INTRODUCTION
The Biomedical Data Reader is a hand held unit that can
be attached with a patient to monitor heart beat rate and
body temperature remotely. Data collected from thepatient is send to the master unit using an RF interface.
This unit helps the medical team to monitor the patient
data periodically and the data can be stored in a computer
file for future reference.
-
8/6/2019 Bio Medical Data Reader
5/17
MOTIVATION
By the introduction of a Bio Medical Data Reader variousparameters of a patient like heartbeats, temperature, blood pressureetc.. Can be monitored remotely.
These parameters can be displayed on a screen placed in the dutyroom on request or on time basis.
Critical condition can be informed with an alert tone.
Lack of manual observation will also be eliminated.
-
8/6/2019 Bio Medical Data Reader
6/17
BLOCK DIAGRAM
AT89C51
Sensor &
ADC
Heart
Beat
Module
RF
MODULE
LCD
BDR BASE MODULE:
-
8/6/2019 Bio Medical Data Reader
7/17
Microcontroller:
The AT89C51 is the brain of BDR system.
This microcontroller is responsible for collecting heart beat pulses from
sensor stage and counting them
From the ADC IC the temperature values & from the sensor the heartbeatvalues are taken into the microcontroller.
These temperature and heartbeat values are send to the remote station using
RF Module
Sensor & ADC
The temperature sensor takes the body temperature and gives it into the
ADC IC.
The ADC IC converts the analog value into digital and gives it into the
microcontroller. Here the ADC produces 8 bit value.
-
8/6/2019 Bio Medical Data Reader
8/17
Heart Beat Module:
Using heart beat module takes the heart beat pulses and gives it into themicrocontroller
LCD:
LCD serves as a useful interface for the user .
It provides simple interface between microcontroller and LCD. The LCD has 16 character x 2 line display facility
RF Module:
The communication between the BDR and master unit is through atwo way RF link.
The BDR units will automatically transfer data to the master unit.
Every RF modules can be identified by their unique network address, data istransported with out clashes. The RF range is 30 meters.
-
8/6/2019 Bio Medical Data Reader
9/17
Level
c verter
le
PC
BD aster le :
The data from the base module is received using a RF module and gives
it into the MAX232 IC and transferred it into the PC. The data are
display on the PC screen.
-
8/6/2019 Bio Medical Data Reader
10/17
HARDWARE
BDR Base Module
A
1 1Tuesday, January 26, 2010
Title
Size Document Number Rev
Date: Sheet of
5V
0
5V
5V
5V
0
0
5V
0
3.3V
0
data
Data IP
clockchipse lect
12345678
Data OP
U6
ADC0838
18
17
13
9
16
19
12
11
1
2
3
4
5
6
7
8
15
14
20
10
CS
DI
SE
COM
CLK
V+
VREF
AGND
CH0
CH 1
CH2
CH3
CH4
CH5
CH6
CH7
SARS
DO
VCC
GND
- +
D3IN4007 x 4
1
2
3
4
C101000mf / 63V
R3
1K Preset V
1
3
2
R2220E
U4 LM317
2
1
3VOUT
ADJ
VIN
JE1
LCD
12345678910
11
12
13
14
15
16
12345678910
11
12
13
14
15
16
C833pf
C9
33pf
CRYSTAL
U1
AT89C51
9
18
19
20
293031
40
1234567
8
2122232425262728
10111213141516
17
3938373635343332
RST
XTAL2
XTAL1
GND
PSENALE/PROG
EA/VPP
VCC
P1.0P1.1P1.2P1.3P1.4P1.5
P1.6P1.7
P2.0/A8P2.1/A9
P2.2/A10P2.3/A11P2.4/A12P2.5/A13P2.6/A14P2.7/A15
P3.0/RXDP3.1/TXD
P3.2/INTOP3.3/INT1
P3.4/TOP3.5/T1
P3.6/WRP3.7/RD
P0.0/AD0P0.1/AD1P0.2/AD2P0.3/AD3P0.4/AD4P0.5/AD5P0.6/AD6P0.7/AD7
JS1
0 - 12V, 1A
121
2
R4
10K
R110K
SW1 Reset
C10
10uf
clockchipselect
data
TEMP SENSOR
678 12345Data Pins
LCD_
RS
LCD_
EN
Data
Pins
12V
12
3
10
Zigbee
Data OP
Data IP
HR RATE
RF
Module
-
8/6/2019 Bio Medical Data Reader
11/17
HEART BEAT MODULE :
0
5V
0
5V
U7
LM358
48
5
6
12
3
7
GNDVCC
INB+
INB-
OUTAINA-
INA+
OUTB
C11
100n
D4
LED
R5
330E
R6
100K
1 3
2
R7POT
13
2
R81K
R9
100K
R10
47K
R11
220E
R12
10K
C13
470n
R13
LDR
D5
LED
GND
-
8/6/2019 Bio Medical Data Reader
12/17Title
0
3.3V
0
0
JS1
0 - 12V, 1A
1
21
2
- +
D3
IN4007 x 4
1
2
3
4
C101000mf / 63V
U4 LM317
2
1
3VOUT
ADJ
VIN
R2
220E
R3
1K Preset V
1
3
2
P1
CONNECTOR DB9
5 9 4 8 3 7 2 6 1
U4
MAX232
13
8
11
10
1
3
4
5
2
6
12
9
14
7
16
15
R1IN
R2IN
T1IN
T2IN
C+
C1-
C2+
C2-
V+
V-
R1OUT
R2OUT
T1OUT
T2OUT
VCC
GND
C5
10mf
C4
10mf
C3
10mf
C7
10mf
12V12
3
10
Zigbee
Data O/P
Data I/P
GND
5V
5V
Data O/P
Data I/P
RF
Module
-
8/6/2019 Bio Medical Data Reader
13/17
FUTURE ENHANCEMENTS
In this project we can takes the biological parameters
like heart beat pulse rate and body temperature. In future
enhancement it will develop as a whole body measuringunit. In it body pressure, glucose level and body weight
includes.
-
8/6/2019 Bio Medical Data Reader
14/17
CONCLUSION
The Bio Medical Data Reader will surely relive the staffs
of an Intensive Care unit in a hospital from the strain of
observation of large number of patients up to a good extend.
Any negligence, lack of observation, or misjudgment,
occurring in a manual working condition are completely
eliminated.
The occurrence of a critical condition of any one patient will
be noticed without time.
-
8/6/2019 Bio Medical Data Reader
15/17
BIBLIOGRAPHY
www.atmel.com
www.8052.com
The 8051 Microcontroller and Embedded Systems
By Mazidi and Mazidi
The 8051 Microcontroller Architecture, Programming andApplications-Kenneth J Ayala
-
8/6/2019 Bio Medical Data Reader
16/17
THANKS..
-
8/6/2019 Bio Medical Data Reader
17/17
QUERIES..?