bbg 012 study -echocardiography - onsite evaluations and measurements unenhanced sonovue
TRANSCRIPT
BBG 012
Study -Echocardiography - Onsite Evaluations and Measurements
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
UNENHANCED
Loop Selection fromLoop Selection from MODMOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
SonoVue
CONTENTS
page Loop Selection from MOD - unenhanced
1/2Loop / Page Overview - unenhanced
3
LV-Volumes / EF biplanea4-CV endsyst.
4/5 a4-CV enddiast. 6 a2-CV endsyst. 7 a2-CV enddiast. 8
LV-Volumes / a 3CV monoplanea4-CV endsyst.
9 a4-CV enddiast. 10
Wall Motion Analysis11
EBD / Image Quality12
pageLoop Selection from MOD - SonoVue
13/14Loop / Page Overview - SonoVue 15
LV-Volumes / EF biplanea4-CV endsyst.
16/17 a4-CV enddiast. 18 a2-CV endsyst. 19 a2-CV enddiast. 20
LV-Volumes / a 3CV monoplanea4-CV endsyst.
21 a4-CV enddiast. 22
Wall Motion Analysis 23
EBD / Image Quality 24
Contrast Quality / Artifacts 24
Selection of acquired Loops from MOD (1)Selection of acquired Loops from MOD (1)
Touch 2D, Freeze and touch Loop
1
Touch Delete all pages to empty storage buffer,
2
Touch Disk Retrieve
3
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
1
UNENHANCED
Selection of acquired Loops from MOD (2)Selection of acquired Loops from MOD (2)
Select patient ---N( Native)
(List All Studies) and confirm with o.k.(data loading takes approx. 5 min)
1
Touch Display,touch Preset,
select BBG012 Native
2
Touch Loop, touch Display, You can toggle through the loops/pages by turning the respective knob.
For measurements of biplane EF start with page 1 from 8 (1/8), i.e. apical 4 CV unenhanced
3
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
2
UNENHANCED
Loop/Page Overview Loop/Page Overview - native
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
Page 1 = a 4 CV
Page 2 = a 2 CV
Page 3 = a 3 CV
Page 4 = SAX
Page 5 = Colour Kinesis - a 4 CV
Page 6 = Colour Kinesis - a 2 CV
Page 7 = Colour Kinesis - a 3 CV
Page 8 = Colour Kinesis - SAX
3
UNENHANCED
LV-Volumes and EF biplaneLV-Volumes and EF biplane (LVAs ap 4 - MOD)(LVAs ap 4 - MOD)
Freeze Loop 1/ Page 1
Select a 4CV unenhancedendsystolic frame
(by trackball)
1
Touch Analysis and EF & Volumes
2
Touch EF (MOD-bp) and LVAs ap 4 MOD
3
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV d
4
UNENHANCED
Record all Measurements on SVHS Videotape
LV-Volumes and EF biplane LV-Volumes and EF biplane (LVAs ap 4 - MOD)(LVAs ap 4 - MOD)
.
Move cursor to position at endocardial border of basal septal segment on mitral valve insertion
1
Press Trace2
Press Enter twice 4
Press Erase6
Perform Tracking3
Print Out
(for documentation of LV-Volumes)5
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV d
5
UNENHANCED
LV-Volumes and EF biplaneLV-Volumes and EF biplane (LVAd ap 4 - MOD)(LVAd ap 4 - MOD)
Select enddiastolic frame (by trackball)
1
2 TouchLVAd ap 4 MOD
Move cursor to position at endocardial border of basal septal segment on mitral valve plane.
3
Press Trace4
Press Enter twice 6
Press Erase8
Perform Tracking5
Print Out
(for documentation of LV-Volumes)7
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV d
6
UNENHANCED
LV-Volumes and EF biplaneLV-Volumes and EF biplane (LVAs ap 2 - MOD)(LVAs ap 2 - MOD)
Select endsystolic frame (by trackball)
2
3 Touch LVAs ap 2 MOD
Move cursor to position at endocardial border of basal inferior segment on mitral valve plane.
4
Press Trace5
Press Enter twice
7
Press Erase9
Perform Tracking
6
Print Out
(for documentation of LV-Volumes)8
Touch Loop, touch Display, Go to page 2 from 8 (2/8) (a2CV) 1
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV d
7
UNENHANCED
LV-Volumes and EF biplaneLV-Volumes and EF biplane (LVAd ap 2 - MOD)(LVAd ap 2 - MOD)
3 Move cursor to position at endocardial border of basal inferor segment on mitral valve plane.
5
7
Touch Report + Print Out report
10
Perform Tracking
Print Out
(for documentation of LV-Volumes)8
Deactivate Results Box 6
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV d
Insert derived volumes (--> see print outs) / EF (--> see report) from biplane and monoplane a4CV measurements into CRF-Page 15
8
UNENHANCED
Select enddiasstolic frame (by trackball)
1
Touch LVAd ap 2 MOD
Press Trace4
Press Enter twice
9
2
LV-Volumes and EF monoplane a3CVLV-Volumes and EF monoplane a3CV (LVAs ap 4 - MOD)(LVAs ap 4 - MOD)
3
Press Trace and Perform Tracking7
Press Enter twice 8 Press Erase
Touch Loop, touch Display, Go to page 3 from 8 (3/8) (a3CV)
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV d a3CV sa3CV sa3CV da3CV d
4
Touch EF (MOD-bp) and LVAs ap 4 MOD
Move cursor to position at endocardial border of basal posterior segment on mitral valve plane.
Select endsystolic frame (by trackball)
2
Touch Analysis and EF & Volumes
Touch Erase All and confirm with Enter
1
5
9
UNENHANCED
6
11
Print Out
(for documentation of LV-Volumes)10
LV-Volumes and EF monoplane a3CVLV-Volumes and EF monoplane a3CV (LVAd ap 4 - MOD)(LVAd ap 4 - MOD)
Select enddiasstolic frame (by trackball)
1
3
Touch LVAd ap 4 MOD
Move cursor to position at endocardial border of basal inferior segment on mitral valve plane.
Press Trace4
Press Enter twice 7
Touch Report + Print out Report9
Perform Tracking5
Print Out
(for documentation of LV-Volumes)8
2
Deactivate Results Box 6
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV d
Insert derived volumes (--> see print outs) / EF (--> see report) from monoplane a3CV measurements into CRF-Page 15
10
10
UNENHANCED
Wall Motion AnalysisWall Motion Analysis
Perform segmental WMA (16 segment model).
CK (loops 5-8) may be used as additive information
2
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
Touch Loop,touch Display,You can toggle through the loops/pages by turning the respective knob.
1
11
UNENHANCED
Endocardial Border DelineationEndocardial Border Delineation
Perform segmental EBD (16 segment model).
2
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob.
1
12
UNENHANCED
Image QualityImage Quality
Assess overall image quality according to the score given on page 15 of the CRF
2
Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob.
1
Selection of acquired Loops from MOD (1)Selection of acquired Loops from MOD (1)
Touch 2D, Freeze and touch Loop
1
Touch Delete all pages to empty storage buffer,
2
Touch Disk Retrieve
3
13
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
SonoVue
Selection of acquired Loops from MOD (2)Selection of acquired Loops from MOD (2)
Select patient ---S ( SonoVue)
(List All Studies) and confirm with o.k.(data loading takes approx. 5 min)
1
Touch Display,touch Preset,
select BBG012 SonoVue
2
Touch Loop, touch Display, You can toggle through the loops/pages by turning the respective knob.
For measurements of biplane EF start with page 1 from 8 (1/8), i.e. apical 4 CV SonoVue
3
14
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
SonoVue
Loop Overview Loop Overview - SonoVue
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
Page 1 = a 4 CV
Page 2 = a 2 CV
Page 3 = a 3 CV
Page 4 = SAX
Page 5 = Colour Kinesis - a 4 CV
Page 6 = Colour Kinesis - a 2 CV
Page 7 = Colour Kinesis - a 3 CV
Page 8 = Colour Kinesis - SAX
15
SonoVue
LV-Volumes and EF biplaneLV-Volumes and EF biplane (LVAs ap 4 - MOD)(LVAs ap 4 - MOD)
Freeze Loop 1/ Page 1
Select a 4CV unenhancedendsystolic frame
(by trackball)
1
Touch Analysis and EF & Volumes
2
Touch EF (MOD-bp) and LVAs ap 4 MOD
3
16
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV dSonoVue
Record all Measurements on SVHS Videotape
LV-Volumes and EF biplane LV-Volumes and EF biplane (LVAs ap 4 - MOD)(LVAs ap 4 - MOD)
.
Move cursor to position at endocardial border of basal septal segment on mitral valve insertion
1
Press Trace2
Press Enter twice 4
Press Erase6
Perform Tracking3
Print Out
(for documentation of LV-Volumes)5
17
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV dSonoVue
LV-Volumes and EF biplaneLV-Volumes and EF biplane (LVAd ap 4 - MOD)(LVAd ap 4 - MOD)
Select enddiastolic frame (by trackball)
1
2 TouchLVAd ap 4 MOD
Move cursor to position at endocardial border of basal septal segment on mitral valve plane.
3
Press Trace4
Press Enter twice 6
Press Erase8
Perform Tracking5
Print Out
(for documentation of LV-Volumes)7
18
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV dSonoVue
LV-Volumes and EF biplaneLV-Volumes and EF biplane (LVAs ap 2 - MOD)(LVAs ap 2 - MOD)
Select endsystolic frame (by trackball)
2
3 Touch LVAs ap 2 MOD
Move cursor to position at endocardial border of basal inferior segment on mitral valve plane.
4
Press Trace5
Press Enter twice
7
Press Erase9
Perform Tracking
6
Print Out
(for documentation of LV-Volumes)8
Touch Loop, touch Display, Go to page 2 from 8 (2/8) (a2CV) 1
19
UNENHANCED
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV dSonoVue
LV-Volumes and EF biplaneLV-Volumes and EF biplane (LVAd ap 2 - MOD)(LVAd ap 2 - MOD)
3 Move cursor to position at endocardial border of basal inferor segment on mitral valve plane.
5
7
Touch Report + Print Out report
10
Perform Tracking
Print Out
(for documentation of LV-Volumes)8
Deactivate Results Box 6
Insert derived volumes (--> see print outs) / EF (--> see report) from biplane and monoplane a4CV measurements into CRF-Page 18
20
Select enddiasstolic frame (by trackball)
1
Touch LVAd ap 2 MOD
Press Trace4
Press Enter twice
9
2
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV dSonoVue
LV-Volumes and EF monoplane a3CVLV-Volumes and EF monoplane a3CV (LVAs ap 4 - MOD)(LVAs ap 4 - MOD)
3
Press Trace and Perform Tracking7
Press Enter twice 8 Press Erase
Touch Loop, touch Display, Go to page 3 from 8 (3/8) (a3CV)
4
Touch EF (MOD-bp) and LVAs ap 4 MOD
Move cursor to position at endocardial border of basal posterior segment on mitral valve plane.
Select endsystolic frame (by trackball)
2
Touch Analysis and EF & Volumes
Touch Erase All and confirm with Enter
1
5
21
6
11
Print Out
(for documentation of LV-Volumes)10
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV d a3CV sa3CV sa3CV da3CV dSonoVue
LV-Volumes and EF monoplane a3CVLV-Volumes and EF monoplane a3CV (LVAd ap 4 - MOD)(LVAd ap 4 - MOD)
Select enddiasstolic frame (by trackball)
1
3
Touch LVAd ap 4 MOD
Move cursor to position at endocardial border of basal inferior segment on mitral valve plane.
Press Trace4
Press Enter twice 7
Touch Report + Print out Report9
Perform Tracking5
Print Out
(for documentation of LV-Volumes)8
2
Deactivate Results Box 6
Insert derived volumes (--> see print outs) / EF (--> see report) from monoplane a3CV measurements into CRF-Page 18
10
22
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
a 4CV sa 4CV sa4CV da4CV da2CV sa2CV sa2CV da2CV da3CV sa3CV sa3CV da3CV dSonoVue
Wall Motion AnalysisWall Motion Analysis
Perform segmental WMA (16 segment model).
CK loops 5-8) may be used as additive information
2
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA
Touch Loop,touch Display, You can toggle through the loops/pages by turning the respective knob.
1
ArtifactsArtifacts
23
SonoVue
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA ArtifactsArtifacts
24
SonoVue
Endocardial Border DelineationEndocardial Border Delineation Image Quality Image Quality
Perform segmental EBD (16 segment model).
2
Touch Loop,touch Display,You can toggle through the loops/pages by turning the respective knob.
1
Assess overall image quality according to the score given on page 15 of the CRF
2
Touch Loop,touch Display,You can toggle through the loops/pages by turning the respective knob.
1
Contrast Quality - ArtifactsContrast Quality - Artifacts
Assess contrast artifacts according to the score on page 18 of the CRF
2
Touch Loop,touch Display,You can toggle through the loops/pages by turning the respective knob.
1
Loop Selection from MODLoop Selection from MOD EF biplaneEF biplane EF a 3CVEF a 3CV Image QualityImage QualityEBDEBDWMAWMA ArtifactsArtifacts
25
SonoVue