blarh100 amplifier 900mhz

41
BRUKER Version BLARH100 Amplifier 900MHz User Manual 001

Upload: others

Post on 22-Nov-2021

26 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: BLARH100 Amplifier 900MHz

BLARH100

Amplifier 900MHzUser Manual

BRUKER

Version

001
Page 2: BLARH100 Amplifier 900MHz

The information in this manual may be altered without notice.

BRUKER accepts no responsibility for actions taken as a resultof use of this manual. BRUKER accepts no liability for any mis-takes contained in the manual, leading to coincidental damage,whether during installation or operation of the instrument. Un-authorised reproduction of manual contents, without writtenpermission from the publishers, or translation into another lan-guage, either in full or in part, is forbidden.

This manual was written by

BRZUCZKIEWICZ Serge

© August 23, 2000: Bruker SA

Wissembourg, France

Manual P/N: Z31593DWG-Nr: 1305001

Page 3: BLARH100 Amplifier 900MHz

Contents

Contents ............................................................... 3

Index ..................................................................... 5

1 General description ................................................ 71.1 Introduction ......................................................................... 71.2 System Check ..................................................................... 71.3 Initial Turn On Procedure ..................................................... 8

2 Safety ...................................................................... 92.1 Labels ................................................................................. 9

Dangerous Area ...............................................................9Name Plate ......................................................................9

3 BLARH100 Operation.............................................113.1 Front Panel ....................................................................... 11

Display ..........................................................................12RF Connectors ..............................................................12Interface Connectors RS485 ..........................................13

3.2 Rear Panel ........................................................................ 13

4 General Information.............................................. 154.1 Amplifiers .......................................................................... 154.2 Switchs and detection ........................................................ 154.3 Control Board .................................................................... 15

5 Amplifier diagrams ............................................... 17

6 Specifications ....................................................... 356.1 Common Characteristics .................................................... 356.2 General specifications ....................................................... 36

Figures ................................................................ 37

Tables .................................................................. 39

User Manual Version 001 BRUKER 3 (41)

Page 4: BLARH100 Amplifier 900MHz

Contents

4 (41) BRUKER User Manual Version 001

Page 5: BLARH100 Amplifier 900MHz

Index

Numerics

1H/19F ................................................................................................................ 15

A

AC input voltage.................................................................................................... 7

B

Banking Med input .............................................................................................. 12Blanking High input ............................................................................................. 12

E

External blanking................................................................................................... 7

H

HHigh Input ......................................................................................................... 12HMed input.......................................................................................................... 12

I

Indicator +15V on................................................................................................ 12Indicator +28V on................................................................................................ 12Indicator +5V on.................................................................................................. 12Indicator -15V on................................................................................................. 12Indicator Duty Cycle on ....................................................................................... 12Indicator High on................................................................................................. 12Indicator Med on ................................................................................................. 12Indicator Mismatch on ......................................................................................... 12Indicator Overdrive on......................................................................................... 12Indicator Overheat on.......................................................................................... 12Indicator Pulse Width on ..................................................................................... 12Indicator RF Power FLT on ................................................................................. 12

N

Nominal input level................................................................................................ 7

Q

QNP/19F/1H........................................................................................................ 12

User Manual Version 001 BRUKER 5 (41)

Page 6: BLARH100 Amplifier 900MHz

Index

R

Revision Number................................................................................................... 9RF QNP/19F/1H output....................................................................................... 12RF X input ........................................................................................................... 12RS485 interface .................................................................................................. 15

S

SBS BUS............................................................................................................. 13Serial Number ....................................................................................................... 9

T

Type of the product ............................................................................................... 9

6 (41) BRUKER User Manual Version 001

Page 7: BLARH100 Amplifier 900MHz

1General description 1

Introduction 1.1

The BLAH100 / 900MHz (P/N:W1345047) is a linear pulse amplifier specificallydesigned for Nuclear Magnetic Resonance (NMR) applications.

It is a class AB linear amplifier and provides a 100W peak power outputs over thefrequency range 850-900MHz.

A low power output of 10W peak power over the range 850-900MHz is provided atthe 19F output.

An input is provided for the X amplifier to switch the 1H/19F/X channels to a QNPprobe.

The amplifier is realised by employing N-CHANNEL MOS BROADBAND RFPOWER FETs of the latest generation. The unit can provide full power for anycombination of pulse width of 100ms and duty cycle up 10%. Its built-in protectioncircuitry may allow lower limitations.

An electronic protection circuitry has been designed to protect against:

• Excessive power output level (overdrive)

• Excessive pulse repetition rate (over duty-cycle protection)

• Excessive pulse width (over pulse-width)

• More than 50% reflected RF power (mismatch ≥=6)

• Thermal overload (overheat)

The amplifier is powered by an internal Switched power supply assembly that pro-vides the 28VDC for the power amplifiers, in addition to all low level voltages forthe system.

The supply is auto-protected for overcurrent and overvoltage.

The entire unit is housed in a 19", 4U, 520mm rack cabinet.

System Check 1.2

Before applying power for the first time the following items should be checked :

• The AC input voltage from the Amplifier must be compatible with 176 to264 VAC range.

• External blanking ( gating ) pulses must be supplied to the amplifier at the BLKinput and with the proper level and logic polarity.

• The Amplifier has a nominal input level of +4dBm. Ensure that the system driv-ers are operating at these levels.

User Manual Version 001 BRUKER 7 (41)

Page 8: BLARH100 Amplifier 900MHz

General description

Initial Turn On Procedure 1.3

The following list describes how to turn on the Amplifier and what should be seenas this occurs.

Before starting this procedure, make sure that you have properly followed instruc-tions in the "System Check" section.

1. Connect the amplifier to the AC line and turn the circuit breaker on the frontpanel, to ON.

2. Observe the display on the front panel :The +30V, +15V, -15V and +5V display LEDs must be lighted.

3. System is now fully operational.

8 (41) BRUKER User Manual Version 001

Page 9: BLARH100 Amplifier 900MHz

2Safety 2

Labels 2.1

Labels are provided to alert operating and service personnel to conditions thatmay cause personal injury or damage to the equipment from misuse or abuse.Please read the labels and understand their meaning.

Dangerous Area 2.1.1

WARNING ! High Voltage.

Name Plate 2.1.2

The Amplifier BLARH100 can be identified by a name plate at the front panel ofthe unit which has information as follows :

• (A) Ser. This line contains an assembly number which identifies the Part and the Serialnumber of the product.

• (B) TypeThis line contains the designation of the product.

• (C) RevisionThis cell indicates the revision number which identifies the product configura-tion. The initial revision is 00.

Disconnectline cord

before opening

Ser.Type

C

A

B

User Manual Version 001 BRUKER 9 (41)

Page 10: BLARH100 Amplifier 900MHz

Safety

10 (41) BRUKER User Manual Version 001

Page 11: BLARH100 Amplifier 900MHz

3BLARH100 Operation 3

Front Panel 3.1

The BLARH100 / 900MHz front panel is fitted with a display for status monitoring,two RS485 interface connectors and the RF connectors.

Figure 3.1. The BLAH100 / 900MHz Front Panel Design

LINE

OFF

ON

RS 485

HIGH ON

+28V

+15V

-15V

+5V

MED ON

RF POW. FLT

OVERHEAT

OVERDRIVE

D. C.

P. W.

MISMATCH

845-900MHzBLARH100

0 123

456 789A

BCDEF

HIGH MEDHIGH MED

HF BLANKING

1H19FXQNPXBLA

SEL.X/F H/F

User Manual Version 001 BRUKER 11 (41)

Page 12: BLARH100 Amplifier 900MHz

BLARH100 Operation

Display 3.1.1

RF Connectors 3.1.2

Table 3.1. Indicators

+28V on Indicates that the 28V supply is correct.

+15V on Indicates that the +15V supply is correct.

-15V on Indicates that the -15V supply is correct.

+5V on Indicates that the +5V supply is correct.

Overdrive on Indicates when the power limit has been reached.

Duty Cycle on Indicates when the duty cycle limit has been reached.

Pulse Width on Indicates when the pulse width limit has been reached.

Mismatch on Indicates when the max. reflected power limit has been reached

RF Power FLT on Lights ON when one of the above limits has been reached.

Overheat on Indicates that the thermistor located on the RF Module heat-sink has sensed excessive temperature or ventilation is stopped .All gatings are locked on the amplifier until the unit cools.

High on The 100W high power amplifier send RF pulse.

Med on The 10W low power amplifier send RF pulse.

Table 3.2. Connectors

HHigh in RF in SMA type connectors (female).+4dBm drive for nominal power (100W).

HMed in RF in SMA type connectors (female).+4dBm drive for nominal power (10W).

BLNK Med in Blanking signals BNC type connector (female).TTL logic, 5V = blanking , 0V = unblanking.(When BLANKING, no RF Power).

BLNK High in Blanking signals BNC type connector (female).TTL logic, 5V = blanking , 0V = unblanking.(When BLANKING, no RF Power).

X in RF INPUT for X amplifier. N type connectors (female).

QNP/19F/1H out RF OUT 1H/19F/QNP. N type connectors (female).

12 (41) BRUKER User Manual Version 001

Page 13: BLARH100 Amplifier 900MHz

Rear Panel

Interface Connectors RS485 3.1.3

The Control I/O interface connections are 15 pins, D shape sub-miniature typeconnectors mounted on the SBS BUS Controller.

SBS BUS = Serial Bruker Spectrospin Bus

The following table shows the pinout of the master and slave connectors.

Rear Panel 3.2

The rear Panel of the BLAH100 900MHz Amplifier is free of elements in exceptionof the three pole ( 2P + E ) line filter socket.

Table 3.3. RS485 pinout

Pin 1 Shield

Pin 2 Transmit data line +

Pin 3 Wake up line /WUP

Pin 4 Receive data line +

Pin 5 NC

Pin 6 GND

Pin 7 GND

Pin 8 GND

Pin 9 Transmit data line -

Pin 10 NC

Pin 11 Receive data line -

Pin 12 NC

Pin 13 VRS ( +12V )

Pin 14 VRS ( +12V )

Pin 15 VRS ( +12V )

User Manual Version 001 BRUKER 13 (41)

Page 14: BLARH100 Amplifier 900MHz

BLARH100 Operation

14 (41) BRUKER User Manual Version 001

Page 15: BLARH100 Amplifier 900MHz

4General Information 4

Amplifiers 4.1

The BLAH100 900MHz amplifier P/N:W1345047, provides a high power outputsat nominal 100W in the frequency range of 850-900MHz.

The RF section of the system consists of a linear preamplifier of about 10W wichdrive a median stage of 40W and finaly the output push-pull of 150W.

The linear gain of the amplifier is about 50dB.

The linear amplifier is a class AB with the all stages blancked with the BlankingHigh signal on the transistor gates.

It can deliver a CW power of 25W max.

The second amplifier is a 10W push-pull in the frequency range of 850-900MHz.

The linear gain is about 38 dB.

The linear amplifier is a class AB with all stages blancked with the Blanking Medsignal on the transistor gates.

It can deliver a CW power of 10W max.

Switchs and detection 4.2

A fast pin diode switch allow to control the output witch get the 100W or the 10Wpower.(1H/19F)

A slow relais control the output witch get the X Input or the 1H/19F output. Beforegoing to the outputs the RF signals are detected in two bidirectional coplers to getan image of the output RF pulse amplitude for reflected and forward waves.

Control Board 4.3

The BLA Control Board consists of circuitry for monitoring the output power of theamplifier wich is detected in the bi-directional coupler, and to condition the inputblanking ( gating ) signals and deliver them to the amplifiers.

The monitoring is effective on overstress in peak power, average power versusduty cycle and pulse width, so as reflected power,but also for heatsink tempera-ture to protect against thermal overstress and power supplys monitoring or fansdefaults.

In case of default the gating signals are disabled, and the corresponding defaultstatus display on the front panel is on.

All these informations are also sended to the CPU via the RS485 interface.

User Manual Version 001 BRUKER 15 (41)

Page 16: BLARH100 Amplifier 900MHz

General Information

16 (41) BRUKER User Manual Version 001

Page 17: BLARH100 Amplifier 900MHz

5Amplifier diagrams 5

User Manual Version 002 BRUKER 17 (41)

Page 18: BLARH100 Amplifier 900MHz

2 1

A

B

C

D

12

J1

LINE IN(ON REAR PANEL)

POWER SUPPLY

P/N:W1301880ASSY "A"+28V

GND

+28V

PGND

P2

J2

P9

J9

J4

X300IN

J1P1

SWITCHES

P2 J2

J3

J4P4

P3

COPLERS AND

J5

XQNPOUT

J6

19FOUT

J7

1HOUT

J11

SELX/F\

J12

SELH/F\

ASSY "F"P/N:W1345180

RF1 100W

RF2 10W

FRONTPANNELASSY "L"

P/N:W1305717

M

45047

IFIER 900MHZ

DRAWN:DATE:

APPROV:DATE:

DWG:

EC:

W4B133067

00

SB

DW02/03/99

04/03/99

VISA:

VISA:

SHEET: 1/1 -

Figure 5.1.

BL

AX

H10

0 Am

plifier 900MH

z

18 (41)B

RU

KER

User M

anual Version 002

8 7 6 5 4 3

345678

D

C

B

A

ASSEMBLY

P/N:W1345181ASSY "E"

REAR FAN

R1+28V

P2 J2FAN STATUS

STATUS

P1J1STATUS

LED BOARDASSY "D"

FRONTPANNELASSY "I" P/N:W1301877

P/N:W1341045

BLNK1

BLNK2

J8

BLNK1HIGH

J10

BLNK2MED

FAN STATUS

GND

P1 J1

ASSEMBLY

P/N:W1301881ASSY "E"

FRONT FAN

SUPPLIES STATUS

SUPPLIES

FWD1

RELAY IDENTIFICATION

P4

P23

J23

J4

P1

J1

P3

J3

P21

J21 J18

P18

J8 J12

P9

J9

P8 P12

X2

I/ORS 485

X1

I/ORS 485

P/N:W1346097ASSY "B"

BLA CONTROL BOARD 4

J7

J6

J5

REF1

FWD2

P7

P6

P5

REF2

J2

P2

T' SENSE1BLK1'\

J15

P15

BLK1\

J14

P14

P3 P7

P1

BBIS BOARDP/N:H5783

X1

J22

P22

J16

P16

T' SENSE2

P1

BLK10W\

J26

P26

P3 J3J3

RF HMED IN ASSY "H"P/N:W1345171

J1

BLMH10

J9

J4

RF2 10W

P4BLMH100ASSY "G"

P/N:W1345172

J3 J7

P1 J1

J6

J2 P2

RF1 100W

PGND

J5

P5

+28V

P4

J4J7

P7

J8

P8

PGND+28V

J2

RF HHIGH IN

BLOCK DIAGRA

ART: W13

BLARH100 AMP

Page 19: BLARH100 Amplifier 900MHz

Figure 5.2.BLA P

ower Supply

2 1

A

B

C

D

12345678

15V

15V

ND

5V

VISA:

VISA:

B SHEET: 1/1

S.a.d.i.s

SPECTROSPIN

User M

anual Version 002B

RU

KER

19 (41)

8 7 6 5 4 3

D

C

B

A

SUPPLIESSTATUS

54321

J3

6 GND+5R\-15R\+15R\+28R\

J3'654321

L

2*6,3AT

J1

220V ACLINE IN

N

T ELBASMP/P600 BRU

(P/N:56537)

+28V

J5

J42*FASTON

POWERSUPPLY

J2

1

2

3 +15V

-15V

GND

PGND

F1FERRITE FILTER EMI D6-7MM

+

-

G

++5V4

ART:

BLA POWER SUPPLY ASSEMBLY

W1301880 DRAWN:DATE:

APPROV:DATE:

DWG:

EC: 03 DW05/09/96

W4S131105

05/09/96PHB

Page 20: BLARH100 Amplifier 900MHz

Figure 5.3. BLA Power Supply Interconnect Drawing

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

POWER SUPPLY ASSEMBLY "A"

LINE IN

GNDJ9.9

123

123

J1P1

PHASENEUTRALGROUND

GND-15V+15V+5V

1234

1234

P2 J2

J1B

+15VJ9.5TO COPLER & SWITCH

ASSY 'F'

ASSY 'B'TO CONTROL BOARD

J3B

123456

123456

J3P3

NC+28V STATUS+15V STATUS-15V STATUS+5V STATUSGND

+28V

PGND

1

2

P/N:W1301880

J4

J5

TO BLMH100 ASSY 'G'

BLA POWER ASSEMBLY ASSY "A"INTERCONNECT DRAWING

ART: W1301880 EC: DRAWN:DATE:

APPROV:DATE:

DWG:

DW

W4W133167

SB04/03/99

01/03/99VISA:

VISA:

SHEET:A 1/1

20 (41) BRUKER User Manual Version 002

Page 21: BLARH100 Amplifier 900MHz

Figure 5.4. BLA Control Board 4 Interconnect Drawing 1

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

BLA CONTROL BOARD 4 ASSEMBLY "B"

ON HEATSINKK682.6.8K

ASSEMBLY "G"

CTNP2

1

2

3

J2

1

2

GND

THERMAL SENSE 1

NC3

1

2

GND

THERMAL SENSE 2

J26

NC3

1

2

P26

3

CTN

ON HEATSINKK682.6.8K

ASSEMBLY "H"

TO BBIS BOARD

12345678

P22

12345

J22

678

GND

GND

I2CCLKI2CDATA

+5V

NC

P/N:W1346097

910

910

INTERCONNECT DRAWINGBLA CONTROL BOARD 4 ASSY "B"

ART: W1346097 EC: DRAWN:DATE:

APPROV:DATE:

DWG: W4W133074

SB04/03/99

DW02/03/99

VISA:

VISA:

SHEET: - 1/3

User Manual Version 002 BRUKER 21 (41)

Page 22: BLARH100 Amplifier 900MHz

Figure 5.5. BLA Control Board 4 Interconnect Drawing 2

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

BLA CONTROL BOARD 4 ASSEMBLY "B"

TO DISPLAYASSEMBLY "D" J1D J1D.1

J1D.2J1D.3J1D.4J1D.5J1D.6J1D.7J1D.8J1D.9J1D.10

123456789

10

P12

12345678910

J12

+5V OUT+28V FAULT+15V FAULT-15V FAULT+5V FAULT

MISMATCH FAULT

RF POWER FAULT

MULTI-PULSE MODE

RF2 ON

111213141516

TEMPERATURE FAULT

DUTY CYCLE FAULTPULSE WIDTH FAULTOVERDRIVEGND

RF1 ON111213141516

J1D.11J1D.12J1D.13J1D.14J1D.15J1D.16

ASSEMBLY "E"TO FAN

J1E

J2E

J1E.2J1E.3J1E.4

J2E.2

J1E.1

J2E.1

1234

P18

12

P21

1234

GNDFAN 1 STATUSFAN 2 STATUSFAN 3 STATUS

J18

12

GNDFAN 1 STATUS

J21

12

J3

NC+28V STATUS

34

FAN 2 STATUSFAN 3 STATUS

1NC2

P3

34

J3A.2

J2E.3J2E.4

J2ATO POWER SUPPLYASSEMBLY "A" J3A.3

J3A.4J3A.5J3A.6

3456

3456

+15V STATUS-15V STATUS

GND

P/N:W1346097

+5V STATUS

INTERCONNECT DRAWINGBLA CONTROL BOARD 4 ASSY "B"

ART: W1346097 EC: DRAWN:DATE:

APPROV:DATE:

DWG: W4W133075

SB04/02/99

DW02/03/99

VISA:

VISA:

SHEET:- 2/3

22 (41) BRUKER User Manual Version 002

Page 23: BLARH100 Amplifier 900MHz

Figure 5.6. BLA Control Board 4 Interconnect Drawing 3

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

12

J1

GND-15V

BLA CONTROL BOARD 4 ASSEMBLY "B"

12

P1

POWER SUPPLYASSY "K"

J1F

34

1

P4

34 +5V

+15V

1

J4

DETECTION FORWARD 1 (100W)

1

J5

DETECTION REFLECTED 1

1

J6

DETECTION FORWARD 2 (10W)

1

P5

1

P6

J2F

J3F

ASSEMBLY "F"& SWITCH

TO COPLER

J4F

P8

1

P7

J8

1

J7

DETECTION REFLECTED 2

1

1

J9

BLNK1 (HIGH)

BLNK2 (MED)

1

1

P9

J8I

J10I

ASSEMBLY "I"TO FRONT PANEL

TO BLMH100ASSEMBLY "G"

J3G

J7G

1

P15

1

P14

1

J15

BLK1\ OUTPUT

1

J14

BLK1'\ OUTPUT

P/N:W1346097

1

J16

BLK10W\ OUTPUT1

P16

J1HASSEMBLY "H"

TO BLMH10

INTERCONNECT DRAWINGBLA CONTROL BOARD 4 ASSY "B"

ART: W1346097 EC: DRAWN:DATE:

APPROV:DATE:

DWG:

DW02/03/99

W4W133076

SB04/03/99

VISA:

VISA:

SHEET: - 3/3

User Manual Version 002 BRUKER 23 (41)

Page 24: BLARH100 Amplifier 900MHz

Figure 5.7. Universal BBIS Board Interconnect Drawing

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

BBIS BOARD

12345

12345

X1

+5V

A0A1A2

GND

I2CCLKI2CDATA

678910

6789

10

J22ASSY 'B'

TO CONTROL BOARD

P/N:H5783

INTERCONNECT DRAWINGUNIVERSAL BBIS BOARD

ART: H5783 EC:00 DRAWN:DATE:

APPROV:DATE:

DWG: W4W133168

SB04/03/99

DW02/03/99

VISA:

VISA:

SHEET: A 1/1

24 (41) BRUKER User Manual Version 002

Page 25: BLARH100 Amplifier 900MHz

Figure 5.8. BLA Status Led Board Interconnect Drawing

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

BLA STATUS BOARD ASSEMBLY "D"

J12B.1J12B.2J12B.3J12B.4J12B.5J12B.6J12B.7J12B.8J12B.9J12B.10

1234

P1

56789

10

1234

J1

5678910

+5V+28V ON+15V ON-15V ON+5V ON

MISMATCH FAULT

RF POWER FAULT

MULTI-PULSE MODE ON

RF2 ON

111213141516 NC

OVERHEAT FAULT

DUTY CYCLE FAULTPULSE WIDTH FAULTOVERDRIVE FAULT

P/N:W1301877

RF1 ON111213141516

J12B.11J12B.12J12B.13J12B.14J12B.15J12B.16

J12B

INTERCONNECT DRAWINGBLA STATUS BOARD ASSY "D"

ART: W1301877 EC: DRAWN:DATE:

APPROV:DATE:

DWG:

DW

W4W131580

03/01/94

SB02/11/94

VISA:

VISA:

SHEET: 1/1

S.a.d.i.s

SPECTROSPIN

User Manual Version 002 BRUKER 25 (41)

Page 26: BLARH100 Amplifier 900MHz

Figure 5.9. BLA Rear Fan Assembly Interconnect Drawing

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

J21B.1J21B.2J21B.3J21B.4

1234

P2

1234

J2

SPAREFAN1 STATUSFAN2 STATUSFAN3 STATUS

BLA REAR FAN ASSEMBLY

56789

SPARE+28V FAN1+28V FAN2+28V FAN3GND FAN1-3

P/N:W1345181

56789PGND

J18B.1 1

P1

1

J1

SPARE

BLA FRONT FAN ASSEMBLY

23456789

SPARE

FAN1 STATUSFAN2 STATUSFAN3 STATUS

+28V FAN1+28V FAN2+28V FAN3GND FAN1-3

P/N:W1301881

23456789

R1+28V

PGND

J18B.2J18B.3J18B.4

J18B

J21B

TO CONTROL BOARDASSY 'B'

INTERCONNECT DRAWINGBLA FAN ASSY "E"

ART: W1345181 EC: DRAWN:DATE:

APPROV:DATE:

DWG: W4W133069

SB04/03/99

DW02/03/99

VISA:

VISA:

SHEET: - 1/1

26 (41) BRUKER User Manual Version 002

Page 27: BLARH100 Amplifier 900MHz

2 1

A

B

C

D

12345678

+28V GND

LABH10P/N:W1346136

2*500mA

UF2840G

+6dB

00mA

UF2840G

6dB

+40dbm TypRF2 OUT

(10W)

VISA:

VISA:

A SHEET: 1/1

Figure 5.10.BLMH

10 RF A

mplifier M

odule 700-1000MH

z

User M

anual Version 002B

RU

KER

27 (41)

8 7 6 5 4 3

D

C

B

A

THERMALSENSE

BLK2

+28V

TSC1428

BLANKING

LM317T

V. REG

+8V

2.6A

22R50W

22R50W 60mA

+8V

2*5

+

400mA

MHL8118

+15dB

-3dB

MAV11

+12dB

+4dbmRF2 IN

Gain : 36db Typ

(HMED)

RF BLOCK DIAGRAM

ART:

BLMH10 RF AMPLIFIER MODULE700-1000MHZ

W1345171 DRAWN:DATE:

APPROV:DATE:

DWG:

EC: 00 DW26/02/99

SB04/03/99

W4B133096

Page 28: BLARH100 Amplifier 900MHz

Figure 5.11. BLMH10 RF Amplifier Module 700-1000MHz Interconnect Drawing

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

BLMH10 ASSEMBLY "H"

TO ASSEMBLY "F"

TO ASSEMBLY "I"FRONT PANEL

COPLER & SWITCH

J3I

RF2

1

P3

1

P2

1

J3

1

J2

RF2 IN HMED

RF2 10W OUT

+28V

+28V

1

1

J7

J8

1

1

P7

P8

+28V

PGND

TO ASSEMBLY "F"POWER SUPPLY

J16 1

P1

1

J1

BLANKING BLK10W\

J9

1

2

ON HEATSINK

P9

K682.6K8

1

2

J26.1

J26.2

TO ASSEMBLY "B"BLA CONTROL BOARD

P9

P/N:W1345171

J9

INTERCONNECT DRAWINGBLMH10 RF AMPLIFIER ASSY "H"

ART: W1345171 EC: DRAWN:DATE:

APPROV:DATE:

DWG:

DW

W4W133072

26/02/99

VISA:

VISA:

SHEET: 1/1

SB04/03/99

28 (41) BRUKER User Manual Version 002

Page 29: BLARH100 Amplifier 900MHz

2 1

A

B

C

D

12345678

+28V GROUND

C203

+8dB

RF OUT

C203

+8dB

DRAWN:DATE:

APPROV:DATE:

DWG:

VISA:

VISA:

SHEET:W4B133098

SB

A

DW26/02/99

04/03/99

1/1

TT40

Figure 5.12.BLMH

100 RF A

mplifier M

odule 900MH

z

User M

anual Version 002B

RU

KER

29 (41)

8 7 6 5 4 3

D

C

B

A

THERMAL

SENSE

+28V

+8V

TSC1427

BLANKING

BLK1'\

TSC1428

BLANKING

BLK1\

+8V

LM317T

V. REG

+8V

MAV11

+12dB

-6dB

MHL8118

+15dB

UF2840G

+6dB

UF2840G

+6dB

C203

+8dB

RF IN

+4dbm

P/N:W1346129

LABH20

P/N:W1346130

ART: W1345172

RF BLOCK DIAGRAM

BLMH100 RF AMPLIFIER MODULE900MHZ

EC: 00

TT40

LABH100

Page 30: BLARH100 Amplifier 900MHz

Figure 5.13. BLMH100 RF Amplifier Module 900MHz Interconnect Drawing

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

BLMH100 ASSEMBLY "G"

TO ASSEMBLY "F"

TO ASSEMBLY "I"FRONT PANEL

COPLER & SWITCH

J2

RF1

1

P1

P2

1

1

J1

1

J2

RF IN HHIGH

RF1 100W OUT

+28V

+28V

1

1

J4

J5

1

1

P4

P5

PGND

+28V

TO ASSEMBLY "A"POWER SUPPLY

J15

J14

1

P3

1

P7

1

J3

BLK1\ IN

1

J7

BLK1'\ IN

J6

1

ON HEATSINKK682.6K8

1

P6

J2.1BLA CONTROL BOARDTO ASSEMBLY "B"

J2.2

P6

2

P/N:W1345172

J6

2

INTERCONNECT DRAWINGBLMH100 AMPLIFIER ASSY "G"

ART: W1345172 EC: DRAWN:DATE:

APPROV:DATE:

DWG:

DW

W4W133071

26/02/99VISA:

VISA:

SHEET: 1/1

DW04/03/99

30 (41) BRUKER User Manual Version 002

Page 31: BLARH100 Amplifier 900MHz

Figure 5.14. Couplers & Switches Assembly

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

RF210W

From ASSEMBLY"G" AND "H"

RF1100W

J1

J4

J1

J4

REF1 (100W)

FWD1

REF2 (10W)

FWD2

To DSPControl

Board

12345678910

P23

J3

J2J2

J3

1 2

R.I.

RELAY IDENTIFICATION

J1

+15V

GND

123456789

J1

2 13

J3J1J10

2 13

J2J4

J3 J1 J9 J2 J4 J2

SELX/F\

J11

XQNP

J5

X300IN

J4

19F

J6

OPTION QNPW1303382

SELH/F\

J12

1H

J7

BLOCK DIAGRAMCOUPLERS & SWITCHES ASSEMBLY

ART: W1345180 EC: 00 DRAWN:DATE:

APPROV:DATE:

DWG: W4B133100

SB19/02/99

DW10/02/99

VISA:

VISA:

SHEET:A 1/1

I N T

E R

F A

C E

W 1

3 0

1 8

8 2

W 1

3 4

6 1

4 0

B D

C H

2 7

7 3

4 2

3

R E

L A

Y S

W I

T C

H

W 1

3 4

6 1

4 2

B L

O C

K

S W

I T

C H

W 1

3 4

6 1

3 9

B D

C H

3 6

User Manual Version 002 BRUKER 31 (41)

Page 32: BLARH100 Amplifier 900MHz

Figure 5.15. Pin Diode Transfer Switch

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

RF CONTINUITYSELH/F\

TRUTH TABLE

0

1

J1

J1 J2

J4 J3

J3

;

;

J2

J4

J2

PIN DIODE TRANSFER SWITCHP/N:W1346143

J1

J3 J4

+15V

SELH/F\SELH/F\ J5

+15v3

2

J10

GROUND

INTERFACE TRANSFER SWITCH H/F\

1

P/N:W1346149

PIN DIODE TRANSFER SWITCH

BLOCK DIAGRAM650-1000MHZ

ART: W1346142 EC: 00 DRAWN:DATE:

APPROV:DATE:

DWG:

DW

W4B133099

SB19/02/99

03/02/99VISA:

VISA:

SHEET:A 1/1

32 (41) BRUKER User Manual Version 002

Page 33: BLARH100 Amplifier 900MHz

Figure 5.16. Switch Relay for QNP Option

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

RF CONTINUITYACTUATORSELX/F\

TRUTH TABLE

0

1

ENERGIZED

DE-ENERGIZED

J1

J1 J2

J3

J2

J3

;

;

J4

J4

J2Ref: R556712009

FAILSAFE TRANSFER SWITCH

P/N:73423J1

J3

+

ACTUATOR

-

J4

+15V

P1'

X/F\

R.I.

RELAY INDENTIFICATION

P23

12345678910

SWITCH RELAY FOR QNP OPTIONFONCTIONS & TRUTH TABLE

ART: W1303382 EC: 00 DRAWN:DATE:

APPROV:DATE:

DWG:

DW

W4B133108

SB01/06/99

26/05/99VISA:

VISA:

SHEET:A 1/1

User Manual Version 002 BRUKER 33 (41)

Page 34: BLARH100 Amplifier 900MHz

Figure 5.17. Couplers & Switches Interconnect Drawing

8 7 6 5 4 3 2 1

A

B

C

D

12345678

D

C

B

A

12

J9

COUPLERS & SWITCHES ASSEMBLY " F"

12

P9

ASSY'A'TO POWER SUPPLY +15V

GND

J4

3456789

3456789 GND

+15V IN

FWD1

REF1

FWD2

REF2

J5

J6

J7

ASSY 'B'TO CONTROL BOARD

TO BLMH100ASSY 'G' J2G

J23

100W IN

RELAY IDENTIFICATION

10W IN

X300 IN

X QNP OUT

J4L

J5L

J4HASSY 'H'TO BLMH10

TO FRONT PANELASSY 'L'

J6L

J7L

J11L

19F OUT

1H OUT

SEL X/F\ IN

P/N:W1345180

SEL H/F\ INJ12L

INTERCONNECT DRAWINGCOUPLERS & SWITCHES ASSY "F"

ART: W1345180 EC: DRAWN:DATE:

APPROV:DATE:

DWG:

DW11/02/99

SB19/02/99

W4W133169

VISA:

VISA:

SHEET:A 1/1

34 (41) BRUKER User Manual Version 002

Page 35: BLARH100 Amplifier 900MHz

6Specifications 6

Common Characteristics 6.1

RF Input Connector SMA (F)RF Output Connector N (F)Blanking Pulse Connector BNC (F)

User Manual Version 001 BRUKER 35 (41)

Page 36: BLARH100 Amplifier 900MHz

General specifications

6.2

Table 6.1. BLARH100 / 900 general specifications

CHANNEL HMED

0 MHz

typ.

x.

full range

n

t 1 dB compression

Operation

.

typ. (due to blanking signal)

m @ 1 Hz

m @ 1 Hz

n full range

n

n

0 W for 500ms Pulse Width

36 (41)B

RU

KER

User M

anual Version 001

RF SPECIFICATIONS CHANNEL HHIGH

Frequency Range 840 to 900 MHz 650 to 100

Linear Gain 52 dB ± 1 typ. 38 dB ± 1

Gain Flatness ± 1.5dB max. ± 1 dB ma

Minimum Pulsed Output Power(at nominal input + 4 dBm)

100 W min. full range 10 W min.

CW Output Power 25 W max. (internal limitation) no limitatio

Linear Output Power 50 W typ. at 1 dB compression 5 W min. a

Amplifier Biasing Class AB Operation Class AB

Blanking Delay < 1 µs typ. < 1 µs typ

RF Rise Time < 100 ns < 100 ns

RF Fall Time < 50 ns < 50 ns

DC Ringing ± 200 mV typ. (due to blanking signal) ± 200 mV

Input Noise Figure 7 dB max. 7 dB max.

Output Noise Power (Unblanked) < - 115 dBm @ 1 Hz < - 129 dB

Output Noise Power (Blanked) < - 174 dBm @ 1 Hz < - 174 dB

IN/OUT Impedance 50 ohms 50 ohms

Input V.S.W.R. 1,5 max. 1,5 max.

Output Harmonics 30 dBc max. at 100 W 30 dBc mi

Pulse Width (int. limitation) 500 ms @ 100 W (up to CW at 25 W) no limitatio

Duty Cycle (int. limitation) 25 % @ 100 W (up to 100 % at 25 W) no limitatio

Amplitude Droop < 8 % @ 100 W for 100 ms Pulse Width< 5 % @ 50 W for 100 ms Pulse Width

< 5% @ 1

Page 37: BLARH100 Amplifier 900MHz

Figures

1 General description 7

2 Safety 9

3 BLARH100 Operation 11Figure 3.1. The BLAH100 / 900MHz Front Panel Design ...................... 11

4 General Information 15

5 Amplifier diagrams 17Figure 5.1. BLAXH100 Amplifier 900MHz ..............................................18Figure 5.2. BLA Power Supply ...............................................................19Figure 5.3. BLA Power Supply Interconnect Drawing .............................20Figure 5.4. BLA Control Board 4 Interconnect Drawing 1 .......................21Figure 5.5. BLA Control Board 4 Interconnect Drawing 2 .......................22Figure 5.6. BLA Control Board 4 Interconnect Drawing 3 .......................23Figure 5.7. Universal BBIS Board Interconnect Drawing ........................24Figure 5.8. BLA Status Led Board Interconnect Drawing ........................25Figure 5.9. BLA Rear Fan Assembly Interconnect Drawing ....................26Figure 5.10. BLMH10 RF Amplifier Module 700-1000MHz .......................27Figure 5.11. BLMH10 RF Amplifier Module 700-1000MHz Interconnect

Drawing ...............................................................................28Figure 5.12. BLMH100 RF Amplifier Module 900MHz ..............................29Figure 5.13. BLMH100 RF Amplifier Module 900MHz Interconnect

Drawing ...............................................................................30Figure 5.14. Couplers & Switches Assembly ...........................................31Figure 5.15. Pin Diode Transfer Switch ...................................................32Figure 5.16. Switch Relay for QNP Option ...............................................33Figure 5.17. Couplers & Switches Interconnect Drawing ..........................34

6 Specifications 35

User Manual Version 001 BRUKER 37 (41)

Page 38: BLARH100 Amplifier 900MHz

Figures

38 (41) BRUKER User Manual Version 001

Page 39: BLARH100 Amplifier 900MHz

Tables

1 General description 7

2 Safety 9

3 BLARH100 Operation 11Table 3.1. Indicators ...................................................................... 12Table 3.2. Connectors .................................................................... 12Table 3.3. RS485 pinout ................................................................. 13

4 General Information 15

5 Amplifier diagrams 17

6 Specifications 35Table 6.1. BLARH100 / 900 general specifications ......................... 36

User Manual Version 001 BRUKER 39 (41)

Page 40: BLARH100 Amplifier 900MHz

Tables

40 (41) BRUKER User Manual Version 001

Page 41: BLARH100 Amplifier 900MHz

Notes

User Manual Version 001 BRUKER 41 (41)

Lastpage