bbgb i&c proposal

10
1 bbgb i&c proposal pawel de barbaro April 25, 2006

Upload: jimbo

Post on 20-Mar-2016

37 views

Category:

Documents


0 download

DESCRIPTION

bbgb i&c proposal. pawel de barbaro April 25, 2006. Rack #9 (done). HV1(hb5-8, hb14-15) HV2(hb16-17, he14-17) HV3 (HO2, 6 RBXes) LV Mainframe 48V service (Delta PS) HV4(HO0, HO1 + 4 spares). Back of HV PS: numbering ?. ch1 ch2 ch3 ch4 ch5 ch6. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: bbgb i&c proposal

1

bbgb i&c proposal

pawel de barbaroApril 25, 2006

Page 2: bbgb i&c proposal

2

Rack #9(done)

HV1(hb5-8, hb14-15)HV2(hb16-17, he14-17)

HV3 (HO2, 6 RBXes)

LV Mainframe

48V service (Delta PS)

HV4(HO0, HO1 + 4 spares)

Page 3: bbgb i&c proposal

3

Back of HV PS: numbering ?

ch1 ch2 ch3 ch4 ch5 ch6

Page 4: bbgb i&c proposal

4

HV power supplies

• HV crate/channel assigment: ch1 ch2 ch3 ch4 ch5 ch6 • Box1: HB05 HB06 HB07 HB08 HB14 HB15• Box2: HB16 HB17 HE14 HE15 HE16 HE17• Box3: HO2_02 HO2_04 HO2_06 HO2_08 HO2_10 HO2_12

• BOX4: HO1_10 HO0_10 spare spare spare spare

Page 5: bbgb i&c proposal

5

proposal Idea: use completely standard blocks of PPs and 9Us,

standard mapping and software.• This way we will debug it and learn how to use it • PP (RM->HTR patch panels) can handle 8

RBXes and feed into 12 HTRs• 9U crates also contain 12HTRs+1 for CU solution:• We have 8 sectors on HBHE + 6 sectors of HO2 • They are partially (‘fully’) loaded because on HE

for upper four sectors• get 3 ‘fully’ loaded PPs• map them into 3 ‘fully’ loaded 9U crate from 904

Page 6: bbgb i&c proposal

6

9U crate in gb. Where are SLB’s?

Page 7: bbgb i&c proposal

7

Standard 904 9U setup is :6HTRs+1, DCC, fanout, 6HTRs+DCC 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 161718 19 20

Em

pty

HTR

0H

TR1

HTR

2H

TR0

HTR

1H

TR2

HTR

-CU

D

CC

Ttc

fano

ut

empt

y

HTR

0H

TR1

HTR

2H

TR0

HTR

1H

TR2

DC

C

HBHE HBHE

we can one-to-one map patch panel organization into 9U organization

Page 8: bbgb i&c proposal

8

New/improved proposal for layout of RBXes in patch panels for gb

HB05 HB06 HB07 HB08

HB14 HE14 HB15 HB15HB16 HE16 HB17 HE17

PP1

PP2

PP3

3 HTRs 3HTRs3 HTRs 3HTRs

3 HTRs 3HTRs3 HTRs 3HTRs

3 HTRs 3HTRs3 HTRs 3HTRs

HO2a HO2b HO2c HO2d

HO2e HO2f HO1 HO0

we can one-to-one map patch panel organization into 9U organization

empt

y

CU

’s

Page 9: bbgb i&c proposal

9

Racks #1 & #2

HBHE 5, 6. 7. 8PP1 and 9U_1

HBHE 14 15 16 17PP2 and 9U_2

HO2 (6RBXes)HO1 (1RBX)HO0 (1RBX)PP3 and 9U_3

1

2

3

1

23

Page 10: bbgb i&c proposal

10

HCAL racks in gb

6U TTC

6U Laser

Rack 1 Rack 2 Rack 9

HV1

HV2

HV3

LV MainFrame

Lambda PS48V service for LV

HV4

HBHE05 HBHE06HBHE07 HBHE08

HBHE14 HBHE15HBHE16 HBHE17HO2a HO2b HO2c HO2dHO2e HO2f HO1 HO0

we can one-to-one map patch panel organization into 9U organization

9U_1

9U_2

9U_3

PP1

PP2

PP3

HBHE 5- 6 7- 82* 6 HTRs + 1(CU)

HBHE14-15 16- 172* 6 HTRs + 1(CU)

HO2,HO1,HO02* 6 HTRs + 1(CU)Enough for 8RBXes