASE POWER

Power LTP kW 5,53Power COP/LTP kVA 5,67/6,92Voltage Volt 400Frequency Hz 50Power Factor cos 0,8SINGLE-PHASE POWER

Power LTP kW 3,41 4,11 5,28Power COP/LTP kVA 3,22/3,79 3,33/4,57 4,81/5,87Voltage Volt 230 230 230Frequency Hz 50 50 50Power Factor cos 0,9 0,9 0,9ENGINEModel Yanmar Yanmar YanmarType L70 L100 L100Displacement cc 296 406 406Cylinder 1 vertical 1 vertical 1 verticalPower kW 4,8 6,9 6,9Fuel gasoil gasoil gasoilAspiration natural natural naturalCooling system air air airStarting system electric electric electricCONSUMPTIONConsumption g/kWh 272 272 272Consumption at 75% l/h 1 1,41 1,41Tank capacity l 3,5 5,5 5,5Running time at 75% h 3,4 3,9 3,9NOISE EMISSIONNoise level LWA dB(A) ///** ///** ///**Acoustic pressure at 7 m dB(A) ///** ///** ///**DIMENSIONS AND WEIGHTLength mm 810 830 830Width mm 450 490 490Height mm 500 570 570Weight (dry) kg 84 112 105STANDARD EQUIPMENTMagneto thermal protection Differential protection Voltmeter Battery charger (12V 10A)

Sockets2 x 230V 16A1 x 230V 32A

2 x 230V 16A1 x 400V 16A

2 x 230V 16A1 x 230V 32A

PROTECTIONElectric protection IP 23 IP 23 IP 23Socket protection IP 44 IP 44 IP 44ACCESSORIESTransportation kit Isometer protection Hourmeter AMF Remote control

** Not compliant with directive 2000/14/EC

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 18: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

34 35

S

Serie S Diesel: Non conforme alla direttiva 2000/14/CE

MODELLO S9000 S9000CODICE PD752SRA PD882TRAGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 8,15Potenza COP/LTP kVA 8,76/10,19Tensione Volt 400Frequenza Hz 50Fattore di potenza cosϕ 0,8POTENZA MONOFASE

Potenza LTP kW 7,8 6,05Potenza COP/LTP kVA 7,45/8,67 5,14/6,72Tensione Volt 230 230Frequenza Hz 50 50Fattore di potenza cosϕ 0,9 0,9MOTOREModello Ruggerini RuggeriniTipo MD150 MD150Cilindrata CC 654 654Cilindri 2 in linea 2 in lineaPotenza kW 10 10Carburante gasolio gasolioAspirazione naturale naturaleRaffreddamento aria ariaAvviamento elettrico elettricoCONSUMOConsumo g/kWh 260 260Consumo al 75% l/h 2,05 2,05Capacità serbatoio l 24 24Autonomia al 75% h 11,7 11,7LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) ///** ///**Pressione acustica a 7 m dB(A) ///** ///**DIMENSIONILunghezza mm 970 970Larghezza mm 600 600Altezza mm 690 690Peso a secco kg 149 153DOTAZIONI DI SERIEProtezione magnetotermica Indicatore pressione olio

Prese1 x 230V 16A1 x 230V 32A

1 x 230V 16A1 x 400V 16A

PROTEZIONEProtezione elettrica IP 23 IP 23Protezione prese IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto Protezione Isometer Protezione differenziale Voltmetro Quadro intervento automatico Comando a distanza

** Non conforme alla direttiva 2000/14/CE

S Class Diesel: Not compliant with directive 2000/14/EC

Built to the same high specification as the S Class Petrol

products, this range offers the same robust package with a

modern and economical Diesel engine.

Rigid tubular structure, although light, is tough and provides protection for the generator even in tough conditions.

Complete with easy to read displays, incorporating superb design and practicality.

Panel

One of the biggest in its class, this efficient generator has a possible autonomy of almost 12 hours, eliminating the need to refuel, even through the toughest of days.

Fuel Tank

Frame

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

D I E S E L

MODEL S9000 S9000CODE PD752SRA PD882TRAGENERATOR 3000 RPMTHREE-PHASE POWER

Power LTP kW 8,15Power COP/LTP kVA 8,76/10,19Voltage Volt 400Frequency Hz 50Power Factor cosϕ 0,8SINGLE-PHASE POWER

Power LTP kW 7,8 6,05Power COP/LTP kVA 7,45/8,67 5,14/6,72Voltage Volt 230 230Frequency Hz 50 50Power Factor cosϕ 0,9 0,9ENGINEModel Ruggerini RuggeriniType MD150 MD150Displacement cc 654 654Cylinder 2 in line 2 in linePower kW 10 10Fuel gasoil gasoilAspiration natural naturalCooling system air airStarting system electric electricCONSUMPTIONConsumption g/kWh 260 260Consumption at 75% l/h 2,05 2,05Tank capacity l 24 24Running time at 75% h 11,7 11,7NOISE EMISSIONNoise level LWA dB(A) ///** ///**Acoustic pressure at 7 m dB(A) ///** ///**DIMENSIONS AND WEIGHTLength mm 970 970Width mm 600 600Height mm 690 690Weight (dry) kg 149 153STANDARD EQUIPMENTMagneto thermal protection Oil pressure indicator

Sockets1 x 230V 16A1 x 230V 32A

1 x 230V 16A1 x 400V 16A

PROTECTIONElectric protection IP 23 IP 23Socket protection IP 44 IP 44ACCESSORIESTransportation kit Isometer protection Differential protection Voltmeter AMF Remote control

** Not compliant with directive 2000/14/EC

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 19: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

36 37

C

Serie C benzina:Compattezza e design

MODELLO C1400CODICE PC122SHIGENERATORE DI CORRENTE 3000 RPMPOTENZA MONOFASE

Potenza LTP kW 1,31Potenza COP/LTP kVA 1,17/1,45Tensione Volt 230Frequenza Hz 50Fattore di potenza cosϕ 0,9MOTOREModello HondaTipo GC135Cilindrata CC 135Cilindri 1 verticalePotenza kW 2,7Carburante benzina verdeAspirazione naturaleRaffreddamento ariaAvviamento strappoCONSUMOConsumo g/kWh 313Consumo al 75% l/h 0,5Capacità serbatoio l 6,5Autonomia al 75% h 13,9LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 90Pressione acustica a 7 m dB(A) 65DIMENSIONILunghezza mm 550Larghezza mm 370Altezza mm 410Peso a secco kg 35DOTAZIONI DI SERIEProtezione termica Protezione oil-guard Trolley Indicatore presenza tensione Prese 1 x 230V 16APROTEZIONEProtezione elettrica IP 23Protezione prese IP 44

C Class Petrol: Where practicality and design are required in equal measures

This generator incorporates the functionality and efficiency

required by domestic users with design and attractiveness.

This generator is easy to use, easy to transport and easy to

store. Whether you need to power your camping holiday or

light-up a fishing trip or as back up power at home – this

generator will soon prove indispensable.

The long run fuel tank is completely integrated into the generators design has a capacity of 6 litres and an accessible fuel cap.

A simple and useful control panel equipped with a single phase 16A socket, a main switch voltage presence indicator and a reset button for thermal protection.

Panel

The telescopic handle with ergonomic grip stows away easily and allows effortless trolley like manoeuvrability using the machine’s wheels.

Handle

Fuel Tank

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

P E T R O L

MODEL C1400CODE PC122SHIGENERATOR 3000 RPMSINGLE-PHASE POWER

Power LTP kW 1,31Power COP/LTP kVA 1,17/1,45Voltage Volt 230Frequency Hz 50Power Factor cosϕ 0,9ENGINEModel HondaType GC135Displacement cc 135Cylinder 1 verticalPower kW 2,7Fuel unleaded petrolAspiration naturalCooling system airStarting system recoilCONSUMPTIONConsumption g/kWh 313Consumption at 75% l/h 0,5Tank capacity l 6,5Running time at 75% h 13,9NOISE EMISSIONNoise level LWA dB(A) 90Acoustic pressure at 7 m dB(A) 65DIMENSIONS AND WEIGHTLength mm 550Width mm 370Height mm 410Weight (dry) kg 35STANDARD EQUIPMENTThermal protection Oil-guard system Trolley Voltage presence indicator Sockets 1 X 230V 13APROTECTIONElectric protection IP 23Socket protection IP 44

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 20: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

38 39

C

Serie C benzina:Compattezza e silenzionsità

MODELLO C2000 C3000CODICE PC172SHI PC242SHIGENERATORE DI CORRENTE 3000 RPMPOTENZA MONOFASE

Potenza LTP kW 1,82 2,54Potenza COP/LTP kVA 1,72/2,02 2,40/2,82Tensione Volt 230 230Frequenza Hz 50 50Fattore di potenza cosϕ 0,9 0,9MOTOREModello Honda HondaTipo GX120 GX160Cilindrata CC 118 163Cilindri 1 inclinato 1 inclinatoPotenza kW 2,6 3,6Carburante benzina verde benzina verdeAspirazione naturale naturaleRaffreddamento aria ariaAvviamento strappo strappoCONSUMOConsumo g/kWh 313 313Consumo al 75% l/h 0,7 0,9Capacità serbatoio l 11 11Autonomia al 75% h 16,3 11,8LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 94 95Pressione acustica a 7 m dB(A) 69 70DIMENSIONILunghezza mm 620 620Larghezza mm 405 405Altezza mm 400 400Peso a secco kg 42 43DOTAZIONI DI SERIEProtezione termica Protezione oil-guard Carica batterie (12V 10A) Indicatore presenza tensione Prese 2 x 230V 16A 2 x 230V 16APROTEZIONEProtezione elettrica IP 23 IP 23Protezione prese IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto Protezione Isometer

C Class Petrol: Silent and Compact

This machine was designed for residential and domestic use,

but with all the features and equipment usually found on a

professional generator. The design of the frame means the

generator is strong, silent and aesthetically styled.

A high capacity tank with easy to reach fuel cap mean refuelling is infrequent, simple and safe.

Two single phase 16A sockets, engine cut off switch, voltage presence light, battery charger terminal and thermal protection reset button ensures the spec of this machine matches that required for professional use, in a domestic package.

Panel

Easy access to the air filter for simple changing during essential maintenance. Recoil handle is in an ideal position for safe and effortless starting.

Air Filter / Engine Starting

Fuel Cap and Tank

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

P E T R O L

MODEL C2000 C3000CODE PC172SHI PC242SHIGENERATOR 3000 RPMSINGLE-PHASE POWER

Power LTP kW 1,82 2,54Power COP/LTP kVA 1,72/2,02 2,40/2,82Voltage Volt 230 230Frequency Hz 50 50Power Factor cosϕ 0,9 0,9ENGINEModel Honda HondaType GX120 GX160Displacement cc 118 163Cylinder 1 inclined 1 inclinedPower kW 2,6 3,6Fuel unleaded petrol unleaded petrolAspiration natural naturalCooling system air airStarting system recoil recoilCONSUMPTIONConsumption g/kWh 313 313Consumption at 75% l/h 0,7 0,9Tank capacity l 11 11Running time at 75% h 16,3 11,8NOISE EMISSIONNoise level LWA dB(A) 94 95Acoustic pressure at 7 m dB(A) 69 70DIMENSIONS AND WEIGHTLength mm 620 620Width mm 405 405Height mm 400 400Weight (dry) kg 42 43STANDARD EQUIPMENTThermal protection Oil-guard system Battery charger (12V 10A) Voltage presence indicator Sockets 2 x 230V 16A 2 x 230V 16APROTECTIONElectric protection IP 23 IP 23Socket protection IP 44 IP 44ACCESSORIESTransportation kit Isometer protection

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 21: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

40 41

P

Serie P Inverter benzina:Tecnologia e rispetto per l’ambiente

MODELLO P4000 CODICE PF282SHIGENERATORE DI CORRENTE 3000 RPMPOTENZA MONOFASE

Potenza LTP KW 3,0Potenza COP/LTP kVA 2,80/3,0Tensione Volt 230Frequenza Hz 50Fattore di potenza cosϕ 1Alternatore 18 poliMOTOREModello HondaTipo GX200Cilindrata CC 196Cilindri 1 inclinatoPotenza kW 4,8Carburante benzina verdeAspirazione naturaleRaffreddamento ariaAvviamento strappoCONSUMOConsumo g/kWh 313Consumo al 75% l/h 1,21Capacità serbatoio l 11Autonomia al 75% h 9,1LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 93Pressione acustica a 7 m dB(A) 67DIMENSIONILunghezza mm 580Larghezza mm 400Altezza mm 436Peso a secco kg 53DOTAZIONI DI SERIEProtezione magnetotermica Protezione oil-guard Voltmetro Amperometro Contaore Protezione sovratemperatura Protezione fuori giri Regolatore elettronico di giri Economizzatore Trolley Carica batterie (12V 10A) Prese 2 x 230V 16APROTEZIONEProtezione elettrica IP 23Protezione prese IP 44ACCESSORI A RICHIESTADispositivo di parallelo per 2 generatori UPS

P Class Inverter Petrol: Technology with Respect for the Environment

The latest technological developments have led to generators

that are able to produce electrical energy with constant

frequency and voltage at all loads and engine speeds. The

availability of integrated UPS and accessories such as Solar

panels allows PRAMAC to bring high specification generators

to a domestic and budget market.

A UPS (Uninterruptible Power Supply) unit exclusively designed for the PRAMAC P4000i assures a perfect source of energy. Can be used to assure a continuity of energy supply in any condition, or as a fully silenced and clean source of power (when used in conjunction with the UPS batteries).

Along with the other advanced components, the P4000i is equipped with an easy to read multilingual LCD display giving all indications of electrical parameters, possible failures and oil change time indication.

Panel

The telescopic handle with ergonomic grip stows away easily and allows effortless trolley like manoeuvrability using the machine’s wheels.

Wheels and Handle

UPS

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

P E T R O L

UPSCODE PY000A0000U PY000A0000VCHARACTERISTICSBattery type Ah/V 14/12Batteries n° 4 8Recharge time when connectedto mains network

h 9 18

DIMENSIONS AND WEIGHTLength mm 331 331 Width mm 215 215Height mm 410 723Weight (dry) kg 40 60

MODEL P4000iCODE PF282SHIGENERATOR 3000 RPMSINGLE-PHASE POWER

Power LTP kW 3,0Power COP/LTP kVA 2,80/3,0Voltage Volt 230Frequency Hz 50Power Factor cosϕ 1Alternator 18 poliENGINEModel HondaType GX200Displacement cc 196Cylinder 1 inclinedPower kW 4,8Fuel unleaded petrolAspiration naturalCooling system airStarting system recoilCONSUMPTIONConsumption g/kWh 313Consumption at 75% l/h 1,21Tank capacity l 11Running time at 75% h 9,1NOISE EMISSIONNoise level LWA dB(A) 93Acoustic pressure at 7 m dB(A) 67DIMENSIONS AND WEIGHTLength mm 580Width mm 400Height mm 436Weight (dry) kg 53STANDARD EQUIPMENTMagneto thermal protection Oil-guard system Voltmeter Ammeter Hourmeter Over temperature protection Over speed protection RPM electronic regulator Economiser Trolley Battery charger (12V 10A) Sockets 2 x 230V 16APROTECTIONElectric protection IP 23Socket protection IP 44ACCESSORIESParallel device for 2 generators UPS

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 22: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

42 43

P

Serie P benzina: Potenza silenziosa

MODELLO P5000 P12000 P12000CODICE PF432SHB PF103SHB PF123THBGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 11,07Potenza COP/LTP kVA 11,76/13,84Tensione Volt 400Frequenza Hz 50Fattore di potenza cosϕ 0,8POTENZA MONOFASE

Potenza LTP kW 4,79 10,73 8,22Potenza COP/LTP kVA 4,30/5,32 10,00/11,93 6,90/9,13Tensione Volt 230 230 230Frequenza Hz 50 50 50Fattore di potenza cosϕ 0,9 0,9 0,9MOTOREModello Honda Honda HondaTipo GX270 GX620 GX620Cilindrata CC 270 614 614Cilindri 1 inclinato 2 a V 2 a VPotenza kW 6,3 13,5 13,5Carburante benzina verde benzina verde benzina verdeAspirazione naturale naturale naturaleRaffreddamento aria aria ariaAvviamento elettrico elettrico elettricoCONSUMOConsumo g/kWh 313 313 313Consumo al 75% l/h 1,6 3,5 3,5Capacità serbatoio l 6 24 24Autonomia al 75% h 3,9 6,9 6,9LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 92 97 97Pressione acustica a 7 m dB(A) 67 71 71DIMENSIONILunghezza mm 900 930 930Larghezza mm 580 555 555Altezza mm 665 800 800Peso a secco kg 119 166 176DOTAZIONI DI SERIEProtezione oil-guard Protezione magnetotermica Protezione differenziale Protezione sovratemperatura Voltmetro Gancio di sollevamento Connettore QIA

Prese 2 x 230V 16A2 x 230V 16A1 x 230V 32A

3 x 230V 16A1 x 400V 16A

PROTEZIONEProtezione elettrica IP 23 IP 23 IP 23Protezione prese IP 44 IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto Comando a distanza (40m) Quadro intervento automatico Protezione Isometer Protezione differenziale

P Class Petrol: Silent Power

The ideal generator for use in residential areas or outside

normal working hours. Low noise levels, built in plug for

AMF or remote control, mean that this generator is equipped

and ideal for use as a domestic back up power supply or for

professional users in residential areas.

AMF (Automatic Mains Failure) is a feature that enables the user to configure the generator to take over as power supplier if the primary source is cut. This will guarantee continuous power through a seamless changeover and power-up. This is an essential feature of any back up generator set.

Complete with easy to read displays, incorporating superb design and practicality.

Panel

With an easy lifting canopy hood, all engine maintenance is safe and easy.

Accessibility

AMF Panel

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

P E T R O L

MODEL P5000 P12000 P12000CODE PF432SHB PF103SHB PF123THBGENERATOR 3000 RPMTHREE-PHASE POWER

Power LTP kW 11,07Power COP/LTP kVA 11,76/13,84Voltage Volt 400Frequency Hz 50Power Factor cosϕ 0,8SINGLE-PHASE POWER

Power LTP kW 4,79 10,73 8,22Power COP/LTP kVA 4,30/5,32 10,00/11,93 6,90/9,13Voltage Volt 230 / 115 230 / 115 230 230Frequency Hz 50 50 50Power Factor cosϕ 0,9 0,9 0,9ENGINEModel Honda Honda HondaType GX270 GX620 GX620Displacement CC 270 614 614Cylinder 1 inclined 2 V 2 VPower kW 6,3 13,5 13,5Fuel unleaded petrol unleaded petrol unleaded petrolAspiration natural natural naturalCooling system air air airStarting system electric electric electricCONSUMPTIONConsumption g/kWh 313 313 313Consumption at 75% l/h 1,6 3,5 3,5Tank capacity l 6 24 24Running time at 75% h 3,9 6,9 6,9NOISE EMISSIONNoise level LWA dB(A) 92 97 97Acoustic pressure at 7 m dB(A) 67 71 71DIMENSIONS AND WEIGHTLength mm 900 930 930Width mm 580 555 555Height mm 665 800 800Weight (dry) kg 119 166 176STANDARD EQUIPMENTOil-guard system Magneto thermal protection Differential protection Over temperature protection Voltmeter Lifting hook AMF connector

Sockets1 X 230V 16A1 X 115V 16A1 X 115V 32A

2 X 230V 16A1 X 115V 16A1 X 115V 32A

1 X 230V 63A3 x 230V 16A1 x 400V 16A

PROTECTIONElectric protection IP 23 IP 23 IP 23Socket protection IP 44 IP 44 IP 44ACCESSORIESTransportation kit Remote control AMF panel Isometer protection Differential protection

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 23: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

44 45

P

Serie P Diesel:Potenza inferiore a 5 kVA

MODELLO P4500 P4500CODICE PF322SYH PF322SYAGENERATORE DI CORRENTE 3000 RPMPOTENZA MONOFASE

Potenza LTP kW 3,41 3,41Potenza COP/LTP kVA 3,22/3,79 3,22/3,79Tensione Volt 230 230Frequenza Hz 50 50Fattore di potenza cosϕ 0,9 0,9MOTOREModello Yanmar YanmarTipo L70 L70Cilindrata CC 296 296Cilindri 1 verticale 1 verticalePotenza kW 4,8 4,8Carburante gasolio gasolioAspirazione naturale naturaleRaffreddamento aria ariaAvviamento strappo elettricoCONSUMOConsumo g/kWh 272 272Consumo al 75% l/h 1 1Capacità serbatoio l 18 18Autonomia al 75% h 17,7 17,7LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 96 96Pressione acustica a 7 m dB(A) 71 71DIMENSIONILunghezza mm 800 800Larghezza mm 520 520Altezza mm 660 660Peso a secco kg 98 103DOTAZIONI DI SERIEProtezione magnetotermica Voltmetro

Prese2 x 230V 16A1 x 230V 32A

2 x 230V 16A1 x 230V 32A

PROTEZIONEProtezione elettrica IP 23 IP 23Protezione prese IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto Comando a distanza (40m) Quadro intervento automatico Protezione Isometer Protezione differenziale

P Class Diesel: Power less than 5kVa

The smallest diesel generator sets have the unique ability

to supply quality electrical energy for almost 18 hours

without refuelling. The economical and hard working diesel

engines make for the ideal generator set for the demanding

professional.

A fuel tap cut off guarantees diesel will not flow when the generator is not in use.

Complete with easy to read displays, incorporating superb design and practicality, allow the user complete control of all functions with assured safety.

Panel

Easy access to oil cap means for quick and straight forward oil changes and refilling. Recoil handle is in an ideal position for safe and effortless starting.

Oil Change Access and Recoil Starting Handle

Fuel Tap

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

D I E S E L

MODEL P4500 P4500CODE PF322SYH PF322SYAGENERATOR 3000 RPMSINGLE-PHASE POWER

Power LTP kW 3,41 3,41Power COP/LTP kVA 3,22/3,79 3,22/3,79Voltage Volt 230 / 115 230 / 115Frequency Hz 50 50Power Factor cosϕ 0,9 0,9ENGINEModel Yanmar YanmarType L70 L70Displacement CC 296 296Cylinder 1 vertical 1 verticalPower kW 4,8 4,8Fuel gasoil gasoilAspiration natural naturalCooling system air airStarting system recoil electricCONSUMPTIONConsumption g/kWh 272 272Consumption at 75% l/h 1 1Tank capacity l 18 18Running time at 75% h 17,7 17,7NOISE EMISSIONNoise level LWA dB(A) 96 96Acoustic pressure at 7 m dB(A) 71 71DIMENSIONS AND WEIGHTLength mm 800 800Width mm 520 520Height mm 660 660Weight (dry) kg 98 103STANDARD EQUIPMENTMagneto thermal protection Voltmeter

Sockets2 X 230V 16A2 X 115V 16A

2 X 230V 16A2 X 115V 16A

PROTECTIONElectric protection IP 23 IP 23Socket protection IP 44 IP 44ACCESSORIESTransportation kit Remote control AMF panel Isometer protection Differential protection PL

EASE

NOT

E: T

his

mod

el is

sho

wn

with

an

optio

nal t

rolle

y ki

t whi

ch is

not

fitt

ed a

s st

anda

rd

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 24: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

46 47

P

Serie P Diesel:Potenza da 5 a 9 kVA

MODELLO P6000 P6000 P6000s P6000s P9000 P9000CODICE PF482SYA PF572TYA PF532SYA PF602TYA PF752SRA PF882TRAGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 5,53 5,53 8,15Potenza COP/LTP kVA 5,67/6,92 5,67/6,92 8,76/10,19Tensione Volt 400 400 400Frequenza Hz 50 50 50Fattore di potenza cosϕ 0,8 0,8 0,8POTENZA MONOFASE

Potenza LTP kW 5,28 4,11 5,28 4,11 7,8 6,05Potenza COP/LTP kVA 4,81/5,87 3,33/4,57 4,81/5,87 3,33/4,57 7,45/8,67 5,14/6,72Tensione Volt 230 230 230 230 230 230Frequenza Hz 50 50 50 50 50 50Fattore di potenza cosϕ 0,9 0,9 0,9 0,9 0,9 0,9MOTOREModello Yanmar Yanmar Yanmar Yanmar Ruggerini RuggeriniTipo L100 L100 L100 L100 MD150 MD150Cilindrata CC 406 406 406 406 654 654Cilindri 1 in verticale 1 in verticale 1 in verticale 1 in verticale 2 in linea 2 in lineaPotenza kW 6,9 6,9 6,9 6,9 10 10Carburante gasolio gasolio gasolio gasolio gasolio gasolioAspirazione naturale naturale naturale naturale naturale naturaleRaffreddamento aria aria aria aria aria ariaAvviamento elettrico elettrico elettrico elettrico elettrico elettricoCONSUMOConsumo g/kWh 272 272 272 272 260 260Consumo al 75% l/h 1,4 1,4 1,4 1,4 2,1 2,1Capacità serbatoio l 24 24 21 21 24 24Autonomia al 75% h 17 17 14,9 14,9 11,7 11,7LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 98 98 83 83 99 99Pressione acustica a 7 m dB(A) 72 72 57 57 73 73DIMENSIONILunghezza mm 930 930 970 970 930 930Larghezza mm 555 555 580 580 555 555Altezza mm 800 800 800 800 800 800Peso a secco kg 149 153 205 205 190 193DOTAZIONI DI SERIEProtezione magnetotermica Voltmetro Gancio di sollevamento

Prese2 x 230V 16A1 x 230V 32A

3 x 230V 16A1 x 400V 16A

3 x 230V 16A2 x 230V 16A1 x 400V 16A

2 x 230V 16A1 x 230V 32A

3 x 230V 16A1 x 400V 16A

PROTEZIONEProtezione elettrica IP 23 IP 23 IP 23 IP 23 IP 23 IP 23Protezione prese IP 44 IP 44 IP 44 IP 44 IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto Comando a distanza (40m) Quadro intervento automatico Protezione Isometer Protezione differenziale

P Class Diesel: Power from 5 to 9 kVa

Equipped to the same standards as the petrol versions, yet

using a powerful and reliable diesel engine, these generators

offer the maximum in performance, reliability and economy.

Lateral doors make it easy to access the engine bay for maintenance and service operations.

Complete with easy to read displays, incorporating superb design and practicality, allow the user complete control of all functions with assured safety.

Panel

The strong lifting eye integrated into the frame with a dedicated cover allows easy and effortless moving of the generator.

Lifting Eye

Easy Access

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

D I E S E L

MODEL P6000 P6000 P6000s P6000s P9000 P9000CODE PF482SYA PF572TYA PF532SYA PF602TYA PF752SRA PF882TRAGENERATOR 3000 RPMTHREE-PHASE POWER

Power LTP kW 5,53 5,53 8,15Power COP/LTP kVA 5,67/6,92 5,67/6,92 8,76/10,19Voltage Volt 400 400 400Frequency Hz 50 50 50Power Factor cosϕ 0,8 0,8 0,8SINGLE-PHASE POWER

Power LTP kW 5,28 4,11 5,28 4,11 7,8 6,05Power COP/LTP kVA 4,81/5,87 3,33/4,57 4,81/5,87 3,33/4,57 7,45/8,67 5,14/6,72Voltage Volt 230 / 115 230 230 / 115 230 230 / 115 230Frequency Hz 50 50 50 50 50 50Power Factor cosϕ 0,9 0,9 0,9 0,9 0,9 0,9ENGINEModel Yanmar Yanmar Yanmar Yanmar Ruggerini RuggeriniType L100 L100 L100 L100 MD150 MD150Displacement CC 406 406 406 406 654 654Cylinder 1 in vertical 1 in vertical 1 in vertical 1 in vertical 2 in line 2 in linePower kW 6,9 6,9 6,9 6,9 10 10Fuel gasoil gasoil gasoil gasoil gasoil gasoilAspiration natural natural natural natural natural naturalCooling system air air air air air airStarting system electric electric electric electric electric electricCONSUMPTIONConsumption g/kWh 272 272 272 272 260 260Consumption at 75% l/h 1,4 1,4 1,4 1,4 2,1 2,1Tank capacity l 24 24 21 21 24 24Running time at 75% h 17 17 14,9 14,9 11,7 11,7NOISE EMISSIONNoise level LWA dB(A) 98 98 83 83 99 99Acoustic pressure at 7 m dB(A) 72 72 57 57 73 73DIMENSIONS AND WEIGHTLength mm 930 930 970 970 930 930Width mm 555 555 580 580 555 555Height mm 800 800 800 800 800 800Weight (dry) kg 149 153 205 205 190 193STANDARD EQUIPMENTMagneto thermal protection Voltmeter Lifting hook

Sockets2 X 230V 16A2 X 115V 16A1 X 115V 32A

3 x 230V 16A1 x 400V 16A

2 X 230V 16A2 X 115V 16A1 X 115V 32A

2 x 230V 16A1 x 400V 16A

2 X 230V 16A2 X 115V 16A1 X 115V 32A

3 x 230V 16A1 x 400V 16A

PROTECTIONElectric protection IP 23 IP 23 IP 23 IP 23 IP 23 IP 23Socket protection IP 44 IP 44 IP 44 IP 44 IP 44 IP 44ACCESSORIESTransportation kit Remote control AMF panel Isometer protection Differential protection

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Page 25: Brochure Power systems UK Irlanda - Generator & … · pramac group PRAMAC is a young group of companies characterised by a wide product range in four Business Divisions, creating

48 49

P

Serie P Diesel:Potenza superiore a 9 kVA

MODELLO P11000 P11000 P12000CODICE PF113SYA PF113TYA PF113TZAGENERATORE DI CORRENTE 3000 RPMPOTENZA TRIFASE

Potenza LTP kW 9,5 12,63Potenza COP/LTP kVA 10,80/11,88 11,00/15,79Tensione Volt 400 400Frequenza Hz 50 50Fattore di potenza cosϕ 0,8 0,8POTENZA MONOFASE

Potenza LTP kW 10,69 6,53 9,38Potenza COP/LTP kVA 10,80/11,88 6,60/7,26 6,45/10,42Tensione Volt 230 230 230Frequenza Hz 50 50 50Fattore di potenza cosϕ 0,9 0,9 0,9MOTOREModello Yanmar Yanmar HatzTipo 3TNE68 3TNE68 2G40Cilindrata CC 784 784 997Cilindri 3 in linea 3 in linea 2 in lineaPotenza kW 12,9 12,9 15,4Carburante gasolio gasolio gasolioAspirazione naturale naturale naturaleRaffreddamento acqua acqua ariaAvviamento elettrico elettrico elettricoCONSUMOConsumo g/kWh 252 252 235Consumo al 75% l/h 3 3 2,3Capacità serbatoio l 30 30 17Autonomia al 75% h 10 10 7,4LIVELLO DI RUMOROSITÀPotenza acustica LWA dB(A) 94 94 98Pressione acustica a 7 m dB(A) 69 69 73DIMENSIONILunghezza mm 1360 1360 1003Larghezza mm 650 650 620Altezza mm 840 840 800Peso a secco kg 271 282 275DOTAZIONI DI SERIEProtezione oil-guard Protezione magnetotermica Protezione Isometer Protezione sovratemperatura Voltmetro Contaore Indicatore pressione olio Gancio di sollevamento

Prese2 x 230V 16A1 x 230V 32A

1 x 230V 16A1 x 230V 32A1 x 400V 32A

1 x 230V 16A1 x 230V 32A1 x 400V 16A

PROTEZIONEProtezione elettrica IP 23 IP 23 IP 23Protezione prese IP 44 IP 44 IP 44ACCESSORI A RICHIESTAKit trasporto Traino lento Comando a distanza (40m) Quadro intervento automatico Protezione differenziale Scaldiglia

P Class Diesel: Power greater than 9 kVa

Designed for professional and hard use, these generators are

hoping to spend their lifetimes supplying power to sites and

demanding applications. The optional wheels and handles

make it an ideal machine for conditions where it is vital that

the power source is manoeuvrable and reliable.

A simple and efficient tool that allows the easy moving of the machine, centrally positioned for best balance.

Complete with easy to read displays, incorporating superb design and practicality, allow the user complete control of all functions with assured safety. The folding panel door protects the panel when the machine is not in use.

Panel

With an easy lifting canopy hood, all engine maintenance is safe and easy.

Easy Access

Lifting Eye

GENERATOR SETS

C L A S S

GE

NE

RA

TO

R S

ET

S

D I E S E L

MODEL P11000 P11000 P12000CODE PF113SYA PF113TYA PF113TZAGENERATOR 3000 RPMTHREE-PHASE POWER

Power LTP kW 9,5 12,63Power COP/LTP kVA 10,80/11,88 11,00/15,79Voltage Volt 400 400Frequency Hz 50 50Power Factor cosϕ 0,8 0,8SINGLE-PHASE POWER

Power LTP kW 10,69 6,53 9,38Power COP/LTP kVA 10,80/11,88 6,60/7,26 6,45/10,42Voltage Volt 230 230 / 115 230 230Frequency Hz 50 50 50Power Factor cosϕ 0,9 0,9 0,9ENGINEModel Yanmar Yanmar HatzType 3TNE68 3TNE68 2G40Displacement CC 784 784 997Cylinder 3 in line 3 in line 2 in linePower kW 12,9 12,9 15,4Fuel gasoil gasoil gasoilAspiration natural natural naturalCooling system water water airStarting system electric electric electricCONSUMPTIONConsumption g/kWh 252 252 235Consumption at 75% l/h 3 3 2,3Tank capacity l 30 30 17Running time at 75% h 10 10 7,4NOISE EMISSIONNoise level LWA dB(A) 94 94 98Acoustic pressure at 7 m dB(A) 69 69 73DIMENSIONS AND WEIGHTLength mm 1360 1360 1003Width mm 650 650 620Height mm 840 840 800Weight (dry) kg 271 282 275STANDARD EQUIPMENTOil-guard system Magneto thermal protection Differential protectionIsometer protection Over temperature protection Voltmeter Hour meter Oil pressure indicator Lifting hook

Sockets2 X 230V 16A1 X 230V 32A

2 X 230V 16A1 X 230V 32A2 X 115V 16A2 X 115V 32A

1 x 230V 16A1 x 230V 32A1 x 400V 32A

1 x 230V 16A1 x 230V 32A1 x 400V 16A

PROTECTIONElectric protection IP 23 IP 23 IP 23Socket protection IP 44 IP 44 IP 44ACCESSORIESTransportation kit Job site trailer Remote control AMF panel Differential protection Pre-heater

PLEA

SE N

OTE:

Thi

s m

odel

is s

how

n w

ith a

n op

tiona

l tro

lley

kit w

hich

is n

ot fi

tted

as

stan

dard

Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com
Peter
for more information please contact:- Generator Associates Ltd - tel 01623 624 005 - [email protected] - www.generatorassociates.com