board 01 site planpdf - trail · 2017-06-05 · coloured elevations ms september 2016- ......
TRANSCRIPT
date
scale
drawn by
sheet no.
checked by
revison no.
rev no description date
RENDERING
MS
SEPTEMBER 2016
-
copyright reserved. these drawings and designs are and at all times remain the property of S.O.A to be used for the project shown and may not be reproduced without written consent.
AIRPORT TERMINAL BUILDING9019 BC-22ATrail, BC
project name
sheet title
drawing file
project no. SOA-1509
CURB SIDE
MS
s . o . aS t a n l e y O f f i c e of A r c h i t e c t u r e
709 Gore St. Nelson BC Canada V1L5C7tel. 250.777.2328 eml. [email protected]
web. www.soahome.ca
ISSUED FOR COORDINATION17/01/04
NOT FORCONSTRUCTION
shown
issued for DP 16/10/14
GENERAL NOTES:
1. THESE DRAWINGS TO BE READ IN CONJUNCTION WITH THE ARCHITECTURAL SPECIFICATIONS, GEOTECHNICAL, CIVIL, STRUCTURAL, PRE-ENGINEERED BUILDING, MECHANICAL AND ELECTRICAL DOCUMENTS. SEE THE ARCHITECTURAL SPECIFICATIONS FOR A 'SCOPE LETTER' THAT DELINEATES THE SCOPE OF THE PRE-ENGINEERED BUILDING DESIGN, SUPPLY AND INSTALLATION.
2. ALL WORK SHALL MEET ALL APPLICABLE BC BUILDING CODE, FIRE CODE, TRANSPORT CANADA REGULATIONS AND BYLAWS OF THE REGIONAL DISTRICT OF KOOTENAY BOUNDARY.
3. ALL DIMENSIONS INDICATED ARE TO CENTRE LINE OF STRUCTURE, FACE OF GIRTS OR FACE OF FRAMING, UNLESS NOTED OTHERWISE.
4. ADVISE ARCHITECT OF DISCREPANCIES, INACCURACIES AND CONFLICTS IN THE DRAWINGS.
5. ALL CONSTRUCTION EQUIPMENT TO REMAIN BELOW THE FOLLOWING ELEVATIONS*:
- EL 448m when working 112 to 132m from runway centerline- EL 450m when working 132 to 152m from runway centerline- EL 452m when working greater than 152m from runway centerline* Operation of equipment above those elevations must be requested 72 hours in advance, and approved by the City of Trail.
issued for BP 16/11/09
Pre-Tender Review 16/12/05
Pre-Tender Coordination 17/01/09
NOT FORCONSTRUCTION
issued for Presentation 17/02/20
TRAIL AIRPORT TERMINAL BUILDING - curbside.
date
scale
drawn by
sheet no.
checked by
revison no.
rev no description date
COLOURED ELEVATIONS
MS
SEPTEMBER 2016
-
copyright reserved. these drawings and designs are and at all times remain the property of S.O.A to be used for the project shown and may not be reproduced without written consent.
AIRPORT TERMINAL BUILDING9019 BC-22ATrail, BC
project name
sheet title
drawing file
project no. SOA-1509
MS
s . o . aS t a n l e y O f f i c e of A r c h i t e c t u r e
709 Gore St. Nelson BC Canada V1L5C7tel. 250.777.2328 eml. [email protected]
web. www.soahome.ca
ISSUED FOR COORDINATION17/01/04
NOT FORCONSTRUCTION
shown
issued for DP 16/10/14
GENERAL NOTES:
1. THESE DRAWINGS TO BE READ IN CONJUNCTION WITH THE ARCHITECTURAL SPECIFICATIONS, GEOTECHNICAL, CIVIL, STRUCTURAL, PRE-ENGINEERED BUILDING, MECHANICAL AND ELECTRICAL DOCUMENTS. SEE THE ARCHITECTURAL SPECIFICATIONS FOR A 'SCOPE LETTER' THAT DELINEATES THE SCOPE OF THE PRE-ENGINEERED BUILDING DESIGN, SUPPLY AND INSTALLATION.
2. ALL WORK SHALL MEET ALL APPLICABLE BC BUILDING CODE, FIRE CODE, TRANSPORT CANADA REGULATIONS AND BYLAWS OF THE REGIONAL DISTRICT OF KOOTENAY BOUNDARY.
3. ALL DIMENSIONS INDICATED ARE TO CENTRE LINE OF STRUCTURE, FACE OF GIRTS OR FACE OF FRAMING, UNLESS NOTED OTHERWISE.
4. ADVISE ARCHITECT OF DISCREPANCIES, INACCURACIES AND CONFLICTS IN THE DRAWINGS.
5. ALL CONSTRUCTION EQUIPMENT TO REMAIN BELOW THE FOLLOWING ELEVATIONS*:
- EL 448m when working 112 to 132m from runway centerline- EL 450m when working 132 to 152m from runway centerline- EL 452m when working greater than 152m from runway centerline* Operation of equipment above those elevations must be requested 72 hours in advance, and approved by the City of Trail.
issued for BP 16/11/09
Pre-Tender Review 16/12/05
Pre-Tender Coordination 17/01/09
NOT FORCONSTRUCTION
COLOURED ELEVATION - WESTScale: NTS
2
A
COLOURED ELEVATION - EASTScale: NTS
1
A
issued for Presentation 17/02/20
TIE INTO CONSTRUCTION SITE FENCE
SITE PLAN NOTES:
- THIS ARCHITECTURAL SITE PLAN INCLUDES SITE INFROMATION DERIVED FROM: HINTERLAND SURVEYING & GEOMATICS INC. PLAN SHOWING SITE INFORMATION ON TRAIL AIRPORT, WANETA HIGHWAY NO. 22 IN DISTRICT LOT 205, KOOTENAY DISTRICT. SEPTEMBER 19th, 2016
and
HINTERLAND SURVEYING & GEOMATICS INC. REFERENCE PLAN OF CONSOLIDATION OF LOTS. DECEMBER 1st, 2016.
RWL
NE
WA
CC
ES
SR
OU
TE
6.0
3.0
NEW HYDRANT
NEW PATH OF TRAVEL
60.13
HYDRANT TO DOOR
EXIT
ENTRY/EXIT
BENCH
RWL 2.0
LINE OF ROOFOVERHANGS ANDCANOPIES.SHOWN DASHED.
LINE OFEXTERIOR WALLS.
ENTRY/EXIT
T/O FIN. FLOOR = 435.50T/O SLAB VARIES, SEE STRUCTURAL.
TRAIL ATB1 STOREY
BUILDING AREA= 408 sqm. (4,395 sqft)
26.34
HYDRANT TO DOOR
NEWHYDRANT
RWL
RWL
T/O CONC.435.49
T/O CONC.435.55
T/O CONC.435.37
RWL
NEW FENCE & ACCESS.
SEE CIVIL FORSEPTIC,
SEWER ANDWATER IN THIS
AREA.
RWL
M&E EQUIPMENT AREA.MECHANICAL, ELECTRICAL AND
CIVIL DRAWINGS.
T/O CONC.435.49
FENCE & ACCESS
2.5
CONC. SIDEWALKAROUND BUILDING
NEW ASPHALT TOEDGE OF BUILDING SIDEWALK.SEE CIVIL.
1.9
CONC. SIDEWALKAROUND BUILDING
2.5
CONC. SIDEWALKAROUND BUILDING
NEW CONC. SIDEWALK (SEE CIVIL)
NEW CONC. STAIRON GRADE
R.12.0m
R.12.
0m
NEW PARKING, SIGNAGE,GRADING & CURBING.
SEE ELECT FOR LIGHTING.
1.5
NEW PARKING, SIGNAGE,GRADING & CURBING.
SEE ELECT FOR LIGHTING.
NEW DROP-OFF / LOAD ZONE (SEE CIVIL)
EXISTINGHANGAR1 STOREY
PROPERTY LINE
EXISTINGFUEL
STATION
EDGE OF EXISTING ASPHALT
NEW FENCE &ACCESS
NEW FENCE &ACCESS.
EXISTINGAPRON 1
NEW FENCE (SEE CIVIL)
SITE PLANScale: 1:250
1
A1.2
NEW PLANTINGAREA
NEW PLANTINGAREA
NEW PLANTING AREA
NEW PLANTINGAREA
NEW PLANTINGAREA
NEW PLANTINGAREA
NEW PLANTING AREA (SEE CIVIL)
HIGHWAY 22A
EXISTING VEGETATIONTO BE MAINTAINED
(TYP.)
SLOPE CONC. SIDEWALKMIN 2% AWAY FROM BLDG. (TYP)SEE CIVIL FOR GRADING AROUND BUILDING.
EXISTING FENCE
EXISTING FENCE
CONSTRUCTIONLAYDOWN AREA.
COORDINATEACCESS w/AIRPORT
OPERATIONS
5.51
NEW TEMPORARY FENCING
SE
TB
AC
K
T/O CONC.435.49
T/O CONC.435.49
- SHADED AREA REFERS TO NEW WORK DESCRIBED IN THE ARCHITECTURAL, STRUCTURAL, PRE-ENGINEERED BUILDING, MECHANICAL AND ELECTRICAL DRAWINGS HEREIN. FOR ALL OTHER WORK, SEE CIVIL DRAWINGS AND THE ELECTRICAL SITE PLAN HEREIN.
- HATCHED AREA SHOWS THE BOUNDARY OF THE TERMINAL BUILDING'S EXTERIOR Z-GIRTS.
N
date
scale
drawn by
sheet no.
checked by
revison no.
rev no description date
SITE PLAN
MS
SEPTEMBER 2016
A1.2
copyright reserved. these drawings and designs are and at all times remain the property of S.O.A to be used for the project shown and may not be reproduced without written consent.
AIRPORT TERMINAL BUILDING9019 BC-22ATrail, BC
project name
sheet title
drawing file
project no. SOA-1509
MS
s . o . aS t a n l e y O f f i c e of A r c h i t e c t u r e
709 Gore St. Nelson BC Canada V1L5C7tel. 250.777.2328 eml. [email protected]
web. www.soahome.ca
shown
NOT FORCONSTRUCTION
GENERAL NOTES:
1. THESE DRAWINGS TO BE READ IN CONJUNCTION WITH THE ARCHITECTURAL SPECIFICATIONS, GEOTECHNICAL, CIVIL, STRUCTURAL, PRE-ENGINEERED BUILDING, MECHANICAL AND ELECTRICAL DOCUMENTS.
2. ALL WORK SHALL MEET ALL APPLICABLE BC BUILDING CODE, FIRE CODE, TRANSPORT CANADA REGULATIONS AND BYLAWS OF THE REGIONAL DISTRICT OF KOOTENAY BOUNDARY.
3. ALL DIMENSIONS INDICATED ARE TO CENTRE LINE OF STRUCTURE, FACE OF GIRTS OR FACE OF FRAMING, UNLESS NOTED OTHERWISE.
4. ADVISE ARCHITECT OF DISCREPANCIES, INACCURACIES AND CONFLICTS IN THE DRAWINGS.
5. ALL CONSTRUCTION EQUIPMENT TO REMAIN BELOW THE FOLLOWING ELEVATIONS*:
- EL 448m when working 112 to 132m from runway centerline- EL 450m when working 132 to 152m from runway centerline- EL 452m when working greater than 152m from runway centerline* Operation of equipment above those elevations must be requested 72 hours in advance, and approved by the City of Trail.
Pre-Tender Coordination 17/01/09