Page 1: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

BIODEGRADABLE PERIPHERAL

IGAKI-TAMAI STENTS

„PERSEUS“ STUDIES

G.Biamino

University of Leipzig – Heart Center

Department of Clinical and Interventional Angiology

Leipzig, Germany

Page 2: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Rationale for Biodegradable Stents

Although remarkable technological

advances had led to the development of

very effective Nitinol stents dedicated to

the SFA, which offer the promise of

addressing both the problems of acute

reocclusion and late restenosis after

PTA, many concerns remain.

Page 3: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Rationale for Biodegradable Stents

• Metallic stents induce

- varying degree of thrombogenesis

- significant initial hyperplasia, with

restenosis rates 15 – 40%

• Long term effects of metallic stents in human

arteries are still unknown

• Metallic stents remaining in place may be

obstacles to additional treatments

Concerns

Page 4: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Stent fractures

and

In-stent

restenoses

THE NEW

NIGHTMARE

In SFA

Page 5: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Rationale for Biodegradable Stents

• Restenosis commonly occurs within 4 - 9months after endovascular interventions

• The clinical need for stent scaffolding islimited after this period

• Stents made of absorbable materials may bean ideal alternative

• Absorbable stents can also be useful for thelocal administration of pharmacologicalagents

Page 6: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

IGAKI - TAMAI STENT

Biodegradable Peripheral Stent

Page 7: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

CompatibleMRI

NonFerromagnetism

Proximal and distal edgesStent of radio-opaque markers

ExcellentLongitudinal flexibility

21.17% (at 5mm), 17.69%(at 6mm),

17.22% (at 7mm), 15.27%(at 8mm)

Polymer surface area (expanded)

< 1.6% (at 5mm), < 1.9%(at 6mm),

< 3.2%(at 7mm), < 3.7%(at 8mm)

Percentage shortening on expansion

0.68mm2Polymer cross-sectional area

(expanded)

7mm(stent type at 5mm and 6mm)

9mm(stent type at 7mm and 8mm)

Expansion range

5.0, 6.0, 7.0, 8.0 mmAvailable diameter

36mmAvailable length

0.24 mm(0.009inch)Strut thickness

Zig zag herical coilStent design

PLLA(poly-L-lactic acid) medical gradeMaterial composition

Stent Specification

Page 8: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Peripheral Stent Delivery System

8F

60cm60cm

8F

Balloon-expandable system covered with a protective sheath

6.0, 7.0, 8.0 mmBalloon size:

4 cm (Stent lenth 36 mm)Balloon length:

60 cm and 120 cmSystem length:

Outer diameter; 8FProtective sheat:

Page 9: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

PERSEUS- Study design

• Prospective, non-randomized, two

centers pilot study

• Ruth-Class 2-3 patients with de novo

lesions of the SFA, Type A, B and C

• Max. 2 stents were permitted, limiting

the length of the lesion to cm6 - 7

Page 10: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

PERSEUS- Study Objectives

• The aim of the study was to

demonstrate the feasibility and

safety of a new biodegradable

polymer poly-l-lactid (PLLA) stent in

patients with suitable SFA lesions.

Page 11: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

PERSEUS- Study Endpoints

• Primary technical success rate

• Major adverse events

• Vessel ruptur

• Acute and subacute stent

thrombosis

• Stent migration

• AMI

• Death

Page 12: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

PERSEUS- Study Endpoints

• Primary,primary-assisted and

secundary patency rate at 12 and

24 months

• Number of reinterventions

• Follow-up at 1,3,6,12,24 mo

Page 13: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

PERSEUS- Study Population

• N = 103 patients scheduled for

PTA St. IIb

• Lesions location SFA

• Lesion length 4.5 cm (+/-1.2 cm)

• Stenting on indication

Page 14: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

G.H.1

Page 15: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

G.H.2

Page 16: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

G.H.3

Page 17: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

G.H.5

Page 18: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

PERSEUS- Study Results

• Primary success rate 100 %

• No serious adverse event

Page 19: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department
Page 20: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Pre Intra

Post

Page 21: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department
Page 22: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

6 - Months Follow-up Results

• NO acute or subacutereocclusions

• 25 % symptomatic restenoses , all

successfully retreated

• Asymptomatic restenoses

(max. 50 -60%) in 18%.

Page 23: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department
Page 24: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department
Page 25: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department
Page 26: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Conclusion

• The Biodegradable PLLA IGAKI-

TAMAI-Stent is safe

• Stenting of the SFA is feasible

• Primary Assisted Patency Rate 100 %

in this first pilot-study

The encouraging results have to be

validated in larger trials including more

complex lesions

Page 27: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Material composition : PLLA(poly-L-lactic acid) medical grade

Stent design : Zig zag helical coilStrut thickness : 0.009 inch (0.24 mm)

Radio-opaque markers : 2 gold markersCurrently available diameters : 5.0 mmCurrently available length : 78 mm

IGAKI-TAMAITM STENT

78 mm

Page 28: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Stent Delivery System

Protective sheath : Outer diameter; 7 FSystem length : 110 cmBalloon length : 8 cm (Stent length 78 mm)Balloon size : 5.0 mm

8F

60cm110cm

7 F

Balloon-expandable system covered with a protective sheath

0.018“

Page 29: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

PERSEUS II- Study design

• Prospective, non-randomized, pilot

study ( Leipzig and Mercogliano)

• 65 patients with de novo lesions of

the SFA, Type B and C

• Max. 2 stents were permitted, limiting

the length of the lesion to cm15

Page 30: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

PERSEUS- Study Results

• Primary success rate 100 %

• No serious adverse event

Page 31: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Ea.1

DIFFUSE PAOD WITH BILATERAL

FUNCTIONAL SFA OCCLUSION

Page 32: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

BEFORE AFTER PTA

Ea.3Ea.2

Rigth

SFA

Page 33: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

STENTING

DISTAL PROXIMAL

E.4E.3

Page 34: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Ea.5Ea.4

AFTER LONG

INFLATION AFTER STENTING

Rigth

SFA

Page 35: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

E.1

Left

SFA

E.2

BEFORE AFTER PTA

Page 36: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

FINAL RESULT

E.5 E.6

Page 37: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

3 Months Follow - up

• No major adverse events

• No acute or subacute occlusion

• No symptomatic re-stenoses !!!!!

Page 38: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

6 - Months Results

• Two reocclusionssuccessfully retreated

• 28 % symptomatic restenoses,all successfully retreated

• Asymptomatic angiographicrestenosis ( 50-60%) in 6 cases

Page 39: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

6 – 10 months Follow-up

• Primary assisted patency rate

• Secondary patency rate

93%

100%

Page 40: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

End of the presentation

Page 41: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department

Perseus

He killed the monster Medusa;

and we are comparing Medusa

with

METAL STENTS !!!!

Page 42: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department
Page 43: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department
Page 44: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department
Page 45: BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS… · BIODEGRADABLE PERIPHERAL IGAKI-TAMAI STENTS „PERSEUS“ STUDIES G.Biamino University of Leipzig – Heart Center Department