B11 SHIMS UNDER PEDESTALSPLACE B11s (WHOLE OR IN SEGMENTS) UNDER THE PEDESTAL IN A STAIRSTEP FASHION TO COMPENSATE FOR SLOPING SUBSTRATES. USE ONLY B11 SHIMS FOR THIS APPLICATION. MAXIMUM (3) THREE.
Installation & Slope Compensation Details
Details12/5/2006©UCP
BISON DECK SUPPORTS ......THE LEVEL OF EXCELLENCE©
SAMPLE LAYOUT USING WOOD TILES OR PAVERS
ALL PEDESTAL TABS REMOVED
TWO PEDESTAL TABS REMOVED
USE ALL FOUR PEDESTAL TABS
TO DETERMINE THE NUMBER OF PEDESTALS:1. COUNT ONE (1) PEDESTAL FOR EACH TILE/PAVER USED. (DIAGRAM: 12 TILES)2. ADD ONE (1) PEDESTAL FOR EACH PERIMETER TILE ON 2 SIDES (DIAGRAM: 6 + 12 = 18)3. ADD TWO (2) PEDESTALS TO THE TOTAL (DIAGRAM: 18 + 2 = 20 PEDESTALS NEEDED)
B11 SHIMS ON TOP OF PEDESTALSB11’S MAY BE PLACED ON TOP OF PEDESTALS TO ACCOMODATE FOR MINOR LEVEL-ING OF PAVERS WITH THICKNESS VARIATIONS. NOTE: 1/4 WEDGE PIECES MUST BE ADHERED TO THE PEDESTAL & EACH OTHER WITH CONSTRUCTION ADHESIVE, SECURING THE WEDGE TO THE PEDESTAL AND NOT MORE THAN 2 WEDGES TOGETHER.
SLOPE COMPENSATION DETAILS
TOP LEVELING: PH5 = UP TO 5/8” PER FOOT SLOPE. ROTATE THE PH5 TO PRECISELY LEVEL THE PEDESTAL TOP ON SURFACES WITH SLOPE UP TO 5/8” PER FOOT. COMES STANDARD ON ALL VERSADJUST MODELS & CAN BE ADDED TO LEVEL.IT MODELS.
BASE LEVELING: LD4 = 1/4” PER FOOT SLOPESTACK 2-4 LD4’S UNDER PEDESTAL BASE TO COMPENSATE FOR 0”-1” PER FOOT SLOPE. WHEN USING TWO OR MORE LD4’S ROTATE ONE IN RELATION TO THE OTHER TO ACHIEVE THE RIGHT SLOPE COMPENSATION
bisondeck supports
USE ¼ PIECE W/ CONSTRUCTION ADHESIVE
90˚ 90˚
SECTION VIEW 1B
EDGE OF 4’ X 4’DRAIN SUMP
ROOF DRAIN
1/4” PER FT. SLOPE (TYP)IN THE FIELD OF THE ROOF
USE LLD4’s FOR SLOPECOMPENSATION
SECTION VIEW 1B
INSERT & ADHERETAB IN PLACE
SPECIAL PLACEMENTS
PERIMETER
EDGE PEDESTALS WITH 2 TABS REMOVED (TYPICAL)
DOOR THRESHOLDNOTE: PEDESTAL HEIGHT EQUALS DISTANCE FROM THRESHOLD TOSURFACE BELOW, MINUSDECK SURFACE MATERIAL THICKNESS
CORNERPEDESTALS ALL 4 TABS REMOVED (TYPICAL)
NARROW FIELD CUT PAVERS
STANDARD PEDESTAL PLACEMENT USING ALL 4 SPACER TABS (TYPICAL)
ENLARGED PLAN VIEW
1A
BISON DECK SUPPORTS
©UCP2005
SECTION VIEWMINIMAL SLOPE COMPENSATION(NOT TO SCALE)
STONE, CONCRETE OR WOOD PAVER / TILE
TOP OF PAVER / TILE
PEDESTAL WITH TABSREMOVED AS NECESSARY 3/16”
(STANDARD)
LLD4 APPLIED FOR STANDARDSLOPE COMPENSATION
1A
©UCP2005
©UCP2006
1C
ENLARGED PLAN VIEW AT DIAGONAL PERIMETER EDGE
SECTION VIEW 1C
2 PEDESTALSSHOWN WITH TABSREMOVED ANDREINSERTED ASNECESSARY
FIELD CUT PAVERS
REINSERT TABS &ADHERE IN PLACE
CUT OFF BASEFLANGE FOR CLOSEPERIMETER
TOP OF PAVER
STEP DOWN OPTION #1 STEP DOWN OPTION #2
ENLARGED PERIMETER EDGE DETAIL
GROUND APPLICATION DETAIL (FFB)
USE FLOATING FOUNDATION BASE (FFB) UNDER EACH PEDESTAL PLACED ON THE GROUND
INSULATION APPLICATION DETAIL (FIB)
REINSERT TABS & ADHERE IN PLACE WITH CONSTRUCTION ADHESIVE
PERIMETER EDGE
ADHERE SMALLPAVER TO TOPOF PEDESTAL
CUT BASE FLANGE FORCLOSE FIT PERIMETER
ADHERE SMALL PAVER SECTIONS TO TOPOF PEDESTAL WITH WATERPROOF ADHESIVE
BOTTOM VIEW OF PEDESTAL
FACTORY SCOREDGUIDELINES FOREASY CUTTINGCUT BASE FLANGEAS NECESSARYFOR CLOSEPERIMETER
TOP VIEW OF PEDESTALSECURING PERIMETER FACIAON GRADE
TREATED FACIA BOARD
TREATED WOOD SPACER3 1/2” TEK SCREWGRADE
CONCRETE PAVER OR WOOD TILE
PEDESTALFFB
INSTALLATION DETAILS
©UCP2005
©UCP2005
©UCP2005
©UCP2005
©UCP2005©UCP2005
©UCP2005©UCP2005
REQUIRED: FLOATING INSULATION BASE (FIB) MUST BE PLACED UNDER EACH PEDESTAL USED ON SMOOTH SURFACED ROOFING MEMBRANES WITH INSULATION.
NOTES:1. ALL DRAWINGS & DETAILS PROVIDED ARE EXAMPLES ONLY.2. INSTALLATION TO BE COMPLETED IN ACCORDANCE WITH MANUFACTURER’S SPECIFICATIONS.3. DRAWINGS NOT TO SCALE.4. FOR COMPLETE SPECIFICATIONS, PRODUCT AND PURCHASING INFORMATION VISIT www.BisonDeckSupports.com
MORE APPLICATION & TRANSITION DETAILS
TWO LAYER FLOOR PANELS FOR STAGES24”
BACKSET LOWER PANEL ONALL SIDES1/8” tab 3/16” tab
DIMENSIONAL JOISTS WITH DECK
OPTIONAL CORNER BRACKET
4 X 4 2 X 4Or other 2X product
2 FT. WOOD TILE 2 FT. CONCRETE OR STONE PAVER
SHIMS
STEP SHIM FOR SLOPE(IF NEEDED)
NOTE::SEE SLOPE COMPENSATION DETAILS FOR STEP SHIMS
FS1 FASTENER SYSTEM -ATTACHES LEVELIT TILES TO PEDESTAL
WOOD TILE TO PAVER TRANSITION
BASE FLANGE CAN BE TRIMMED
2 x 4
WOOD TO PAVER TRANSITION
BASE FLANGE CAN BE TRIMMED
1.75” PLANKING
WOOD PLANKING TO PAVER TRANSITION
CONTINUOUS 2X STRINGER
OPTIONAL SLEEPER AT JOISTS
DIMENSIONAL STRINGERS WITH SUBFLOOR
a United Construction Products, Inc. Company www.BisonDeckSupports.com 1975 W. 13th Ave. Denver, CO 80204 Ph: (303) 628-7950 Fax: (303) 825-5988 Toll Free: (888) 412-4766
©10/1/2005UCP
LEVEL.IT SAFETY WINDOWS
TO ENSURE PEDESTAL STABILITY, SCREW PIECES TOGETHER UNTIL SAFETY WINDOWS ARE COMPLETELY COVERED.
PRODUCT #: FS1 FASTENING KIT. SCREW ANCHOR INTO TOP OF PEDESTAL. ADJUST WASHER TO FASTEN BETWEEN THE BOTTOM RAIL OF THE TILE AND THE UPPER SLAT. SCREW WASHER INTO ANCHOR AND TIGHTEN.
WOOD TILE ANCHOR SYSTEM
VERSADJUST VDPH5 DESIGN FEATURES
8 attachment holes (if needed)
Screw adjustment regulator,up to 1 3/8”
Adjustable Coupler up to 4 1/2”
Slope Compensator,to 5/8” per foot
Base surface area: 47”
Collar for bracing at elevations over 16”
1/8” Spacer Tabs (Removable)
4.5mm Spacer Tabs (Removable)
Preset Height Indicator
Versadjust Key ToolAvailable
To release “stop lock”, unscrew pedestal until it stops & insert a nail into the hole, as shown, to release the tab.