v LOW CAPITAL COST v FULLY WELDED TUBES v 3 PASS DESIGN v RAPID STARTUP SAVE$ TIME v LOW HEAT EMISSIONS v SMALL FLOOR SPACE NEEDED

To Compare N.C.E boilers specifications exceed the minimum requirements of relevant codes, and compare favorably to other equipment that is available). SPACE REQUIREMENTS The N.C.E range of boilers being vertical down fired design takes a minimum of valuable floor space. OPERATING COSTS Are minimized with the N.C.E boilers, the 3 pass natural circulation water wall design will provide a guaranteed minimum of 80% efficiency across the operating range of boilers. RADIATED HEAT is not a problem with N.C.E boilers, high quality thermal insulation is fitted to the boilers, ensuring a more comfortable workplace, and increased energy efficiency. QUALITY FITOUT of the N.C.E boilers Has enabled a low cost low maintenance v QUALITY FITOUT COMPONENTS steam boiler that will provide many years v EASY TO OPERATE of reliable service. v EASY TO SERVICE v PARTS READILY AVAILABLE

Page 3: Boiler Brosher New

N.C.E Series Water Tube Boilers N.C.E is the registered product range of steam generation equipment manufacture by the New Challenger Engineering Services.

The N.C.E boilers have a standard design pressure of 140psi, but are supplied fitted out to client’s specification. . All N.C.E boilers are engineered to provide a long service life with minimal maintenance requirements. N.C.E boilers carry a 12 months warranty on the shell & tubes, providing the boiler is operated and maintained within relevant Standards, including water treatment. .

Today’s N.C.E range of packaged steam boilers are the product of many years of development, that has been heavily influenced by market requirements, and loaded with features and system options to meet the clients Specification.

Page 4: Boiler Brosher New

Item / Type Unit NCE-150SG

NCE-200SG

NCE-300SG

NCE-400SG

NCE-500SG

NCE-1000SG

Rated Evaporation kg/h 150 200 300 400 500 1000

Max. Allowable Working press MPa 1(10kgf/cm2)

Heating Surface m2 1.858 4.2 4.9 4.94 4.99 10

Efficiency % 87 and over 87

Weight kg 250 450 560 730 780 900

Power Source V 220V×1¢ 220V / 380V × 3¢

Total Power Consumption kW 1.15 1.15 1.15 2.25 2.25 2.5

Blower Motor Capacity kW NIL 0.4 0.4 0.75 0.75 0.75

Feed Water Pump Capacity kW 0.75 0.75 0.75 1.5 1.5 2

Boiler Dimension

Width (W) mm 675 800 870 1,130 1,440 1440

Length (L) mm 675 865 1,085 1,300 1,300 1300

Height (H) mm 1575 2,090 2,180 2,010 2,010 2,010

Burner Type - Natural Draft

Forced Draft, first Mixing Blast

Combustion Control System - On-Off High-Low-Off

Ignition - High Voltage Electric Spark

Fuel Consumption

N. Gas Nm3/h 7.5 14.9 22.4 29.9 37.4 60.3

L. P. G Nm3/h 3.3 6.6 9.9 13.2 16.5 26.8

• • • • • •

The above specification is based on the following conditions. -Steam pressure: 10kg/cm2 -Feed water temp : 20℃ -Low heating value for fuel -Fuel gas supply pressure : 200±50mmH2O The measured efficiency is based on low heating value when the boiler is operated in full power. Measurement errors due to inevitable uncertainties are as follow. Boiler efficiency error ±1%, heat input ±3.5% 220V/1¢ is required for soft water to be controlled separately from boiler control unit. For better efficiency and performance of the products, slight modifications can be made without notice. The heating value of fuel is based the following 13A(Natural Gas) High/Low : 11,000/9,900kcal/Nm3

Page 5: Boiler Brosher New

Item / Type Unit NCE-150SG

NCE-200SG

NCE-300SG

NCE-400SG

NCE-500SG

NCE-1500SG

Rated Evaporation kg/h 150 200 300 400 500 1500

Max. Allowable Working press MPa 1(10kgf/cm2)

Heating Surface m2 1.858 4.2 4.9 4.94 4.99 17.92

Efficiency % 87 and over 84

Contained Water ℓ 22 52 61 96 96 400

Weight kg 250 450 560 730 780 3000

Power Source V 220V×1¢ 220V / 380V × 3¢

Total Power Consumption kW 1.15 1.15 1.15 2.25 2.25 5.5

Blower Motor Capacity kW NIL 0.4 0.4 0.75 0.75 2

Feed Water Pump Capacity kW 0.75 0.75 0.75 1.5 1.5 3

Boiler Dimension

Width (W) mm 675 800 870 1,130 1,440 2000

Length (L) mm 675 865 1,085 1,300 1,300 2000

Height (H) mm 1575 2,090 2,180 2,010 2,010 2,500

Burner Type - Natural Draft

Forced Draft, first Mixing Blast

Combustion Control System - On-Off High-Low-Off

Ignition - High Voltage Electric Spark

Fuel Consumption

N. Gas Nm3/h 7.5 14.9 22.4 29.9 37.4 111.0144

L. P. G Nm3/h 3.3 6.6 9.9 13.2 16.5 78

• • • • • •

The above specification is based on the following conditions. -Steam pressure : 10kg/cm2 -Feed water temp : 20℃ -Low heating value for fuel -Fuel gas supply pressure : 200±50mmH2O The measured efficiency is based on low heating value when the boiler is operated in full power. Measurement errors due to inevitable uncertainties are as follow. Boiler efficiency error ±1%, heat input ±3.5% 220V/1¢ is required for soft water to be controlled separately from boiler control unit. For better efficiency and performance of the products, slight modifications can be made without notice. The heating value of fuel is based the following 13A(Natural Gas) High/Low : 11,000/9,900kcal/Nm3