Page 1: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

Beam instrumentation and background monitoring

ALICE-LHC Interface: Upgrading for Run 3, 28/06/2019

A. Alici, G. De Cataldo, A. Di Mauro , O. Pinazza, G. Valentino

Page 2: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

Beam instrumentation devices

• Beam Condition Monitor (BCM) → Beam loss/(large)background online monitoring

• Beam Phase and Intensity Monitor (BPIM, readout board of BPTX) → beam clock phase monitoring

Beam instrumentation 2

Page 3: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

• The BCM system consists of two stations of 8 diamond sensors on the A-side and 7 diamond sensors on the C-side

• The BCM readout electronics (CFC card + LHCb TELL1) integrates the signal over three Running Sums: RS1 40 ms, RS2 80 ms and RS32 1.28 ms

• Initiates Beam Dump via BIS if signal is above threshold, delay for complete beam extraction is ~ 250 -290 μs

• Rises Injection Inhibit flag to prevent further injection (and removes it during handshake)

• Beam dump logic:• RS1 or RS2 coincidences:

dump the beam if at least 3 adjacent diamond sensors show a current > thrRS1 or thrRS2 , respectively

• RS32-Sum:Sorting out the two highest and the lowest of 8 sensors, dump the beam if RS32-Sum > thrRS32

• A dynamic threshold system is implemented in order to set high/low value depending on detector status (SAFE/READY) and beam modes:

3

The Beam Condition Monitor system

Beam instrumentation

RUN2 Detectors READY, STABLE BEAM:Low thresholds

Detectors SAFE, .not.STABLE BEAM:High threshold

RS1 500 nA 2700 nA

RS2 250 nA 1350 nA

RS32-Sum 35 nA (1E32 Hz/cm2 ) 300 nA (8.5E32 Hz/cm2 )

Page 4: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

BCM response during RUN-3 equivalent test on 07/09/2018

Beam instrumentation 4

Page 5: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

BCM response during other high-lumi fills

Beam instrumentation 5

Response below 15-20% of dump threshold

Page 6: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

BCM system plans for RUN3

• In principle no changes foreseen on dump threshold. However x-check of max tolerated currents in gaseous detectors

• During LS2 test all sensors to verify noise and gain + check commercial devices in case replacement is necessary

Beam instrumentation 6

Page 7: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

7

BPTX system for LHC clock monitoring

Clock signal transmitted over ~ 14.9 Km of optical fibres at a depth of 1 m from P4 to Prevessin and then to P2

-> clock drift due to temperature variations inducing optical fibers refractive index change (dn/dT1.3x10-5 /oC)

• Estimated max. diurnal drift: 200 ps

• Estimated max. seasonal drift: 8ns

Beam instrumentation

Page 8: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

Phase shift correction in CTP during RUN1 and RUN2

RF RX

RF RX

RF2TTCCORDE

2

Fan-out Fan-out

MAIN_BC

MAIN_ORB

BPIM

BC1

ORBIT1

BC1

BC1

CTP

LTU1

LTU19

ORBIT1

BC1,BC2

2

2

ORB1,ORB2

BC1,BC2afterfine

adjustmentCORDE range:

-5120: +5110 ps(10 ps steps)

Fan-out

2

2

OscilloscopeORBIT1

ORBIT2

BPTXA BPTXC

ORBIT2

8

RF2TTC range:25 ns, 0.5 ns steps

NB: full range exploitation requires

calibrationBeam instrumentation

TTCmi VME crate• Automatically set to 0

by CTP on SQUEEZE;• Manual reset by shift

leader if > 200 ps

Page 9: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

BPTX: summary of clock phase shift in RUN1 and RUN2

Beam instrumentation 9

Wrong phase correction on restart after winter stop

Page 10: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

BPTX: summary of clock phase shift in RUN1 and RUN2

Beam instrumentation 10

Page 11: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

BPIM plans for RUN3

• No changes in HW or SW, under study with LHCb possible alternative to CCPC not supported anymore (however enough spares available)

• Establish procedures for alignment of new CTP and FIT?

Beam instrumentation 11

Page 12: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

Background (beam-gas) monitoring

• During RUN1 and RUN2 based on V0 and AD, respectively

• BKGD publications to LHC during RUN2• BKGD1 is a measure of the beam-gas for beam1 measured by the AD

detector. Units are % normalized to 100kHz.

• BKGD2 is a measure of the beam-gas for beam2 measured by the AD detector. Units are % normalized to 100kHz.

• BKGD3 is given by the 80 μs Running Sum (RS) from the ALICE BCM normalized to the dump threshold. Units are %.

Beam instrumentation 12

Page 13: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

Background (beam-gas) monitoring in RUN3

• In RUN3 entirely new system FIT (including upgraded T0, V0A and AD)

• In principle similar capability/measurements available (to be worked out…)

• New BKGD1 and BKGD2 publications to be discussed (and BKGD4, 5, …)

• Verify RADMONS usage and integrationBeam instrumentation 13

Page 14: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

Back-up slides

Beam instrumentation 14

Page 15: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

15

BPTX/BPIM

Four electrostatic beam pick-ups located at about 146 m from the I.P. on each incoming beam, readout via BPIM (Beam Phase and Intensity Monitor) board.

BPTX_A BPTX_C

Beam-1 Beam-2

IP145.997 m 145.287 m

CTP

BPIM

196.76 m164.89 m

Page 16: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

Seasonal drift

• If T increases, n increases then signal propagation speed decreases and clock front edge is delayed and moves towards bptx bunch signal.

-2

0

2

4

6

8

10

0 5 10 15

ph

ase

[n

s]

Outside temperature [oC]

B1 phase

B2 phase3/3/10

30/3/10

16/4/10

9/5/10

16Beam instrumentation

Page 17: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

ALICE Diffractive detector

Run Condition Meeting, 23th Jun 2016 17

Beam-Gas rate from timing (events in time with the crossing of one beam on both side of the experiment).

AD-C AD-A

tBG < tBB tBG = tBB

Page 18: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

The V0 detector

RCM 14/04/15 18

V0-A

rin=8 cm rout=100 cm

V0-C

rin=8 cm rout= 76 cm

ITS

SPDV0-A

340 cm 90 cm

V0-C

Time spectra allow bkgd rejection(same principle used for new AD detector)

Page 19: Beam instrumentation and background monitoring€¦ · •BKGD1 is a measure of the beam-gas for beam1 measured by the AD detector. Units are % normalized to 100kHz. •BKGD2 is a

V0 timing properties

RCM 14/04/15 19

beam1

IP

340cm~11.3ns

90cm~3ns

V0A V0C

V0A+V0C ≈ 14.3ns

V0A-V0C ≈ 8.3ns

beam1

IP

~-11.3ns ~3ns

V0A+V0C ≈ -8.3ns

V0A-V0C ≈ -14.3ns

beam2

IP

V0A+V0C ≈ 8.3ns

V0A-V0C ≈ 14.3ns

~11.3ns ~-3ns

beam2

collisions

Bkgd1 (BGA)

Bkgd2 (BGC)

Beam background from beam1

Beam background from beam2

satellites