BENCHTOP PROGRAMMER
DRBIII
WINFLASH II
INSTALLATION AND
USER'S GUIDE
September 2003
Ver. 3.0
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
2/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
TABLE OF CONTENTS
HARDWARE INSTALLATION 1
SOFTWARE INSTALLATION 4
OPERATING INSTRUCTIONS 9
MODES OF OPERATION 9
SELECTING THE SERIAL COMMUNICATIONS PORT 10
MODE 1 - OPERATING IN BENCHTOP . 12
Technique 1 - Read Part Number 12
Technique 2 - Specify Model Year, Body and Engine 13
Technique 3 - Specify Part Number 14
Internet Vehicle Controller Flash 16 Finding a Generic Controller Part Number .. 18
Updating the Benchtop Programmer Firmware .. 20
MODE 2 - OPERATING IN DRBIIIWINFLASH .. 21
Establishing communication between DRBIII and PC 21
Technique 1 - Specify Model Year, Body and Engine 22
Technique 2 - Specify Part Number(s) .. 23
Using a PCMCIA Card .. 24
Internet Vehicle Controller Flash 25
ACCESSING INTERNET VEHICLE CONTROLLER FLASH .. 27
APPENDICES . 31
BENCHTOP PROGRAMMER FRONT PANEL INDICATORS .. 31
BENCHTOP PROGRAMMER TROUBLESHOOTING . . 32
TECHNICAL SUPPORT . 33
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
3/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
System Requirements
Before installing the software for the DaimlerChrysler Benchtop Programmer /
DRBIII
WinFlash II, ensure that the personal computer (PC) meets the followingminimum system requirements as well as the operating systems listed.
Hardware:
Intel80486, 66 MHz or higher processor
16 MB of RAM (More memory improves performance)
50-MB available hard disk space
VGA or higher-resolution monitor
16 x CD-ROM drive
Mouse or pointing device
Serial communications port (COM)
Operating System:
Windows 2000 Professional (Administrators group)
Windows XP Professional (Administrators group)
Windows NT 4.0 Workstation
Windows 98
Windows 95
NOTE:
Windows XP Home Edition is not supported.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
4/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Hardware Installation
The Benchtop Programmer Kit contains the following items:
Benchtop Programmer main unit (Part# BTP00001)
DB-9 Null modem cable (Part #DNULL9F9F06)
A power adapter
SBEC control module cable (Part #SBEC018)
JTEC control module cable (Part #JTEC901)
ISIS CD-ROM Software Installation
ISIS Workstation
Benchtop Programmer
DB-9 Cable DB-25 Controller Cables
Vehicle Control ModuleDC Transformer
Benchtop Programmer connection.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
5/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
1. Connect the null modem cable from the back of the Benchtop Programmer main unit (portlabeled RS232) to a serial communication port on the PC.
Benchtop Program15V DC
1 AMP
FUSE
2
RS232
DB9
1 2
2. Connect the DC transformer to a wall outlet and plug it to the back of the BenchtopProgrammer main unit.
3. Connect the appropriate control module cable from the module to be programmed to the frontof the Benchtop Programmer main unit (labeled Controller).
SCI I/II
ISO
CCD
J1850
PWR
STATUS
TXD
RXD
Vehicle Connection
Benchtop Program
3
This completes the hardware setup. If the software has not yet been installed, proceed to the software
installation.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
6/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Software Installation
1. Load the ISIS CD-ROM in the personal computer. Select Run from the Start menu. Select Browse
and then select the CD-ROM drive.
2. Select the Benchtop Programmer folder on the ISIS CD:
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
7/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
3. Within the Benchtop Programmer folder is a file named Setup, select this file to start the
installation of the Benchtop Programmer / DRBIIIWinFlash II application.
The following screen will appear:
NOTE:
If you already have the Benchtop Programmer / DRBIIIWinFlash installed on the PC,
the following message will appear:
Confirm that you would like to continue the upgrade by clicking the OK button.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
8/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
4. Click the Next > button to continue the installation.
5. The installation program will allow you to select the directory where the Benchtop Programmer /
WinFlash II program can be installed. By default, it is installed in the Benchtop Programmer
directory. Click the Next > button to accept the default.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
9/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
6. Click the Next> button to accept the default program folder.
The installation progress bar is shown below:
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
10/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
7. The installation will complete with a dialogue box shown below, or a similar one that will ask to
restart your computer. Click the Finish button to complete the installation.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
11/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Operating InstructionsWhenever operating the Benchtop Programmer / DRBIIIWinFlash II application , the ISIS CD-ROM
must be inserted in the CD-ROM drive. Otherwise, the following message will appear.
Modes of Operation
The Benchtop Programmer / DRBIIIWinFlash has two different operating modesBenchtop andDRB III. The two modes correspond to the hardware device that is connected to the PC to perform the
flash reprogramming operation. To select the mode of operation, click the Mode label from the menu and
clicking --Benchtop Programmer or DRB III WinFlash.
Once the mode is selected, the graphical user interface will change and reflect the hardware device that is
connected to the serial port of the PC.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
12/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Selecting the Serial Communications Port
1. The serial communications port of the PC must be selected when the software is first installed.
To select an alternate port, select Options under the Tools menu.
2. With the Benchtop Programmer or DRB III connected to the PC and powered up, select the serial port
that will be used. Click the Test button.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
13/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
3. The version number of the software and hardware of the main unit and the word Success will
appear when the correct serial port is selected. Click the OK button to save the setting.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
14/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
MODE 1 - OPERATING IN BENCHTOPIn order to program a control module in Benchtop mode, the module must first be connected to the
Benchtop Programmer unit with the correct module cable. Currently there are two cables, one for JTEC
module identified by three connector cavities and the other for SBEC module that has two connectorcavities.
Reprogramming the vehicle control module
There are three different methods of reprogramming the vehicle control module. Each technique is
described in the sections below.
Technique 1 Read Part Number
1. With the control module connected, click the Read PNbutton . The application will display the part
number in the Part Number field.
2. Click the Look-up PN button to display the updates of the controller part number.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
15/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
3. Select the superseding part number in the grid table.
4. Click the Reprogrambutton to update the control module.
Technique 2 Specify Model Year, Body and Engine
1. With the control module connected, select the Model Year, Body and Engine to display the updates of
the controller part number
2. Select the vehicle controller flash in the table grid.
3. Click the Reprogram button to update the control module.
NOTE:
If there are no software updates for the Model Year, Body and Engine combination that have
selected, the following message will appear. Click the Ok button and specify a different
combination.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
16/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Technique 3 Specify Part Number
1. With the control module connected, enter the part number in the Part Number field.
2. Click the Look-up PNbutton to display the updates of the controller part number.
3. Select the superseding part number in the grid table.
4. Click the Reprogrambutton to update the control module.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
17/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
The reprogramming process takes about 3-7 minutes depending on the type of controller and the size of
the flash software. A message and a progress bar will display the reprogramming status.
When the reprogramming sequence is completed, the following message appears.
At this point, the control module has been updated and is ready to be installed in the vehicle.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
18/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Internet Vehicle Controller Flash
Vehicle controller flash can be accessed via the Internet. A user name and password is required to login to
the MDS2002website. A link is provided in the Corporate International Operations Network (CINON)website.
1. Using the Internet, connect to the DaimlerChrysler Corporation, MDS2002 website. Please refer to
page 27 for details.
2. After saving the Internet vehicle controller flash, open the Benchtop Programmer /DRBIIIWinFlash application.
3. Select Benchtop Programmer in the Mode menu.
4. Click the Internet Download button to display all the controller flash updates that were saved
in the C:\ccflash\ccdata folder.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
19/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
5. Select the vehicle controller flash.
6. Click the Download button to reprogram the control module.
7. Click the Exit button to close the Web Download box.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
20/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Finding a Generic Controller Part Number
1. Enter the controller part number or select Model Year, Body and Engine.
2. Select the vehicle controller flash in the table grid.
3. Click the Generic button.
If there is a corresponding generic part number, this will be displayed as shown.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
21/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
NOTE:
Not all part numbers have a generic equivalent. In cases where there is none, a message will be
displayed as shown.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
22/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Updating the Benchtop Programmer Firmware
The software on the Benchtop Programmer main unit is queried by the application when the Read PN or
Program button is selected. The program will compare the firmware version with the latest version that is
on the ISIS CD. In the event that the firmware needs an update, a message will appear as shown.
Click the OK button to perform the firmware update. A progress bar will appear and the firmware of the
main unit will be updated to the latest release. When the update is completed, the following message will
appear.
Click the OK button to return to the Benchtop Programmer application.
NOTE:In the event that the Benchtop Programmer main units STATUS light is illuminated
continuously (not blinking), then the unit needs its firmware to be reprogrammed. Only
when the STATUS is illuminated continuously (not blinking) can you select Update Firmware
from the Tools..
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
23/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
MODE 2 - OPERATING IN DRBIIIWINFLASH IIIn order to operate in DRBIIIWinFlash II mode, the PC and the DRBIII must communicate.
Establishing communication between DRBIII and PC.1. Connect the DRBIII to the PCs serial communications port using the null modem cable.
2. Remove any PCMCIA card from the DRBIII.
3. From the DRBIII Main Menu, select Run Memory Card Program (Option 5).
4. Select Attempt Serial Communication (Option 1) on the next menu. Take no action when the DRBIIIscreen displays, " No Memory Card Detected. Attempt Serial Communications Link. Press Page
Back to Exit."
5. From the computer, open the Benchtop Programmer / DRBIIIWinFlash application.
6. Select DRBIII WinFlash II in the Mode menu. The application should display DRB Connectedin green. The DRB III is now ready to accept files from the PC.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
24/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Reprogramming the vehicle control module
There are two methods of reprogramming the vehicle control module in DRBIIIWinFlash II mode.
Each technique is described in the sections below.
Technique 1 Specify Model Year, Body and Engine
1. With the DRBIII and PC communicating, select the Model Year, Body and Engine to display all
available updates.
2. Select the vehicle controller flash in the table grid.
3. Verify the corresponding Technical Service Bulletin (TSB) number to the selected update.
Additional TSB's are available by clicking the drop down list.
4. Click the CD Download button to send the files to the DRB III.
NOTE:
If there are no software updates for the Model Year, Body and Engine combination that you have
selected, the following message will appear. Click the Ok button and specify a different
combination.:
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
25/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Technique 2 Specify Part Number(s)
1. With the DRBIII and PC communicating, enter the part number(s) in the Part Number field.
2. Click the Look-up PNbutton to display the attributes of the controller part number.
3. Select the superseding part number in the grid table.
4. Verify the corresponding Technical Service Bulletin (TSB) number to the selected update.
Additional TSB's are available by clicking the drop down list.
5. Click the CD Download button to send the files to the DRB III.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
26/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Storing the Vehicle Controller Flash
The vehicle controller flash can be stored to a PCMCIA card (memory card) by changing the DRBIII
drop down list. Otherwise, set the option to default DRB III. The default option will store the files on
the DRB III's internal memory for approximately 8 hours.
Using a PCMCIA Card
1. .Enter the controller part number or select Model Year, Body and Engine.
2. Select the superseding part number or updated vehicle controller flash in the table grid
3. Select SRAM (Static Random Access Memory) or FLASH Card in the drop down list.
4. Select the memory card size. The application tracks the memory size of the flash updates selected.The message 0K of 0K Bytes Used will change as selections are made.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
27/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Internet Vehicle Controller Flash
Vehicle controller flash can be accessed via the Internet. A user name and password is required to login to
the MDS2002 website. A link is provided in the Corporate International Operations Network (CINON)website.
1. Using the Internet, connect to the DaimlerChrysler Corporation, MDS2002 website. Please refer to
page 27 for details.
2. After saving the Internet vehicle controller flash, open the Benchtop Programmer /DRBIIIWinFlash application.
3. Select DRBIIIWinFlash in the Mode menu.
4. Click the Internet Download button to display all the controller flash updates that were saved
in the C:\ccflash\ccdata folder.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
28/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
5. Select the vehicle controller flash.
6. Click the Download button to send the files to the DRB III.
7. Click the Exit button to close the Web Download box.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
29/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Accessing Internet Vehicle Controller Flash
1. Using the Internet, connect to the DaimlerChrysler Corporation, MDS2002 website via the CINON
website: https://extranet6.daimlerchrysler.com/restricted/intnl/ipn/dealerapps.jsp?group=ingso
2. From CINON, select the link, International MDS2002.
3. Enter your User Name and Password.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
30/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
4. Select the option; Click here to enter MS2002.
5. Choose the Year, Model and Engine or enter the vehicle identification number (VIN) in the SelectVehicle tab
6. Click the Submit button to display the entered attributes.
7. Select the Flash tab.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
31/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
8. Select the vehicle controller flash.
9. Two files will be downloaded from the website. The first is of type flbin and the second of type flpart.
Click the Download button to continue.
10. Click the OK button to confirm.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
32/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
11. Choose the option "Save this file to disk" and click the OK button.
12. Save both file types under C:\ccflash\ccdata folder.
13. Click the Close button to complete.
14. Exit from the MS2002 website.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
33/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Appendices
Benchtop Programmer Front Panel Indicators
The front panel is equipped with indicator lights. The operational meanings are given in the table below:
Symbol Meaning Interpretation
SCI I/II DaimlerChrysler Engine
Serial Communications
Interface
When illuminated, the unit is communicating to a
control module using the Serial Communications
Interface Protocol.
ISO International Standards
Organization 9141 Protocol
When illuminated, the unit is communicating to a
control module using the ISO 9141 Protocol.
CCD Chrysler Collision Detection When illuminated, the unit is communicating to a
control module using the Chrysler CollisionDetection Protocol.
J1850 SAE Recommended Standard
J1850 Protocol
When illuminated, the unit is communicating to a
control module using the SAE J1850 Protocol.
PWR Power When illuminated, the unit is powered.
STATUS Status When blinking on and off, the unit is operating
properly in NORMAL mode. When illuminated
solid, the unit is in BOOTSTRAP mode that is
necessary to program the unit.
TXD Transmit Data When illuminated, data is being transmitted to the
PC.
RXD Receive Data When illuminated, data is being received from the
PC.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
34/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Benchtop Programmer Troubleshooting
The following table may be help resolve problems with the operation of the Benchtop Programmer
system or installation.
Symptom Possible Cause(s)
Power light on front panel of main unit will not illuminate Power adapter is notplugged in to an active
outlet
Power adapter is notplugged in to the main unit
Fuse is blown
Cannot establish communications to Benchtop
Programmer main unit from PC Incorrect comm. Port
selected
Null Modem cable not
firmly connected toBenchtop Programmer or
PC
Status light on front panel is illuminated solid (not
blinking)
Benchtop Programmer main unit
firmware needs to be updated or is
being updated
Cannot communicate with vehicle control module. The
following screen may appear:
Cable is not firmly
connected to the controlmodule
Cable is not firmlyconnected to the Benchtop
Programmer main unit.
Defective control module
A previous flash sessionfailed and the Benchtop
Programmer software in
unable to automatically
determine the controller
type.
-
8/10/2019 Benchtop Programmer_ DRBIII Winflash II - User's Guide v3.0.pdf
35/35
BENCHTOP PROGRAMMER / DRB III WINFLASH II
Installation and Users Guide v3.0
Technical Support
For assistance with the Benchtop Programmer / DRBIIIWinFlash II, please contact:
Reymond R. Oyson
DaimlerChrysler Corporation
Dealer Technical Operations
Direct line : (248) 944-2647
Tline: 754-2647
Fax: (248) 944-3081
Email: r r o 5 @dcx.com