BOSTMARINE Type T/N Control Cable (Multi-Conductor) .................................................................... 3
BOSTMARINE Type T/N Control Cable (Multi-Conductor, Shielded) ..................................................... 5
BOSTMARINE Type T/N Control Cable (Shielded Triads) ...................................................................... 7
BOSTMARINE Type T/N Power Cable (Two Conductor) ........................................................................ 9
BOSTMARINE Type T/N Power Cable (Three Conductor) ..................................................................... 11
BOSTMARINE Type T/N Power Cable (Four Conductor) .......................................................................13
BOSTMARINE Type T/N Signal Cable (14 AWG) ...................................................................................15
BOSTMARINE Type T/N Signal Cable (16 AWG) ...................................................................................17
BOSTMARINE Type T/N Signal Cable (18 AWG) ...................................................................................19
BOSTMARINE Type T/N Signal Cable (20 AWG) ..................................................................................21
BOSTMARINE Type X Control Cable (Multi Conductor) ....................................................................... 23
BOSTMARINE Type X Power Cable (Two Conductor) .......................................................................... 25
BOSTMARINE Type X Power Cable (Three Conductor) ........................................................................ 27
BOSTMARINE Type X Power Cable (Four Conductor) ......................................................................... 29
BOSTMARINE Type X Signal Cable (16 AWG) .......................................................................................31
BOSTMARINE Type X Signal Cable (18 AWG) ...................................................................................... 33
BOSTMARINE Type X Signal Cable (20 AWG) ..................................................................................... 35
Table of Contents
A brand of the
BOSTMARINE Type T/N Control CableMulti-Conductor / Unarmored & Armored / 18, 16, and 14 AWG / 600V
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_C
ontr
ol C
able
_201
6-11
-17
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
Lloyd’sRegister
3
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_C
ontr
ol C
able
_201
6-11
-17
A brand of the
BOSTMARINE Type T/N Control CableMulti-Conductor / Unarmored & Armored / 18, 16, and 14 AWG / 600V
TPC Cable Type
Part Number*Number of Conductors
Stranding Type
Total**Insulation Thickness
in (mm)
JacketThickness
in (mm)
CableDiameter
(nom)in (mm)
Cable Weight (approx)Lbs/mft(Kg/km)
Armored Cable Diameter
(nom)Lbs/mft(Kg/km)
Aluminum Arm. Cable
Weight Lbs/mft(Kg/km)
Bronze Arm. Cable Weight
Lbs/mft(Kg/km)
18 AWG • 1.0 mm2
C18T/NT-2 036125* 2 7/15.2 .019 (0.48) .045 (1.14) 0.28 (7.1) 35 (52) 0.33 (8.4) 53 (79) 94 (140)
C18T/NT-3 036126* 3 7/15.2 .019 (0.48) .045 (1.14) 0.29 (7.4) 44 (65) 0.34 (8.6) 62 (92) 105 (156)
C18T/NT-4 036127* 4 7/15.2 .019 (0.48) .045 (1.14) 0.31 (7.9) 53 (79) 0.36 (9.1) 72 (107) 117 (174)
C18T/NT-7 029781* 7 7/15.2 .019 (0.48) .045 (1.14) 0.36 (9.1) 86 (128) 0.41 (10.4) 108 (160) 160 (238)
C18T/NT-10 030630* 10 7/15.2 .019 (0.48) .060 (1.52) 0.45 (11.4) 117 (174) 0.50 (12.7) 144 (214) 208 (310)
C18T/NT-16 350376* 16 7/15.2 .019 (0.48) .060 (1.52) 0.57 (14.5) 210 (312) 0.63 (16.0) 244 (363) 324 (482)
C18T/NT-20 350377* 20 7/15.2 .019 (0.48) .060 (1.52) 0.63 (16.0) 255 (379) 0.69 (17.5) 292 (434) 379 (564)
C18T/NT-24 036131* 24 7/15.2 .019 (0.48) .060 (1.52) 0.65 (16.5) 262 (390) 0.70 (17.8) 301 (448) 391 (582)
C18T/NT-30 036132* 30 7/15.2 .019 (0.48) .060 (1.52) 0.69 (17.5) 310 (461) 0.74 (18.8) 351 (522) 446 (664)
C18T/NT-37 036133* 37 7/15.2 .019 (0.48) .060 (1.52) 0.74 (18.8) 372 (554) 0.79 (20.1) 416 (619) 518 (771)
C18T/NT-44 036134* 44 7/15.2 .019 (0.48) .060 (1.52) 0.86 (21.8) 471 (701) 0.91 (23.1) 522 (777) 640 (952)
C18T/NT-61 036135* 61 7/15.2 .019 (0.48) .080 (2.03) 0.95 (24.1) 612 (911) 1.00 (25.4) 668 (994) 798 (1187)
16 AWG • 1.3 mm2
C16T/NT-2 030109* 2 7/19.2 .019 (0.48) .045 (1.14) 0.30 (7.6) 49 (73) 0.35 (8.9) 68 (101) 111 (165)
C16T/NT-3 036115* 3 7/19.2 .019 (0.48) .045 (1.14) 0.31 (7.9) 53 (79) 0.36 (9.1) 72 (107) 117 (174)
C16T/NT-4 030131* 4 7/19.2 .019 (0.48) .045 (1.14) 0.34 (8.6) 72 (107) 0.39 (9.9) 93 (138) 142 (211)
C16T/NT-7 030111* 7 7/19.2 .019 (0.48) .045 (1.14) 0.39 (9.9) 114 (170) 0.44 (11.2) 138 (205) 194 (289)
C16T/NT-10 030137* 10 7/19.2 .019 (0.48) .045 (1.14) 0.50 (12.7) 159 (237) 0.55 (14.0) 189 (281) 259 (385)
C16T/NT-16 030136* 16 7/19.2 .019 (0.48) .060 (1.52) 0.63 (16.0) 273 (406) 0.69 (17.5) 310 (461) 397 (591)
C16T/NT-20 030148* 20 7/19.2 .019 (0.48) .060 (1.52) 0.69 (17.5) 334 (497) 0.75 (19.1) 375 (558) 470 (699)
C16T/NT-24 030149* 24 7/19.2 .019 (0.48) .060 (1.52) 0.72 (18.3) 358 (533) 0.77 (19.6) 401 (597) 500 (744)
C16T/NT-30 030150* 30 7/19.2 .019 (0.48) .060 (1.52) 0.77 (19.6) 431 (641) 0.82 (20.8) 477 (710) 583 (868)
C16T/NT-37 030132* 37 7/19.2 .019 (0.48) .080 (2.03) 0.87 (22.1) 556 (827) 0.92 (23.4) 608 (905) 727 (1082)
C16T/NT-44 030180* 44 7/19.2 .019 (0.48) .080 (2.03) 0.96 (24.4) 652 (970) 1.01 (25.7) 709 (1055) 840 (1250)
C16T/NT-61 036140* 61 7/19.2 .019 (0.48) .080 (2.03) 1.07 (27.2) 816 (1214) 1.12 (28.7) 879 (1308) 1025 (1525)
14 AWG • 2.1 mm2
C14T/NT-2 036141* 2 7/24.2 .019 (0.48) .045 (1.14) 0.33 (8.4) 62 (92) 0.38 (9.7) 83 (124) 130 (193)
C14T/NT-3 036142* 3 7/24.2 .019 (0.48) .045 (1.14) 0.35 (8.9) 81 (121) 0.40 (10.2) 103 (153) 153 (228)
C14T/NT-4 036143* 4 7/24.2 .019 (0.48) .045 (1.14) 0.37 (9.4) 101 (150) 0.42 (10.7) 124 (185) 177 (263)
C14T/NT-7 030129* 7 7/24.2 .019 (0.48) .045 (1.14) 0.44 (11.2) 157 (234) 0.49 (12.4) 184 (274) 246 (366)
C14T/NT-10 030108* 10 7/24.2 .019 (0.48) .060 (1.52) 0.58 (14.7) 240 (357) 0.63 (16.0) 275 (409) 356 (530)
C14T/NT-16 030152* 16 7/24.2 .015 (.004) .060 (1.52) 0.69 (17.5) 366 (545) 0.75 (19.1) 407 (606) 502 (747)
C14T/NT-20 030609* 20 7/24.2 .015 (.004) .060 (1.52) 0.74 (18.8) 451 (671) 0.80 (20.3) 495 (737) 596 (887)
C14T/NT-24 030151* 24 7/24.2 .019 (0.48) .060 (1.52) 0.81 (20.6) 494 (735) 0.86 (21.8) 542 (806) 653 (972)
C14T/NT-30 036147* 30 7/24.2 .019 (0.48) .080 (2.03) 0.90 (22.9) 639 (951) 0.95 (24.1) 692 (1030) 815 (1213)
C14T/NT-37 030153* 37 7/24.2 .019 (0.48) .080 (2.03) 0.96 (24.4) 762 (1134) 1.01 (25.7) 818 (1217) 950 (1414)
C14T/NT-44 036148* 44 7/24.2 .019 (0.48) .080 (2.03) 1.08 (27.4) 901 (1341) 1.13 (28.7) 965 (1436) 1112 (1655)
C14T/NT-61 036149* 61 7/24.2 .019 (0.48) .080 (2.03) 1.14 (29.0) 1210 (1801) 1.19 (30.2) 1277 (1900) 1432 (2131)
*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).**NOTE: PVC/Nylon Insulation Thickness Inches(mm) - 0.015/.004(0.38/0.10) This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
4
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type T/N Control CableMulti-Conductor Shielded / Unarmored & Armored / 16 and 14 AWG / 600V
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
SHIELD: An aluminum/polyester tape with drain wire, 100% coverage, is applied over the cabled core.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_S
hiel
ded
Cont
rol C
able
_201
6-11
-17
Lloyd’sRegister
5
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_S
hiel
ded
Cont
rol C
able
_201
6-11
-17
BOSTMARINE Type T/N Control CableMulti-Conductor Shielded/ Unarmored & Armored / 16 and 14 AWG / 600V
TPC Cable Type
Part Number*Number of Conductors
Stranding Type
Total**Insulation Thickness
in (mm)
JacketThickness
in (mm)
CableDiameter
(nom)in (mm)
Cable Weight (approx)Lbs/mft(Kg/km)
Armored Cable Diameter
(nom)Lbs/mft(Kg/km)
Aluminum Arm. Cable
Weight Lbs/mft(Kg/km)
Bronze Arm. Cable Weight
Lbs/mft(Kg/km)
16 AWG • 1.3 mm2
C16(OS)T/NT-2 2 7/19.2 .019 (0.48) .045 (1.14) 0.31 (7.9) 58 (86) 0.37 (9.4) 77 (115) 122 (182)
C16(OS)T/NT-3 3 7/19.2 .019 (0.48) .045 (1.14) 0.33 (8.4) 63 (94) 0.39 (9.9) 83 (124) 130 (193)
C16(OS)T/NT-4 4 7/19.2 .019 (0.48) .045 (1.14) 0.35 (8.9) 82 (122) 0.41 (10.4) 103 (153) 153 (228)
C16(OS)T/NT-7 030631* 7 7/19.2 .019 (0.48) .045 (1.14) 0.42 (10.7) 124 (185) 0.48 (12.2) 150 (305) 209 (311)
C16(OS)T/NT-10 030632* 10 7/19.2 .019 (0.48) .045 (1.14) 0.55 (14.0) 169 (251) 0.58 (14.7) 200 (418) 273 (406)
C16(OS)T/NT-16 030633* 16 7/19.2 .019 (0.48) .060 (1.52) 0.63 (16.0) 281 (418) 0.69 (17.5) 319 (475) 406 (604)
C16(OS)T/NT-20 030634* 20 7/19.2 .019 (0.48) .060 (1.52) 0.70 (17.8) 343 (510) 0.76 (19.3) 385 (573) 480 (714)
C16(OS)T/NT-24 036753* 24 7/19.2 .019 (0.48) .060 (1.52) 0.76 (19.3) 371 (552) 0.82 (20.8) 416 (619) 521 (775)
C16(OS)T/NT-30 30 7/19.2 .019 (0.48) .060 (1.52) 0.81 (20.6) 444 (661) 0.87 (22.1) 492 (733) 602 (896)
C16(OS)T/NT-37 030635* 37 7/19.2 .019 (0.48) .080 (2.03) 0.91 (23.1) 569 (847) 0.97 (24.6) 623 (927) 747 (1112)
C16(OS)T/NT-44 030180* 44 7/19.2 .019 (0.48) .080 (2.03) 1.03 (26.2) 666 (991) 1.09 (27.7) 727 (1082) 867 (1290)
C16(OS)T/NT-61 036140* 61 7/19.2 .019 (0.48) .080 (2.03) 1.13 (28.7) 830 (1235) 1.19 (30.2) 896 (1333) 1049 (1561)
14 AWG • 2.1 mm2
C14(OS)T/NT-2 036141* 2 7/24.2 .019 (0.48) .045 (1.14) 0.34 (8.6) 75 (112) 0.40 (10.2) 96 (143) 145 (216)
C14(OS)T/NT-3 036142* 3 7/24.2 .019 (0.48) .045 (1.14) 0.36 (9.1) 94 (140) 0.42 (10.7) 116 (173) 167 (248)
C14(OS)T/NT-4 036143* 4 7/24.2 .019 (0.48) .045 (1.14) 0.42 (10.7) 115 (171) 0.48 (12.2) 140 (208) 219 (326)
C14(OS)T/NT-7 036745* 7 7/24.2 .019 (0.48) .045 (1.14) 0.46 (11.6) 171 (254) 0.52 (13.2) 199 (296) 273 (406)
C14(OS)T/NT-10 030648* 10 7/24.2 .019 (0.48) .060 (1.52) 0.58 (14.7) 254 (377) 0.64 (16.3) 206 (307) 369 (549)
C14(OS)T/NT-16 350374* 16 7/24.2 .015 (.004) .060 (1.52) 0.63 (16.0) 378 (562) 0.75 (19.1) 419 (623) 514 (765)
C14(OS)T/NT-20 350375* 20 7/24.2 .015 (.004) .060 (1.52) 0.71 (18.0) 462 (687) 0.82 (20.8) 507 (754) 612 (911)
C14(OS)T/NT-24 24 7/24.2 .019 (0.48) .060 (1.52) 0.84 (21.3) 510 (759) 0.90 (22.9) 560 (833) 675 (1004)
C14(OS)T/NT-30 30 7/24.2 .019 (0.48) .080 (2.03) 0.93 (23.6) 655 (975) 0.99 (25.1) 710 (1056) 837 (1245)
C14(OS)T/NT-37 37 7/24.2 .019 (0.48) .080 (2.03) 1.00 (25.4) 778 (1158) 1.06 (26.9) 837 (1245) 972 (1446)
C14(OS)T/NT-44 036148* 44 7/24.2 .019 (0.48) .080 (2.03) 1.13 (28.7) 917 (1364) 1.19 (30.2) 983 (1463) 1137 (1692)
C14(OS)T/NT-61 036149* 61 7/24.2 .019 (0.48) .080 (2.03) 1.18 (30.0) 1226 (1824) 1.24 (31.5) 1295 (1927) 1456 (2167)
*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).**NOTE: PVC/Nylon Insulation Thickness Inches(mm) - 0.015/.004(0.38/0.10) This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
6
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type T/N Control CableIndividual & Overall Shielded Triads / Unarmored & Armored / 18, 16, and 14 AWG / 600V
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_S
hiel
ded
Tria
ds_2
016-
11-1
7
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
TRIAD SHIELD: Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
7
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_S
hiel
ded
Tria
ds_2
016-
11-1
7
BOSTMARINE Type T/N Control CableIndividual & Overall Shielded Triads/ Unarmored & Armored / 18, 16 and 14 AWG / 600V
TPC Cable TypePart
Number*Number of
TriadsStranding
Type
Total**Insulation Thickness
in (mm)
JacketThickness
in (mm)
CableDiameter
(nom)in (mm)
Cable Weight (approx)Lbs/mft(Kg/km)
Armored Cable Diameter
(nom)Lbs/mft(Kg/km)
Aluminum Arm. Cable
Weight Lbs/mft(Kg/km)
Bronze Arm. Cable Weight
Lbs/mft(Kg/km)
18 AWG • 1.0 mm2
TT18(OS)T/NT-1 350370 1 7/15.2 .019 (0.48) .045 (1.14) 0.31 (7.9) 56 (83) 0.37 (9.4) 75 (112) 119 (177)
TT18(IS-OS)T/NT-3 350371 3 7/15.2 .019 (0.48) .060 (1.52) 0.59 (15.0) 174 (259) 0.65 (16.5) 209 (311) 291 (433)
TT18(IS-OS)T/NT-6 350372 6 7/15.2 .019 (0.48) .060 (1.52) 0.76 (19.3) 294 (437) 0.82 (20.8) 339 (504) 444 (661)
TT18(IS-OS)T/NT-12 350373 12 7/15.2 .019 (0.48) .080 (2.03) 1.05 (26.7) 567 (844) 1.11 (28.2) 629 (936) 772 (1149)
16 AWG • 1.3 mm2
TT16(IS-OS)T/NT-1 350366 1 7/19.2 .019 (0.48) .045 (1.14) 0.33 (8.4) 70 (104) 0.39 (9.9) 91 (135) 138 (205)
TT16(IS-OS)T/NT-3 350367 3 7/19.2 .019 (0.48) .060 (1.52) 0.64 (16.3) 222 (330) 0.70 (17.8) 260 (387) 349 (519)
TT16(IS-OS)T/NT-6 350368 6 7/19.2 .019 (0.48) .060 (1.52) 0.84 (21.3) 380 (565) 0.90 (22.9) 430 (640) 555 (826)
TT16(IS-OS)T/NT-12 350369 12 7/19.2 .019 (0.48) .080 (2.03) 1.15 (29.2) 683 (1016) 1.21 (30.7) 751 (1117) 907 (1350)
14 AWG • 2.1 mm2
TT14(IS-OS)T/NT-1 350362 1 7/24.2 .019 (0.48) .045 (1.14) 0.36 (9.1) 93 (138) 0.42 (10.7) 115 (171) 166 (247)
TT14(IS-OS)T/NT-3 350363 3 7/24.2 .019 (0.48) .060 (1.52) 0.70 (17.8) 294 (437) 0.76 (19.3) 336 (500) 431 (641)
TT14(IS-OS)T/NT-6 350364 6 7/24.2 .019 (0.48) .060 (1.52) 0.96 (24.4) 558 (830) 1.02 (25.9) 614 (914) 745 (1109)
TT14(IS-OS)T/NT-12 350365 12 7/24.2 .019 (0.48) .080 (2.03) 1.26 (32.0) 1007 (1498) 1.32 (33.5) 1081 (1609) 1251 (1861)
*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B).**NOTE: PVC/Nylon Insulation Thickness Inches(mm) - 0.015/.004(0.38/0.10) This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
8
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type T/N Power CableTwo Conductor Power Distribution / Unarmored & Armored / 14 AWG to 500 MCM / 600V
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_2
C_Po
wer
_201
6-11
-21
Lloyd’sRegister
9
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_2
C_Po
wer
_201
6-11
-21
BOSTMARINE Type T/N Power CableTwo Conductor/ Unarmored & Armored / 14 AWG to 500 MCM / 600V
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)Stranding Type
PVC/NylonInsulation Thickness
in (mm)
JacketThickness
in (mm)
Cable Diameter(nominal)in (mm)
Cable Weight(approximate)
Lbs/mft (Kg/km)
UNARMORED
DT/NT-4 030103 14 (2.1) 7/24.2 .015/.004 (0.38/0.10) 0.045 (1.14) 0.33 (8.4) 66 (98)
DT/NT-6 030123 12 (3.3) 7/30.5 .015/.004 (0.38/0.10) 0.045 (1.14) 0.37 (9.4) 88 (131)
DT/NT-10 030114 10 (5.3) 7/38.5 .020/.004 (0.51/0.10) 0.045 (1.14) 0.43 (10.9) 133 (198)
DT/NT-16 030138 8 (8.4) 7/48.6 .030/.005 (0.76/0.13) 0.060 (1.52) 0.58 (14.7) 216 (321)
DT/NT-26 030139 6 (13.3) 7/61.2 .030/.005 (0.76/0.13) 0.060 (1.52) 0.65 (16.5) 311 (463)
DT/NT-41 030182 4 (21.1) 7/77.2 .040/.006 (1.02/0.15) 0.060 (1.52) 0.80 (20.3) 479 (713)
DT/NT-66 036090 2 (33.6) 7/97.4 .040/.006 (1.02/0.15) 0.080 (2.03) 0.97 (24.6) 727 (1082)
DT/NT-83 036091 1 (42.4) 19/66.4 .050/.007 (1.27/0.18) 0.080 (2.03) 1.00 (25.4) 933 (1388)
DT/NT-106 036092 1/0 (53.5) 19/74.5 .050/.007 (.127/0.18) 0.080 (2.03) 1.18 (30.0) 1110 (1652)
DT/NT-133 036093 2/0 (67.4) 19/83.7 .050/.007 (1.27/0.18) 0.080 (2.03) 1.27 (32.3) 1323 (1969)
DT/NT-168 036094 3/0 (85.0) 19/94.0 .050/.007 (1.27/0.18) 0.080 (2.03) 1.38 (35.1) 1602 (2384)
DT/NT-212 036095 4/0 (107.2) 19/105.5 .050/.007 (1.27/0.18) 0.080 (2.03) 1.56 (39.6) 2122 (3158)
DT/NT-250 036096 250 (127.0) 37/82.2 .060/.008 (1.52/0.20) 0.080 (2.03) 1.62 (41.1) 2337 (3478)
DT/NT-300 036097 300 (152.0) 37/90.0 .060/.008 (1.52/0.20) 0.110 (2.79) 1.80 (45.7) 2851 (4243)
DT/NT-350 036049 350 (177.0) 37/97.3 .060/.008 (1.52/0.20) 0.110 (2.79) 1.90 (48.3) 3303 (4915)
DT/NT-400 036098 400 (203.0) 37/104.0 .060/.008 (1.52/0.20) 0.110 (2.79) 2.08 (52.8) 3662 (5450)
DT/NT-500 036099 500 (253.0) 37/116.2 .060/.008 (1.52/0.20) 0.110 (2.79) 2.17 (55.1) 4497 (6692)
*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
JacketThickness
in (mm)
Armored CableDiameterin (mm)
Aluminum Armor Cable Weight
Lbs/mft (Kg/km)
Bronze ArmorCable Weight
Lbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
DT/NT-4 030103* 14 (2.1) 7/24.2 .015/.004 (0.38/0.10) 0.045 (1.14) 0.38 (9.7) 86 (128) 132 (196)
DT/NT-6 030123* 12 (3.3) 7/30.5 .015/.004 (0.38/0.10) 0.045 (1.14) 0.42 (10.7) 110 (164) 162 (240)
DT/NT-10 030114* 10 (5.3) 7/38.5 .020/.004 (0.51/0.10) 0.045 (1.14) 0.48 (12.5) 159 (237) 218 (324)
DT/NT-16 030138* 8 (8.4) 7/48.6 .030/.005 (0.76/0.13) 0.060 (1.52) 0.63 (16.0) 250 (372) 329 (490)
DT/NT-26 030139* 6 (13.3) 7/61.2 .030/.005 (0.76/0.13) 0.060 (1.52) 0.70 (17.8) 351 (522) 437 (650)
DT/NT-41 030182* 4 (21.1) 7/77.2 .040/.006 (1.02/0.15) 0.060 (1.52) 0.85 (21.6) 530 (789) 633 (942)
DT/NT-66 036090* 2 (33.6) 7/97.4 .040/.006 (1.02/0.15) 0.080 (2.03) 1.02 (27.2) 791 (1177) 912 (1357)
DT/NT-83 036091* 1 (42.4) 19/66.4 .050/.007 (1.27/0.18) 0.080 (2.03) 1.05 (30.8) 991 (1475) 1124 (1673)
DT/NT-106 036092* 1/0 (53.5) 19/74.5 .050/.007 (1.27/0.18) 0.080 (2.03) 1.23 (32.8) 1178 (1753) 1334 (1985)
DT/NT-133 036093* 2/0 (67.4) 19/83.7 .050/.007 (1.27/0.18) 0.080 (2.03) 1.32 (35.8) 1396 (2077) 1564 (2327)
DT/NT-168 036094* 3/0 (85.0) 19/94.0 .050/.007 (1.27/0.18) 0.080 (2.03) 1.43 (38.1) 1681 (2501) 1863 (2772)
DT/NT-212 036095* 4/0 (107.2) 19/105.5 .050/.007 (1.27/0.18) 0.080 (2.03) 1.61 (41.7) 2211 (3290) 2416 (3595)
DT/NT-250 036096* 250 (127.0) 37/82.2 .060/.008 (1.52/0.20) 0.080 (2.03) 1.67 (47.0) 2429 (3614) 2643 (3933)
DT/NT-300 036097* 300 (152.0) 37/90.0 .060/.008 (1.52/0.20) 0.110 (2.79) 1.85 (49.8) 2953 (4394) 3190 (4747)
DT/NT-350 036049* 350 (177.0) 37/97.3 .060/.008 (1.52/0.20) 0.110 (2.79) 1.95 (49.6) 3411 (5076) 3660 (5446)
DT/NT-400 036098* 400 (203.0) 37/104.0 .060/.008 (1.52/0.20) 0.110 (2.79) 2.13 (54.1) 3780 (5625) 4053 (6031)
DT/NT-500 036099* 500 (253.0) 37/116.2 .060/.008 (1.52/0.20) 0.110 (2.79) 2.22 (56.4) 4620 (6875) 4904 (7297)
10
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type T/N Power CableThree Conductor Power Distribution / Unarmored & Armored / 14 AWG to 750 MCM / 600V
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_3
C_Po
wer
_201
6-11
-21
Lloyd’sRegister
11
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_3
C_Po
wer
_201
6-11
-21
BOSTMARINE Type T/N Power CableThree Conductor/ Unarmored & Armored / 14 AWG to 750 MCM / 600V
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)Stranding Type
PVC/NylonInsulation Thickness
in (mm)
JacketThickness
in (mm)
Cable Diameter(nominal)in (mm)
Cable Weight(approximate)
Lbs/mft (Kg/km)
UNARMORED
TT/NT-4 030101 14 (2.1) 7/24.2 .015/.004 (.038/0.10) 0.045 (1.14) 0.35 (8.9) 86 (128)
TT/NT-6 030102 12 (3.3) 7/30.5 .015/.004 (.038/0.10) 0.045 (1.14) 0.39 (9.9) 120 (179)
TT/NT-10 030107 10 (5.3) 7/38.5 .020/.004 (.051/0.10) 0.045 (1.14) 0.46 (11.7) 171 (254)
TT/NT-16 030106 8 (8.4) 7/48.6 .030/.005 (0.76/0.13) 0.060 (1.52) 0.61 (15.5) 301 (448)
TT/NT-26 030105 6 (13.3) 7/61.2 .030/.005 (0.76/0.13) 0.060 (1.52) 0.69 (17.5) 406 (604)
TT/NT-41 030110 4 (21.1) 7/77.2 .040/.006 (1.02/0.15) 0.080 (2.03) 0.84 (21.3) 664 (988)
TT/NT-66 030112 2 (33.6) 7/97.4 .040/.006 (1.02/0.15) 0.080 (2.03) 1.02 (25.9) 980 (1458)
TT/NT-83 036102 1 (42.4) 19/66.4 .050/.007 (.127/0.18) 0.080 (2.03) 1.16 (29.5) 1228 (1827)
TT/NT-106 030178 1/0 (53.5) 19/74.5 .050/.007 (.127/0.18) 0.080 (2.03) 1.24 (31.5) 1557 (2317)
TT/NT-133 036103 2/0 (67.4) 19/83.7 .050/.007 (.127/0.18) 0.080 (2.03) 1.36 (34.5) 1828 (2720)
TT/NT-168 036104 3/0 (85.0) 19/94.0 .050/.007 (.127/0.18) 0.080 (2.03) 1.45 (36.8) 2244 (3339)
TT/NT-212 036105 4/0 (107.2) 19/105.5 .050/.007 (.127/0.18) 0.080 (2.03) 1.59 (40.4) 2773 (4127)
TT/NT-250 036106 250 (127.0) 37/82.2 .060/.008 (1.52/0.20) 0.110 (2.79) 1.80 (45.7) 3360 (5000)
TT/NT-300 036107 300 (152.0) 37/90.0 .060/.008 (1.52/0.20) 0.110 (2.79) 1.91 (48.5) 3920 (5834)
TT/NT-350 036108 350 (177.0) 37/97.3 .060/.008 (1.52/0.20) 0.110 (2.79) 2.05 (52.1) 4550 (6771)
TT/NT-400 036109 400 (203.0) 37/104.0 .060/.008 (1.52/0.20) 0.110 (2.79) 2.22 (56.4) 5133 (7639)
TT/NT-500 036110 500 (253.0) 37/116.2 .060/.008 (1.52/0.20) 0.110 (2.79) 2.45 (62.2) 6472 (9631)
TT/NT-600 036111 600 (304.0) 61/99.2 .070/.009 (1.78/0.22) 0.110 (2.79) 2.52 (64.0) 7375 (10,975)
TT/NT-750 036112 750 (380.0) 61/110.9 .070/0.009 (1.78/0.22) 0.110 (2.79) 2.83 ( 71.9) 9200 (13,691)
*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
JacketThickness
in (mm)
Armored CableDiameterin (mm)
Aluminum Armor Cable Weight
Lbs/mft (Kg/km)
Bronze ArmorCable Weight
Lbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
TT/NT-4 030101* 14 (2.1) 7/24.2 .015/.004 (.038/0.10) 0.045 (1.14) 0.38 (9.7) 107 (159) 156 (232)
TT/NT-6 030102* 12 (3.3) 7/30.5 .015/.004 (.038/0.10) 0.045 (1.14) 0.44 (11.2) 143 (213) 198 (295)
TT/NT-10 030107* 10 (5.3) 7/38.5 .020/.004 (.051/0.10) 0.045 (1.14) 0.51 (13.0) 198 (295) 262 (390)
TT/NT-16 030106* 8 (8.4) 7/48.6 .030/.005 (0.76/0.13) 0.060 (1.52) 0.66 (16.8) 337 (501) 419 (623)
TT/NT-26 030105* 6 (13.3) 7/61.2 .030/.005 (0.76/0.13) 0.060 (1.52) 0.74 (18.8) 446 (664) 539 (802)
TT/NT-41 030110* 4 (21.1) 7/77.2 .040/.006 (1.02/0.15) 0.080 (2.03) 0.89 (22.6) 713 (1061) 825 (1228)
TT/NT-66 030112* 2 (33.6) 7/97.4 .040/.006 (1.02/0.15) 0.080 (2.03) 1.07 (27.2) 1039 (1626) 1174 (1747)
TT/NT-83 036102* 1 (42.4) 19/66.4 .050/.007 (.127/0.18) 0.080 (2.03) 1.21 (30.8) 1295 (1927) 1448 (2155)
TT/NT-106 030178* 1/0 (53.5) 19/74.5 .050/.007 (.127/0.18) 0.080 (2.03) 1.29 (32.8) 1628 (2422) 1792 (2666)
TT/NT-133 036103* 2/0 (67.4) 19/83.7 .050/.007 (.127/0.18) 0.080 (2.03) 1.41 (35.8) 1906 (2836) 2085 (3102)
TT/NT-168 036104* 3/0 (85.0) 19/94.0 .050/.007 (.127/0.18) 0.080 (2.03) 1.50 (38.1) 2327 (3463) 2518 (3747)
TT/NT-212 036105* 4/0 (107.2) 19/105.5 .050/.007 (.12/0.18) 0.080 (2.03) 1.64 (41.7) 2864 (4262) 3073 (4573)
TT/NT-250 036106* 250 (127.0) 37/82.2 .060/.008 (1.52/0.20) 0.110 (2.79) 1.85 (47.0) 3462 (5151) 3699 (5504)
TT/NT-300 036107* 300 (152.0) 37/90.0 .060/.008 (1.52/0.20) 0.110 (2.79) 1.96 (49.8) 4029 (5995) 4280 (6369)
TT/NT-350 036108* 350 (177.0) 37/97.3 .060/.008 (1.52/0.20) 0.110 (2.79) 2.10 (53.4) 4666 (6943) 4935 (7343)
TT/NT-400 036109* 400 (203.0) 37/104.0 .060/.008 (1.52/0.20) 0.110 (2.79) 2.27 (57.7) 5259 (7825) 5550 (8258)
TT/NT-500 036110* 500 (253.0) 37/116.2 .060/.008 (1.52/0.20) 0.110 (2.79) 2.50 (63.5) 6611 (9837) 6932 (10,315)
TT/NT-600 036111* 600 (304.0) 61/99.2 .070/.009 (1.78/0.22) 0.110 (2.79) 2.57 (65.3) 7518 (11,187) 7847 (11,676)
TT/NT-750 036112* 750 (380.0) 61/110.9 .070/0.009 (1.78/0.22) 0.110 (2.79) 2.88 (73.2) 9360 (13,928) 9730 (14,478)
12
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type T/N Power CableFour Conductor Power Distribution / Unarmored & Armored / 14 AWG to 750 MCM / 600V
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_4
C_Po
wer
_201
6-11
-21
Lloyd’sRegister
13
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_4
C_Po
wer
_201
6-11
-21
BOSTMARINE Type T/N Power CableFour Conductor/ Unarmored & Armored / 14 AWG to 750 MCM / 600V
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)Stranding Type
PVC/NylonInsulation Thickness
in (mm)
JacketThickness
in (mm)
Cable Diameter(nominal)in (mm)
Cable Weight(approximate)
Lbs/mft (Kg/km)
UNARMORED
FT/NT-4 030104 14 (2.1) 7/24.2 0.015/.004 (0.38/0.10) 0.045 (1.14) 0.39 (9.9) 151 (225)
FT/NT-6 030130 12 (3.3) 7/30.5 0.015/.004 (0.38/0.10) 0.045 (1.14) 0.43 (10.9) 225 (335)
FT/NT-10 030128 10 (5.3) 7/38.5 0.020/.004 (0.51/0.10) 0.045 (1.14) 0.51 (13.0) 366 (545)
FT/NT-16 030135 8 (8.4) 7/48.6 0.030/.005 (0.76/0.13) 0.060 (1.52) 0.66 (16.8) 536 (798)
FT/NT-26 030134 6 (13.3) 7/61.2 0.030/.005 (0.76/0.13) 0.060 (1.52) 0.77 (19.6) 878 (1307)
FT/NT-41 030133 4 (21.1) 7/77.2 0.040/.006 (1.02/0.15) 0.080 (2.03) 0.99 (25.1) 1268 (1887)
FT/NT-66 030179 2 (33.6) 7/97.4 0.040/.006 (1.02/0.15) 0.080 (2.03) 1.13 (28.7) 1598 (2378)
FT/NT-83 036114 1 (42.4) 19/66.4 0.050/.007 (1.27/0.18) 0.080 (2.03) 1.27 (32.3) 1924 (2863)
FT/NT-106 036115 1/0 (53.5) 19/74.5 0.050/.007 (1.27/0.18) 0.080 (2.03) 1.38 (35.1) 2374 (3533)
FT/NT-133 036116 2/0 (67.4) 19/83.7 0.050/.007 (1.27/0.18) 0.080 (2.03) 1.49 (37.8) 2569 (3823)
FT/NT-168 036117 3/0 (85.0) 19/94.0 0.050/.007 (1.27/0.18) 0.080 (2.03) 1.61 (40.9) 2850 (4241)
FT/NT-212 030177 4/0 (107.2) 19/105.5 0.050/.007 (1.27/0.18) 0.110 (2.79) 1.82 (46.2) 3650 (5432)
FT/NT-250 036118 250 (127.0) 37/82.2 0.060/.008 (1.52/0.20) 0.110 (2.79) 1.98 (50.3) 4319 (6427)
FT/NT-300 036119 300 (152.0) 37/90.0 0.060/.008 (1.52/0.20) 0.110 (2.79) 2.11 (53.6) 5051 (7517)
FT/NT-350 036120 350 (177.0) 37/97.3 0.060/.008 (1.52/0.20) 0.110 (2.79) 2.34 (59.4) 5866 (8730)
FT/NT-400 036121 400 (203.0) 37/104.0 0.060/.008 (1.52/0.20) 0.110 (2.79) 2.46 (62.5) 6623 (9856)
FT/NT-500 036122 500 (253.0) 37/116.2 0.060/.008 (1.52/0.20) 0.110 (2.79) 2.56 (65.0) 8086 (12,033)
FT/NT-600 036123 600 (304.0) 61/99.2 0.070/.009 (1.78/0.23) 0.140 (3.56) 2.87 (72.9) 9657 (14,371)
FT/NT-750 036124 750 (380.0) 61/110.9 0.070/.009 (1.78/0.23) 0.140 (3.56) 3.11 ( 79.0) 11,949 (17,782)
*NOTE: For aluminum armored versions, add an A (ex. 030104A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)
Stranding Type
PVC/Nylon Insulation Thickness
in (mm)
JacketThickness
in (mm)
Armored CableDiameterin (mm)
Aluminum Armor Cable Weight
Lbs/mft (Kg/km)
Bronze ArmorCable Weight
Lbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
FT/NT-4 030104* 14 • 2.1 7/24.2 0.015/.004 (0.38/0.10) .045 (1.14) 0.44 (11.2) 174 (259) 229 (341)
FT/NT-6 030130* 12 • 3.3 7/30.5 0.015/.004 (0.38/0.10) .045 (1.14) 0.48 (12.2) 251 (373) 310 (461)
FT/NT-10 030128* 10 • 5.3 7/38.5 0.020/.004 (0.51/0.10) .045 (1.14) 0.56 (14.2) 396 (589) 466 (693)
FT/NT-16 030135* 8 • 8.4 7/48.6 0.030/.005 (0.76/0.13) .060 (1.52) 0.71 (18.1) 575 (856) 664 (988)
FT/NT-26 030134* 6 • 13.3 7/61.2 0.030/.005 (0.76/0.13) .060 (1.52) 0.82 (20.9) 923 (1373) 1026 (1527)
FT/NT-41 030133* 4 • 21.1 7/77.2 0.040/.006 (1.02/0.15) .080 (2.03) 1.04 (26.4) 1325 (1971) 1457 (2168)
FT/NT-66 030179* 2 • 33.6 7/97.4 0.040/.006 (1.02/0.15) .080 (2.03) 1.18 (30.0) 1663 (2475) 1813 (2698)
FT/NT-83 036114* 1 • 42.4 19/66.4 0.050/.007 (1.27/0.18) .080 (2.03) 1.32 (33.8) 1997 (2972) 2165 (3222)
FT/NT-106 036115* 1/0 • 53.5 19/74.5 0.050/.007 (1.27/0.18) .080 (2.03) 1.43 (36.3) 2453 (3650) 2635 (3921)
FT/NT-133 036116* 2/0 • 67.4 19/83.7 0.050/.007 (1.27/0.18) .080 (2.03) 1.54 (39.1) 2654 (3949) 2850 (4241)
FT/NT-168 036117* 3/0 • 85.0 19/94.0 0.050/.007 (1.27/0.18) .080 (2.03) 1.66 (42.2) 2942 (4378) 3154 (4693)
FT/NT-212 030177* 4/0 • 107.2 19/105.5 0.050/.007 (1.27/0.18) .110 (2.79) 1.87 (47.5) 3753 (5584) 3993 (5942)
FT/NT-250 036118* 250 • 127.0 37/82.2 0.060/.008 (1.52/0.20) .110 (2.79) 2.03 (51.6) 4431 (6593) 4691 (6980)
FT/NT-300 036119* 300 • 152.0 37/90.0 0.060/.008 (1.52/0.20) .110 (2.79) 2.16 (54.9) 5171 (7694) 5447 (8105)
FT/NT-350 036120* 350 • 177.0 37/97.3 0.060/.008 (1.52/0.20) .110 (2.79) 2.39 (60.7) 5999 (8927) 6305 (9382)
FT/NT-400 036121* 400 • 203.0 37/104.0 0.060/.008 (1.52/0.20) .110 (2.79) 2.51 (63.8) 6762 (10,062) 7084 (10,541)
FT/NT-500 036122* 500 • 253.0 37/116.2 0.060/.008 (1.52/0.20) .110 (2.79) 2.61 (66.3) 8235 (12,254) 8566 (12,746)
FT/NT-600 036123* 600 • 304.0 61/99.2 0.070/.009 (1.78/0.23) .140 (3.56) 2.92 (74.2) 9819 (14,611) 10,194 (15,169)
FT/NT-750 036124* 750 • 380.0 61/110.9 0.070/.009 (1.78/0.23) .140 (3.56) 3.16 (80.3) 12,125 (18,042) 12,531 (18,646)
14
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 14 AWG 2.1 mm2 / 600V
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_1
4AW
G_S
igna
l_20
16-1
1-22
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
15
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_1
4AW
G_S
igna
l_20
16-1
1-22
BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 14 AWG 2.1 mm2 / 600V
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
Jacket Thicknessin (mm)
Cable Diameter (nominal)in (mm)
Cable Weight (approximate)
Lbs/mft (Kg/km)
UNARMORED
TP14(IS-OS)T/NT-1 350356 1 7/24.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.340 (8.6) 73 (109)
TP14(IS-OS)T/NT-2 030186 2 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.575 (14.6) 175 (260)
TP14(IS-OS)T/NT-3 350358 3 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.605 (15.4) 228 (339)
TP14(IS-OS)T/NT-4 030188 4 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.665 (16.9) 282 (420)
TP14(IS-OS)T/NT-6 030189 6 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.790 (20.1) 392 (583)
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
Jacket Thicknessin (mm)
Armored Cable Diameterin (mm)
Aluminum Armored Cable
WeightLbs/mft (Kg/km)
BronzeArmored Cable
WeightLbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
TP14(IS-OS)T/NT-1 350356* 1 7/24.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.400 (10.2) 94 (140) 143 (213)
TP14(IS-OS)T/NT-2 030186* 2 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.635 (16.1) 210 (312) 290 (432)
TP14(IS-OS)T/NT-3 350358* 3 7/24.2 0.015/0.004 ( 0.38/0.10) 0.060 (1.52) 0.665 (16.9) 264 (393) 348 (518)
TP14(IS-OS)T/NT-4 030188* 4 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.725 (18.4) 322 (479) 414 (616)
TP14(IS-OS)T/NT-6 030189* 6 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.850 (21.6) 439 (653) 547 (814)
*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
16
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 16 AWG 1.3 mm2 / 600V
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_1
6AW
G_S
igna
l_20
16-1
1-22
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
17
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_1
6AW
G_S
igna
l_20
16-1
1-22
BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 16 AWG 1.3 mm2 / 600V
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
Jacket Thicknessin (mm)
Cable Diameter (nominal)in (mm)
Cable Weight (approximate)
Lbs/mft (Kg/km)
UNARMORED
TP16(OS)T/NT-1 030160 1 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.29 (7.4) 49 (72)
TP16(IS-OS)T/NT-2 030162 2 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.43 (11.0) 58 (86)
TP16(IS-OS)T/NT-3 036194 3 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.46 (11.7) 124 (184)
TP16(IS-OS)T/NT-4 030164 4 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.50 (12.8) 155 (231)
TP16(IS-OS)T/NT-5 036196 5 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.58 (14.8) 205 (306)
TP16(IS-OS)T/NT-6 030165 6 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.63 (16.1) 240 (356)
TP16(IS-OS)T/NT-7 036198 7 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.63 (16.1) 268 (398)
TP16(IS-OS)T/NT-8 030166 8 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.69 (17.4) 300 (446)
TP16(IS-OS)T/NT-9 036200 9 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.74 (18.8) 337 (502)
TP16(IS-OS)T/NT-10 036201 10 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.81 (20.4) 373 (555)
TP16(IS-OS)T/NT-11 036202 11 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.88 (22.2) 401 (597)
TP16(IS-OS)T/NT-12 036203 12 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.88 (22.2) 466 (693)
TP16(IS-OS)T/NT-13 036204 13 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 501 (746)
TP16(IS-OS)T/NT-14 036205 14 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 530 (788)
TP16(IS-OS)T/NT-15 030161 15 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.6) 566 (842)
TP16(IS-OS)T/NT-16 036207 16 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.6) 594 (884)
TP16(IS-OS)T/NT-17 036208 17 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 630 (938)
TP16(IS-OS)T/NT-18 036209 18 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 659 (981)
TP16(IS-OS)T/NT-19 036210 19 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 687 (1023)
TP16(IS-OS)T/NT-20 030163 20 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 724 (1077)
TP16(IS-OS)T/NT-21 036212 21 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 752 (1119)
TP16(IS-OS)T/NT-22 036213 22 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.12 (28.5) 789 (1174)
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
Jacket Thicknessin (mm)
Armored Cable Diameterin (mm)
Aluminum Armored Cable
WeightLbs/mft (Kg/km)
BronzeArmored Cable
WeightLbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
TP16(OS)T/NT-1 030160* 1 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.34 (8.7) 67 (100) 108 (161)
TP16(IS-OS)T/NT-2 030162* 2 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.48 (12.2) 84 (125) 143 (213)
TP16(IS-OS)T/NT-3 036194* 3 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.51 (13.0) 151 (225) 215 (320)
TP16(IS-OS)T/NT-4 030164* 4 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.55 (14.0) 185 (275) 253 (376)
TP16(IS-OS)T/NT-5 036196* 5 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.63 (16.0) 239 (356) 318 (473)
TP16(IS-OS)T/NT-6 030165* 6 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.68 (17.3) 277 (412) 362 (539)
TP16(IS-OS)T/NT-7 036198* 7 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.68 (17.3) 305 (454) 390 (580)
TP16(IS-OS)T/NT-8 030166* 8 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.74 (18.8) 340 (506) 433 (644)
TP16(IS-OS)T/NT-9 036200* 9 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.1) 380 (565) 479 (713)
TP16(IS-OS)T/NT-10 036201* 10 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.86 (21.9) 420 (625) 528 (786)
TP16(IS-OS)T/NT-11 036202* 11 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.93 (23.6) 452 (673) 569 (847)
TP16(IS-OS)T/NT-12 036203* 12 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.93 (23.6) 517 (769) 634 (943)
TP16(IS-OS)T/NT-13 036204* 13 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 554 (824) 677 (1007)
TP16(IS-OS)T/NT-14 036205* 14 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 583 (868) 706 (1051)
TP16(IS-OS)T/NT-15 030161* 15 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 622 (926) 751 (1117)
TP16(IS-OS)T/NT-16 036207* 16 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 650 (967) 779 (1159)
TP16(IS-OS)T/NT-17 036208* 17 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 689 (1025) 824 (1226)
TP16(IS-OS)T/NT-18 036209* 18 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 718 (1068) 853 (1269)
TP16(IS-OS)T/NT-19 036210* 19 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 746 (1110) 881 (1311)
TP16(IS-OS)T/NT-20 030163* 20 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.12 (28.5) 786 (1170) 928 (1381)
TP16(IS-OS)T/NT-21 036212* 21 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.12 (28.5) 814 (1211) 956 (1423)
TP16(IS-OS)T/NT-22 036213* 22 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.17 (29.7) 853 (1269) 1002 (1491)
*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
18
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 18 AWG 0.82 mm2 / 600V
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_1
8AW
G_S
igna
l_20
16-1
1-28
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
19
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_1
8AW
G_S
igna
l_20
16-1
1-28
BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 18 AWG 0.82 mm2 / 600V
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
Jacket Thicknessin (mm)
Cable Diameter (nominal)in (mm)
Cable Weight (approximate)
Lbs/mft (Kg/km)
UNARMORED
TP18(OS)T/NT-1 029504 1 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.27 (6.8) 40 (59)
TP18(IS-OS)T/NT-2 030171 2 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.39 (10.0) 74 (111)
TP18(IS-OS)T/NT-3 029509 3 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.42 (10.6) 97 (145)
TP18(IS-OS)T/NT-4 030173 4 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.46 (11.6) 122 (181)
TP18(IS-OS)T/NT-5 029511 5 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.50 (12.7) 147 (218)
TP18(IS-OS)T/NT-6 036176 6 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.57 (14.6) 189 (282)
TP18(IS-OS)T/NT-7 029514 7 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.57 (14.6) 210 (313)
TP18(IS-OS)T/NT-8 030174 8 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.62 (15.7) 237 (352)
TP18(IS-OS)T/NT-9 036179 9 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.67 (16.9) 263 (392)
TP18(IS-OS)T/NT-10 029503 10 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.72 (18.4) 291 (433)
TP18(IS-OS)T/NT-11 036180 11 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.75 (19.0) 312 (465)
TP18(IS-OS)T/NT-12 030170 12 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.75 (19.0) 336 (500)
TP18(IS-OS)T/NT-13 036182 13 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.0) 361 (538)
TP18(IS-OS)T/NT-14 036183 14 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.0) 383 (570)
TP18(IS-OS)T/NT-15 036184 15 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.87 (22.1) 442 (659)
TP18(IS-OS)T/NT-16 036185 16 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.87 (22.1) 464 (690)
TP18(IS-OS)T/NT-17 036186 17 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 492 (732)
TP18(IS-OS)T/NT-18 036187 18 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 513 (763)
TP18(IS-OS)T/NT-19 036188 19 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 534 (795)
TP18(IS-OS)T/NT-20 029507 20 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.96 (24.5) 562 (837)
TP18(IS-OS)T/NT-21 036190 21 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.96 (24.5) 584 (868)
TP18(IS-OS)T/NT-22 036191 22 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.01 (25.7) 613 (912)
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
Jacket Thicknessin (mm)
Armored Cable Diameterin (mm)
Aluminum Armored Cable
WeightLbs/mft (Kg/km)
BronzeArmored Cable
WeightLbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
TP18(OS)T/NT-1 029504* 1 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.32 (8.2) 57 (85) 95 (141)
TP18(IS-OS)T/NT-2 030171* 2 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.44 (11.2) 97 (144) 152 (226)
TP18(IS-OS)T/NT-3 029509* 3 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.47 (12.0) 122 (182) 180 (268)
TP18(IS-OS)T/NT-4 030173* 4 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.40 (10.2) 149 (222) 213 (317)
TP18(IS-OS)T/NT-5 029511* 5 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.55 (14.0) 177 (263) 245 (365)
TP18(IS-OS)T/NT-6 036176* 6 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.62 (15.8) 223 (332) 300 (446)
TP18(IS-OS)T/NT-7 029514* 7 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.62 (15.8) 244 (363) 321 (478)
TP18(IS-OS)T/NT-8 030174* 8 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.67 (17.0) 273 (406) 257 (382)
TP18(IS-OS)T/NT-9 036179* 9 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.72 (18.3) 302 (449) 393 (585)
TP18(IS-OS)T/NT-10 029503* 10 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.77 (19.6) 333 (496) 430 (640)
TP18(IS-OS)T/NT-11 036180* 11 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.80 (20.3) 356 (530) 456 (679)
TP18(IS-OS)T/NT-12 030170* 12 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.80 (20.3) 380 (565) 480 (714)
TP18(IS-OS)T/NT-13 036182* 13 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.4) 407 (606) 513 (763)
TP18(IS-OS)T/NT-14 036183* 14 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.4) 429 (638) 535 (796)
TP18(IS-OS)T/NT-15 036184* 15 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.4) 492 (732) 608 (905)
TP18(IS-OS)T/NT-16 036185* 16 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.4) 514 (765) 630 (937)
TP18(IS-OS)T/NT-17 036186* 17 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 545 (811) 668 (994)
TP18(IS-OS)T/NT-18 036187* 18 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 566 (842) 689 (1025)
TP18(IS-OS)T/NT-19 036188* 19 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 587 (873) 710 (1056)
TP18(IS-OS)T/NT-20 029507* 20 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.01 (25.7) 617 (918) 745 (1109)
TP18(IS-OS)T/NT-21 036190* 21 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.01 (25.7) 639 (951) 767 (1141)
TP18(IS-OS)T/NT-22 036191* 22 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.06 (26.9) 671 (998) 806 (1199)
*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
20
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 20 AWG 0.52 mm2 / 300V
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_2
0AW
G_S
igna
l_20
16-1
1-28
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
21
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE T
/N_2
0AW
G_S
igna
l_20
16-1
1-28
BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 20 AWG 0.52 mm2 / 300V
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
Jacket Thicknessin (mm)
Cable Diameter (nominal)in (mm)
Cable Weight (approximate)
Lbs/mft (Kg/km)
UNARMORED
TP20(OS)T/NT-1 030190 1 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.25 (6.3) 33 (49)
TP20(IS-OS)T/NT-2 030193 2 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.36 (9.1) 61 (91)
TP20(IS-OS)T/NT-3 030194 3 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.38 (9.7) 80 (119)
TP20(IS-OS)T/NT-4 030195 4 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.41 (10.5) 99 (147)
TP20(IS-OS)T/NT-5 036154 5 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.45 (11.5) 118 (175)
TP20(IS-OS)T/NT-6 036155 6 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.49 (12.5) 137 (204)
TP20(IS-OS)T/NT-7 036156 7 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.49 (12.5) 153 (228)
TP20(IS-OS)T/NT-8 036157 8 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.56 (14.3) 186 (277)
TP20(IS-OS)T/NT-9 036158 9 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.61 (15.4) 211 (314)
TP20(IS-OS)T/NT-10 029501 10 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.66 (16.7) 229 (341)
TP20(IS-OS)T/NT-11 036159 11 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.68 (17.2) 245 (365)
TP20(IS-OS)T/NT-12 030191 12 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.68 (17.2) 267 (397)
TP20(IS-OS)T/NT-13 036161 13 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.71 (18.1) 287 (427)
TP20(IS-OS)T/NT-14 036162 14 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.71 (18.1) 303 (450)
TP20(IS-OS)T/NT-15 036163 15 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.75 (19.1) 323 (481)
TP20(IS-OS)T/NT-16 036164 16 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.75 (19.1) 339 (504)
TP20(IS-OS)T/NT-17 036165 17 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.2) 360 (535)
TP20(IS-OS)T/NT-18 036166 18 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.2) 375 (559)
TP20(IS-OS)T/NT-19 036167 19 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.2) 391 (582)
TP20(IS-OS)T/NT-20 036168 20 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.88 (22.2) 447 (665)
TP20(IS-OS)T/NT-21 036169 21 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.88 (22.2) 463 (689)
TP20(IS-OS)T/NT-22 036170 22 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.92 (23.3) 485 (722)
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
PVC/NylonInsulation Thickness
in (mm)
Jacket Thicknessin (mm)
Armored Cable Diameterin (mm)
Aluminum Armored Cable
WeightLbs/mft (Kg/km)
BronzeArmored Cable
WeightLbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
TP20(OS)T/NT-1 030190* 1 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.30 (7.6) 49 (73) 86 (128)
TP20(IS-OS)T/NT-2 030193* 2 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.41 (10.4) 83 (135) 135 (201)
TP20(IS-OS)T/NT-3 030194* 3 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.43 (10.9) 103 (153) 158 (235)
TP20(IS-OS)T/NT-4 030195* 4 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.46 (11.7) 124 (185) 182 (271)
TP20(IS-OS)T/NT-5 036154* 5 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.50 (12.7) 145 (216) 209 (311)
TP20(IS-OS)T/NT-6 036155* 6 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.54 (13.7) 167 (248) 236 (351)
TP20(IS-OS)T/NT-7 036156* 7 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.54 (13.7) 183 (272) 252 (375)
TP20(IS-OS)T/NT-8 036157* 8 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.61 (15.5) 220 (327) 298 (443)
TP20(IS-OS)T/NT-9 036158* 9 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.66 (15.4) 248 (369) 332 (494)
TP20(IS-OS)T/NT-10 029501* 10 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.71 (18.0) 269 (400) 360 (536)
TP20(IS-OS)T/NT-11 036159* 11 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.73 (18.5) 286 (426) 380 (565)
TP20(IS-OS)T/NT-12 030191* 12 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.73 (18.5) 308 (458) 402 (598)
TP20(IS-OS)T/NT-13 036161* 13 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.76 (19.3) 329 (490) 427 (635)
TP20(IS-OS)T/NT-14 036162* 14 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.76 (19.3) 345 (513) 443 (695)
TP20(IS-OS)T/NT-15 036163* 15 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.80 (20.3) 368 (548) 471 (701)
TP20(IS-OS)T/NT-16 036164* 16 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.80 (20.3) 384 (571) 487 (725)
TP20(IS-OS)T/NT-17 036165* 17 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.3) 407 (606) 515 (766)
TP20(IS-OS)T/NT-18 036166* 18 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.3) 422 (628) 530 (789)
TP20(IS-OS)T/NT-19 036167* 19 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.3) 438 (652) 546 (812)
TP20(IS-OS)T/NT-20 036168* 20 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.93 (23.6) 499 (743) 620 (923)
TP20(IS-OS)T/NT-21 036169* 21 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.93 (23.6) 515 (766) 636 (946)
TP20(IS-OS)T/NT-22 036170* 22 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (23.3) 539 (802) 665 (990)
22
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type X Control CableMulti-Conductor / Unarmored & Armored / 18, 16, and 14 AWG / 600V
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
A70
0_B
OST
MA
RIN
E_TY
PE X
_Con
trol
Cab
le_2
016-
11-2
8
Lloyd’sRegister
23
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A70
0_B
OST
MA
RIN
E_TY
PE X
_Con
trol
Cab
le_2
016-
11-1
7
A brand of the
BOSTMARINE Type X Control CableMulti-Conductor / Unarmored & Armored / 18, 16, and 14 AWG / 600V
TPC Cable Type
Part Number*Number of Conductors
Stranding Type
Insulation Thickness
in (mm)
JacketThickness
in (mm)
CableDiameter
(nom)in (mm)
Cable Weight (approx)Lbs/mft(Kg/km)
Armored Cable Diameter
(nom)Lbs/mft(Kg/km)
Aluminum Arm. Cable
Weight Lbs/mft(Kg/km)
Bronze Arm. Cable Weight
Lbs/mft(Kg/km)
18 AWG • 1.0 mm2
C18XT-2 036570* 2 7/15.2 .030 (0.76) .045 (1.14) 0.32 (8.0) 47 (70) 0.375 (9.5) 67 (100) 113 (168)
C18XT-3 036571* 3 7/15.2 .030 (0.76) .045 (1.14) 0.33 (8.4) 56 (83) 0.385 (9.8) 77 (115) 124 (185)
C18XT-4 036572* 4 7/15.2 .030 (0.76) .045 (1.14) 0.36 (9.1) 68 (101) 0.415 (10.5) 90 (134) 142 (211)
C18XT-7 036573* 7 7/15.2 .030 (0.76) .045 (1.14) 0.42 (10.8) 99 (147) 0.475 (12.1) 125 (186) 184 (274)
C18XT-10 036574* 10 7/15.2 .030 (0.76) .060 (1.52) 0.56 (14.4) 153 (228) 0.615 (15.6) 187 (278) 265 (394)
C18XT-16 036575* 16 7/15.2 .030 (0.76) .060 (1.52) 0.61 (15.5) 195 (290) 0.665 (16.9) 232 (345) 316 (470)
C18XT-20 036576* 20 7/15.2 .030 (0.76) .060 (1.52) 0.67 (17.0) 250 (372) 0.725 (18.4) 290 (432) 383 (570)
C18XT-24 036577* 24 7/15.2 .030 (0.76) .060 (1.52) 0.78 (19.8) 308 (458) 0.835 (21.2) 354 (527) 462 (687)
C18XT-30 036578* 30 7/15.2 .030 (0.76) .080 (2.03) 0.88 (22.4) 370 (551) 0.915 (23.2) 422 (628) 543 (808)
C18XT-37 036579* 37 7/15.2 .030 (0.76) .080 (2.03) 0.93 (23.6) 480 (714) 0.985 (25.0) 535 (796) 662 (985)
C18XT-44 036580* 44 7/15.2 .030 (0.76) .080 (2.03) 1.03 (26.2) 547 (814) 1.085 (27.6) 608 (905) 748 (1113)
C18XT-61 036581* 61 7/15.2 .030 (0.76) .080 (2.03) 1.10 (27.9) 696 (1036) 1.155 (29.3) 761 (1132) 910 (1354)
16 AWG • 1.3 mm2
C16XT-2 036582* 2 7/19.2 .030 (0.76) .045 (1.14) 0.34 (8.6) 57 (85) 0.395 (10.0) 78 (116) 127 (189)
C16XT-3 036583* 3 7/19.2 .030 (0.76) .045 (1.14) 0.36 (9.1) 71 (106) 0.415 (10.5) 93 (138) 145 (216)
C16XT-4 036584* 4 7/19.2 .030 (0.76) .045 (1.14) 0.39 (9.9) 87 (129) 0.445 (11.3) 111 (165) 167 (248)
C16XT-7 036585* 7 7/19.2 .030 (0.76) .045 (1.14) 0.46 (11.7) 129 (192) 0.515 (13.1) 157 (234) 222 (330)
C16XT-10 036053* 10 7/19.2 .030 (0.76) .060 (1.52) 0.61 (15.6) 197 (293) 0.665 (16.9) 234 (348) 318 (473)
C16XT-16 036586* 16 7/19.2 .030 (0.76) .060 (1.52) 0.67 (16.9) 255 (379) 0.725 (18.4) 295 (439) 388 (577)
C16XT-20 036587* 20 7/19.2 .030 (0.76) .060 (1.52) 0.73 (18.7) 328 (488) 0.785 (19.9) 372 (553) 472 (702)
C16XT-24 036588* 24 7/19.2 .030 (0.76) .080 (2.03) 0.90 (22.9) 444 (661) 0.955 (24.3) 497 (740) 620 (923)
C16XT-30 036589* 30 7/19.2 .030 (0.76) .080 (2.03) 0.95 (24.1) 529 (787) 1.005 (25.5) 585 (870) 715 (1064)
C16XT-37 036590* 37 7/19.2 .030 (0.76) .080 (2.03) 1.02 (25.9) 631 (939) 1.075 (27.3) 691 (1028) 830 (1235)
C16XT-44 036591* 44 7/19.2 .030 (0.76) .080 (2.03) 1.16 (29.3) 748 (1113) 1.215 (30.9) 816 (1214) 974 (1449)
C16XT-61 036592* 61 7/19.2 .030 (0.76) .080 (2.03) 1.27 (32.4) 980 (1458) 1.325 (33.7) 1054 (1568) 1227 (1825)
14 AWG • 2.1 mm2
C14XT-2 036593* 2 7/24.2 .030 (0.76) .045 (1.14) 0.37 (9.4) 72 (107) 0.425 (10.8) 95 (141) 148 (220)
C14XT-3 036594* 3 7/24.2 .030 (0.76) .045 (1.14) 0.39 (9.9) 92 (137) 0.445 (11.3) 116 (173) 172 (256)
C14XT-4 036595* 4 7/24.2 .030 (0.76) .045 (1.14) 0.42 (10.8) 114 (170) 0.475 (12.1) 140 (208) 199 (296)
C14XT-7 036057* 7 7/24.2 .030 (0.76) .045 (1.14) 0.51 (12.8) 173 (257) 0.565 (14.4) 204 (306) 275 (409)
C14XT-10 036596* 10 7/24.2 .030 (0.76) .060 (1.52) 0.68 (17.1) 261 (388) 0.735 (18.7) 302 (449) 396 (589)
C14XT-16 036058* 16 7/24.2 .030 (0.76) .060 (1.52) 0.73 (18.5) 342 (509) 0.785 (19.9) 386 (574) 486 (723)
C14XT-20 036597* 20 7/24.2 .030 (0.76) .060 (1.52) 0.81 (20.6) 444 (661) 0.865 (22.0) 492 (732) 603 (897)
C14XT-24 036059* 24 7/24.2 .030 (0.76) .080 (2.03) 0.99 (25.1) 593 (882) 1.045 (26.5) 651 (969) 786 (1170)
C14XT-30 036598* 30 7/24.2 .030 (0.76) .080 (2.03) 1.05 (26.7) 714 (1063) 1.105 (28.1) 776 (1155) 919 (1367)
C14XT-37 036599* 37 7/24.2 .030 (0.76) .080 (2.03) 1.13 (28.7) 856 (1274) 1.185 (30.1) 922 (1372) 1076 (1601)
C14XT-44 036600* 44 7/24.2 .030 (0.76) .080 (2.03) 1.27 (32.3) 1010 (1503) 1.325 (33.7) 1084 (1613) 1257 (1870)
C14XT-61 036601* 61 7/24.2 .030 (0.76) .080 (2.03) 1.40 (35.4) 1350 (2009) 1.455 (37.0) 1432 (2131) 1621 (2412)
*NOTE: For aluminum armored versions, add an A (ex. 036570A). For bronze armored versions, add a B (ex. 036570B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
24
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type X Power CableTwo Conductor / Unarmored & Armored / 14 AWG to 1000 MCM / 600V
A70
0_B
OST
MA
RIN
E_TY
PE X
_2C_
Pow
er_2
016-
11-2
1
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
25
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)Stranding Type
Insulation Thicknessin (mm)
JacketThickness
in (mm)
Cable Diameter(nominal)in (mm)
Cable Weight(approximate)
Lbs/mft (Kg/km)
UNARMORED
DXT-4 036012 14 (2.1) 7/24.2 0.030 (0.76) 0.045 (1.14) 0.380 (9.7) 81 (121)
DXT-6 036013 12 (3.3) 7/30.5 0.030 (0.76) 0.045 (1.14) 0.420 (10.7) 98 (146)
DXT-10 036050 10 (5.3) 7/38.5 0.030 (0.76) 0.045 (1.14) 0.470 (11.9) 138 (205)
DXT-16 036051 8 (8.4) 7/48.6 0.045 (1.14) 0.060 (1.52) 0.630 (16.0) 234 (348)
DXT-26 036542 6 (13.3) 7/61.2 0.045 (1.14) 0.060 (1.52) 0.705 (17.9) 280 (417)
DXT-41 036543 4 (21.1) 7/77.2 0.045 (1.14) 0.060 (1.52) 0.810 (20.6) 448 (667)
DXT-66 036544 2 (33.6) 7/97.4 0.045 (1.14) 0.080 (2.03) 0.970 (24.6) 682 (1015)
DXT-83 036545 1 (42.4) 19/66.4 0.055 (1.40) 0.080 (2.03) 1.090 (27.7) 835 (1242)
DXT-106 036546 1/0 (53.5) 19/74.5 0.055 (1.40) 0.080 (2.03) 1.180 (30.0) 915 (1362)
DXT-133 036547 2/0 (67.4) 19/83.7 0.055 (1.40) 0.080 (2.03) 1.270 (32.3) 1222 (1818)
DXT-168 036548 3/0 (85.0) 19/94.0 0.055 (1.40) 0.080 (2.03) 1.380 (35.1) 1491 (2219)
DXT-212 036549 4/0 (107.2) 19/105.5 0.055 (1.40) 0.080 (2.03) 1.490 (37.8) 1805 (2686)
DXT-250 036550 250 (127.0) 37/82.2 0.065 (1.65) 0.080 (2.03) 1.630 (41.4) 1945 (2894)
DXT-300 036551 300 (152.0) 37/90.0 0.065 (1.65) 0.110 (2.79) 1.810 (46.0) 2385 (3549)
DXT-350 036552 350 (177.0) 37/97.3 0.065 (1.65) 0.110 (2.79) 1.910 (48.5) 2735 (4070)
DXT-400 036553 400 (203.0) 37/104.0 0.065 (1.65) 0.110 (2.79) 2.005 (50.9) 3080 (4584)
DXT-500 036554 500 (253.0) 37/116.2 0.065 (1.65) 0.110 (2.79) 2.180 (55.4) 3755 (5588)
DXT-600 036555 600 (304.0) 61/99.2 0.080 (2.03) 0.110 (2.79) 2.405 (61.1) 4530 (6741)
DXT-750 036556 750 (380.0) 61/110.9 0.080 (2.03) 0.110 (2.79) 2.620 (66.5) 5550 (8259)
DXT-1000 036557 1000 (507.0) 61/128.0 0.080 (2.03) 0.110 (2.79) 2.995 (76.1) 7390 (10,997)
*NOTE: For aluminum armored versions, add an A (ex. 3036012A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)Stranding Type
Insulation Thickness
in (mm)
JacketThickness
in (mm)
Armored CableDiameterin (mm)
Aluminum Armor Cable Weight
Lbs/mft (Kg/km)
Bronze ArmorCable Weight
Lbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
DXT-4 036012* 14 (2.1) 7/24.2 0.030 (0.76) 0.045 (1.14) 0.435 (11.0) 104 (155) 159 (237)
DXT-6 036013* 12 (3.3) 7/30.5 0.030 (0.76) 0.045 (1.14) 0.475 (12.1) 124 (185) 183 (272)
DXT-10 036050* 10 (5.3) 7/38.5 0.030 (0.76) 0.045 (1.14) 0.525 (13.3) 167 (248) 233 (347)
DXT-16 036051* 8 (8.4) 7/48.6 0.045 (1.14) 0.060 (1.52) 0.685 (17.4) 272 (405) 359 (534)
DXT-26 036542* 6 (13.3) 7/61.2 0.045 (1.14) 0.060 (1.52) 0.760 (19.3) 322 (479) 419 (623)
DXT-41 036543* 4 (21.1) 7/77.2 0.045 (1.14) 0.060 (1.52) 0.865 (22.0) 496 (738) 607 (903)
DXT-66 036544* 2 (33.6) 7/97.4 0.045 (1.14) 0.080 (2.03) 1.025 (26.0) 739 (1100) 872 (1298)
DXT-83 036545* 1 (42.4) 19/66.4 0.055 (1.40) 0.080 (2.03) 1.145 (29.1) 899 (1338) 1047 (1558)
DXT-106 036546* 1/0 (53.5) 19/74.5 0.055 (1.40) 0.080 (2.03) 1.235 (31.4) 984 (1464) 1145 (1704)
DXT-133 036547* 2/0 (67.4) 19/83.7 0.055 (1.40) 0.080 (2.03) 1.325 (33.7) 1296 (1928) 1469 (2632)
DXT-168 036548* 3/0 (85.0) 19/94.0 0.055 (1.40) 0.080 (2.03) 1.435 (36.4) 1572 (2339) 1758 (2616)
DXT-212 036549* 4/0 (107.2) 19/105.5 0.055 (1.40) 0.080 (2.03) 1.545 (39.2) 1892 (2815) 2093 (3114)
DXT-250 036550* 250 (127.0) 37/82.2 0.065 (1.65) 0.080 (2.03) 1.685 (42.3) 2040 (3036) 2260 (3363)
DXT-300 036551* 300 (152.0) 37/90.0 0.065 (1.65) 0.110 (2.79) 1.865 (47.4) 2490 (3705) 2734 (4068)
DXT-350 036552* 350 (177.0) 37/97.3 0.065 (1.65) 0.110 (2.79) 1.965 (49.9) 2846 (4235) 3103 (4617)
DXT-400 036553* 400 (203.0) 37/104.0 0.065 (1.65) 0.110 (2.79) 2.060 (52.3) 3197 (4757) 3466 (5157)
DXT-500 036554* 500 (253.0) 37/116.2 0.065 (1.65) 0.110 (2.79) 2.235 (56.8) 3882 (5776) 4174 (6211)
DXT-600 036555* 600 (304.0) 61/99.2 0.080 (2.03) 0.110 (2.79) 2.460 (62.5) 4670 (6949) 4991 (7427)
DXT-750 036556* 750 (380.0) 61/110.9 0.080 (2.03) 0.110 (2.79) 2.675 (67.9) 5702 (8485) 6053 (9007)
DXT-1000 036557* 1000 (507.0) 61/128.0 0.080 (2.03) 0.140 (3.56) 3.055 (77.6) 7563 (11,254) 7964 (11,850)
A70
0_B
OST
MA
RIN
E_TY
PE X
_2C_
Pow
er_2
016-
11-2
1
A brand of the
BOSTMARINE Type X Power CableTwo Conductor/ Unarmored & Armored / 14 AWG to 1000 MCM / 600V
26
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type X Power CableThree Conductor / Unarmored & Armored / 14 AWG to 1000 MCM / 600V
A70
0_B
OST
MA
RIN
E_TY
PE X
_3C_
Pow
er_2
016-
11-3
0
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
27
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A70
0_B
OST
MA
RIN
E_TY
PE X
_3C_
Pow
er_2
016-
11-3
0
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)Stranding Type
Insulation Thicknessin (mm)
JacketThickness
in (mm)
Cable Diameter(nominal)in (mm)
Cable Weight(approximate)
Lbs/mft (Kg/km)
UNARMORED
TXT-4 030125 14 • 2.1 7/24.2 0.030 (0.76) 0.045 (1.14) 0.400 (10.2) 90 (134)
TXT-6 030113 12 • 3.3 7/30.5 0.030 (0.76) 0.045 (1.14) 0.440 (11.2) 120 (179)
TXT-10 036010 10 • 5.3 7/38.5 0.030 (0.76) 0.045 (1.14) 0.500 (12.7) 170 (253)
TXT-16 036009 8 • 8.4 7/48.6 0.045 (1.14) 0.060 (1.52) 0.670 (17.1) 280 (417)
TXT-26 036055 6 • 13.3 7/61.2 0.045 (1.14) 0.060 (1.52) 0.750 (19.1) 395 (588)
TXT-41 036008 4 • 21.1 7/77.2 0.045 (1.14) 0.080 (2.03) 0.900 (23.0) 570 (848)
TXT-66 036007 2 • 33.6 7/97.4 0.045 (1.14) 0.080 (2.03) 1.030 (26.2) 875 (1302)
TXT-83 030126 1 • 42.4 19/66.4 0.055 (1.40) 0.080 (2.03) 1.160 (29.5) 1090 (1622)
TXT-106 030127 1/0 • 53.5 19/74.5 0.055 (1.40) 0.080 (2.03) 1.255 (31.9) 1320 (1964)
TXT-133 030140 2/0 • 67.4 19/83.7 0.055 (1.40) 0.080 (2.03) 1.355 (34.4) 1615 (2403)
TXT-168 030141 3/0 • 85.0 19/94.0 0.055 (1.40) 0.080 (2.03) 1.470 (37.3) 1980 (2947)
TXT-212 030142 4/0 • 107.2 19/105.5 0.055 (1.40) 0.080 (2.03) 1.595 (40.5) 2435 (3624)
TXT-250 030158 250 • 127.0 37/82.2 0.065 (1.65) 0.110 (2.79) 1.810 (46.0) 2965 (4412)
TXT-300 036559 300 • 152.0 37/90.0 0.065 (1.65) 0.110 (2.79) 1.930 (49.0) 3485 (5186)
TXT-350 030124 350 • 177.0 37/97.3 0.065 (1.65) 0.110 (2.79) 2.040 (51.8) 4005 (5960)
TXT-400 030200 400 • 203.0 37/104.0 0.065 (1.65) 0.110 (2.79) 2.140 (54.4) 4525 (6734)
TXT-500 030647 500 • 253.0 37/116.2 0.065 (1.65) 0.110 (2.79) 2.330 (59.2) 5545 (8252)
TXT-750 036561 750 • 380.0 61/110.9 0.080 (2.03) 0.140 (3.56) 2.865 (72.8) 8420 (12,530)
TXT-1000 036562 1000 • 507.0 61/128.0 0.080 (2.03) 0.140 (3.56) 3.200 (81.3) 11,000 (16,370)
*NOTE: For aluminum armored versions, add an A (ex. 3036012A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)Stranding Type
Insulation Thickness
in (mm)
JacketThickness
in (mm)
Armored CableDiameterin (mm)
Aluminum Armor Cable Weight
Lbs/mft (Kg/km)
Bronze ArmorCable Weight
Lbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
TXT-4 030125* 14 • 2.1 7/24.2 0.030 (0.76) 0.045 (1.14) 0.440 (11.2) 115 (171) 171 (254)
TXT-6 030113* 12 • 3.3 7/30.5 0.030 (0.76) 0.045 (1.14) 0.490 (12.5) 147 (219) 209 (311)
TXT-10 036010* 10 • 5.3 7/38.5 0.030 (0.76) 0.045 (1.14) 0.550 (14.0) 200 (298) 270 (402)
TXT-16 036009* 8 • 8.4 7/48.6 0.045 (1.14) 0.060 (1.52) 0.720 (18.3) 320 (476) 413 (615)
TXT-26 036055* 6 • 13.3 7/61.2 0.045 (1.14) 0.060 (1.52) 0.880 (22.4) 440 (655) 543 (808)
TXT-41 036008* 4 • 21.1 7/77.2 0.045 (1.14) 0.080 (2.03) 0.950 (24.2) 623 (927) 746 (1110)
TXT-66 036007* 2 • 33.6 7/97.4 0.045 (1.14) 0.080 (2.03) 1.080 (27.6) 936 (1393) 1076 (1601)
TXT-83 030126* 1 • 42.4 19/66.4 0.055 (1.40) 0.080 (2.03) 1.210 (30.8) 1158 (1732) 1316 (1958)
TXT-106 030127* 1/0 • 53.5 19/74.5 0.055 (1.40) 0.080 (2.03) 1.310 (33.3) 1394 (2074) 1564 (2327)
TXT-133 030140* 2/0 • 67.4 19/83.7 0.055 (1.40) 0.080 (2.03) 1.410 (35.8) 1694 (2521) 1878 (2794)
TXT-168 030141* 3/0 • 85.0 19/94.0 0.055 (1.40) 0.080 (2.03) 1.520 (38.6) 2066 (3074) 2265 (3370)
TXT-212 030142* 4/0 • 107.2 19/105.5 0.055 (1.40) 0.080 (2.03) 1.650 (41.9) 2528 (3762) 2743 (4082)
TXT-250 030158* 250 • 127.0 37/82.2 0.065 (1.65) 0.110 (2.79) 1.860 (47.3) 3070 (4568) 3314 (4931)
TXT-300 036559* 300 • 152.0 37/90.0 0.065 (1.65) 0.110 (2.79) 1.980 (50.3) 3597 (5352) 3857 (5739)
TXT-350 030124* 350 • 177.0 37/97.3 0.065 (1.65) 0.110 (2.79) 2.090 (53.1) 4124 (6137) 4398 (6544)
TXT-400 030200* 400 • 203.0 37/104.0 0.065 (1.65) 0.110 (2.79) 2.190 (55.7) 4649 (6918) 4937 (7346)
TXT-500 030647* 500 • 253.0 37/116.2 0.065 (1.65) 0.110 (2.79) 2.380 (60.5) 5680 (8452) 5993 (8918)
TXT-750 036561* 750 • 380.0 61/110.9 0.080 (2.03) 0.140 (3.56) 2.920 (74.2) 8586 (12,776) 8969 (13,346)
TXT-1000 036562* 1000 • 507.0 61/128.0 0.080 (2.03) 0.140 (3.56) 3.250 (82.6) 11,185 (16,643) 11,613 (17,280)
A brand of the
BOSTMARINE Type X Power CableThree Conductor/ Unarmored & Armored / 14 AWG to 1000 MCM / 600V
28
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type X Power CableFour Conductor / Unarmored & Armored / 14 AWG to 500 MCM / 600V
A70
0_B
OST
MA
RIN
E_TY
PE X
_4C_
Pow
er_2
016-
11-1
7
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
29
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE X
_4C_
Pow
er_2
016-
11-1
7
BOSTMARINE Type X Power CableFour Conductor/ Unarmored & Armored / 14 AWG to 500 MCM / 600V
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)Stranding Type
Insulation Thicknessin (mm)
JacketThickness
in (mm)
Cable Diameter(nominal)in (mm)
Cable Weight(approximate)
Lbs/mft (Kg/km)
UNARMORED
FXT-4 036563 14 (2.1) 7/24.2 .030 (0.76) .045 (1.14) 0.440 (11.2) 120 (179)
FXT-6 036564 12 (3.3) 7/30.5 .030 (0.76) .045 (1.14) 0.485 (12.3) 164 (244)
FXT-10 036052 10 (5.3) 7/38.5 .030 (0.76) .060 (1.52) 0.575 (14.6) 241 (359)
FXT-16 036565 8 (8.4) 7/48.6 .045 (1.14) .060 (1.52) 0.730 (18.5) 382 (568)
FXT-26 036566 6 (13.3) 7/61.2 .045 (1.14) .060 (1.52) 0.830 (21.1) 542 (806)
FXT-41 036015 4 (21.1) 7/77.2 .045 (1.14) .080 (2.03) 0.990 (25.1) 824 (1226)
FXT-66 036011 2 (33.6) 7/97.4 .045 (1.14) .080 (2.03) 1.140 (29.0) 1205 (1793)
FXT-83 030143 1 (42.4) 19/66.4 .055 (1.40) .080 (2.03) 1.290 (32.8) 1500 (2232)
FXT-106 030144 1/0 (53.5) 19/74.5 .055 (1.40) .080 (2.03) 1.390 (35.3) 1782 (2652)
FXT-133 030145 2/0 (67.4) 19/83.7 .055 (1.40) .080 (2.03) 1.500 (38.1) 2220 (3303)
FXT-168 030146 3/0 (85.0) 19/94.0 .055 (1.40) .080 (2.03) 1.625 (41.3) 2706 (4027)
FXT-212 030147 4/0 (107.2) 19/105.5 .055 (1.40) .110 (2.79) 1.830 (46.5) 3444 (5125)
FXT-250 030183 250 (127.0) 37/82.2 .065 (1.65) .110 (2.79) 2.000 (50.8) 4002 (5955)
FXT-300 036568 300 (152.0) 37/90.0 .065 (1.65) .110 (2.79) 2.130 (54.1) 4680 (6964)
FXT-350 030389 350 (177.0) 37/97.3 .065 (1.65) .110 (2.79) 2.260 (57.4) 5464 (8130)
FXT-400 036569 400 (203.0) 37104.0 .065 (1.65) .110 (2.79) 2.370 (60.2) 6140 (9136)
FXT-500 030647 500 (253.0) 37/116.2 .065 (1.65) .110 (2.79) 2.580 (65.5) 7560 (11,250)
*NOTE: For aluminum armored versions, add an A (ex. 3036563A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
TPC Cable TypePart
Number
Conductor Size AWG/MCM
(mm2)Stranding Type
Insulation Thickness
in (mm)
JacketThickness
in (mm)
Armored CableDiameterin (mm)
Aluminum Armor Cable Weight
Lbs/mft (Kg/km)
Bronze ArmorCable Weight
Lbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
FXT-4 036563* 14 (2.1) 7/24.2 .030 (0.76) .045 (1.14) 0.495 (12.6) 147 (219) 209 (311)
FXT-6 036564* 12 (3.3) 7/30.5 .030 (0.76) .045 (1.14) 0.540 (13.7) 193 (287) 262 (390)
FXT-10 036052* 10 (5.3) 7/38.5 .030 (0.76) .060 (1.52) 0.630 (16.0) 276 (411) 356 (530)
FXT-16 036565* 8 (8.4) 7/48.6 .045 (1.14) .060 (1.52) 0.785 (19.9) 426 (634) 526 (783)
FXT-26 036566* 6 (13.3) 7/61.2 .045 (1.14) .060 (1.52) 0.885 (22.5) 591 (879) 705 (1049)
FXT-41 036015* 4 (21.1) 7/77.2 .045 (1.14) .080 (2.03) 1.045 (26.5) 882 (1312) 1017 (1513)
FXT-66 036011* 2 (33.6) 7/97.4 .045 (1.14) .080 (2.03) 1.195 (30.4) 1272 (1893) 1427 (2123)
FXT-83 030143* 1 (42.4) 19/66.4 .055 (1.40) .080 (2.03) 1.345 (34.2) 1576 (2345) 1750 (2604)
FXT-106 030144* 1/0 (53.5) 19/74.5 .055 (1.40) .080 (2.03) 1.445 (36.7) 1863 (2772) 2051 (3052)
FXT-133 030145* 2/0 (67.4) 19/83.7 .055 (1.40) .080 (2.03) 1.555 (39.5) 2308 (3434) 2510 (3735)
FXT-168 030146* 3/0 (85.0) 19/94.0 .055 (1.40) .080 (2.03) 1.680 (42.7) 2801 (4168) 3020 (4494)
FXT-212 030147* 4/0 (107.2) 19/105.5 .055 (1.40) .110 (2.79) 1.885 (47.9) 3551 (5284) 3797 (5650)
FXT-250 030183* 250 (127.0) 37/82.2 .065 (1.65) .110 (2.79) 2.055 (52.2) 4118 (6128) 4387 (6528)
FXT-300 036568* 300 (152.0) 37/90.0 .065 (1.65) .110 (2.79) 2.185 (55.5) 4804 (6128) 5090 (7574)
FXT-350 030389* 350 (177.0) 37/97.3 .065 (1.65) .110 (2.79) 2.315 (58.8) 5595 (8325) 5899 (8778)
FXT-400 036569* 400 (203.0) 37104.0 .065 (1.65) .110 (2.79) 2.425 (61.6) 6278 (9342) 6595 (9813)
FXT-500 030647* 500 (253.0) 37/116.2 .065 (1.65) .110 (2.79) 2.635 (66.9) 7710 (11,472) 8055 (11,986)
30
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 16 AWG 1.31 mm2 / 600V
A70
0_B
OST
MA
RIN
E_TY
PE X
_16A
WG
_Sig
nal_
2016
-11-
28
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
31
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE X
_16A
WG
_Sig
nal_
2016
-11-
28
BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 16 AWG 1.31 mm2 / 600V
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
Insulation Thicknessin (mm)
Jacket Thicknessin (mm)
Cable Diameter (nominal)in (mm)
Cable Weight (approximate)
Lbs/mft (Kg/km)
UNARMORED
TP16(IS)XT-1 036646 1 7/19.2 0.025 (0.64) 0.045 (1.14) 0.32 (8.1) 56 (83)
TP16(IS-OS)XT-2 036647 2 7/19.2 0.025 (0.64) 0.045 (1.14) 0.50 (12.7) 104 (155)
TP16(IS-OS)XT-3 036648 3 7/19.2 0.025 (0.64) 0.060 (1.52) 0.56 (14.2) 153 (228)
TP16(IS-OS)XT-4 036649 4 7/19.2 0.025 (0.64) 0.060 (1.52) 0.61 (15.5) 190 (283)
TP16(IS-OS)XT-5 036650 5 7/19.2 0.025 (0.64) 0.060 (1.52) 0.67 (17.0) 227 (338)
TP16(IS-OS)XT-6 036651 6 7/19.2 0.025 (0.64) 0.060 (1.52) 0.73 (18.5) 265 (394)
TP16(IS-OS)XT-7 036652 7 7/19.2 0.025 (0.64) 0.060 (1.52) 0.73 (18.5) 295 (439)
TP16(IS-OS)XT-8 036653 8 7/19.2 0.025 (0.64) 0.060 (1.52) 0.79 (20.1) 332 (494)
TP16(IS-OS)XT-9 036654 9 7/19.2 0.025 (0.64) 0.080 (2.03) 0.89 (22.6) 370 (551)
TP16(IS-OS)XT-10 036655 10 7/19.2 0.025 (0.64) 0.080 (2.03) 0.97 (24.6) 449 (668)
TP16(IS-OS)XT-11 036656 11 7/19.2 0.025 (0.64) 0.080 (2.03) 0.99 (25.1) 487 (724)
TP16(IS-OS)XT-12 036657 12 7/19.2 0.025 (0.64) 0.080 (2.03) 0.99 (25.1) 516 (768)
TP16(IS-OS)XT-13 036658 13 7/19.2 0.025 (0.64) 0.080 (2.03) 1.04 (26.4) 555 (826)
TP16(IS-OS)XT-14 036659 14 7/19.2 0.025 (0.64) 0.080 (2.03) 1.04 (26.4) 585 (870)
TP16(IS-OS)XT-15 036660 15 7/19.2 0.025 (0.64) 0.080 (2.03) 1.10 (27.9) 621 (924)
TP16(IS-OS)XT-16 036661 16 7/19.2 0.025 (0.64) 0.080 (2.03) 1.10 (27.9) 654 (974)
TP16(IS-OS)XT-17 036662 17 7/19.2 0.025 (0.64) 0.080 (2.03) 1.15 (29.2) 694 (1033)
TP16(IS-OS)XT-18 036663 18 7/19.2 0.025 (0.64) 0.080 (2.03) 1.15 (29.2) 724 (1078)
TP16(IS-OS)XT-19 036664 19 7/19.2 0.025 (0.64) 0.080 (2.03) 1.15 (29.2) 754 (1122)
TP16(IS-OS)XT-20 036665 20 7/19.2 0.025 (0.64) 0.080 (2.03) 1.21 (30.7) 790 (1176)
TP16(IS-OS)XT-21 036666 21 7/19.2 0.025 (0.64) 0.080 (2.03) 1.21 (30.7) 824 (1226)
TP16(IS-OS)XT-22 036667 22 7/19.2 0.025 (0.64) 0.080 (2.03) 1.28 (32.5) 865 (1287)
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
Insulation Thicknessin (mm)
Jacket Thicknessin (mm)
Armored Cable Diameterin (mm)
Aluminum Armored Cable
WeightLbs/mft (Kg/km)
BronzeArmored Cable
WeightLbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
TP16(IS)XT-1 036646* 1 7/19.2 0.025 (0.64) 0.045 (1.14) 0.375 (9.5) 76 (113) 122 (182)
TP16(IS-OS)XT-2 036647* 2 7/19.2 0.025 (0.64) 0.045 (1.14) 0.555 (14.1) 134 (199) 204 (304)
TP16(IS-OS)XT-3 036648* 3 7/19.2 0.025 (0.64) 0.060 (1.52) 0.615 (15.6) 187 (278) 265 (394)
TP16(IS-OS)XT-4 036649 4 7/19.2 0.025 (0.64) 0.060 (1.52) 0.665 (16.9) 227 (338) 311 (463)
TP16(IS-OS)XT-5 036650* 5 7/19.2 0.025 (0.64) 0.060 (1.52) 0.725 (18.4) 267 (397) 360 (534)
TP16(IS-OS)XT-6 036651* 6 7/19.2 0.025 (0.64) 0.060 (1.52) 0.785 (19.9) 309 (460) 409 (609)
TP16(IS-OS)XT-7 036652* 7 7/19.2 0.025 (0.64) 0.060 (1.52) 0.785 (19.9) 368 (548) 439 (653)
TP16(IS-OS)XT-8 036653* 8 7/19.2 0.025 (0.64) 0.060 (1.52) 0.845 (21.4) 379 (564) 487 (725)
TP16(IS-OS)XT-9 036654* 9 7/19.2 0.025 (0.64) 0.080 (2.03) 0.945 (24.0) 423 (629) 544 (809)
TP16(IS-OS)XT-10 036655* 10 7/19.2 0.025 (0.64) 0.080 (2.03) 1.025 (26.0) 506 (753) 639 (951)
TP16(IS-OS)XT-11 036656* 11 7/19.2 0.025 (0.64) 0.080 (2.03) 1.045 (26.5) 545 (811) 680 (1012)
TP16(IS-OS)XT-12 036657* 12 7/19.2 0.025 (0.64) 0.080 (2.03) 1.045 (26.5) 574 (854) 709 (1055)
TP16(IS-OS)XT-13 036658* 13 7/19.2 0.025 (0.64) 0.080 (2.03) 1.095 (27.8) 616 (917) 758 (1128)
TP16(IS-OS)XT-14 036659* 14 7/19.2 0.025 (0.64) 0.080 (2.03) 1.095 (27.8) 646 (961) 788 (1173)
TP16(IS-OS)XT-15 036660* 15 7/19.2 0.025 (0.64) 0.080 (2.03) 1.155 (29.3) 686 (1021) 835 (1242)
TP16(IS-OS)XT-16 036661* 16 7/19.2 0.025 (0.64) 0.080 (2.03) 1.155 (29.3) 719 (1070) 868 (1292)
TP16(IS-OS)XT-17 036662* 17 7/19.2 0.025 (0.64) 0.080 (2.03) 1.205 (24.2) 762 (1134) 918 (1366)
TP16(IS-OS)XT-18 036663* 18 7/19.2 0.025 (0.64) 0.080 (2.03) 1.205 (24.2) 792 (1178) 948 (1411)
TP16(IS-OS)XT-19 036664* 19 7/19.2 0.025 (0.64) 0.080 (2.03) 1.205 (24.2) 822 (1123) 978 (1455)
TP16(IS-OS)XT-20 036665* 20 7/19.2 0.025 (0.64) 0.080 (2.03) 1.265 (32.1) 861 (1281) 1025 (1525)
TP16(IS-OS)XT-21 036666* 21 7/19.2 0.025 (0.64) 0.080 (2.03) 1.265 (32.1) 895 (1332) 1059 (1576)
TP16(IS-OS)XT-22 036667* 22 7/19.2 0.025 (0.64) 0.080 (2.03) 1.335 (33.9) 940 (1399) 1113 (1656)
*NOTE: For aluminum armored versions, add an A (ex. 036646A). For bronze armored versions, add a B (ex. 036646B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
32
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 18 AWG 0.82 mm2 / 600V
A70
0_B
OST
MA
RIN
E_TY
PE X
_18A
WG
_Sig
nal_
2016
-11-
29
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
33
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE X
_18A
WG
_Sig
nal_
2016
-11-
29
BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 18 AWG 0.82 mm2 / 600V
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
Insulation Thicknessin (mm)
Jacket Thicknessin (mm)
Cable Diameter (nominal)in (mm)
Cable Weight (approximate)
Lbs/mft (Kg/km)
UNARMORED
TP18(IS)XT-1 036624 1 7/15.2 0.025 (0.64) 0.045 (1.14) 0.30 (7.6) 46 (68)
TP18(IS-OS)XT-2 036625 2 7/15.2 0.025 (0.64) 0.045 (1.14) 0.45 (11.4) 85 (126)
TP18(IS-OS)XT-3 036626 3 7/15.2 0.025 (0.64) 0.045 (1.14) 0.48 (12.2) 109 (162)
TP18(IS-OS)XT-4 036627 4 7/15.2 0.025 (0.64) 0.060 (1.52) 0.59 (15.0) 153 (228)
TP18(IS-OS)XT-5 036628 5 7/15.2 0.025 (0.64) 0.060 (1.52) 0.61 (15.5) 182 (271)
TP18(IS-OS)XT-6 036629 6 7/15.2 0.025 (0.64) 0.060 (1.52) 0.66 (16.8) 211 (314)
TP18(IS-OS)XT-7 036630 7 7/15.2 0.025 (0.64) 0.060 (1.52) 0.66 (16.8) 232 (346)
TP18(IS-OS)XT-8 036631 8 7/15.2 0.025 (0.64) 0.060 (1.52) 0.72 (18.3) 262 (390)
TP18(IS-OS)XT-9 036632 9 7/15.2 0.025 (0.64) 0.060 (1.52) 0.78 (19.8) 290 (432)
TP18(IS-OS)XT-10 036633 10 7/15.2 0.025 (0.64) 0.080 (2.03) 0.89 (22.6) 359 (534)
TP18(IS-OS)XT-11 036634 11 7/15.2 0.025 (0.64) 0.080 (2.03) 0.91 (23.1) 346 (516)
TP18(IS-OS)XT-12 036635 12 7/15.2 0.025 (0.64) 0.080 (2.03) 0.91 (23.1) 368 (548)
TP18(IS-OS)XT-13 036636 13 7/15.2 0.025 (0.64) 0.080 (2.03) 0.96 (24.4) 438 (652)
TP18(IS-OS)XT-14 036637 14 7/15.2 0.025 (0.64) 0.080 (2.03) 0.96 (24.4) 459 (684)
TP18(IS-OS)XT-15 036638 15 7/15.2 0.025 (0.64) 0.080 (2.03) 1.01 (25.7) 490 (729)
TP18(IS-OS)XT-16 036639 16 7/15.2 0.025 (0.64) 0.080 (2.03) 1.01 (25.7) 512 (762)
TP18(IS-OS)XT-17 036640 17 7/15.2 0.025 (0.64) 0.080 (2.03) 1.06 (26.9) 543 (808)
TP18(IS-OS)XT-18 036641 18 7/15.2 0.025 (0.64) 0.080 (2.03) 1.06 (26.9) 565 (840)
TP18(IS-OS)XT-19 036642 19 7/15.2 0.025 (0.64) 0.080 (2.03) 1.06 (26.9) 586 (872)
TP18(IS-OS)XT-20 036643 20 7/15.2 0.025 (0.64) 0.080 (2.03) 1.11 (28.2) 619 (921)
TP18(IS-OS)XT-21 036644 21 7/15.2 0.025 (0.64) 0.080 (2.03) 1.11 (28.2) 639 (951)
TP18(IS-OS)XT-22 036645 22 7/15.2 0.025 (0.64) 0.080 (2.03) 1.16 (29.5) 671 (998)
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
Insulation Thicknessin (mm)
Jacket Thicknessin (mm)
Armored Cable Diameterin (mm)
Aluminum Armored Cable
WeightLbs/mft (Kg/km)
BronzeArmored Cable
WeightLbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
TP18(IS)XT-1 036624* 1 7/15.2 0.025 (0.64) 0.045 (1.14) 0.355 (9.0) 65 (97) 108 (161) 122 (182)
TP18(IS-OS)XT-2 036625* 2 7/15.2 0.025 (0.64) 0.045 (1.14) 0.505 (12.8) 112 (167) 176 (262) 204 (304)
TP18(IS-OS)XT-3 036626* 3 7/15.2 0.025 (0.64) 0.045 (1.14) 0.535 (13.6) 138 (205) 206 (307) 265 (394)
TP18(IS-OS)XT-4 036627* 4 7/15.2 0.025 (0.64) 0.060 (1.52) 0.645 (16.4) 188 (280) 271 (403) 311 (463)
TP18(IS-OS)XT-5 036628* 5 7/15.2 0.025 (0.64) 0.060 (1.52) 0.665 (16.9) 219 (326) 303 (451) 360 (534)
TP18(IS-OS)XT-6 036629* 6 7/15.2 0.025 (0.64) 0.060 (1.52) 0.715 (18.2) 251 (373) 342 (509) 409 (609)
TP18(IS-OS)XT-7 036630* 7 7/15.2 0.025 (0.64) 0.060 (1.52) 0.715 (18.2) 272 (405) 363 (540) 439 (653)
TP18(IS-OS)XT-8 036631* 8 7/15.2 0.025 (0.64) 0.060 (1.52) 0.775 (19.7) 305 (454) 404 (601) 487 (725)
TP18(IS-OS)XT-9 036632* 9 7/15.2 0.025 (0.64) 0.060 (1.52) 0.835 (21.2) 336 (500) 444 (661) 544 (809)
TP18(IS-OS)XT-10 036633* 10 7/15.2 0.025 (0.64) 0.080 (2.03) 0.925 (23.5) 364 (542) 478 (711) 639 (951)
TP18(IS-OS)XT-11 036634* 11 7/15.2 0.025 (0.64) 0.080 (2.03) 0.965 (24.5) 393 (585) 512 (762) 680 (1012)
TP18(IS-OS)XT-12 036635* 12 7/15.2 0.025 (0.64) 0.080 (2.03) 0.965 (24.5) 422 (628) 546 (812) 709 (1055)
TP18(IS-OS)XT-13 036636* 13 7/15.2 0.025 (0.64) 0.080 (2.03) 1.015 (25.8) 495 (737) 626 (931) 758 (1128)
TP18(IS-OS)XT-14 036637* 14 7/15.2 0.025 (0.64) 0.080 (2.03) 1.015 (25.8) 516 (768) 647 (963) 788 (1173)
TP18(IS-OS)XT-15 036638* 15 7/15.2 0.025 (0.64) 0.080 (2.03) 1.065 (27.1) 550 (818) 687 (1022) 835 (1242)
TP18(IS-OS)XT-16 036639* 16 7/15.2 0.025 (0.64) 0.080 (2.03) 1.065 (27.1) 572 (851) 709 (1055) 868 (1292)
TP18(IS-OS)XT-17 036640* 17 7/15.2 0.025 (0.64) 0.080 (2.03) 1.115 (28.3) 605 (900) 750 (1116) 918 (1366)
TP18(IS-OS)XT-18 036641* 18 7/15.2 0.025 (0.64) 0.080 (2.03) 1.115 (28.3) 627 (933) 772 (1149) 948 (1411)
TP18(IS-OS)XT-19 036642* 19 7/15.2 0.025 (0.64) 0.080 (2.03) 1.115 (28.3) 648 (964) 793 (1180) 978 (1455)
TP18(IS-OS)XT-20 036643* 20 7/15.2 0.025 (0.64) 0.080 (2.03) 1.165 (29.6) 684 (1018) 835 (1242) 1025 (1525)
TP18(IS-OS)XT-21 036644* 21 7/15.2 0.025 (0.64) 0.080 (2.03) 1.165 (29.6) 704 (1048) 855 (1272) 1059 (1576)
TP18(IS-OS)XT-22 036645* 22 7/15.2 0.025 (0.64) 0.080 (2.03) 1.215 (30.9) 739 (1100) 897 (1335) 1113 (1656)
*NOTE: For aluminum armored versions, add an A (ex. 036624A). For bronze armored versions, add a B (ex. 036624B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.
34
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 20 AWG 0.52 mm2 / 300V
A70
0_B
OST
MA
RIN
E_TY
PE X
_20A
WG
_Sig
nal_
2016
-11-
30
Design Parameters
CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.
INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.
PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.
JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).
Specifications and Ratings
- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.
- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).
- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.
- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).
- Transport Canada Approved cables are available.
Applications
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.
Features
- IEEE STANDARD 45.8 (2016)
- IEEE STANDARD 1580 (2010)
- UL 1309 (2013)
- CSA 22.2 No. 245 (2015)
Lloyd’sRegister
35
Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas
A brand of the
A70
0_B
OST
MA
RIN
E_TY
PE X
_20A
WG
_Sig
nal_
2016
-11-
30
BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 20 AWG 0.52 mm2 / 300V
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
Insulation Thicknessin (mm)
Jacket Thicknessin (mm)
Cable Diameter (nominal)in (mm)
Cable Weight (approximate)
Lbs/mft (Kg/km)
UNARMORED
TP20(IS)XT-1 036602 1 7/12.1 0.025 (0.64) 0.045 (1.14) 0.28 (7.1) 36 (54)
TP20(IS-OS)XT-2 036603 2 7/12.1 0.025 (0.64) 0.045 (1.14) 0.41 (10.4) 64 (95)
TP20(IS-OS)XT-3 036604 3 7/12.1 0.025 (0.64) 0.045 (1.14) 0.43 (10.9) 80 (119)
TP20(IS-OS)XT-4 036605 4 7/12.1 0.025 (0.64) 0.045 (1.14) 0.48 (12.2) 97 (144)
TP20(IS-OS)XT-5 036606 5 7/12.1 0.025 (0.64) 0.060 (1.52) 0.55 (14.0) 132 (196)
TP20(IS-OS)XT-6 036607 6 7/12.1 0.025 (0.64) 0.060 (1.52) 0.60 (15.2) 152 (226)
TP20(IS-OS)XT-7 036608 7 7/12.1 0.025 (0.64) 0.060 (1.52) 0.60 (15.2) 164 (244)
TP20(IS-OS)XT-8 036609 8 7/12.1 0.025 (0.64) 0.060 (1.52) 0.65 (16.5) 185 (275)
TP20(IS-OS)XT-9 036610 9 7/12.1 0.025 (0.64) 0.060 (1.52) 0.69 (17.5) 204 (303)
TP20(IS-OS)XT-10 036611 10 7/12.1 0.025 (0.64) 0.060 (1.52) 0.75 (19.1) 226 (336)
TP20(IS-OS)XT-11 036612 11 7/12.1 0.025 (0.64) 0.060 (1.52) 0.78 (19.8) 242 (360)
TP20(IS-OS)XT-12 036613 12 7/12.1 0.025 (0.64) 0.060 (1.52) 0.78 (19.8) 256 (381)
TP20(IS-OS)XT-13 036614 13 7/12.1 0.025 (0.64) 0.060 (1.52) 0.82 (20.8) 275 (409)
TP20(IS-OS)XT-14 036615 14 7/12.1 0.025 (0.64) 0.060 (1.52) 0.82 (20.8) 289 (430)
TP20(IS-OS)XT-15 036616 15 7/12.1 0.025 (0.64) 0.080 (2.03) 0.90 (22.9) 346 (515)
TP20(IS-OS)XT-16 036617 16 7/12.1 0.025 (0.64) 0.080 (2.03) 0.90 (22.9) 359 (534)
TP20(IS-OS)XT-17 036618 17 7/12.1 0.025 (0.64) 0.080 (2.03) 0.95 (24.1) 381 (566)
TP20(IS-OS)XT-18 036619 18 7/12.1 0.025 (0.64) 0.080 (2.03) 0.95 (24.1) 395 (587)
TP20(IS-OS)XT-19 036620 19 7/12.1 0.025 (0.64) 0.080 (2.03) 0.95 (24.1) 408 (608)
TP20(IS-OS)XT-20 036621 20 7/12.1 0.025 (0.64) 0.080 (2.03) 0.99 (25.1) 429 (638)
TP20(IS-OS)XT-21 036622 21 7/12.1 0.025 (0.64) 0.080 (2.03) 0.99 (25.1) 444 (661)
TP20(IS-OS)XT-22 036623 22 7/12.1 0.025 (0.64) 0.080 (2.03) 1.04 (26.4) 466 (694)
TPC Cable TypePart
NumberNumberof Pairs
Stranding Type
Insulation Thicknessin (mm)
Jacket Thicknessin (mm)
Armored Cable Diameterin (mm)
Aluminum Armored Cable
WeightLbs/mft (Kg/km)
BronzeArmored Cable
WeightLbs/mft (Kg/km)
ALUMINUM OR BRONZE ARMORED
TP20(IS)XT-1 036602* 1 7/12.1 0.025 (0.64) 0.045 (1.14) 0.335 (8.5) 54 (80) 95 (141)
TP20(IS-OS)XT-2 036603* 2 7/12.1 0.025 (0.64) 0.045 (1.14) 0.465 (11.8) 89 (132) 147 (219)
TP20(IS-OS)XT-3 036604* 3 7/12.1 0.025 (0.64) 0.045 (1.14) 0.485 (12.3) 106 (158) 167 (248)
TP20(IS-OS)XT-4 036605* 4 7/12.1 0.025 (0.64) 0.045 (1.14) 0.535 (13.6) 126 (187) 194 (289)
TP20(IS-OS)XT-5 036606* 5 7/12.1 0.025 (0.64) 0.060 (1.52) 0.605 (15.4) 165 (246) 242 (360)
TP20(IS-OS)XT-6 036607* 6 7/12.1 0.025 (0.64) 0.060 (1.52) 0.655 (16.6) 188 (280) 271 (403)
TP20(IS-OS)XT-7 036608* 7 7/12.1 0.025 (0.64) 0.060 (1.52) 0.655 (16.6) 200 (298) 283 (421)
TP20(IS-OS)XT-8 036609* 8 7/12.1 0.025 (0.64) 0.060 (1.52) 0.705 (17.9) 224 (333) 314 (467)
TP20(IS-OS)XT-9 036610* 9 7/12.1 0.025 (0.64) 0.060 (1.52) 0.745 (18.9) 245 (365) 340 (506)
TP20(IS-OS)XT-10 036611* 10 7/12.1 0.025 (0.64) 0.060 (1.52) 0.805 (20.4) 271 (403) 374 (556)
TP20(IS-OS)XT-11 036612* 11 7/12.1 0.025 (0.64) 0.060 (1.52) 0.835 (21.2) 288 (429) 396 (589)
TP20(IS-OS)XT-12 036613* 12 7/12.1 0.025 (0.64) 0.060 (1.52) 0.835 (21.2) 302 (449) 410 (610)
TP20(IS-OS)XT-13 036614* 13 7/12.1 0.025 (0.64) 0.060 (1.52) 0.875 (22.2) 324 (482) 436 (649)
TP20(IS-OS)XT-14 036615* 14 7/12.1 0.025 (0.64) 0.060 (1.52) 0.875 (22.2) 338 (503) 450 (670)
TP20(IS-OS)XT-15 036616* 15 7/12.1 0.025 (0.64) 0.080 (2.03) 0.955 (24.3) 399 (594) 522 (777)
TP20(IS-OS)XT-16 036617* 16 7/12.1 0.025 (0.64) 0.080 (2.03) 0.955 (24.3) 412 (613) 535 (796)
TP20(IS-OS)XT-17 036618* 17 7/12.1 0.025 (0.64) 0.080 (2.03) 1.005 (25.5) 437 (650) 567 (844)
TP20(IS-OS)XT-18 036619* 18 7/12.1 0.025 (0.64) 0.080 (2.03) 1.005 (25.5) 451 (671) 584 (869)
TP20(IS-OS)XT-19 036620* 19 7/12.1 0.025 (0.64) 0.080 (2.03) 1.005 (25.5) 464 (690) 594 (884)
TP20(IS-OS)XT-20 036621* 20 7/12.1 0.025 (0.64) 0.080 (2.03) 1.045 (26.5) 487 (725) 622 (926)
TP20(IS-OS)XT-21 036622* 21 7/12.1 0.025 (0.64) 0.080 (2.03) 1.045 (26.5) 502 (747) 637 (948)
TP20(IS-OS)XT-22 036623* 22 7/12.1 0.025 (0.64) 0.080 (2.03) 1.095 (27.8) 527 (784) 669 (995)
*NOTE: For aluminum armored versions, add an A (ex. 036624A). For bronze armored versions, add a B (ex. 036624B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.