bostmarine product catalog - prysmian group · applications bostmarine type t/n 600 volt cables are...

36
BOSTMARINE Product Catalog Marine & Shipboard Cables A brand of the

Upload: others

Post on 17-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

BOSTMARINE Product CatalogMarine & Shipboard Cables

A brand of the

Page 2: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Control Cable (Multi-Conductor) .................................................................... 3

BOSTMARINE Type T/N Control Cable (Multi-Conductor, Shielded) ..................................................... 5

BOSTMARINE Type T/N Control Cable (Shielded Triads) ...................................................................... 7

BOSTMARINE Type T/N Power Cable (Two Conductor) ........................................................................ 9

BOSTMARINE Type T/N Power Cable (Three Conductor) ..................................................................... 11

BOSTMARINE Type T/N Power Cable (Four Conductor) .......................................................................13

BOSTMARINE Type T/N Signal Cable (14 AWG) ...................................................................................15

BOSTMARINE Type T/N Signal Cable (16 AWG) ...................................................................................17

BOSTMARINE Type T/N Signal Cable (18 AWG) ...................................................................................19

BOSTMARINE Type T/N Signal Cable (20 AWG) ..................................................................................21

BOSTMARINE Type X Control Cable (Multi Conductor) ....................................................................... 23

BOSTMARINE Type X Power Cable (Two Conductor) .......................................................................... 25

BOSTMARINE Type X Power Cable (Three Conductor) ........................................................................ 27

BOSTMARINE Type X Power Cable (Four Conductor) ......................................................................... 29

BOSTMARINE Type X Signal Cable (16 AWG) .......................................................................................31

BOSTMARINE Type X Signal Cable (18 AWG) ...................................................................................... 33

BOSTMARINE Type X Signal Cable (20 AWG) ..................................................................................... 35

Table of Contents

Page 3: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Control CableMulti-Conductor / Unarmored & Armored / 18, 16, and 14 AWG / 600V

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_C

ontr

ol C

able

_201

6-11

-17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Lloyd’sRegister

3

Page 4: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_C

ontr

ol C

able

_201

6-11

-17

A brand of the

BOSTMARINE Type T/N Control CableMulti-Conductor / Unarmored & Armored / 18, 16, and 14 AWG / 600V

TPC Cable Type

Part Number*Number of Conductors

Stranding Type

Total**Insulation Thickness

in (mm)

JacketThickness

in (mm)

CableDiameter

(nom)in (mm)

Cable Weight (approx)Lbs/mft(Kg/km)

Armored Cable Diameter

(nom)Lbs/mft(Kg/km)

Aluminum Arm. Cable

Weight Lbs/mft(Kg/km)

Bronze Arm. Cable Weight

Lbs/mft(Kg/km)

18 AWG • 1.0 mm2

C18T/NT-2 036125* 2 7/15.2 .019 (0.48) .045 (1.14) 0.28 (7.1) 35 (52) 0.33 (8.4) 53 (79) 94 (140)

C18T/NT-3 036126* 3 7/15.2 .019 (0.48) .045 (1.14) 0.29 (7.4) 44 (65) 0.34 (8.6) 62 (92) 105 (156)

C18T/NT-4 036127* 4 7/15.2 .019 (0.48) .045 (1.14) 0.31 (7.9) 53 (79) 0.36 (9.1) 72 (107) 117 (174)

C18T/NT-7 029781* 7 7/15.2 .019 (0.48) .045 (1.14) 0.36 (9.1) 86 (128) 0.41 (10.4) 108 (160) 160 (238)

C18T/NT-10 030630* 10 7/15.2 .019 (0.48) .060 (1.52) 0.45 (11.4) 117 (174) 0.50 (12.7) 144 (214) 208 (310)

C18T/NT-16 350376* 16 7/15.2 .019 (0.48) .060 (1.52) 0.57 (14.5) 210 (312) 0.63 (16.0) 244 (363) 324 (482)

C18T/NT-20 350377* 20 7/15.2 .019 (0.48) .060 (1.52) 0.63 (16.0) 255 (379) 0.69 (17.5) 292 (434) 379 (564)

C18T/NT-24 036131* 24 7/15.2 .019 (0.48) .060 (1.52) 0.65 (16.5) 262 (390) 0.70 (17.8) 301 (448) 391 (582)

C18T/NT-30 036132* 30 7/15.2 .019 (0.48) .060 (1.52) 0.69 (17.5) 310 (461) 0.74 (18.8) 351 (522) 446 (664)

C18T/NT-37 036133* 37 7/15.2 .019 (0.48) .060 (1.52) 0.74 (18.8) 372 (554) 0.79 (20.1) 416 (619) 518 (771)

C18T/NT-44 036134* 44 7/15.2 .019 (0.48) .060 (1.52) 0.86 (21.8) 471 (701) 0.91 (23.1) 522 (777) 640 (952)

C18T/NT-61 036135* 61 7/15.2 .019 (0.48) .080 (2.03) 0.95 (24.1) 612 (911) 1.00 (25.4) 668 (994) 798 (1187)

16 AWG • 1.3 mm2

C16T/NT-2 030109* 2 7/19.2 .019 (0.48) .045 (1.14) 0.30 (7.6) 49 (73) 0.35 (8.9) 68 (101) 111 (165)

C16T/NT-3 036115* 3 7/19.2 .019 (0.48) .045 (1.14) 0.31 (7.9) 53 (79) 0.36 (9.1) 72 (107) 117 (174)

C16T/NT-4 030131* 4 7/19.2 .019 (0.48) .045 (1.14) 0.34 (8.6) 72 (107) 0.39 (9.9) 93 (138) 142 (211)

C16T/NT-7 030111* 7 7/19.2 .019 (0.48) .045 (1.14) 0.39 (9.9) 114 (170) 0.44 (11.2) 138 (205) 194 (289)

C16T/NT-10 030137* 10 7/19.2 .019 (0.48) .045 (1.14) 0.50 (12.7) 159 (237) 0.55 (14.0) 189 (281) 259 (385)

C16T/NT-16 030136* 16 7/19.2 .019 (0.48) .060 (1.52) 0.63 (16.0) 273 (406) 0.69 (17.5) 310 (461) 397 (591)

C16T/NT-20 030148* 20 7/19.2 .019 (0.48) .060 (1.52) 0.69 (17.5) 334 (497) 0.75 (19.1) 375 (558) 470 (699)

C16T/NT-24 030149* 24 7/19.2 .019 (0.48) .060 (1.52) 0.72 (18.3) 358 (533) 0.77 (19.6) 401 (597) 500 (744)

C16T/NT-30 030150* 30 7/19.2 .019 (0.48) .060 (1.52) 0.77 (19.6) 431 (641) 0.82 (20.8) 477 (710) 583 (868)

C16T/NT-37 030132* 37 7/19.2 .019 (0.48) .080 (2.03) 0.87 (22.1) 556 (827) 0.92 (23.4) 608 (905) 727 (1082)

C16T/NT-44 030180* 44 7/19.2 .019 (0.48) .080 (2.03) 0.96 (24.4) 652 (970) 1.01 (25.7) 709 (1055) 840 (1250)

C16T/NT-61 036140* 61 7/19.2 .019 (0.48) .080 (2.03) 1.07 (27.2) 816 (1214) 1.12 (28.7) 879 (1308) 1025 (1525)

14 AWG • 2.1 mm2

C14T/NT-2 036141* 2 7/24.2 .019 (0.48) .045 (1.14) 0.33 (8.4) 62 (92) 0.38 (9.7) 83 (124) 130 (193)

C14T/NT-3 036142* 3 7/24.2 .019 (0.48) .045 (1.14) 0.35 (8.9) 81 (121) 0.40 (10.2) 103 (153) 153 (228)

C14T/NT-4 036143* 4 7/24.2 .019 (0.48) .045 (1.14) 0.37 (9.4) 101 (150) 0.42 (10.7) 124 (185) 177 (263)

C14T/NT-7 030129* 7 7/24.2 .019 (0.48) .045 (1.14) 0.44 (11.2) 157 (234) 0.49 (12.4) 184 (274) 246 (366)

C14T/NT-10 030108* 10 7/24.2 .019 (0.48) .060 (1.52) 0.58 (14.7) 240 (357) 0.63 (16.0) 275 (409) 356 (530)

C14T/NT-16 030152* 16 7/24.2 .015 (.004) .060 (1.52) 0.69 (17.5) 366 (545) 0.75 (19.1) 407 (606) 502 (747)

C14T/NT-20 030609* 20 7/24.2 .015 (.004) .060 (1.52) 0.74 (18.8) 451 (671) 0.80 (20.3) 495 (737) 596 (887)

C14T/NT-24 030151* 24 7/24.2 .019 (0.48) .060 (1.52) 0.81 (20.6) 494 (735) 0.86 (21.8) 542 (806) 653 (972)

C14T/NT-30 036147* 30 7/24.2 .019 (0.48) .080 (2.03) 0.90 (22.9) 639 (951) 0.95 (24.1) 692 (1030) 815 (1213)

C14T/NT-37 030153* 37 7/24.2 .019 (0.48) .080 (2.03) 0.96 (24.4) 762 (1134) 1.01 (25.7) 818 (1217) 950 (1414)

C14T/NT-44 036148* 44 7/24.2 .019 (0.48) .080 (2.03) 1.08 (27.4) 901 (1341) 1.13 (28.7) 965 (1436) 1112 (1655)

C14T/NT-61 036149* 61 7/24.2 .019 (0.48) .080 (2.03) 1.14 (29.0) 1210 (1801) 1.19 (30.2) 1277 (1900) 1432 (2131)

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).**NOTE: PVC/Nylon Insulation Thickness Inches(mm) - 0.015/.004(0.38/0.10) This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

4

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 5: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Control CableMulti-Conductor Shielded / Unarmored & Armored / 16 and 14 AWG / 600V

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

SHIELD: An aluminum/polyester tape with drain wire, 100% coverage, is applied over the cabled core.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_S

hiel

ded

Cont

rol C

able

_201

6-11

-17

Lloyd’sRegister

5

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 6: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_S

hiel

ded

Cont

rol C

able

_201

6-11

-17

BOSTMARINE Type T/N Control CableMulti-Conductor Shielded/ Unarmored & Armored / 16 and 14 AWG / 600V

TPC Cable Type

Part Number*Number of Conductors

Stranding Type

Total**Insulation Thickness

in (mm)

JacketThickness

in (mm)

CableDiameter

(nom)in (mm)

Cable Weight (approx)Lbs/mft(Kg/km)

Armored Cable Diameter

(nom)Lbs/mft(Kg/km)

Aluminum Arm. Cable

Weight Lbs/mft(Kg/km)

Bronze Arm. Cable Weight

Lbs/mft(Kg/km)

16 AWG • 1.3 mm2

C16(OS)T/NT-2 2 7/19.2 .019 (0.48) .045 (1.14) 0.31 (7.9) 58 (86) 0.37 (9.4) 77 (115) 122 (182)

C16(OS)T/NT-3 3 7/19.2 .019 (0.48) .045 (1.14) 0.33 (8.4) 63 (94) 0.39 (9.9) 83 (124) 130 (193)

C16(OS)T/NT-4 4 7/19.2 .019 (0.48) .045 (1.14) 0.35 (8.9) 82 (122) 0.41 (10.4) 103 (153) 153 (228)

C16(OS)T/NT-7 030631* 7 7/19.2 .019 (0.48) .045 (1.14) 0.42 (10.7) 124 (185) 0.48 (12.2) 150 (305) 209 (311)

C16(OS)T/NT-10 030632* 10 7/19.2 .019 (0.48) .045 (1.14) 0.55 (14.0) 169 (251) 0.58 (14.7) 200 (418) 273 (406)

C16(OS)T/NT-16 030633* 16 7/19.2 .019 (0.48) .060 (1.52) 0.63 (16.0) 281 (418) 0.69 (17.5) 319 (475) 406 (604)

C16(OS)T/NT-20 030634* 20 7/19.2 .019 (0.48) .060 (1.52) 0.70 (17.8) 343 (510) 0.76 (19.3) 385 (573) 480 (714)

C16(OS)T/NT-24 036753* 24 7/19.2 .019 (0.48) .060 (1.52) 0.76 (19.3) 371 (552) 0.82 (20.8) 416 (619) 521 (775)

C16(OS)T/NT-30 30 7/19.2 .019 (0.48) .060 (1.52) 0.81 (20.6) 444 (661) 0.87 (22.1) 492 (733) 602 (896)

C16(OS)T/NT-37 030635* 37 7/19.2 .019 (0.48) .080 (2.03) 0.91 (23.1) 569 (847) 0.97 (24.6) 623 (927) 747 (1112)

C16(OS)T/NT-44 030180* 44 7/19.2 .019 (0.48) .080 (2.03) 1.03 (26.2) 666 (991) 1.09 (27.7) 727 (1082) 867 (1290)

C16(OS)T/NT-61 036140* 61 7/19.2 .019 (0.48) .080 (2.03) 1.13 (28.7) 830 (1235) 1.19 (30.2) 896 (1333) 1049 (1561)

14 AWG • 2.1 mm2

C14(OS)T/NT-2 036141* 2 7/24.2 .019 (0.48) .045 (1.14) 0.34 (8.6) 75 (112) 0.40 (10.2) 96 (143) 145 (216)

C14(OS)T/NT-3 036142* 3 7/24.2 .019 (0.48) .045 (1.14) 0.36 (9.1) 94 (140) 0.42 (10.7) 116 (173) 167 (248)

C14(OS)T/NT-4 036143* 4 7/24.2 .019 (0.48) .045 (1.14) 0.42 (10.7) 115 (171) 0.48 (12.2) 140 (208) 219 (326)

C14(OS)T/NT-7 036745* 7 7/24.2 .019 (0.48) .045 (1.14) 0.46 (11.6) 171 (254) 0.52 (13.2) 199 (296) 273 (406)

C14(OS)T/NT-10 030648* 10 7/24.2 .019 (0.48) .060 (1.52) 0.58 (14.7) 254 (377) 0.64 (16.3) 206 (307) 369 (549)

C14(OS)T/NT-16 350374* 16 7/24.2 .015 (.004) .060 (1.52) 0.63 (16.0) 378 (562) 0.75 (19.1) 419 (623) 514 (765)

C14(OS)T/NT-20 350375* 20 7/24.2 .015 (.004) .060 (1.52) 0.71 (18.0) 462 (687) 0.82 (20.8) 507 (754) 612 (911)

C14(OS)T/NT-24 24 7/24.2 .019 (0.48) .060 (1.52) 0.84 (21.3) 510 (759) 0.90 (22.9) 560 (833) 675 (1004)

C14(OS)T/NT-30 30 7/24.2 .019 (0.48) .080 (2.03) 0.93 (23.6) 655 (975) 0.99 (25.1) 710 (1056) 837 (1245)

C14(OS)T/NT-37 37 7/24.2 .019 (0.48) .080 (2.03) 1.00 (25.4) 778 (1158) 1.06 (26.9) 837 (1245) 972 (1446)

C14(OS)T/NT-44 036148* 44 7/24.2 .019 (0.48) .080 (2.03) 1.13 (28.7) 917 (1364) 1.19 (30.2) 983 (1463) 1137 (1692)

C14(OS)T/NT-61 036149* 61 7/24.2 .019 (0.48) .080 (2.03) 1.18 (30.0) 1226 (1824) 1.24 (31.5) 1295 (1927) 1456 (2167)

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).**NOTE: PVC/Nylon Insulation Thickness Inches(mm) - 0.015/.004(0.38/0.10) This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

6

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 7: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Control CableIndividual & Overall Shielded Triads / Unarmored & Armored / 18, 16, and 14 AWG / 600V

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_S

hiel

ded

Tria

ds_2

016-

11-1

7

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

TRIAD SHIELD: Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

7

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 8: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_S

hiel

ded

Tria

ds_2

016-

11-1

7

BOSTMARINE Type T/N Control CableIndividual & Overall Shielded Triads/ Unarmored & Armored / 18, 16 and 14 AWG / 600V

TPC Cable TypePart

Number*Number of

TriadsStranding

Type

Total**Insulation Thickness

in (mm)

JacketThickness

in (mm)

CableDiameter

(nom)in (mm)

Cable Weight (approx)Lbs/mft(Kg/km)

Armored Cable Diameter

(nom)Lbs/mft(Kg/km)

Aluminum Arm. Cable

Weight Lbs/mft(Kg/km)

Bronze Arm. Cable Weight

Lbs/mft(Kg/km)

18 AWG • 1.0 mm2

TT18(OS)T/NT-1 350370 1 7/15.2 .019 (0.48) .045 (1.14) 0.31 (7.9) 56 (83) 0.37 (9.4) 75 (112) 119 (177)

TT18(IS-OS)T/NT-3 350371 3 7/15.2 .019 (0.48) .060 (1.52) 0.59 (15.0) 174 (259) 0.65 (16.5) 209 (311) 291 (433)

TT18(IS-OS)T/NT-6 350372 6 7/15.2 .019 (0.48) .060 (1.52) 0.76 (19.3) 294 (437) 0.82 (20.8) 339 (504) 444 (661)

TT18(IS-OS)T/NT-12 350373 12 7/15.2 .019 (0.48) .080 (2.03) 1.05 (26.7) 567 (844) 1.11 (28.2) 629 (936) 772 (1149)

16 AWG • 1.3 mm2

TT16(IS-OS)T/NT-1 350366 1 7/19.2 .019 (0.48) .045 (1.14) 0.33 (8.4) 70 (104) 0.39 (9.9) 91 (135) 138 (205)

TT16(IS-OS)T/NT-3 350367 3 7/19.2 .019 (0.48) .060 (1.52) 0.64 (16.3) 222 (330) 0.70 (17.8) 260 (387) 349 (519)

TT16(IS-OS)T/NT-6 350368 6 7/19.2 .019 (0.48) .060 (1.52) 0.84 (21.3) 380 (565) 0.90 (22.9) 430 (640) 555 (826)

TT16(IS-OS)T/NT-12 350369 12 7/19.2 .019 (0.48) .080 (2.03) 1.15 (29.2) 683 (1016) 1.21 (30.7) 751 (1117) 907 (1350)

14 AWG • 2.1 mm2

TT14(IS-OS)T/NT-1 350362 1 7/24.2 .019 (0.48) .045 (1.14) 0.36 (9.1) 93 (138) 0.42 (10.7) 115 (171) 166 (247)

TT14(IS-OS)T/NT-3 350363 3 7/24.2 .019 (0.48) .060 (1.52) 0.70 (17.8) 294 (437) 0.76 (19.3) 336 (500) 431 (641)

TT14(IS-OS)T/NT-6 350364 6 7/24.2 .019 (0.48) .060 (1.52) 0.96 (24.4) 558 (830) 1.02 (25.9) 614 (914) 745 (1109)

TT14(IS-OS)T/NT-12 350365 12 7/24.2 .019 (0.48) .080 (2.03) 1.26 (32.0) 1007 (1498) 1.32 (33.5) 1081 (1609) 1251 (1861)

*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B).**NOTE: PVC/Nylon Insulation Thickness Inches(mm) - 0.015/.004(0.38/0.10) This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

8

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 9: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Power CableTwo Conductor Power Distribution / Unarmored & Armored / 14 AWG to 500 MCM / 600V

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_2

C_Po

wer

_201

6-11

-21

Lloyd’sRegister

9

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 10: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_2

C_Po

wer

_201

6-11

-21

BOSTMARINE Type T/N Power CableTwo Conductor/ Unarmored & Armored / 14 AWG to 500 MCM / 600V

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)Stranding Type

PVC/NylonInsulation Thickness

in (mm)

JacketThickness

in (mm)

Cable Diameter(nominal)in (mm)

Cable Weight(approximate)

Lbs/mft (Kg/km)

UNARMORED

DT/NT-4 030103 14 (2.1) 7/24.2 .015/.004 (0.38/0.10) 0.045 (1.14) 0.33 (8.4) 66 (98)

DT/NT-6 030123 12 (3.3) 7/30.5 .015/.004 (0.38/0.10) 0.045 (1.14) 0.37 (9.4) 88 (131)

DT/NT-10 030114 10 (5.3) 7/38.5 .020/.004 (0.51/0.10) 0.045 (1.14) 0.43 (10.9) 133 (198)

DT/NT-16 030138 8 (8.4) 7/48.6 .030/.005 (0.76/0.13) 0.060 (1.52) 0.58 (14.7) 216 (321)

DT/NT-26 030139 6 (13.3) 7/61.2 .030/.005 (0.76/0.13) 0.060 (1.52) 0.65 (16.5) 311 (463)

DT/NT-41 030182 4 (21.1) 7/77.2 .040/.006 (1.02/0.15) 0.060 (1.52) 0.80 (20.3) 479 (713)

DT/NT-66 036090 2 (33.6) 7/97.4 .040/.006 (1.02/0.15) 0.080 (2.03) 0.97 (24.6) 727 (1082)

DT/NT-83 036091 1 (42.4) 19/66.4 .050/.007 (1.27/0.18) 0.080 (2.03) 1.00 (25.4) 933 (1388)

DT/NT-106 036092 1/0 (53.5) 19/74.5 .050/.007 (.127/0.18) 0.080 (2.03) 1.18 (30.0) 1110 (1652)

DT/NT-133 036093 2/0 (67.4) 19/83.7 .050/.007 (1.27/0.18) 0.080 (2.03) 1.27 (32.3) 1323 (1969)

DT/NT-168 036094 3/0 (85.0) 19/94.0 .050/.007 (1.27/0.18) 0.080 (2.03) 1.38 (35.1) 1602 (2384)

DT/NT-212 036095 4/0 (107.2) 19/105.5 .050/.007 (1.27/0.18) 0.080 (2.03) 1.56 (39.6) 2122 (3158)

DT/NT-250 036096 250 (127.0) 37/82.2 .060/.008 (1.52/0.20) 0.080 (2.03) 1.62 (41.1) 2337 (3478)

DT/NT-300 036097 300 (152.0) 37/90.0 .060/.008 (1.52/0.20) 0.110 (2.79) 1.80 (45.7) 2851 (4243)

DT/NT-350 036049 350 (177.0) 37/97.3 .060/.008 (1.52/0.20) 0.110 (2.79) 1.90 (48.3) 3303 (4915)

DT/NT-400 036098 400 (203.0) 37/104.0 .060/.008 (1.52/0.20) 0.110 (2.79) 2.08 (52.8) 3662 (5450)

DT/NT-500 036099 500 (253.0) 37/116.2 .060/.008 (1.52/0.20) 0.110 (2.79) 2.17 (55.1) 4497 (6692)

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

JacketThickness

in (mm)

Armored CableDiameterin (mm)

Aluminum Armor Cable Weight

Lbs/mft (Kg/km)

Bronze ArmorCable Weight

Lbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

DT/NT-4 030103* 14 (2.1) 7/24.2 .015/.004 (0.38/0.10) 0.045 (1.14) 0.38 (9.7) 86 (128) 132 (196)

DT/NT-6 030123* 12 (3.3) 7/30.5 .015/.004 (0.38/0.10) 0.045 (1.14) 0.42 (10.7) 110 (164) 162 (240)

DT/NT-10 030114* 10 (5.3) 7/38.5 .020/.004 (0.51/0.10) 0.045 (1.14) 0.48 (12.5) 159 (237) 218 (324)

DT/NT-16 030138* 8 (8.4) 7/48.6 .030/.005 (0.76/0.13) 0.060 (1.52) 0.63 (16.0) 250 (372) 329 (490)

DT/NT-26 030139* 6 (13.3) 7/61.2 .030/.005 (0.76/0.13) 0.060 (1.52) 0.70 (17.8) 351 (522) 437 (650)

DT/NT-41 030182* 4 (21.1) 7/77.2 .040/.006 (1.02/0.15) 0.060 (1.52) 0.85 (21.6) 530 (789) 633 (942)

DT/NT-66 036090* 2 (33.6) 7/97.4 .040/.006 (1.02/0.15) 0.080 (2.03) 1.02 (27.2) 791 (1177) 912 (1357)

DT/NT-83 036091* 1 (42.4) 19/66.4 .050/.007 (1.27/0.18) 0.080 (2.03) 1.05 (30.8) 991 (1475) 1124 (1673)

DT/NT-106 036092* 1/0 (53.5) 19/74.5 .050/.007 (1.27/0.18) 0.080 (2.03) 1.23 (32.8) 1178 (1753) 1334 (1985)

DT/NT-133 036093* 2/0 (67.4) 19/83.7 .050/.007 (1.27/0.18) 0.080 (2.03) 1.32 (35.8) 1396 (2077) 1564 (2327)

DT/NT-168 036094* 3/0 (85.0) 19/94.0 .050/.007 (1.27/0.18) 0.080 (2.03) 1.43 (38.1) 1681 (2501) 1863 (2772)

DT/NT-212 036095* 4/0 (107.2) 19/105.5 .050/.007 (1.27/0.18) 0.080 (2.03) 1.61 (41.7) 2211 (3290) 2416 (3595)

DT/NT-250 036096* 250 (127.0) 37/82.2 .060/.008 (1.52/0.20) 0.080 (2.03) 1.67 (47.0) 2429 (3614) 2643 (3933)

DT/NT-300 036097* 300 (152.0) 37/90.0 .060/.008 (1.52/0.20) 0.110 (2.79) 1.85 (49.8) 2953 (4394) 3190 (4747)

DT/NT-350 036049* 350 (177.0) 37/97.3 .060/.008 (1.52/0.20) 0.110 (2.79) 1.95 (49.6) 3411 (5076) 3660 (5446)

DT/NT-400 036098* 400 (203.0) 37/104.0 .060/.008 (1.52/0.20) 0.110 (2.79) 2.13 (54.1) 3780 (5625) 4053 (6031)

DT/NT-500 036099* 500 (253.0) 37/116.2 .060/.008 (1.52/0.20) 0.110 (2.79) 2.22 (56.4) 4620 (6875) 4904 (7297)

10

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 11: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Power CableThree Conductor Power Distribution / Unarmored & Armored / 14 AWG to 750 MCM / 600V

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_3

C_Po

wer

_201

6-11

-21

Lloyd’sRegister

11

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 12: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_3

C_Po

wer

_201

6-11

-21

BOSTMARINE Type T/N Power CableThree Conductor/ Unarmored & Armored / 14 AWG to 750 MCM / 600V

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)Stranding Type

PVC/NylonInsulation Thickness

in (mm)

JacketThickness

in (mm)

Cable Diameter(nominal)in (mm)

Cable Weight(approximate)

Lbs/mft (Kg/km)

UNARMORED

TT/NT-4 030101 14 (2.1) 7/24.2 .015/.004 (.038/0.10) 0.045 (1.14) 0.35 (8.9) 86 (128)

TT/NT-6 030102 12 (3.3) 7/30.5 .015/.004 (.038/0.10) 0.045 (1.14) 0.39 (9.9) 120 (179)

TT/NT-10 030107 10 (5.3) 7/38.5 .020/.004 (.051/0.10) 0.045 (1.14) 0.46 (11.7) 171 (254)

TT/NT-16 030106 8 (8.4) 7/48.6 .030/.005 (0.76/0.13) 0.060 (1.52) 0.61 (15.5) 301 (448)

TT/NT-26 030105 6 (13.3) 7/61.2 .030/.005 (0.76/0.13) 0.060 (1.52) 0.69 (17.5) 406 (604)

TT/NT-41 030110 4 (21.1) 7/77.2 .040/.006 (1.02/0.15) 0.080 (2.03) 0.84 (21.3) 664 (988)

TT/NT-66 030112 2 (33.6) 7/97.4 .040/.006 (1.02/0.15) 0.080 (2.03) 1.02 (25.9) 980 (1458)

TT/NT-83 036102 1 (42.4) 19/66.4 .050/.007 (.127/0.18) 0.080 (2.03) 1.16 (29.5) 1228 (1827)

TT/NT-106 030178 1/0 (53.5) 19/74.5 .050/.007 (.127/0.18) 0.080 (2.03) 1.24 (31.5) 1557 (2317)

TT/NT-133 036103 2/0 (67.4) 19/83.7 .050/.007 (.127/0.18) 0.080 (2.03) 1.36 (34.5) 1828 (2720)

TT/NT-168 036104 3/0 (85.0) 19/94.0 .050/.007 (.127/0.18) 0.080 (2.03) 1.45 (36.8) 2244 (3339)

TT/NT-212 036105 4/0 (107.2) 19/105.5 .050/.007 (.127/0.18) 0.080 (2.03) 1.59 (40.4) 2773 (4127)

TT/NT-250 036106 250 (127.0) 37/82.2 .060/.008 (1.52/0.20) 0.110 (2.79) 1.80 (45.7) 3360 (5000)

TT/NT-300 036107 300 (152.0) 37/90.0 .060/.008 (1.52/0.20) 0.110 (2.79) 1.91 (48.5) 3920 (5834)

TT/NT-350 036108 350 (177.0) 37/97.3 .060/.008 (1.52/0.20) 0.110 (2.79) 2.05 (52.1) 4550 (6771)

TT/NT-400 036109 400 (203.0) 37/104.0 .060/.008 (1.52/0.20) 0.110 (2.79) 2.22 (56.4) 5133 (7639)

TT/NT-500 036110 500 (253.0) 37/116.2 .060/.008 (1.52/0.20) 0.110 (2.79) 2.45 (62.2) 6472 (9631)

TT/NT-600 036111 600 (304.0) 61/99.2 .070/.009 (1.78/0.22) 0.110 (2.79) 2.52 (64.0) 7375 (10,975)

TT/NT-750 036112 750 (380.0) 61/110.9 .070/0.009 (1.78/0.22) 0.110 (2.79) 2.83 ( 71.9) 9200 (13,691)

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

JacketThickness

in (mm)

Armored CableDiameterin (mm)

Aluminum Armor Cable Weight

Lbs/mft (Kg/km)

Bronze ArmorCable Weight

Lbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

TT/NT-4 030101* 14 (2.1) 7/24.2 .015/.004 (.038/0.10) 0.045 (1.14) 0.38 (9.7) 107 (159) 156 (232)

TT/NT-6 030102* 12 (3.3) 7/30.5 .015/.004 (.038/0.10) 0.045 (1.14) 0.44 (11.2) 143 (213) 198 (295)

TT/NT-10 030107* 10 (5.3) 7/38.5 .020/.004 (.051/0.10) 0.045 (1.14) 0.51 (13.0) 198 (295) 262 (390)

TT/NT-16 030106* 8 (8.4) 7/48.6 .030/.005 (0.76/0.13) 0.060 (1.52) 0.66 (16.8) 337 (501) 419 (623)

TT/NT-26 030105* 6 (13.3) 7/61.2 .030/.005 (0.76/0.13) 0.060 (1.52) 0.74 (18.8) 446 (664) 539 (802)

TT/NT-41 030110* 4 (21.1) 7/77.2 .040/.006 (1.02/0.15) 0.080 (2.03) 0.89 (22.6) 713 (1061) 825 (1228)

TT/NT-66 030112* 2 (33.6) 7/97.4 .040/.006 (1.02/0.15) 0.080 (2.03) 1.07 (27.2) 1039 (1626) 1174 (1747)

TT/NT-83 036102* 1 (42.4) 19/66.4 .050/.007 (.127/0.18) 0.080 (2.03) 1.21 (30.8) 1295 (1927) 1448 (2155)

TT/NT-106 030178* 1/0 (53.5) 19/74.5 .050/.007 (.127/0.18) 0.080 (2.03) 1.29 (32.8) 1628 (2422) 1792 (2666)

TT/NT-133 036103* 2/0 (67.4) 19/83.7 .050/.007 (.127/0.18) 0.080 (2.03) 1.41 (35.8) 1906 (2836) 2085 (3102)

TT/NT-168 036104* 3/0 (85.0) 19/94.0 .050/.007 (.127/0.18) 0.080 (2.03) 1.50 (38.1) 2327 (3463) 2518 (3747)

TT/NT-212 036105* 4/0 (107.2) 19/105.5 .050/.007 (.12/0.18) 0.080 (2.03) 1.64 (41.7) 2864 (4262) 3073 (4573)

TT/NT-250 036106* 250 (127.0) 37/82.2 .060/.008 (1.52/0.20) 0.110 (2.79) 1.85 (47.0) 3462 (5151) 3699 (5504)

TT/NT-300 036107* 300 (152.0) 37/90.0 .060/.008 (1.52/0.20) 0.110 (2.79) 1.96 (49.8) 4029 (5995) 4280 (6369)

TT/NT-350 036108* 350 (177.0) 37/97.3 .060/.008 (1.52/0.20) 0.110 (2.79) 2.10 (53.4) 4666 (6943) 4935 (7343)

TT/NT-400 036109* 400 (203.0) 37/104.0 .060/.008 (1.52/0.20) 0.110 (2.79) 2.27 (57.7) 5259 (7825) 5550 (8258)

TT/NT-500 036110* 500 (253.0) 37/116.2 .060/.008 (1.52/0.20) 0.110 (2.79) 2.50 (63.5) 6611 (9837) 6932 (10,315)

TT/NT-600 036111* 600 (304.0) 61/99.2 .070/.009 (1.78/0.22) 0.110 (2.79) 2.57 (65.3) 7518 (11,187) 7847 (11,676)

TT/NT-750 036112* 750 (380.0) 61/110.9 .070/0.009 (1.78/0.22) 0.110 (2.79) 2.88 (73.2) 9360 (13,928) 9730 (14,478)

12

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 13: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Power CableFour Conductor Power Distribution / Unarmored & Armored / 14 AWG to 750 MCM / 600V

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_4

C_Po

wer

_201

6-11

-21

Lloyd’sRegister

13

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 14: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_4

C_Po

wer

_201

6-11

-21

BOSTMARINE Type T/N Power CableFour Conductor/ Unarmored & Armored / 14 AWG to 750 MCM / 600V

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)Stranding Type

PVC/NylonInsulation Thickness

in (mm)

JacketThickness

in (mm)

Cable Diameter(nominal)in (mm)

Cable Weight(approximate)

Lbs/mft (Kg/km)

UNARMORED

FT/NT-4 030104 14 (2.1) 7/24.2 0.015/.004 (0.38/0.10) 0.045 (1.14) 0.39 (9.9) 151 (225)

FT/NT-6 030130 12 (3.3) 7/30.5 0.015/.004 (0.38/0.10) 0.045 (1.14) 0.43 (10.9) 225 (335)

FT/NT-10 030128 10 (5.3) 7/38.5 0.020/.004 (0.51/0.10) 0.045 (1.14) 0.51 (13.0) 366 (545)

FT/NT-16 030135 8 (8.4) 7/48.6 0.030/.005 (0.76/0.13) 0.060 (1.52) 0.66 (16.8) 536 (798)

FT/NT-26 030134 6 (13.3) 7/61.2 0.030/.005 (0.76/0.13) 0.060 (1.52) 0.77 (19.6) 878 (1307)

FT/NT-41 030133 4 (21.1) 7/77.2 0.040/.006 (1.02/0.15) 0.080 (2.03) 0.99 (25.1) 1268 (1887)

FT/NT-66 030179 2 (33.6) 7/97.4 0.040/.006 (1.02/0.15) 0.080 (2.03) 1.13 (28.7) 1598 (2378)

FT/NT-83 036114 1 (42.4) 19/66.4 0.050/.007 (1.27/0.18) 0.080 (2.03) 1.27 (32.3) 1924 (2863)

FT/NT-106 036115 1/0 (53.5) 19/74.5 0.050/.007 (1.27/0.18) 0.080 (2.03) 1.38 (35.1) 2374 (3533)

FT/NT-133 036116 2/0 (67.4) 19/83.7 0.050/.007 (1.27/0.18) 0.080 (2.03) 1.49 (37.8) 2569 (3823)

FT/NT-168 036117 3/0 (85.0) 19/94.0 0.050/.007 (1.27/0.18) 0.080 (2.03) 1.61 (40.9) 2850 (4241)

FT/NT-212 030177 4/0 (107.2) 19/105.5 0.050/.007 (1.27/0.18) 0.110 (2.79) 1.82 (46.2) 3650 (5432)

FT/NT-250 036118 250 (127.0) 37/82.2 0.060/.008 (1.52/0.20) 0.110 (2.79) 1.98 (50.3) 4319 (6427)

FT/NT-300 036119 300 (152.0) 37/90.0 0.060/.008 (1.52/0.20) 0.110 (2.79) 2.11 (53.6) 5051 (7517)

FT/NT-350 036120 350 (177.0) 37/97.3 0.060/.008 (1.52/0.20) 0.110 (2.79) 2.34 (59.4) 5866 (8730)

FT/NT-400 036121 400 (203.0) 37/104.0 0.060/.008 (1.52/0.20) 0.110 (2.79) 2.46 (62.5) 6623 (9856)

FT/NT-500 036122 500 (253.0) 37/116.2 0.060/.008 (1.52/0.20) 0.110 (2.79) 2.56 (65.0) 8086 (12,033)

FT/NT-600 036123 600 (304.0) 61/99.2 0.070/.009 (1.78/0.23) 0.140 (3.56) 2.87 (72.9) 9657 (14,371)

FT/NT-750 036124 750 (380.0) 61/110.9 0.070/.009 (1.78/0.23) 0.140 (3.56) 3.11 ( 79.0) 11,949 (17,782)

*NOTE: For aluminum armored versions, add an A (ex. 030104A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)

Stranding Type

PVC/Nylon Insulation Thickness

in (mm)

JacketThickness

in (mm)

Armored CableDiameterin (mm)

Aluminum Armor Cable Weight

Lbs/mft (Kg/km)

Bronze ArmorCable Weight

Lbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

FT/NT-4 030104* 14 • 2.1 7/24.2 0.015/.004 (0.38/0.10) .045 (1.14) 0.44 (11.2) 174 (259) 229 (341)

FT/NT-6 030130* 12 • 3.3 7/30.5 0.015/.004 (0.38/0.10) .045 (1.14) 0.48 (12.2) 251 (373) 310 (461)

FT/NT-10 030128* 10 • 5.3 7/38.5 0.020/.004 (0.51/0.10) .045 (1.14) 0.56 (14.2) 396 (589) 466 (693)

FT/NT-16 030135* 8 • 8.4 7/48.6 0.030/.005 (0.76/0.13) .060 (1.52) 0.71 (18.1) 575 (856) 664 (988)

FT/NT-26 030134* 6 • 13.3 7/61.2 0.030/.005 (0.76/0.13) .060 (1.52) 0.82 (20.9) 923 (1373) 1026 (1527)

FT/NT-41 030133* 4 • 21.1 7/77.2 0.040/.006 (1.02/0.15) .080 (2.03) 1.04 (26.4) 1325 (1971) 1457 (2168)

FT/NT-66 030179* 2 • 33.6 7/97.4 0.040/.006 (1.02/0.15) .080 (2.03) 1.18 (30.0) 1663 (2475) 1813 (2698)

FT/NT-83 036114* 1 • 42.4 19/66.4 0.050/.007 (1.27/0.18) .080 (2.03) 1.32 (33.8) 1997 (2972) 2165 (3222)

FT/NT-106 036115* 1/0 • 53.5 19/74.5 0.050/.007 (1.27/0.18) .080 (2.03) 1.43 (36.3) 2453 (3650) 2635 (3921)

FT/NT-133 036116* 2/0 • 67.4 19/83.7 0.050/.007 (1.27/0.18) .080 (2.03) 1.54 (39.1) 2654 (3949) 2850 (4241)

FT/NT-168 036117* 3/0 • 85.0 19/94.0 0.050/.007 (1.27/0.18) .080 (2.03) 1.66 (42.2) 2942 (4378) 3154 (4693)

FT/NT-212 030177* 4/0 • 107.2 19/105.5 0.050/.007 (1.27/0.18) .110 (2.79) 1.87 (47.5) 3753 (5584) 3993 (5942)

FT/NT-250 036118* 250 • 127.0 37/82.2 0.060/.008 (1.52/0.20) .110 (2.79) 2.03 (51.6) 4431 (6593) 4691 (6980)

FT/NT-300 036119* 300 • 152.0 37/90.0 0.060/.008 (1.52/0.20) .110 (2.79) 2.16 (54.9) 5171 (7694) 5447 (8105)

FT/NT-350 036120* 350 • 177.0 37/97.3 0.060/.008 (1.52/0.20) .110 (2.79) 2.39 (60.7) 5999 (8927) 6305 (9382)

FT/NT-400 036121* 400 • 203.0 37/104.0 0.060/.008 (1.52/0.20) .110 (2.79) 2.51 (63.8) 6762 (10,062) 7084 (10,541)

FT/NT-500 036122* 500 • 253.0 37/116.2 0.060/.008 (1.52/0.20) .110 (2.79) 2.61 (66.3) 8235 (12,254) 8566 (12,746)

FT/NT-600 036123* 600 • 304.0 61/99.2 0.070/.009 (1.78/0.23) .140 (3.56) 2.92 (74.2) 9819 (14,611) 10,194 (15,169)

FT/NT-750 036124* 750 • 380.0 61/110.9 0.070/.009 (1.78/0.23) .140 (3.56) 3.16 (80.3) 12,125 (18,042) 12,531 (18,646)

14

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 15: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 14 AWG 2.1 mm2 / 600V

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_1

4AW

G_S

igna

l_20

16-1

1-22

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

15

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 16: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_1

4AW

G_S

igna

l_20

16-1

1-22

BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 14 AWG 2.1 mm2 / 600V

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

Jacket Thicknessin (mm)

Cable Diameter (nominal)in (mm)

Cable Weight (approximate)

Lbs/mft (Kg/km)

UNARMORED

TP14(IS-OS)T/NT-1 350356 1 7/24.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.340 (8.6) 73 (109)

TP14(IS-OS)T/NT-2 030186 2 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.575 (14.6) 175 (260)

TP14(IS-OS)T/NT-3 350358 3 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.605 (15.4) 228 (339)

TP14(IS-OS)T/NT-4 030188 4 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.665 (16.9) 282 (420)

TP14(IS-OS)T/NT-6 030189 6 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.790 (20.1) 392 (583)

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

Jacket Thicknessin (mm)

Armored Cable Diameterin (mm)

Aluminum Armored Cable

WeightLbs/mft (Kg/km)

BronzeArmored Cable

WeightLbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

TP14(IS-OS)T/NT-1 350356* 1 7/24.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.400 (10.2) 94 (140) 143 (213)

TP14(IS-OS)T/NT-2 030186* 2 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.635 (16.1) 210 (312) 290 (432)

TP14(IS-OS)T/NT-3 350358* 3 7/24.2 0.015/0.004 ( 0.38/0.10) 0.060 (1.52) 0.665 (16.9) 264 (393) 348 (518)

TP14(IS-OS)T/NT-4 030188* 4 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.725 (18.4) 322 (479) 414 (616)

TP14(IS-OS)T/NT-6 030189* 6 7/24.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.850 (21.6) 439 (653) 547 (814)

*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

16

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 17: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 16 AWG 1.3 mm2 / 600V

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_1

6AW

G_S

igna

l_20

16-1

1-22

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

17

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 18: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_1

6AW

G_S

igna

l_20

16-1

1-22

BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 16 AWG 1.3 mm2 / 600V

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

Jacket Thicknessin (mm)

Cable Diameter (nominal)in (mm)

Cable Weight (approximate)

Lbs/mft (Kg/km)

UNARMORED

TP16(OS)T/NT-1 030160 1 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.29 (7.4) 49 (72)

TP16(IS-OS)T/NT-2 030162 2 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.43 (11.0) 58 (86)

TP16(IS-OS)T/NT-3 036194 3 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.46 (11.7) 124 (184)

TP16(IS-OS)T/NT-4 030164 4 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.50 (12.8) 155 (231)

TP16(IS-OS)T/NT-5 036196 5 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.58 (14.8) 205 (306)

TP16(IS-OS)T/NT-6 030165 6 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.63 (16.1) 240 (356)

TP16(IS-OS)T/NT-7 036198 7 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.63 (16.1) 268 (398)

TP16(IS-OS)T/NT-8 030166 8 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.69 (17.4) 300 (446)

TP16(IS-OS)T/NT-9 036200 9 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.74 (18.8) 337 (502)

TP16(IS-OS)T/NT-10 036201 10 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.81 (20.4) 373 (555)

TP16(IS-OS)T/NT-11 036202 11 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.88 (22.2) 401 (597)

TP16(IS-OS)T/NT-12 036203 12 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.88 (22.2) 466 (693)

TP16(IS-OS)T/NT-13 036204 13 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 501 (746)

TP16(IS-OS)T/NT-14 036205 14 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 530 (788)

TP16(IS-OS)T/NT-15 030161 15 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.6) 566 (842)

TP16(IS-OS)T/NT-16 036207 16 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.6) 594 (884)

TP16(IS-OS)T/NT-17 036208 17 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 630 (938)

TP16(IS-OS)T/NT-18 036209 18 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 659 (981)

TP16(IS-OS)T/NT-19 036210 19 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 687 (1023)

TP16(IS-OS)T/NT-20 030163 20 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 724 (1077)

TP16(IS-OS)T/NT-21 036212 21 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 752 (1119)

TP16(IS-OS)T/NT-22 036213 22 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.12 (28.5) 789 (1174)

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

Jacket Thicknessin (mm)

Armored Cable Diameterin (mm)

Aluminum Armored Cable

WeightLbs/mft (Kg/km)

BronzeArmored Cable

WeightLbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

TP16(OS)T/NT-1 030160* 1 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.34 (8.7) 67 (100) 108 (161)

TP16(IS-OS)T/NT-2 030162* 2 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.48 (12.2) 84 (125) 143 (213)

TP16(IS-OS)T/NT-3 036194* 3 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.51 (13.0) 151 (225) 215 (320)

TP16(IS-OS)T/NT-4 030164* 4 7/19.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.55 (14.0) 185 (275) 253 (376)

TP16(IS-OS)T/NT-5 036196* 5 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.63 (16.0) 239 (356) 318 (473)

TP16(IS-OS)T/NT-6 030165* 6 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.68 (17.3) 277 (412) 362 (539)

TP16(IS-OS)T/NT-7 036198* 7 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.68 (17.3) 305 (454) 390 (580)

TP16(IS-OS)T/NT-8 030166* 8 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.74 (18.8) 340 (506) 433 (644)

TP16(IS-OS)T/NT-9 036200* 9 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.1) 380 (565) 479 (713)

TP16(IS-OS)T/NT-10 036201* 10 7/19.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.86 (21.9) 420 (625) 528 (786)

TP16(IS-OS)T/NT-11 036202* 11 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.93 (23.6) 452 (673) 569 (847)

TP16(IS-OS)T/NT-12 036203* 12 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.93 (23.6) 517 (769) 634 (943)

TP16(IS-OS)T/NT-13 036204* 13 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 554 (824) 677 (1007)

TP16(IS-OS)T/NT-14 036205* 14 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 583 (868) 706 (1051)

TP16(IS-OS)T/NT-15 030161* 15 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 622 (926) 751 (1117)

TP16(IS-OS)T/NT-16 036207* 16 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.02 (25.9) 650 (967) 779 (1159)

TP16(IS-OS)T/NT-17 036208* 17 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 689 (1025) 824 (1226)

TP16(IS-OS)T/NT-18 036209* 18 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 718 (1068) 853 (1269)

TP16(IS-OS)T/NT-19 036210* 19 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.07 (27.2) 746 (1110) 881 (1311)

TP16(IS-OS)T/NT-20 030163* 20 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.12 (28.5) 786 (1170) 928 (1381)

TP16(IS-OS)T/NT-21 036212* 21 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.12 (28.5) 814 (1211) 956 (1423)

TP16(IS-OS)T/NT-22 036213* 22 7/19.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.17 (29.7) 853 (1269) 1002 (1491)

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

18

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 19: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 18 AWG 0.82 mm2 / 600V

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_1

8AW

G_S

igna

l_20

16-1

1-28

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

19

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 20: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_1

8AW

G_S

igna

l_20

16-1

1-28

BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 18 AWG 0.82 mm2 / 600V

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

Jacket Thicknessin (mm)

Cable Diameter (nominal)in (mm)

Cable Weight (approximate)

Lbs/mft (Kg/km)

UNARMORED

TP18(OS)T/NT-1 029504 1 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.27 (6.8) 40 (59)

TP18(IS-OS)T/NT-2 030171 2 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.39 (10.0) 74 (111)

TP18(IS-OS)T/NT-3 029509 3 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.42 (10.6) 97 (145)

TP18(IS-OS)T/NT-4 030173 4 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.46 (11.6) 122 (181)

TP18(IS-OS)T/NT-5 029511 5 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.50 (12.7) 147 (218)

TP18(IS-OS)T/NT-6 036176 6 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.57 (14.6) 189 (282)

TP18(IS-OS)T/NT-7 029514 7 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.57 (14.6) 210 (313)

TP18(IS-OS)T/NT-8 030174 8 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.62 (15.7) 237 (352)

TP18(IS-OS)T/NT-9 036179 9 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.67 (16.9) 263 (392)

TP18(IS-OS)T/NT-10 029503 10 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.72 (18.4) 291 (433)

TP18(IS-OS)T/NT-11 036180 11 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.75 (19.0) 312 (465)

TP18(IS-OS)T/NT-12 030170 12 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.75 (19.0) 336 (500)

TP18(IS-OS)T/NT-13 036182 13 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.0) 361 (538)

TP18(IS-OS)T/NT-14 036183 14 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.0) 383 (570)

TP18(IS-OS)T/NT-15 036184 15 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.87 (22.1) 442 (659)

TP18(IS-OS)T/NT-16 036185 16 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.87 (22.1) 464 (690)

TP18(IS-OS)T/NT-17 036186 17 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 492 (732)

TP18(IS-OS)T/NT-18 036187 18 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 513 (763)

TP18(IS-OS)T/NT-19 036188 19 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.3) 534 (795)

TP18(IS-OS)T/NT-20 029507 20 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.96 (24.5) 562 (837)

TP18(IS-OS)T/NT-21 036190 21 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.96 (24.5) 584 (868)

TP18(IS-OS)T/NT-22 036191 22 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.01 (25.7) 613 (912)

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

Jacket Thicknessin (mm)

Armored Cable Diameterin (mm)

Aluminum Armored Cable

WeightLbs/mft (Kg/km)

BronzeArmored Cable

WeightLbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

TP18(OS)T/NT-1 029504* 1 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.32 (8.2) 57 (85) 95 (141)

TP18(IS-OS)T/NT-2 030171* 2 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.44 (11.2) 97 (144) 152 (226)

TP18(IS-OS)T/NT-3 029509* 3 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.47 (12.0) 122 (182) 180 (268)

TP18(IS-OS)T/NT-4 030173* 4 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.40 (10.2) 149 (222) 213 (317)

TP18(IS-OS)T/NT-5 029511* 5 7/15.2 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.55 (14.0) 177 (263) 245 (365)

TP18(IS-OS)T/NT-6 036176* 6 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.62 (15.8) 223 (332) 300 (446)

TP18(IS-OS)T/NT-7 029514* 7 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.62 (15.8) 244 (363) 321 (478)

TP18(IS-OS)T/NT-8 030174* 8 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.67 (17.0) 273 (406) 257 (382)

TP18(IS-OS)T/NT-9 036179* 9 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.72 (18.3) 302 (449) 393 (585)

TP18(IS-OS)T/NT-10 029503* 10 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.77 (19.6) 333 (496) 430 (640)

TP18(IS-OS)T/NT-11 036180* 11 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.80 (20.3) 356 (530) 456 (679)

TP18(IS-OS)T/NT-12 030170* 12 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.80 (20.3) 380 (565) 480 (714)

TP18(IS-OS)T/NT-13 036182* 13 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.4) 407 (606) 513 (763)

TP18(IS-OS)T/NT-14 036183* 14 7/15.2 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.4) 429 (638) 535 (796)

TP18(IS-OS)T/NT-15 036184* 15 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.4) 492 (732) 608 (905)

TP18(IS-OS)T/NT-16 036185* 16 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.92 (23.4) 514 (765) 630 (937)

TP18(IS-OS)T/NT-17 036186* 17 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 545 (811) 668 (994)

TP18(IS-OS)T/NT-18 036187* 18 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 566 (842) 689 (1025)

TP18(IS-OS)T/NT-19 036188* 19 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (24.7) 587 (873) 710 (1056)

TP18(IS-OS)T/NT-20 029507* 20 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.01 (25.7) 617 (918) 745 (1109)

TP18(IS-OS)T/NT-21 036190* 21 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.01 (25.7) 639 (951) 767 (1141)

TP18(IS-OS)T/NT-22 036191* 22 7/15.2 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.06 (26.9) 671 (998) 806 (1199)

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

20

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 21: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 20 AWG 0.52 mm2 / 300V

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_2

0AW

G_S

igna

l_20

16-1

1-28

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431B-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 99/60004(E3).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

21

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 22: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE T

/N_2

0AW

G_S

igna

l_20

16-1

1-28

BOSTMARINE Type T/N Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 20 AWG 0.52 mm2 / 300V

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

Jacket Thicknessin (mm)

Cable Diameter (nominal)in (mm)

Cable Weight (approximate)

Lbs/mft (Kg/km)

UNARMORED

TP20(OS)T/NT-1 030190 1 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.25 (6.3) 33 (49)

TP20(IS-OS)T/NT-2 030193 2 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.36 (9.1) 61 (91)

TP20(IS-OS)T/NT-3 030194 3 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.38 (9.7) 80 (119)

TP20(IS-OS)T/NT-4 030195 4 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.41 (10.5) 99 (147)

TP20(IS-OS)T/NT-5 036154 5 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.45 (11.5) 118 (175)

TP20(IS-OS)T/NT-6 036155 6 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.49 (12.5) 137 (204)

TP20(IS-OS)T/NT-7 036156 7 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.49 (12.5) 153 (228)

TP20(IS-OS)T/NT-8 036157 8 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.56 (14.3) 186 (277)

TP20(IS-OS)T/NT-9 036158 9 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.61 (15.4) 211 (314)

TP20(IS-OS)T/NT-10 029501 10 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.66 (16.7) 229 (341)

TP20(IS-OS)T/NT-11 036159 11 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.68 (17.2) 245 (365)

TP20(IS-OS)T/NT-12 030191 12 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.68 (17.2) 267 (397)

TP20(IS-OS)T/NT-13 036161 13 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.71 (18.1) 287 (427)

TP20(IS-OS)T/NT-14 036162 14 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.71 (18.1) 303 (450)

TP20(IS-OS)T/NT-15 036163 15 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.75 (19.1) 323 (481)

TP20(IS-OS)T/NT-16 036164 16 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.75 (19.1) 339 (504)

TP20(IS-OS)T/NT-17 036165 17 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.2) 360 (535)

TP20(IS-OS)T/NT-18 036166 18 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.2) 375 (559)

TP20(IS-OS)T/NT-19 036167 19 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.79 (20.2) 391 (582)

TP20(IS-OS)T/NT-20 036168 20 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.88 (22.2) 447 (665)

TP20(IS-OS)T/NT-21 036169 21 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.88 (22.2) 463 (689)

TP20(IS-OS)T/NT-22 036170 22 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 1.92 (23.3) 485 (722)

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

PVC/NylonInsulation Thickness

in (mm)

Jacket Thicknessin (mm)

Armored Cable Diameterin (mm)

Aluminum Armored Cable

WeightLbs/mft (Kg/km)

BronzeArmored Cable

WeightLbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

TP20(OS)T/NT-1 030190* 1 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.30 (7.6) 49 (73) 86 (128)

TP20(IS-OS)T/NT-2 030193* 2 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.41 (10.4) 83 (135) 135 (201)

TP20(IS-OS)T/NT-3 030194* 3 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.43 (10.9) 103 (153) 158 (235)

TP20(IS-OS)T/NT-4 030195* 4 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.46 (11.7) 124 (185) 182 (271)

TP20(IS-OS)T/NT-5 036154* 5 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.50 (12.7) 145 (216) 209 (311)

TP20(IS-OS)T/NT-6 036155* 6 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.54 (13.7) 167 (248) 236 (351)

TP20(IS-OS)T/NT-7 036156* 7 7/12.1 0.015/0.004 (0.38/0.10) 0.045 (1.14) 0.54 (13.7) 183 (272) 252 (375)

TP20(IS-OS)T/NT-8 036157* 8 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.61 (15.5) 220 (327) 298 (443)

TP20(IS-OS)T/NT-9 036158* 9 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.66 (15.4) 248 (369) 332 (494)

TP20(IS-OS)T/NT-10 029501* 10 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.71 (18.0) 269 (400) 360 (536)

TP20(IS-OS)T/NT-11 036159* 11 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.73 (18.5) 286 (426) 380 (565)

TP20(IS-OS)T/NT-12 030191* 12 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.73 (18.5) 308 (458) 402 (598)

TP20(IS-OS)T/NT-13 036161* 13 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.76 (19.3) 329 (490) 427 (635)

TP20(IS-OS)T/NT-14 036162* 14 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.76 (19.3) 345 (513) 443 (695)

TP20(IS-OS)T/NT-15 036163* 15 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.80 (20.3) 368 (548) 471 (701)

TP20(IS-OS)T/NT-16 036164* 16 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.80 (20.3) 384 (571) 487 (725)

TP20(IS-OS)T/NT-17 036165* 17 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.3) 407 (606) 515 (766)

TP20(IS-OS)T/NT-18 036166* 18 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.3) 422 (628) 530 (789)

TP20(IS-OS)T/NT-19 036167* 19 7/12.1 0.015/0.004 (0.38/0.10) 0.060 (1.52) 0.84 (21.3) 438 (652) 546 (812)

TP20(IS-OS)T/NT-20 036168* 20 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.93 (23.6) 499 (743) 620 (923)

TP20(IS-OS)T/NT-21 036169* 21 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.93 (23.6) 515 (766) 636 (946)

TP20(IS-OS)T/NT-22 036170* 22 7/12.1 0.015/0.004 (0.38/0.10) 0.080 (2.03) 0.97 (23.3) 539 (802) 665 (990)

22

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 23: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type X Control CableMulti-Conductor / Unarmored & Armored / 18, 16, and 14 AWG / 600V

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

A70

0_B

OST

MA

RIN

E_TY

PE X

_Con

trol

Cab

le_2

016-

11-2

8

Lloyd’sRegister

23

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 24: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A70

0_B

OST

MA

RIN

E_TY

PE X

_Con

trol

Cab

le_2

016-

11-1

7

A brand of the

BOSTMARINE Type X Control CableMulti-Conductor / Unarmored & Armored / 18, 16, and 14 AWG / 600V

TPC Cable Type

Part Number*Number of Conductors

Stranding Type

Insulation Thickness

in (mm)

JacketThickness

in (mm)

CableDiameter

(nom)in (mm)

Cable Weight (approx)Lbs/mft(Kg/km)

Armored Cable Diameter

(nom)Lbs/mft(Kg/km)

Aluminum Arm. Cable

Weight Lbs/mft(Kg/km)

Bronze Arm. Cable Weight

Lbs/mft(Kg/km)

18 AWG • 1.0 mm2

C18XT-2 036570* 2 7/15.2 .030 (0.76) .045 (1.14) 0.32 (8.0) 47 (70) 0.375 (9.5) 67 (100) 113 (168)

C18XT-3 036571* 3 7/15.2 .030 (0.76) .045 (1.14) 0.33 (8.4) 56 (83) 0.385 (9.8) 77 (115) 124 (185)

C18XT-4 036572* 4 7/15.2 .030 (0.76) .045 (1.14) 0.36 (9.1) 68 (101) 0.415 (10.5) 90 (134) 142 (211)

C18XT-7 036573* 7 7/15.2 .030 (0.76) .045 (1.14) 0.42 (10.8) 99 (147) 0.475 (12.1) 125 (186) 184 (274)

C18XT-10 036574* 10 7/15.2 .030 (0.76) .060 (1.52) 0.56 (14.4) 153 (228) 0.615 (15.6) 187 (278) 265 (394)

C18XT-16 036575* 16 7/15.2 .030 (0.76) .060 (1.52) 0.61 (15.5) 195 (290) 0.665 (16.9) 232 (345) 316 (470)

C18XT-20 036576* 20 7/15.2 .030 (0.76) .060 (1.52) 0.67 (17.0) 250 (372) 0.725 (18.4) 290 (432) 383 (570)

C18XT-24 036577* 24 7/15.2 .030 (0.76) .060 (1.52) 0.78 (19.8) 308 (458) 0.835 (21.2) 354 (527) 462 (687)

C18XT-30 036578* 30 7/15.2 .030 (0.76) .080 (2.03) 0.88 (22.4) 370 (551) 0.915 (23.2) 422 (628) 543 (808)

C18XT-37 036579* 37 7/15.2 .030 (0.76) .080 (2.03) 0.93 (23.6) 480 (714) 0.985 (25.0) 535 (796) 662 (985)

C18XT-44 036580* 44 7/15.2 .030 (0.76) .080 (2.03) 1.03 (26.2) 547 (814) 1.085 (27.6) 608 (905) 748 (1113)

C18XT-61 036581* 61 7/15.2 .030 (0.76) .080 (2.03) 1.10 (27.9) 696 (1036) 1.155 (29.3) 761 (1132) 910 (1354)

16 AWG • 1.3 mm2

C16XT-2 036582* 2 7/19.2 .030 (0.76) .045 (1.14) 0.34 (8.6) 57 (85) 0.395 (10.0) 78 (116) 127 (189)

C16XT-3 036583* 3 7/19.2 .030 (0.76) .045 (1.14) 0.36 (9.1) 71 (106) 0.415 (10.5) 93 (138) 145 (216)

C16XT-4 036584* 4 7/19.2 .030 (0.76) .045 (1.14) 0.39 (9.9) 87 (129) 0.445 (11.3) 111 (165) 167 (248)

C16XT-7 036585* 7 7/19.2 .030 (0.76) .045 (1.14) 0.46 (11.7) 129 (192) 0.515 (13.1) 157 (234) 222 (330)

C16XT-10 036053* 10 7/19.2 .030 (0.76) .060 (1.52) 0.61 (15.6) 197 (293) 0.665 (16.9) 234 (348) 318 (473)

C16XT-16 036586* 16 7/19.2 .030 (0.76) .060 (1.52) 0.67 (16.9) 255 (379) 0.725 (18.4) 295 (439) 388 (577)

C16XT-20 036587* 20 7/19.2 .030 (0.76) .060 (1.52) 0.73 (18.7) 328 (488) 0.785 (19.9) 372 (553) 472 (702)

C16XT-24 036588* 24 7/19.2 .030 (0.76) .080 (2.03) 0.90 (22.9) 444 (661) 0.955 (24.3) 497 (740) 620 (923)

C16XT-30 036589* 30 7/19.2 .030 (0.76) .080 (2.03) 0.95 (24.1) 529 (787) 1.005 (25.5) 585 (870) 715 (1064)

C16XT-37 036590* 37 7/19.2 .030 (0.76) .080 (2.03) 1.02 (25.9) 631 (939) 1.075 (27.3) 691 (1028) 830 (1235)

C16XT-44 036591* 44 7/19.2 .030 (0.76) .080 (2.03) 1.16 (29.3) 748 (1113) 1.215 (30.9) 816 (1214) 974 (1449)

C16XT-61 036592* 61 7/19.2 .030 (0.76) .080 (2.03) 1.27 (32.4) 980 (1458) 1.325 (33.7) 1054 (1568) 1227 (1825)

14 AWG • 2.1 mm2

C14XT-2 036593* 2 7/24.2 .030 (0.76) .045 (1.14) 0.37 (9.4) 72 (107) 0.425 (10.8) 95 (141) 148 (220)

C14XT-3 036594* 3 7/24.2 .030 (0.76) .045 (1.14) 0.39 (9.9) 92 (137) 0.445 (11.3) 116 (173) 172 (256)

C14XT-4 036595* 4 7/24.2 .030 (0.76) .045 (1.14) 0.42 (10.8) 114 (170) 0.475 (12.1) 140 (208) 199 (296)

C14XT-7 036057* 7 7/24.2 .030 (0.76) .045 (1.14) 0.51 (12.8) 173 (257) 0.565 (14.4) 204 (306) 275 (409)

C14XT-10 036596* 10 7/24.2 .030 (0.76) .060 (1.52) 0.68 (17.1) 261 (388) 0.735 (18.7) 302 (449) 396 (589)

C14XT-16 036058* 16 7/24.2 .030 (0.76) .060 (1.52) 0.73 (18.5) 342 (509) 0.785 (19.9) 386 (574) 486 (723)

C14XT-20 036597* 20 7/24.2 .030 (0.76) .060 (1.52) 0.81 (20.6) 444 (661) 0.865 (22.0) 492 (732) 603 (897)

C14XT-24 036059* 24 7/24.2 .030 (0.76) .080 (2.03) 0.99 (25.1) 593 (882) 1.045 (26.5) 651 (969) 786 (1170)

C14XT-30 036598* 30 7/24.2 .030 (0.76) .080 (2.03) 1.05 (26.7) 714 (1063) 1.105 (28.1) 776 (1155) 919 (1367)

C14XT-37 036599* 37 7/24.2 .030 (0.76) .080 (2.03) 1.13 (28.7) 856 (1274) 1.185 (30.1) 922 (1372) 1076 (1601)

C14XT-44 036600* 44 7/24.2 .030 (0.76) .080 (2.03) 1.27 (32.3) 1010 (1503) 1.325 (33.7) 1084 (1613) 1257 (1870)

C14XT-61 036601* 61 7/24.2 .030 (0.76) .080 (2.03) 1.40 (35.4) 1350 (2009) 1.455 (37.0) 1432 (2131) 1621 (2412)

*NOTE: For aluminum armored versions, add an A (ex. 036570A). For bronze armored versions, add a B (ex. 036570B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

24

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 25: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type X Power CableTwo Conductor / Unarmored & Armored / 14 AWG to 1000 MCM / 600V

A70

0_B

OST

MA

RIN

E_TY

PE X

_2C_

Pow

er_2

016-

11-2

1

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

25

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 26: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)Stranding Type

Insulation Thicknessin (mm)

JacketThickness

in (mm)

Cable Diameter(nominal)in (mm)

Cable Weight(approximate)

Lbs/mft (Kg/km)

UNARMORED

DXT-4 036012 14 (2.1) 7/24.2 0.030 (0.76) 0.045 (1.14) 0.380 (9.7) 81 (121)

DXT-6 036013 12 (3.3) 7/30.5 0.030 (0.76) 0.045 (1.14) 0.420 (10.7) 98 (146)

DXT-10 036050 10 (5.3) 7/38.5 0.030 (0.76) 0.045 (1.14) 0.470 (11.9) 138 (205)

DXT-16 036051 8 (8.4) 7/48.6 0.045 (1.14) 0.060 (1.52) 0.630 (16.0) 234 (348)

DXT-26 036542 6 (13.3) 7/61.2 0.045 (1.14) 0.060 (1.52) 0.705 (17.9) 280 (417)

DXT-41 036543 4 (21.1) 7/77.2 0.045 (1.14) 0.060 (1.52) 0.810 (20.6) 448 (667)

DXT-66 036544 2 (33.6) 7/97.4 0.045 (1.14) 0.080 (2.03) 0.970 (24.6) 682 (1015)

DXT-83 036545 1 (42.4) 19/66.4 0.055 (1.40) 0.080 (2.03) 1.090 (27.7) 835 (1242)

DXT-106 036546 1/0 (53.5) 19/74.5 0.055 (1.40) 0.080 (2.03) 1.180 (30.0) 915 (1362)

DXT-133 036547 2/0 (67.4) 19/83.7 0.055 (1.40) 0.080 (2.03) 1.270 (32.3) 1222 (1818)

DXT-168 036548 3/0 (85.0) 19/94.0 0.055 (1.40) 0.080 (2.03) 1.380 (35.1) 1491 (2219)

DXT-212 036549 4/0 (107.2) 19/105.5 0.055 (1.40) 0.080 (2.03) 1.490 (37.8) 1805 (2686)

DXT-250 036550 250 (127.0) 37/82.2 0.065 (1.65) 0.080 (2.03) 1.630 (41.4) 1945 (2894)

DXT-300 036551 300 (152.0) 37/90.0 0.065 (1.65) 0.110 (2.79) 1.810 (46.0) 2385 (3549)

DXT-350 036552 350 (177.0) 37/97.3 0.065 (1.65) 0.110 (2.79) 1.910 (48.5) 2735 (4070)

DXT-400 036553 400 (203.0) 37/104.0 0.065 (1.65) 0.110 (2.79) 2.005 (50.9) 3080 (4584)

DXT-500 036554 500 (253.0) 37/116.2 0.065 (1.65) 0.110 (2.79) 2.180 (55.4) 3755 (5588)

DXT-600 036555 600 (304.0) 61/99.2 0.080 (2.03) 0.110 (2.79) 2.405 (61.1) 4530 (6741)

DXT-750 036556 750 (380.0) 61/110.9 0.080 (2.03) 0.110 (2.79) 2.620 (66.5) 5550 (8259)

DXT-1000 036557 1000 (507.0) 61/128.0 0.080 (2.03) 0.110 (2.79) 2.995 (76.1) 7390 (10,997)

*NOTE: For aluminum armored versions, add an A (ex. 3036012A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)Stranding Type

Insulation Thickness

in (mm)

JacketThickness

in (mm)

Armored CableDiameterin (mm)

Aluminum Armor Cable Weight

Lbs/mft (Kg/km)

Bronze ArmorCable Weight

Lbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

DXT-4 036012* 14 (2.1) 7/24.2 0.030 (0.76) 0.045 (1.14) 0.435 (11.0) 104 (155) 159 (237)

DXT-6 036013* 12 (3.3) 7/30.5 0.030 (0.76) 0.045 (1.14) 0.475 (12.1) 124 (185) 183 (272)

DXT-10 036050* 10 (5.3) 7/38.5 0.030 (0.76) 0.045 (1.14) 0.525 (13.3) 167 (248) 233 (347)

DXT-16 036051* 8 (8.4) 7/48.6 0.045 (1.14) 0.060 (1.52) 0.685 (17.4) 272 (405) 359 (534)

DXT-26 036542* 6 (13.3) 7/61.2 0.045 (1.14) 0.060 (1.52) 0.760 (19.3) 322 (479) 419 (623)

DXT-41 036543* 4 (21.1) 7/77.2 0.045 (1.14) 0.060 (1.52) 0.865 (22.0) 496 (738) 607 (903)

DXT-66 036544* 2 (33.6) 7/97.4 0.045 (1.14) 0.080 (2.03) 1.025 (26.0) 739 (1100) 872 (1298)

DXT-83 036545* 1 (42.4) 19/66.4 0.055 (1.40) 0.080 (2.03) 1.145 (29.1) 899 (1338) 1047 (1558)

DXT-106 036546* 1/0 (53.5) 19/74.5 0.055 (1.40) 0.080 (2.03) 1.235 (31.4) 984 (1464) 1145 (1704)

DXT-133 036547* 2/0 (67.4) 19/83.7 0.055 (1.40) 0.080 (2.03) 1.325 (33.7) 1296 (1928) 1469 (2632)

DXT-168 036548* 3/0 (85.0) 19/94.0 0.055 (1.40) 0.080 (2.03) 1.435 (36.4) 1572 (2339) 1758 (2616)

DXT-212 036549* 4/0 (107.2) 19/105.5 0.055 (1.40) 0.080 (2.03) 1.545 (39.2) 1892 (2815) 2093 (3114)

DXT-250 036550* 250 (127.0) 37/82.2 0.065 (1.65) 0.080 (2.03) 1.685 (42.3) 2040 (3036) 2260 (3363)

DXT-300 036551* 300 (152.0) 37/90.0 0.065 (1.65) 0.110 (2.79) 1.865 (47.4) 2490 (3705) 2734 (4068)

DXT-350 036552* 350 (177.0) 37/97.3 0.065 (1.65) 0.110 (2.79) 1.965 (49.9) 2846 (4235) 3103 (4617)

DXT-400 036553* 400 (203.0) 37/104.0 0.065 (1.65) 0.110 (2.79) 2.060 (52.3) 3197 (4757) 3466 (5157)

DXT-500 036554* 500 (253.0) 37/116.2 0.065 (1.65) 0.110 (2.79) 2.235 (56.8) 3882 (5776) 4174 (6211)

DXT-600 036555* 600 (304.0) 61/99.2 0.080 (2.03) 0.110 (2.79) 2.460 (62.5) 4670 (6949) 4991 (7427)

DXT-750 036556* 750 (380.0) 61/110.9 0.080 (2.03) 0.110 (2.79) 2.675 (67.9) 5702 (8485) 6053 (9007)

DXT-1000 036557* 1000 (507.0) 61/128.0 0.080 (2.03) 0.140 (3.56) 3.055 (77.6) 7563 (11,254) 7964 (11,850)

A70

0_B

OST

MA

RIN

E_TY

PE X

_2C_

Pow

er_2

016-

11-2

1

A brand of the

BOSTMARINE Type X Power CableTwo Conductor/ Unarmored & Armored / 14 AWG to 1000 MCM / 600V

26

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 27: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type X Power CableThree Conductor / Unarmored & Armored / 14 AWG to 1000 MCM / 600V

A70

0_B

OST

MA

RIN

E_TY

PE X

_3C_

Pow

er_2

016-

11-3

0

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

27

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 28: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A70

0_B

OST

MA

RIN

E_TY

PE X

_3C_

Pow

er_2

016-

11-3

0

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)Stranding Type

Insulation Thicknessin (mm)

JacketThickness

in (mm)

Cable Diameter(nominal)in (mm)

Cable Weight(approximate)

Lbs/mft (Kg/km)

UNARMORED

TXT-4 030125 14 • 2.1 7/24.2 0.030 (0.76) 0.045 (1.14) 0.400 (10.2) 90 (134)

TXT-6 030113 12 • 3.3 7/30.5 0.030 (0.76) 0.045 (1.14) 0.440 (11.2) 120 (179)

TXT-10 036010 10 • 5.3 7/38.5 0.030 (0.76) 0.045 (1.14) 0.500 (12.7) 170 (253)

TXT-16 036009 8 • 8.4 7/48.6 0.045 (1.14) 0.060 (1.52) 0.670 (17.1) 280 (417)

TXT-26 036055 6 • 13.3 7/61.2 0.045 (1.14) 0.060 (1.52) 0.750 (19.1) 395 (588)

TXT-41 036008 4 • 21.1 7/77.2 0.045 (1.14) 0.080 (2.03) 0.900 (23.0) 570 (848)

TXT-66 036007 2 • 33.6 7/97.4 0.045 (1.14) 0.080 (2.03) 1.030 (26.2) 875 (1302)

TXT-83 030126 1 • 42.4 19/66.4 0.055 (1.40) 0.080 (2.03) 1.160 (29.5) 1090 (1622)

TXT-106 030127 1/0 • 53.5 19/74.5 0.055 (1.40) 0.080 (2.03) 1.255 (31.9) 1320 (1964)

TXT-133 030140 2/0 • 67.4 19/83.7 0.055 (1.40) 0.080 (2.03) 1.355 (34.4) 1615 (2403)

TXT-168 030141 3/0 • 85.0 19/94.0 0.055 (1.40) 0.080 (2.03) 1.470 (37.3) 1980 (2947)

TXT-212 030142 4/0 • 107.2 19/105.5 0.055 (1.40) 0.080 (2.03) 1.595 (40.5) 2435 (3624)

TXT-250 030158 250 • 127.0 37/82.2 0.065 (1.65) 0.110 (2.79) 1.810 (46.0) 2965 (4412)

TXT-300 036559 300 • 152.0 37/90.0 0.065 (1.65) 0.110 (2.79) 1.930 (49.0) 3485 (5186)

TXT-350 030124 350 • 177.0 37/97.3 0.065 (1.65) 0.110 (2.79) 2.040 (51.8) 4005 (5960)

TXT-400 030200 400 • 203.0 37/104.0 0.065 (1.65) 0.110 (2.79) 2.140 (54.4) 4525 (6734)

TXT-500 030647 500 • 253.0 37/116.2 0.065 (1.65) 0.110 (2.79) 2.330 (59.2) 5545 (8252)

TXT-750 036561 750 • 380.0 61/110.9 0.080 (2.03) 0.140 (3.56) 2.865 (72.8) 8420 (12,530)

TXT-1000 036562 1000 • 507.0 61/128.0 0.080 (2.03) 0.140 (3.56) 3.200 (81.3) 11,000 (16,370)

*NOTE: For aluminum armored versions, add an A (ex. 3036012A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)Stranding Type

Insulation Thickness

in (mm)

JacketThickness

in (mm)

Armored CableDiameterin (mm)

Aluminum Armor Cable Weight

Lbs/mft (Kg/km)

Bronze ArmorCable Weight

Lbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

TXT-4 030125* 14 • 2.1 7/24.2 0.030 (0.76) 0.045 (1.14) 0.440 (11.2) 115 (171) 171 (254)

TXT-6 030113* 12 • 3.3 7/30.5 0.030 (0.76) 0.045 (1.14) 0.490 (12.5) 147 (219) 209 (311)

TXT-10 036010* 10 • 5.3 7/38.5 0.030 (0.76) 0.045 (1.14) 0.550 (14.0) 200 (298) 270 (402)

TXT-16 036009* 8 • 8.4 7/48.6 0.045 (1.14) 0.060 (1.52) 0.720 (18.3) 320 (476) 413 (615)

TXT-26 036055* 6 • 13.3 7/61.2 0.045 (1.14) 0.060 (1.52) 0.880 (22.4) 440 (655) 543 (808)

TXT-41 036008* 4 • 21.1 7/77.2 0.045 (1.14) 0.080 (2.03) 0.950 (24.2) 623 (927) 746 (1110)

TXT-66 036007* 2 • 33.6 7/97.4 0.045 (1.14) 0.080 (2.03) 1.080 (27.6) 936 (1393) 1076 (1601)

TXT-83 030126* 1 • 42.4 19/66.4 0.055 (1.40) 0.080 (2.03) 1.210 (30.8) 1158 (1732) 1316 (1958)

TXT-106 030127* 1/0 • 53.5 19/74.5 0.055 (1.40) 0.080 (2.03) 1.310 (33.3) 1394 (2074) 1564 (2327)

TXT-133 030140* 2/0 • 67.4 19/83.7 0.055 (1.40) 0.080 (2.03) 1.410 (35.8) 1694 (2521) 1878 (2794)

TXT-168 030141* 3/0 • 85.0 19/94.0 0.055 (1.40) 0.080 (2.03) 1.520 (38.6) 2066 (3074) 2265 (3370)

TXT-212 030142* 4/0 • 107.2 19/105.5 0.055 (1.40) 0.080 (2.03) 1.650 (41.9) 2528 (3762) 2743 (4082)

TXT-250 030158* 250 • 127.0 37/82.2 0.065 (1.65) 0.110 (2.79) 1.860 (47.3) 3070 (4568) 3314 (4931)

TXT-300 036559* 300 • 152.0 37/90.0 0.065 (1.65) 0.110 (2.79) 1.980 (50.3) 3597 (5352) 3857 (5739)

TXT-350 030124* 350 • 177.0 37/97.3 0.065 (1.65) 0.110 (2.79) 2.090 (53.1) 4124 (6137) 4398 (6544)

TXT-400 030200* 400 • 203.0 37/104.0 0.065 (1.65) 0.110 (2.79) 2.190 (55.7) 4649 (6918) 4937 (7346)

TXT-500 030647* 500 • 253.0 37/116.2 0.065 (1.65) 0.110 (2.79) 2.380 (60.5) 5680 (8452) 5993 (8918)

TXT-750 036561* 750 • 380.0 61/110.9 0.080 (2.03) 0.140 (3.56) 2.920 (74.2) 8586 (12,776) 8969 (13,346)

TXT-1000 036562* 1000 • 507.0 61/128.0 0.080 (2.03) 0.140 (3.56) 3.250 (82.6) 11,185 (16,643) 11,613 (17,280)

A brand of the

BOSTMARINE Type X Power CableThree Conductor/ Unarmored & Armored / 14 AWG to 1000 MCM / 600V

28

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 29: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type X Power CableFour Conductor / Unarmored & Armored / 14 AWG to 500 MCM / 600V

A70

0_B

OST

MA

RIN

E_TY

PE X

_4C_

Pow

er_2

016-

11-1

7

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

29

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 30: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE X

_4C_

Pow

er_2

016-

11-1

7

BOSTMARINE Type X Power CableFour Conductor/ Unarmored & Armored / 14 AWG to 500 MCM / 600V

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)Stranding Type

Insulation Thicknessin (mm)

JacketThickness

in (mm)

Cable Diameter(nominal)in (mm)

Cable Weight(approximate)

Lbs/mft (Kg/km)

UNARMORED

FXT-4 036563 14 (2.1) 7/24.2 .030 (0.76) .045 (1.14) 0.440 (11.2) 120 (179)

FXT-6 036564 12 (3.3) 7/30.5 .030 (0.76) .045 (1.14) 0.485 (12.3) 164 (244)

FXT-10 036052 10 (5.3) 7/38.5 .030 (0.76) .060 (1.52) 0.575 (14.6) 241 (359)

FXT-16 036565 8 (8.4) 7/48.6 .045 (1.14) .060 (1.52) 0.730 (18.5) 382 (568)

FXT-26 036566 6 (13.3) 7/61.2 .045 (1.14) .060 (1.52) 0.830 (21.1) 542 (806)

FXT-41 036015 4 (21.1) 7/77.2 .045 (1.14) .080 (2.03) 0.990 (25.1) 824 (1226)

FXT-66 036011 2 (33.6) 7/97.4 .045 (1.14) .080 (2.03) 1.140 (29.0) 1205 (1793)

FXT-83 030143 1 (42.4) 19/66.4 .055 (1.40) .080 (2.03) 1.290 (32.8) 1500 (2232)

FXT-106 030144 1/0 (53.5) 19/74.5 .055 (1.40) .080 (2.03) 1.390 (35.3) 1782 (2652)

FXT-133 030145 2/0 (67.4) 19/83.7 .055 (1.40) .080 (2.03) 1.500 (38.1) 2220 (3303)

FXT-168 030146 3/0 (85.0) 19/94.0 .055 (1.40) .080 (2.03) 1.625 (41.3) 2706 (4027)

FXT-212 030147 4/0 (107.2) 19/105.5 .055 (1.40) .110 (2.79) 1.830 (46.5) 3444 (5125)

FXT-250 030183 250 (127.0) 37/82.2 .065 (1.65) .110 (2.79) 2.000 (50.8) 4002 (5955)

FXT-300 036568 300 (152.0) 37/90.0 .065 (1.65) .110 (2.79) 2.130 (54.1) 4680 (6964)

FXT-350 030389 350 (177.0) 37/97.3 .065 (1.65) .110 (2.79) 2.260 (57.4) 5464 (8130)

FXT-400 036569 400 (203.0) 37104.0 .065 (1.65) .110 (2.79) 2.370 (60.2) 6140 (9136)

FXT-500 030647 500 (253.0) 37/116.2 .065 (1.65) .110 (2.79) 2.580 (65.5) 7560 (11,250)

*NOTE: For aluminum armored versions, add an A (ex. 3036563A). For bronze armored versions, add a B (ex. 030103B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

TPC Cable TypePart

Number

Conductor Size AWG/MCM

(mm2)Stranding Type

Insulation Thickness

in (mm)

JacketThickness

in (mm)

Armored CableDiameterin (mm)

Aluminum Armor Cable Weight

Lbs/mft (Kg/km)

Bronze ArmorCable Weight

Lbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

FXT-4 036563* 14 (2.1) 7/24.2 .030 (0.76) .045 (1.14) 0.495 (12.6) 147 (219) 209 (311)

FXT-6 036564* 12 (3.3) 7/30.5 .030 (0.76) .045 (1.14) 0.540 (13.7) 193 (287) 262 (390)

FXT-10 036052* 10 (5.3) 7/38.5 .030 (0.76) .060 (1.52) 0.630 (16.0) 276 (411) 356 (530)

FXT-16 036565* 8 (8.4) 7/48.6 .045 (1.14) .060 (1.52) 0.785 (19.9) 426 (634) 526 (783)

FXT-26 036566* 6 (13.3) 7/61.2 .045 (1.14) .060 (1.52) 0.885 (22.5) 591 (879) 705 (1049)

FXT-41 036015* 4 (21.1) 7/77.2 .045 (1.14) .080 (2.03) 1.045 (26.5) 882 (1312) 1017 (1513)

FXT-66 036011* 2 (33.6) 7/97.4 .045 (1.14) .080 (2.03) 1.195 (30.4) 1272 (1893) 1427 (2123)

FXT-83 030143* 1 (42.4) 19/66.4 .055 (1.40) .080 (2.03) 1.345 (34.2) 1576 (2345) 1750 (2604)

FXT-106 030144* 1/0 (53.5) 19/74.5 .055 (1.40) .080 (2.03) 1.445 (36.7) 1863 (2772) 2051 (3052)

FXT-133 030145* 2/0 (67.4) 19/83.7 .055 (1.40) .080 (2.03) 1.555 (39.5) 2308 (3434) 2510 (3735)

FXT-168 030146* 3/0 (85.0) 19/94.0 .055 (1.40) .080 (2.03) 1.680 (42.7) 2801 (4168) 3020 (4494)

FXT-212 030147* 4/0 (107.2) 19/105.5 .055 (1.40) .110 (2.79) 1.885 (47.9) 3551 (5284) 3797 (5650)

FXT-250 030183* 250 (127.0) 37/82.2 .065 (1.65) .110 (2.79) 2.055 (52.2) 4118 (6128) 4387 (6528)

FXT-300 036568* 300 (152.0) 37/90.0 .065 (1.65) .110 (2.79) 2.185 (55.5) 4804 (6128) 5090 (7574)

FXT-350 030389* 350 (177.0) 37/97.3 .065 (1.65) .110 (2.79) 2.315 (58.8) 5595 (8325) 5899 (8778)

FXT-400 036569* 400 (203.0) 37104.0 .065 (1.65) .110 (2.79) 2.425 (61.6) 6278 (9342) 6595 (9813)

FXT-500 030647* 500 (253.0) 37/116.2 .065 (1.65) .110 (2.79) 2.635 (66.9) 7710 (11,472) 8055 (11,986)

30

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 31: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 16 AWG 1.31 mm2 / 600V

A70

0_B

OST

MA

RIN

E_TY

PE X

_16A

WG

_Sig

nal_

2016

-11-

28

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

31

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 32: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE X

_16A

WG

_Sig

nal_

2016

-11-

28

BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 16 AWG 1.31 mm2 / 600V

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

Insulation Thicknessin (mm)

Jacket Thicknessin (mm)

Cable Diameter (nominal)in (mm)

Cable Weight (approximate)

Lbs/mft (Kg/km)

UNARMORED

TP16(IS)XT-1 036646 1 7/19.2 0.025 (0.64) 0.045 (1.14) 0.32 (8.1) 56 (83)

TP16(IS-OS)XT-2 036647 2 7/19.2 0.025 (0.64) 0.045 (1.14) 0.50 (12.7) 104 (155)

TP16(IS-OS)XT-3 036648 3 7/19.2 0.025 (0.64) 0.060 (1.52) 0.56 (14.2) 153 (228)

TP16(IS-OS)XT-4 036649 4 7/19.2 0.025 (0.64) 0.060 (1.52) 0.61 (15.5) 190 (283)

TP16(IS-OS)XT-5 036650 5 7/19.2 0.025 (0.64) 0.060 (1.52) 0.67 (17.0) 227 (338)

TP16(IS-OS)XT-6 036651 6 7/19.2 0.025 (0.64) 0.060 (1.52) 0.73 (18.5) 265 (394)

TP16(IS-OS)XT-7 036652 7 7/19.2 0.025 (0.64) 0.060 (1.52) 0.73 (18.5) 295 (439)

TP16(IS-OS)XT-8 036653 8 7/19.2 0.025 (0.64) 0.060 (1.52) 0.79 (20.1) 332 (494)

TP16(IS-OS)XT-9 036654 9 7/19.2 0.025 (0.64) 0.080 (2.03) 0.89 (22.6) 370 (551)

TP16(IS-OS)XT-10 036655 10 7/19.2 0.025 (0.64) 0.080 (2.03) 0.97 (24.6) 449 (668)

TP16(IS-OS)XT-11 036656 11 7/19.2 0.025 (0.64) 0.080 (2.03) 0.99 (25.1) 487 (724)

TP16(IS-OS)XT-12 036657 12 7/19.2 0.025 (0.64) 0.080 (2.03) 0.99 (25.1) 516 (768)

TP16(IS-OS)XT-13 036658 13 7/19.2 0.025 (0.64) 0.080 (2.03) 1.04 (26.4) 555 (826)

TP16(IS-OS)XT-14 036659 14 7/19.2 0.025 (0.64) 0.080 (2.03) 1.04 (26.4) 585 (870)

TP16(IS-OS)XT-15 036660 15 7/19.2 0.025 (0.64) 0.080 (2.03) 1.10 (27.9) 621 (924)

TP16(IS-OS)XT-16 036661 16 7/19.2 0.025 (0.64) 0.080 (2.03) 1.10 (27.9) 654 (974)

TP16(IS-OS)XT-17 036662 17 7/19.2 0.025 (0.64) 0.080 (2.03) 1.15 (29.2) 694 (1033)

TP16(IS-OS)XT-18 036663 18 7/19.2 0.025 (0.64) 0.080 (2.03) 1.15 (29.2) 724 (1078)

TP16(IS-OS)XT-19 036664 19 7/19.2 0.025 (0.64) 0.080 (2.03) 1.15 (29.2) 754 (1122)

TP16(IS-OS)XT-20 036665 20 7/19.2 0.025 (0.64) 0.080 (2.03) 1.21 (30.7) 790 (1176)

TP16(IS-OS)XT-21 036666 21 7/19.2 0.025 (0.64) 0.080 (2.03) 1.21 (30.7) 824 (1226)

TP16(IS-OS)XT-22 036667 22 7/19.2 0.025 (0.64) 0.080 (2.03) 1.28 (32.5) 865 (1287)

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

Insulation Thicknessin (mm)

Jacket Thicknessin (mm)

Armored Cable Diameterin (mm)

Aluminum Armored Cable

WeightLbs/mft (Kg/km)

BronzeArmored Cable

WeightLbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

TP16(IS)XT-1 036646* 1 7/19.2 0.025 (0.64) 0.045 (1.14) 0.375 (9.5) 76 (113) 122 (182)

TP16(IS-OS)XT-2 036647* 2 7/19.2 0.025 (0.64) 0.045 (1.14) 0.555 (14.1) 134 (199) 204 (304)

TP16(IS-OS)XT-3 036648* 3 7/19.2 0.025 (0.64) 0.060 (1.52) 0.615 (15.6) 187 (278) 265 (394)

TP16(IS-OS)XT-4 036649 4 7/19.2 0.025 (0.64) 0.060 (1.52) 0.665 (16.9) 227 (338) 311 (463)

TP16(IS-OS)XT-5 036650* 5 7/19.2 0.025 (0.64) 0.060 (1.52) 0.725 (18.4) 267 (397) 360 (534)

TP16(IS-OS)XT-6 036651* 6 7/19.2 0.025 (0.64) 0.060 (1.52) 0.785 (19.9) 309 (460) 409 (609)

TP16(IS-OS)XT-7 036652* 7 7/19.2 0.025 (0.64) 0.060 (1.52) 0.785 (19.9) 368 (548) 439 (653)

TP16(IS-OS)XT-8 036653* 8 7/19.2 0.025 (0.64) 0.060 (1.52) 0.845 (21.4) 379 (564) 487 (725)

TP16(IS-OS)XT-9 036654* 9 7/19.2 0.025 (0.64) 0.080 (2.03) 0.945 (24.0) 423 (629) 544 (809)

TP16(IS-OS)XT-10 036655* 10 7/19.2 0.025 (0.64) 0.080 (2.03) 1.025 (26.0) 506 (753) 639 (951)

TP16(IS-OS)XT-11 036656* 11 7/19.2 0.025 (0.64) 0.080 (2.03) 1.045 (26.5) 545 (811) 680 (1012)

TP16(IS-OS)XT-12 036657* 12 7/19.2 0.025 (0.64) 0.080 (2.03) 1.045 (26.5) 574 (854) 709 (1055)

TP16(IS-OS)XT-13 036658* 13 7/19.2 0.025 (0.64) 0.080 (2.03) 1.095 (27.8) 616 (917) 758 (1128)

TP16(IS-OS)XT-14 036659* 14 7/19.2 0.025 (0.64) 0.080 (2.03) 1.095 (27.8) 646 (961) 788 (1173)

TP16(IS-OS)XT-15 036660* 15 7/19.2 0.025 (0.64) 0.080 (2.03) 1.155 (29.3) 686 (1021) 835 (1242)

TP16(IS-OS)XT-16 036661* 16 7/19.2 0.025 (0.64) 0.080 (2.03) 1.155 (29.3) 719 (1070) 868 (1292)

TP16(IS-OS)XT-17 036662* 17 7/19.2 0.025 (0.64) 0.080 (2.03) 1.205 (24.2) 762 (1134) 918 (1366)

TP16(IS-OS)XT-18 036663* 18 7/19.2 0.025 (0.64) 0.080 (2.03) 1.205 (24.2) 792 (1178) 948 (1411)

TP16(IS-OS)XT-19 036664* 19 7/19.2 0.025 (0.64) 0.080 (2.03) 1.205 (24.2) 822 (1123) 978 (1455)

TP16(IS-OS)XT-20 036665* 20 7/19.2 0.025 (0.64) 0.080 (2.03) 1.265 (32.1) 861 (1281) 1025 (1525)

TP16(IS-OS)XT-21 036666* 21 7/19.2 0.025 (0.64) 0.080 (2.03) 1.265 (32.1) 895 (1332) 1059 (1576)

TP16(IS-OS)XT-22 036667* 22 7/19.2 0.025 (0.64) 0.080 (2.03) 1.335 (33.9) 940 (1399) 1113 (1656)

*NOTE: For aluminum armored versions, add an A (ex. 036646A). For bronze armored versions, add a B (ex. 036646B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

32

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 33: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 18 AWG 0.82 mm2 / 600V

A70

0_B

OST

MA

RIN

E_TY

PE X

_18A

WG

_Sig

nal_

2016

-11-

29

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

33

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 34: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE X

_18A

WG

_Sig

nal_

2016

-11-

29

BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 18 AWG 0.82 mm2 / 600V

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

Insulation Thicknessin (mm)

Jacket Thicknessin (mm)

Cable Diameter (nominal)in (mm)

Cable Weight (approximate)

Lbs/mft (Kg/km)

UNARMORED

TP18(IS)XT-1 036624 1 7/15.2 0.025 (0.64) 0.045 (1.14) 0.30 (7.6) 46 (68)

TP18(IS-OS)XT-2 036625 2 7/15.2 0.025 (0.64) 0.045 (1.14) 0.45 (11.4) 85 (126)

TP18(IS-OS)XT-3 036626 3 7/15.2 0.025 (0.64) 0.045 (1.14) 0.48 (12.2) 109 (162)

TP18(IS-OS)XT-4 036627 4 7/15.2 0.025 (0.64) 0.060 (1.52) 0.59 (15.0) 153 (228)

TP18(IS-OS)XT-5 036628 5 7/15.2 0.025 (0.64) 0.060 (1.52) 0.61 (15.5) 182 (271)

TP18(IS-OS)XT-6 036629 6 7/15.2 0.025 (0.64) 0.060 (1.52) 0.66 (16.8) 211 (314)

TP18(IS-OS)XT-7 036630 7 7/15.2 0.025 (0.64) 0.060 (1.52) 0.66 (16.8) 232 (346)

TP18(IS-OS)XT-8 036631 8 7/15.2 0.025 (0.64) 0.060 (1.52) 0.72 (18.3) 262 (390)

TP18(IS-OS)XT-9 036632 9 7/15.2 0.025 (0.64) 0.060 (1.52) 0.78 (19.8) 290 (432)

TP18(IS-OS)XT-10 036633 10 7/15.2 0.025 (0.64) 0.080 (2.03) 0.89 (22.6) 359 (534)

TP18(IS-OS)XT-11 036634 11 7/15.2 0.025 (0.64) 0.080 (2.03) 0.91 (23.1) 346 (516)

TP18(IS-OS)XT-12 036635 12 7/15.2 0.025 (0.64) 0.080 (2.03) 0.91 (23.1) 368 (548)

TP18(IS-OS)XT-13 036636 13 7/15.2 0.025 (0.64) 0.080 (2.03) 0.96 (24.4) 438 (652)

TP18(IS-OS)XT-14 036637 14 7/15.2 0.025 (0.64) 0.080 (2.03) 0.96 (24.4) 459 (684)

TP18(IS-OS)XT-15 036638 15 7/15.2 0.025 (0.64) 0.080 (2.03) 1.01 (25.7) 490 (729)

TP18(IS-OS)XT-16 036639 16 7/15.2 0.025 (0.64) 0.080 (2.03) 1.01 (25.7) 512 (762)

TP18(IS-OS)XT-17 036640 17 7/15.2 0.025 (0.64) 0.080 (2.03) 1.06 (26.9) 543 (808)

TP18(IS-OS)XT-18 036641 18 7/15.2 0.025 (0.64) 0.080 (2.03) 1.06 (26.9) 565 (840)

TP18(IS-OS)XT-19 036642 19 7/15.2 0.025 (0.64) 0.080 (2.03) 1.06 (26.9) 586 (872)

TP18(IS-OS)XT-20 036643 20 7/15.2 0.025 (0.64) 0.080 (2.03) 1.11 (28.2) 619 (921)

TP18(IS-OS)XT-21 036644 21 7/15.2 0.025 (0.64) 0.080 (2.03) 1.11 (28.2) 639 (951)

TP18(IS-OS)XT-22 036645 22 7/15.2 0.025 (0.64) 0.080 (2.03) 1.16 (29.5) 671 (998)

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

Insulation Thicknessin (mm)

Jacket Thicknessin (mm)

Armored Cable Diameterin (mm)

Aluminum Armored Cable

WeightLbs/mft (Kg/km)

BronzeArmored Cable

WeightLbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

TP18(IS)XT-1 036624* 1 7/15.2 0.025 (0.64) 0.045 (1.14) 0.355 (9.0) 65 (97) 108 (161) 122 (182)

TP18(IS-OS)XT-2 036625* 2 7/15.2 0.025 (0.64) 0.045 (1.14) 0.505 (12.8) 112 (167) 176 (262) 204 (304)

TP18(IS-OS)XT-3 036626* 3 7/15.2 0.025 (0.64) 0.045 (1.14) 0.535 (13.6) 138 (205) 206 (307) 265 (394)

TP18(IS-OS)XT-4 036627* 4 7/15.2 0.025 (0.64) 0.060 (1.52) 0.645 (16.4) 188 (280) 271 (403) 311 (463)

TP18(IS-OS)XT-5 036628* 5 7/15.2 0.025 (0.64) 0.060 (1.52) 0.665 (16.9) 219 (326) 303 (451) 360 (534)

TP18(IS-OS)XT-6 036629* 6 7/15.2 0.025 (0.64) 0.060 (1.52) 0.715 (18.2) 251 (373) 342 (509) 409 (609)

TP18(IS-OS)XT-7 036630* 7 7/15.2 0.025 (0.64) 0.060 (1.52) 0.715 (18.2) 272 (405) 363 (540) 439 (653)

TP18(IS-OS)XT-8 036631* 8 7/15.2 0.025 (0.64) 0.060 (1.52) 0.775 (19.7) 305 (454) 404 (601) 487 (725)

TP18(IS-OS)XT-9 036632* 9 7/15.2 0.025 (0.64) 0.060 (1.52) 0.835 (21.2) 336 (500) 444 (661) 544 (809)

TP18(IS-OS)XT-10 036633* 10 7/15.2 0.025 (0.64) 0.080 (2.03) 0.925 (23.5) 364 (542) 478 (711) 639 (951)

TP18(IS-OS)XT-11 036634* 11 7/15.2 0.025 (0.64) 0.080 (2.03) 0.965 (24.5) 393 (585) 512 (762) 680 (1012)

TP18(IS-OS)XT-12 036635* 12 7/15.2 0.025 (0.64) 0.080 (2.03) 0.965 (24.5) 422 (628) 546 (812) 709 (1055)

TP18(IS-OS)XT-13 036636* 13 7/15.2 0.025 (0.64) 0.080 (2.03) 1.015 (25.8) 495 (737) 626 (931) 758 (1128)

TP18(IS-OS)XT-14 036637* 14 7/15.2 0.025 (0.64) 0.080 (2.03) 1.015 (25.8) 516 (768) 647 (963) 788 (1173)

TP18(IS-OS)XT-15 036638* 15 7/15.2 0.025 (0.64) 0.080 (2.03) 1.065 (27.1) 550 (818) 687 (1022) 835 (1242)

TP18(IS-OS)XT-16 036639* 16 7/15.2 0.025 (0.64) 0.080 (2.03) 1.065 (27.1) 572 (851) 709 (1055) 868 (1292)

TP18(IS-OS)XT-17 036640* 17 7/15.2 0.025 (0.64) 0.080 (2.03) 1.115 (28.3) 605 (900) 750 (1116) 918 (1366)

TP18(IS-OS)XT-18 036641* 18 7/15.2 0.025 (0.64) 0.080 (2.03) 1.115 (28.3) 627 (933) 772 (1149) 948 (1411)

TP18(IS-OS)XT-19 036642* 19 7/15.2 0.025 (0.64) 0.080 (2.03) 1.115 (28.3) 648 (964) 793 (1180) 978 (1455)

TP18(IS-OS)XT-20 036643* 20 7/15.2 0.025 (0.64) 0.080 (2.03) 1.165 (29.6) 684 (1018) 835 (1242) 1025 (1525)

TP18(IS-OS)XT-21 036644* 21 7/15.2 0.025 (0.64) 0.080 (2.03) 1.165 (29.6) 704 (1048) 855 (1272) 1059 (1576)

TP18(IS-OS)XT-22 036645* 22 7/15.2 0.025 (0.64) 0.080 (2.03) 1.215 (30.9) 739 (1100) 897 (1335) 1113 (1656)

*NOTE: For aluminum armored versions, add an A (ex. 036624A). For bronze armored versions, add a B (ex. 036624B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

34

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 35: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 20 AWG 0.52 mm2 / 300V

A70

0_B

OST

MA

RIN

E_TY

PE X

_20A

WG

_Sig

nal_

2016

-11-

30

Design Parameters

CONDUCTORS: Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on reverse.

INSULATION: BOSTMARINE Type T/N polyvinyl chloride/nylon meeting specification IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015). Thickness as shown in tables on the reverse. Insulated conductors are rated VW1.

PAIR SHIELD: Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over the twisted pair, covered with a polyester tape.

JACKET: Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309(2013), and CSA 22.2 No.245 (2015).

Specifications and Ratings

- Meets all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), CSA 22.2 No. 245 (2015), and the Flame Test in IEC 60332-3, Category A.

- ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 (2013), and CSA 22.2 No. 245 (2015).

- American Bureau of Shipping Type Approval Certificate No. 03-HS388431A-5-PDA.

- Lloyds Registry of Shipping Type Approval Certificate No. 96/60034(E5).

- Transport Canada Approved cables are available.

Applications

BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

These cables meet all test requirements of IEEE 45.8 (2016), IEEE 1580 (2010), UL 1309 and the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized testing laboratory, per IEEE 45, IEEE-1580 and UL 1309 for 600 volts. Type T/N cables are Type Approved by ABS and LRS.

Aluminum and bronze armored versions are available.

Optional outer PVC sheath available upon request.

Features

- IEEE STANDARD 45.8 (2016)

- IEEE STANDARD 1580 (2010)

- UL 1309 (2013)

- CSA 22.2 No. 245 (2015)

Lloyd’sRegister

35

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas

Page 36: BOSTMARINE Product Catalog - Prysmian Group · Applications BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables

A brand of the

A70

0_B

OST

MA

RIN

E_TY

PE X

_20A

WG

_Sig

nal_

2016

-11-

30

BOSTMARINE Type X Signal CableIndividual & Overall Shielded Twisted Pair / Unarmored & Armored / 20 AWG 0.52 mm2 / 300V

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

Insulation Thicknessin (mm)

Jacket Thicknessin (mm)

Cable Diameter (nominal)in (mm)

Cable Weight (approximate)

Lbs/mft (Kg/km)

UNARMORED

TP20(IS)XT-1 036602 1 7/12.1 0.025 (0.64) 0.045 (1.14) 0.28 (7.1) 36 (54)

TP20(IS-OS)XT-2 036603 2 7/12.1 0.025 (0.64) 0.045 (1.14) 0.41 (10.4) 64 (95)

TP20(IS-OS)XT-3 036604 3 7/12.1 0.025 (0.64) 0.045 (1.14) 0.43 (10.9) 80 (119)

TP20(IS-OS)XT-4 036605 4 7/12.1 0.025 (0.64) 0.045 (1.14) 0.48 (12.2) 97 (144)

TP20(IS-OS)XT-5 036606 5 7/12.1 0.025 (0.64) 0.060 (1.52) 0.55 (14.0) 132 (196)

TP20(IS-OS)XT-6 036607 6 7/12.1 0.025 (0.64) 0.060 (1.52) 0.60 (15.2) 152 (226)

TP20(IS-OS)XT-7 036608 7 7/12.1 0.025 (0.64) 0.060 (1.52) 0.60 (15.2) 164 (244)

TP20(IS-OS)XT-8 036609 8 7/12.1 0.025 (0.64) 0.060 (1.52) 0.65 (16.5) 185 (275)

TP20(IS-OS)XT-9 036610 9 7/12.1 0.025 (0.64) 0.060 (1.52) 0.69 (17.5) 204 (303)

TP20(IS-OS)XT-10 036611 10 7/12.1 0.025 (0.64) 0.060 (1.52) 0.75 (19.1) 226 (336)

TP20(IS-OS)XT-11 036612 11 7/12.1 0.025 (0.64) 0.060 (1.52) 0.78 (19.8) 242 (360)

TP20(IS-OS)XT-12 036613 12 7/12.1 0.025 (0.64) 0.060 (1.52) 0.78 (19.8) 256 (381)

TP20(IS-OS)XT-13 036614 13 7/12.1 0.025 (0.64) 0.060 (1.52) 0.82 (20.8) 275 (409)

TP20(IS-OS)XT-14 036615 14 7/12.1 0.025 (0.64) 0.060 (1.52) 0.82 (20.8) 289 (430)

TP20(IS-OS)XT-15 036616 15 7/12.1 0.025 (0.64) 0.080 (2.03) 0.90 (22.9) 346 (515)

TP20(IS-OS)XT-16 036617 16 7/12.1 0.025 (0.64) 0.080 (2.03) 0.90 (22.9) 359 (534)

TP20(IS-OS)XT-17 036618 17 7/12.1 0.025 (0.64) 0.080 (2.03) 0.95 (24.1) 381 (566)

TP20(IS-OS)XT-18 036619 18 7/12.1 0.025 (0.64) 0.080 (2.03) 0.95 (24.1) 395 (587)

TP20(IS-OS)XT-19 036620 19 7/12.1 0.025 (0.64) 0.080 (2.03) 0.95 (24.1) 408 (608)

TP20(IS-OS)XT-20 036621 20 7/12.1 0.025 (0.64) 0.080 (2.03) 0.99 (25.1) 429 (638)

TP20(IS-OS)XT-21 036622 21 7/12.1 0.025 (0.64) 0.080 (2.03) 0.99 (25.1) 444 (661)

TP20(IS-OS)XT-22 036623 22 7/12.1 0.025 (0.64) 0.080 (2.03) 1.04 (26.4) 466 (694)

TPC Cable TypePart

NumberNumberof Pairs

Stranding Type

Insulation Thicknessin (mm)

Jacket Thicknessin (mm)

Armored Cable Diameterin (mm)

Aluminum Armored Cable

WeightLbs/mft (Kg/km)

BronzeArmored Cable

WeightLbs/mft (Kg/km)

ALUMINUM OR BRONZE ARMORED

TP20(IS)XT-1 036602* 1 7/12.1 0.025 (0.64) 0.045 (1.14) 0.335 (8.5) 54 (80) 95 (141)

TP20(IS-OS)XT-2 036603* 2 7/12.1 0.025 (0.64) 0.045 (1.14) 0.465 (11.8) 89 (132) 147 (219)

TP20(IS-OS)XT-3 036604* 3 7/12.1 0.025 (0.64) 0.045 (1.14) 0.485 (12.3) 106 (158) 167 (248)

TP20(IS-OS)XT-4 036605* 4 7/12.1 0.025 (0.64) 0.045 (1.14) 0.535 (13.6) 126 (187) 194 (289)

TP20(IS-OS)XT-5 036606* 5 7/12.1 0.025 (0.64) 0.060 (1.52) 0.605 (15.4) 165 (246) 242 (360)

TP20(IS-OS)XT-6 036607* 6 7/12.1 0.025 (0.64) 0.060 (1.52) 0.655 (16.6) 188 (280) 271 (403)

TP20(IS-OS)XT-7 036608* 7 7/12.1 0.025 (0.64) 0.060 (1.52) 0.655 (16.6) 200 (298) 283 (421)

TP20(IS-OS)XT-8 036609* 8 7/12.1 0.025 (0.64) 0.060 (1.52) 0.705 (17.9) 224 (333) 314 (467)

TP20(IS-OS)XT-9 036610* 9 7/12.1 0.025 (0.64) 0.060 (1.52) 0.745 (18.9) 245 (365) 340 (506)

TP20(IS-OS)XT-10 036611* 10 7/12.1 0.025 (0.64) 0.060 (1.52) 0.805 (20.4) 271 (403) 374 (556)

TP20(IS-OS)XT-11 036612* 11 7/12.1 0.025 (0.64) 0.060 (1.52) 0.835 (21.2) 288 (429) 396 (589)

TP20(IS-OS)XT-12 036613* 12 7/12.1 0.025 (0.64) 0.060 (1.52) 0.835 (21.2) 302 (449) 410 (610)

TP20(IS-OS)XT-13 036614* 13 7/12.1 0.025 (0.64) 0.060 (1.52) 0.875 (22.2) 324 (482) 436 (649)

TP20(IS-OS)XT-14 036615* 14 7/12.1 0.025 (0.64) 0.060 (1.52) 0.875 (22.2) 338 (503) 450 (670)

TP20(IS-OS)XT-15 036616* 15 7/12.1 0.025 (0.64) 0.080 (2.03) 0.955 (24.3) 399 (594) 522 (777)

TP20(IS-OS)XT-16 036617* 16 7/12.1 0.025 (0.64) 0.080 (2.03) 0.955 (24.3) 412 (613) 535 (796)

TP20(IS-OS)XT-17 036618* 17 7/12.1 0.025 (0.64) 0.080 (2.03) 1.005 (25.5) 437 (650) 567 (844)

TP20(IS-OS)XT-18 036619* 18 7/12.1 0.025 (0.64) 0.080 (2.03) 1.005 (25.5) 451 (671) 584 (869)

TP20(IS-OS)XT-19 036620* 19 7/12.1 0.025 (0.64) 0.080 (2.03) 1.005 (25.5) 464 (690) 594 (884)

TP20(IS-OS)XT-20 036621* 20 7/12.1 0.025 (0.64) 0.080 (2.03) 1.045 (26.5) 487 (725) 622 (926)

TP20(IS-OS)XT-21 036622* 21 7/12.1 0.025 (0.64) 0.080 (2.03) 1.045 (26.5) 502 (747) 637 (948)

TP20(IS-OS)XT-22 036623* 22 7/12.1 0.025 (0.64) 0.080 (2.03) 1.095 (27.8) 527 (784) 669 (995)

*NOTE: For aluminum armored versions, add an A (ex. 036624A). For bronze armored versions, add a B (ex. 036624B).This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.This information is not meant to replace the information in the appropriate and applicable standard or code.

36

Prysmian Group 700 Industrial Drive | Lexington, SC 29072 | +1-800-845-8507 | website: na.prysmiangroup.com Sales and Distribution: 1610 Greens Road, Suite 300 | Houston, TX 77032 | +1-281-209-1070 | +1-888-354-CABL (2225) | website: na.prysmiangroup.com/oil-gas