black mountain engineering, llc wastewater remediation service clean water = water quality = liquid...

34
Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life [email protected] goblueh2o.com Tel: 602-350-2422

Upload: mariano-lorrain

Post on 31-Mar-2015

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Black Mountain Engineering, LLCWastewater Remediation Service

Clean Water = Water Quality = Liquid Life [email protected]

goblueh2o.com Tel: 602-350-2422

Page 2: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

What is it?• The separation of contaminants from water using

electricity and then physical separation from the water using stainless steel micron filtration.

What are the results?• Water that is reusable and clean for discharge.

• Solids that are in a form that can be disposed into a non-hazardous landfill.

Electro Coagulation (EC) and

Advanced Mechanical Separator

(AMS) NO CHEMICALS USED!

Page 3: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

First Phase Cleaning Process

With the use of clean electricity, the Electro Coagulation Systems efficiently removes a wide range of contaminants with a single system. The molecular structure of the contaminate becomes oxidized into a non-hazardous form or coagulant.

Electro Coagulation (EC)

6 GPM Unit 600 GPM Unit50 GPM Unit

Page 4: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

How does it Work?• Electrical current passes through

water using bipolar electric metal plates/blades in a patented chamber.

• Converts alternating current (AC) to direct current (DC) voltage.

• Destabilizes suspended, emulsified, or dissolved oil and other constituents in an aqueous medium.

Electro Coagulation

Page 5: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation

+ _

VERTICAL UPFLOW

+ ELECTRODE

(blade)

-ELECTRODE

(blade)

Sacrificial electrodes – typically iron or aluminum

Page 6: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation Top View of Parallel Plates, 6 GPM

Flow SpillsOver to

Patented Chamber

Flow isFrom

Bottom Up Between

Plates

Page 7: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation Top View of Parallel Plates, 600 GPM

Flow Moves

From

Bottom Up

Between

Plates

Page 8: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation

6 Gallon Per Minute (GPM) System

Plates and

Patented Chamber

Page 9: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation UnitVolume Processing Sizes

Page 10: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation UnitFootprint Sizes

Page 11: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation

BENEFITS

• no chemicals; no chemical safety requirements• kills virus, cysts, & coliform bacteria• better removal capabilities than for Chemical

Coagulation • removes species that CC cannot remove• produces cleaner water and less sludge• sludge filterable; pass leachability tests• EC results in 80% less solids• Solids dewaters 76% faster• minimal setup time• no temperature effect• no moving parts; small footprint

Page 12: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro CoagulationApplications:

PRETREATMENT FOR FILTRATION (AMS)

• Currently, pretreatment to AMS and RO

• Removal of suspended solids is most cost-effective application of EC & AMS

• EC better removes Fats, Oils, & Greases (FOG)

Page 13: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro CoagulationResults of U.S. EPA Extraction Procedure (EP)

Toxicity TestsConcentration (mg/l)

Contaminant Sample E Sample FAllowed Limit

After EC After EC

Arsenic <0.01 <0.01 5.0

Barium <0.1 <0.1100Cadmium <0.01 <0.011.0Chromium <0.20 <0.055.0Lead <0.05 <0.055.0Mercury <0.0002 <0.002 0.2Selenium <0.01 <0.011.0Silver <0.01 <0.015.0

Page 14: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro CoagulationManufacturer’s Wastewater Before and After EC

Treatment

Concentration (mg/l) ___

Contaminant Raw After Treatment% Removal

Chromium, Total 37.9 0.10 99

Chromium, Hexavalent 21 <0.05 99

Zinc 18.1 0.16 99

Page 15: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro CoagulationManufacturer’s Wastewater Before and After EC Treatment

Bacteria sp. Raw After Treatment % Removal

•Bacteria 110,000,000.00 cfu 2,700.00 cfu 99.99•Coliform 318,000,000.00 cfu < 1.00 cfu 99.99•E. coli >2,419.20 mpn 00.00 mpn 99.99•Enterococcus 83.00 mpn >10.00 mpn 82.87•Total Coliform >2,420.20 mpn 00.00 mpn

99.99

Page 16: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation

Results of Radioactivity Testing at a Government Facility

CONTAMINANT BEFORE AFTER REMOVAL RATE (%)

Americium-241 71.9900 pCi/L 0.5700 pCi/L 99.20

Plutonium-239 29.8500 pCi/L 0.2900 pCi/L 99.00

Radium 1093.0000 pCi/L 0.1000 pCi/L 99.99

Uranium 0.1300 mg/L 0.0002 mg/L 99.83

Page 17: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation Has Been Successfully Used to:

• harvest protein, fat, and fiber from food processor waste streams

• recover emulsified oil from slop oil• separate drilling mud to make water reusable• clean and separate production water• clean and separate fracturing water• recycle water, allowing closed loop systems• remove metals and oil from wastewater• recondition antifreeze by removing oil, dirt, and

metals

Page 18: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation Has Been Successfully Used to:

• recondition brine chiller water by removing bacteria, fat, etc

• pretreatment before finer TSS removal technologies like AMS

• precondition boiler makeup water by removing silica, hardness, TSS, etc

• recondition boiler blow down by removing dissolved solids eliminating the need for boiler chemical treatment

Page 19: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Electro Coagulation Has Been Successfully Used to:

• remove BOD, TSS, TDS, FOG, etc., from wastewater before disposal to POTW, thus reducing or eliminating discharge surcharges

• de-water sewage sludge and stabilize heavy metals in sewage, lowering freight and allowing sludge to be land applied

• condition and polish drinking water• remove chlorine and bacteria before

water discharge or reuse

Page 20: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Second Phase Cleaning ProcessAfter contaminates are separated from the waste stream

with the electro coagulation, a filtration system is employed to remove additional suspend solids (TSS).

The Advanced Mechanical Separator.

Advanced Mechanical Separator(AMS)

Uses 100 down to 0.05 micron filters

Page 21: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Advanced Mechanical Separator Post EC

• In concert with the electro coagulation, they employ the use of a revolutionary processing system without having to use chemicals.

• Advanced Mechanical Separator (AMS) computer-controlled self-cleaning stainless steel filtration system removes particles, minerals, or anything in solid form from production water.

• Different modules can be assembled to achieve

specific stated objectives for cleaning various fluids.

Page 22: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

The AMS system under low air pressure removes molecules from water. Post EC, this is accomplished through these steps:

• Processing the waste stream through sintered stainless steel filters using air pressure.

• Absolute filtration of solids using 100 down to 0.05 microns filters.• Configuring the process to "target" different water and solids

depending on the size of the filter used and the amount of air pressure applied.

• Customizing each system to a small footprint which is energy efficient.

• System design is fully integrated with pumps that are durable in many industries.

• Each system is scalable and modular, so large integrated systems can be built.

• Maintenance is simplified through the self-cleaning function of the system, while it operates continuously under the management of field personnel.

Advanced Mechanical Separator

Page 23: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Advanced Mechanical Separator Two Models

X-Pod Model

Processes 50 GPM

4 Filtering Media Pods

Fat Boy Model

Processes 100 GPM

8 Filtering Media Pods

Page 24: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Advanced Mechanical Separator Volume Processing Sizes

Page 25: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Advanced Mechanical Separator Footprint Sizes

Page 26: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Advanced Mechanical Separator

Each media pod contains 8 sintered stainless steel micron filters.

X-Pod has 32 filters.

Fat Boy has 64 filters.

Page 27: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Advanced Mechanical Separator

Sintered Stainless Steel

Micron Filters Sizes

0.05, 0.10, 0.30, 0.50, 0.70, 1.0, 3.0, 5.0,

10.0, 40.0, 100.00

Page 28: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Advanced Mechanical SeparatorSample Water Processed by AMS

Page 29: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

EC and AMSPlant Operation Setup (500 GPM)

Page 30: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

EC and AMSMobile Operation Setup (50 to 250

GPM)

Page 31: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

EC and AMSMobile Operation Setups (50 to 250

GPM)

Page 32: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

EC and AMS UsageWastewater Industry Sectors

Page 33: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

EC and AMSAdditional Information

☻EC Studies and Test Results - United States Naval Research Study (Contaminate Testing) - Under the auspices of the U.S. Department of Energy by the

University of California, Lawrence Livermore National Laboratory (Uranium Testing)☻EC Studies and Test Results - Rocky Mountain Oilfield Testing Center Study (Owned by the U.S.

Department of Energy (Filtering Study) - World Oil Magazine Article (April 2010 Edition)

These results, other studies and test analysis can be found

on our website: GoBlueH2O.com

Page 34: Black Mountain Engineering, LLC Wastewater Remediation Service Clean Water = Water Quality = Liquid Life cleanwater@goblueh2o.com goblueh2o.com Tel: 602-350-2422

Go Blue H2O = Clean [email protected]

GoBlueH2O.com