Agenda
● Autonomous Charging with PM8058● Charging Control● Known Issues● Q & A
Autonomous Charging with PM8058
Autonomous Charging
● This is a new feature supported by PM8058.● With autonomous charging, the PMIC is able to control
charging without software intervention.● The autonomous charging algorithm is implemented in a
state machine; once it begins, it executes a sequence of predetermined states until charging is completed.
Select Appropriate Power Source for VDD
● Battery Power – A charger is not present.– or an invalid charger is present. (VCHG is below 3.3V or above 7V)– or valid charger is present but it is an intelligent USB device and
the battery is not severely depleted.● External Charger Power
– A regular charger (not an intelligent USB device) is present and valid.
– or an intelligent USB charger is present and valid, but battery is severely depleted and the LOW_CURR_BOOT register bit is set to 1. (meaning that the PMIC can perform a low current boot)
● Auto-trickle Charging– An intelligent USB charging device is present.– and the battery is severely depleted.– and the LOW_CURR_BOOT register bit is set to 0.
Charging Control
Register Battery Client to Modem
BATTERY_VOLTAGE_UPBATTERY_VOLTAGE_DOWNBATTERY_VOLTAGE_ABOVE_THIS_LEVELBATTERY_VOLTAGE_BELOW_THIS_LEVELBATTERY_VOLTAGE_LEVELBATTERY_ALL_ACTIVITYVBATT_CHG_EVENTSBATTERY_VOLTAGE_UNKNOWN
Get Battery and Charger status
Charging Control
Light Up Charging LED
Charging LED Behavior
● Framework has its charging LED behavior.● Charger Presence
– Battery Capacity < 10%: Red Solid LED– 90% > Battery Capacity > 10 %: Red + Green Solid
LED– Battery Capacity > 90%: Green Solid LED
● No Charger Presence– Battery Capacity < 10%: Red Blink LED
Known Issues
Charging Notification Delay
● QA expectation: DUT should show charging notification , charging LED, charging icon or charging splash images, immediately when insert AC/USB cable into DUT.
● Root Cause:- Different HW Design
- Before FB0: An external charging IC is adopted.- Charging LED can be lit up immediately once the USB/AC
cable insert into DUT.- FB0: Use PM8058 autonomous charging.
- Different SW Architecture- Before FB0: Host can control charging IC directly.
- RPC calls are not necessary. - UEvent can be sent as early as possible once the charging
configuration is finished.- FB0: Host have to notify Modem to turn on charging by RPC calls.
Charging Notification Delay(cont.)
• Possible Solutions– Charging LED Improvement:
1. Modify HW layout to let charging LED be lit up by HW first.
2. Light up charging LED by Modem tasks first.3. Light up charging LED once the USB/AC cable
insertion event has been received by USB driver.– Charging Icon Improvement:
• Trigger UEvent once the USB/AC cable insertion event has been received by USB driver.
Removed Battery Intentionally
● DUT will not shutdown when removing battery with AC/USB cable plugged
● Root Cause:– Modem should notify Host immediately when battery is
removed.● Solutions:
– in OS Mode● Modem notify Host by RPC callback.
– in Power-Off Charging Mode● Modem have to provide a shared memory command
for Host to check battery status in LK.
Modem BATT/CHG Events
● As mentioned in Page 9, Modem will send BATT/CHG event once battery voltage changes or charger status changes if our battery registers a battery client to Modem.– The battery event is sent when battery voltage has a
100mV variation.● This event is very difficult to observe.● FB0 has gauge IC. ● The battery status updates by polling in current battery
driver.– The charger event is sent when the charger is inserted or
removed.– And so on……
Unconfigured Current (USBIF)
● USB device cannot draw 500mA current before it is configured.
● Unconfigured current is 100mA● Solution: Set charging current to 100mA when USB device
is in SET_ADDRESS_STATE.
Q & A