Bio Zapper v2.1 http://www.ekovortex.com/
Page 1 of 6
1. Specifications
• Frequency adjustment from 1 Hz to 1000000 Hz (1MHz) with 1 Hz
resolution • Setting running time 1-240 minutes with 1 min resolution • Memory the last used settings (No need every time adjusts frequency
and time) • Can memory 20 programs, and each program can have up to 10
different frequency's and running times • Generates a rectangular signal amplitude 12 V with a positive offset of
0.25V • Adjustable Duty Circle from 10 to 90 % (Increased zapping efficient) • Sweep function (If you activate sweep function, then he will generate
frequencies around desire frequency whit adjusted sweep) • Buzzer (You will be inform when adjusted time is passed) • Frequency Stability +/- 0.01% (Frequency is generated by a
microprocessor that runs on 20Mhz crystal oscillator) • Double outputs • External power supply 12 VDC • Protection against short-circuit Frequency list: http://www.ekovortex.com/FrequencyList.html
Disclaimer Bio Zapper is well-made, reliable devices that produce rectangle waveforms. We make no claims regarding Bio Zapper healing or healing properties. If you suffer from a persistent or life threatening condition, we recommend that you seek the help of a doctor or medical specialist who is qualified to help you. Use of Bio Zapper is at your own risk.
Bio Zapper v2.1 http://www.ekovortex.com/
Page 2 of 6
2. Instructions
Legend Start/Stop button
Arrow left
Arrow right
Arrow down
Arrow up
Normal zapping Step 1.
This is starting screen Press arrow down
Step 2. Use left and right arrows to set Duty Circle. Default value is 50% After that press arrow down
Step 3. Use left and right arrows to set frequency After that press arrow down
Step 4. Use left and right arrows to set time After that press arrow down
Step 5. This screen shows adjusted frequency and time Press start/stop
Step 6. Bio zapper is now ready to start producing adjusted frequency Press start/stop to start zapping, or if you want to change settings press arrow down (step 2)
Step 7. Zapping is started Here you can see adjusted frequency and time counting down Whit start/stop is possible to stop zapping any time (step 9)
Step 8. When adjusted time reach 0, Bio Zapper will you inform with buzzer To repeat zapping with same settings press start/stop To change settings press arrow down (step 2)
Step 9. To repeat zapping with same settings press start/stop To change settings press arrow down (step 2)
Bio Zapper v2.1
Set DC [%] xx
Set Freq [Hz] xxxxxxx
Set Time [min] xxx
Freq:xxxxxxx [Hz] Time:xxx [min]
BioZapper v2.1 Ready to start
Running f:xxxxxxx t:xxx
Stopped by timer
Stopped by user
Bio Zapper v2.1 http://www.ekovortex.com/
Page 3 of 6
Making programs Step 1.
This is starting screen Press arrow down
Step 2. Use left and right arrows to set Duty Circle. Default value is 50% After that press arrow down
Step 3. Use left and right arrows to set frequency After that press arrow down
Step 4. Use left and right arrows to set time After that press arrow down
Step 5. This screen shows adjusted frequency and time Press arrow down
Step 6. Press start/stop
Step 7. Use left and right arrows to set program After that press arrow down
Step 8. Use left and right arrows to set program step Press start/stop to save adjusted frequency and time or arrow down if you don’t want to save (step 2)
Step 9. Adjusted frequency and time is saved in program After 1 second BioZapper will go on step 3
Bio Zapper v2.1
Set DC [%] xx
Set Freq [Hz] xxxxxxx
Set Time [min] xxx
Freq:xxxxxxx [Hz] Time:xxx [min]
Save to program
Program:x
Step:xx
Program saved
Bio Zapper v2.1 http://www.ekovortex.com/
Page 4 of 6
Running programs Step 1.
This is starting screen
Step 2. Use left and right arrows to set Duty Circle. Default value is 50% Press arrow down until you reach next screen
Step 3. Press start/stop
Step 4. Use left and right arrows to choose program Press start/stop to start program, or if you want to change settings press arrow down (step 2)
Step 5. Bio zapper is now ready to start program Press start/stop to start zapping, or if you want to change settings press arrow down (step 2)
Step 6. Zapping is started P – Program number / S – Step number F – Frequency / t – Time Bio Zapper will run all steps where programmed time is higher then 0 with adjusted Duty Circle
Step 7. After last step is finished, Bio Zapper will you inform with buzzer To repeat zapping with same settings press start/stop To change settings press arrow down (step 2)
Step 8. To repeat zapping with same settings press start/stop To change settings press arrow down (step 2)
Bio Zapper v2.1
Program:xx
BioZapper v2.1 Ready to start
Running P:xx S:xx f:xxxxxxx t:xxx
Stopped by timer
Set DC [%] xx
Run Program
Stopped by User
Bio Zapper v2.1 http://www.ekovortex.com/
Page 5 of 6
Running Sweep Step 1.
This is staring screen Press arrow down
Step 2. Use left and right arrows to set Duty Circle. Default value is 50% Press arrow down
Step 3. Use left and right arrows to set middle frequency Press arrow down
Step 4. Use left and right arrows to set time Press arrow down
Step 5. This screen shows adjusted frequency and time Press arrow down until you reach next screen
Step 6. Press start/stop
Step 7. Use left and right arrows to adjust sweep frequency
Step 8. Bio zapper is now ready to start sweep Press start/stop to start zapping, or if you want to change settings press arrow down (step 2))
Step 9. Zapping is started Here you can see current frequency and time counting down Whit start/stop is possible to stop zapping any time
Step 10. When adjusted time reach 0, Bio Zapper will you inform with buzzer To repeat zapping with same settings press start/stop To change settings press arrow down (step 2)
Step 11. To repeat zapping with same settings press start/stop To change settings press arrow down (step 2)
Bio Zapper v2.1
Set DC [%] xx
Set Freq [Hz] xxxxxxx
Set Time [min] xxx
Freq:xxxxxxx [Hz] Time:xxx [min]
Run Sweep
Mid freq:xxxxxxx Sweep:xxxxxx
BioZapper v2.1 Ready to start
Running Sweep F:xxxxxxx t:xxx
Stopped by timer
Stopped by User
Bio Zapper v2.1 http://www.ekovortex.com/
Page 6 of 6
3. Explanations Duty Circle With duty circle (DC) you can adjust what percentage of output signal will be above 0.25V. When DC is 10% average voltage on output is: 1.2V When DC is 50% average voltage on output is: 6 V When DC is 90% average voltage on output is: 10.8 V Average voltage is voltage that you will get if you measure output voltage with voltmeter. According to some people with highest DC you can increase zapping efficiency. Original DC on Dr. Hulda Clark zappers is 50% Formula: for calculating average output voltage is: 12 x (DC/100) More information’s you can get from http://en.wikipedia.org/wiki/Duty_cycle Sweep function With sweep function you can run frequencies in some range. For example if you want to run frequencies from 29000 to 31000 Hz, then you need to do following:
1. Set middle frequency to 30000 Hz 2. Set time let say to 7 minutes 3. Set sweep to 1000 Hz 4. Start zapping
Frequency increase is calculated: f_inc = sweep x 2 / time f_inc = 1000 x 2 / 7 = 286 Hz Start frequency is calculated: f_start = middle frequency – sweep + (f_inc / 2) f_start = 30000 – 1000 + (386/2) = 29000 + 143 = 29143 Hz Stop frequency is calculated: f_end = f_start + (f_inc x (time – 1)) f_end = 29143 + (286 x (time – 1)) = 29143 + (286 x 6) = 30859 Hz Bio zapper will produce frequencies from 29143 to 30859 Hz on next way: 1 minute: 29143 Hz = 30000 – 10000 + (386/2) 1 minute: 29429 Hz = (29143 + 286) 1 minute: 29715 Hz = (29429 + 286) 1 minute: 30001 Hz = (29715 + 286) 1 minute: 30287 Hz = (30001 + 286) 1 minute: 30573 Hz = (30287 + 286) 1 minute: 30859 Hz = (30573 + 286)