base 8 40/100g equipment cords - the siemon...
TRANSCRIPT
MTP Connector Gender Options for both male or female
Small Diameter 2mm RazorCore fiber cableimproves cable managementand pathway fill.
Jacket ratings Available in Plenum,Riser and LSOH
BASE 8 40/100G Equipment Cords
Slemon's Base 8 MTP PRO jumpers are used to connect the MTP trunk backbone to the active equipment. The 8-fiber design ensures 100% utilization of fiber in 8-fiber 40/100G applications, while the compact design of the MTPfootprint and Siemon's 2mm diameter RazorCore™ cable achieves greater connectivity access, reduction Incable pathway congestion and improved airflow.
BASE 8 MTP PRO 2mm Jumpers
Tx Tx Tx Tx Rx Rx Rx Rx
40GBASE-SR4 8-Fiber and 100GBASE-SR4 8-Fiber MTP(1) 8 strand MTP trunk is used for one link
• Active equipment has a male MTP/MPO connector• All assemblies are B-polarity (straight-through wiring)• MTP adapter plate has aligned key orientation• The trunk is male-to-male (in contrast to typical 10G cassette-based MTP channels where the trunk is female-to-female)
Easy Identification Base 8 assemblies feature a blue boot to easilydistinguish from Base 12 assemblies
MTP Adapter Plate with Aligned Key MTP Adapter Plate with Aligned Key
Part # GJSPLPFF-(XXX)M-B
Polarity B
Female to Female
Polarity B
Male to Male
Polarity B
Female to Female
Part # GR8M5LP(XXX)M-B
Example Channel Model
40G ChannelBackbone Fiber Trunk
Part # GJSPLPFF-(XXX)M-B
Multiple Fiber TypesAvailable in Multimode (laser optimizedOM3 and OM4) and Singlemode
MTP PRO ConnectorThe MTP Pro option enables quickand easy polarity and pin changesin the field using an innovativehand-held tool.
SS_BASE8_40_100G_MJS_Cords_F.qxp_F 1/6/20 4:37 PM Page 1
10G CASSETTE-BASED CHANNEL MIGRATION TO BASE 8 10/100G
Polarity C
Female to Female
10G Channel
Cassettes and LCjumpers removed
Part # GR8-5LP(XXX)M-CExample Channel Model
Existing Backbone Fiber Trunk
Cassettes and LCjumpers removed
Base 8 40G Channel
Polarity B
Female to Male
Polarity C
Male to Female
MTP jumpers added
Example Channel Model
MTP jumpers added
Existing Backbone Fiber Trunk
MTP Adapter Plate with Opposing Key MTP Adapter Plate with Opposing Key
Part # GJSPLPMF-(XXX)M-BPart # GJSPLPMF-(XXX)M-C
Polarity C
Female to Female
Part # GR8-5LP(XXX)M-C
SS_BASE8_40_100G_MJS_Cords_F.qxp_F 1/6/20 4:37 PM Page 2
Ordering Information40/100G EQUIPMENT CORDS
GJ(X)P(X)(X)(X)(X)-(XXX)(X)-(X) . . . .Base 8 MTP PRO 2mm (0.079 in.) jumper
S = Standard LossL = Low Loss (OM3/OM4 only)
Performance
Fibre Type
Jacket RatingP = PlenumR = RiserL = LSOH
Side A M = MaleF = Female
Side B M = MaleF = Female
Length UnitF = FeetM = Metre
Length
A = Method AB = Method BC = Method C
Polarity Method
L = OM3, XGLO 300 50/125 Multimode AquaV = OM4, XGLO 550 50/125 Multimode AquaE = OM4, XGLO 550 50/125 Multimode Erika VioletA = OS1/OS2, Singlemode Yellow
Length must be 3 digitsExample:003 = 3m010 = 10 ft.
MTP PRO Activation Tool and PIN ExchangersOrdering Information:
Part # Description
FT-MP-AT . . . . . . . . . . . . . . .Field Termination, MTP PRO, Activation Tool
FT-MP-PE-SME . . . . . . . . . .Field Termination, MTP PRO, Pin Exchanger with SM Elite Pins
FT-MP-PE-MME . . . . . . . . . .Field Termination, MTP PRO, Pin Exchanger with MM Elite Pins
SS_BASE8_40_100G_MJS_Cords_F.qxp_F 1/6/20 4:37 PM Page 3
SS_B
ASE
_8_M
TP_2
mm
_Jum
pers
_F
1/2
0©
202
0 Si
emon
Because we continuously improve our products, Siemon reserves the right to change specifications and availability without prior notice.
Worldwide Headquarters North AmericaWatertown, CT USA
Phone (1) 860 945 4200
Regional Headquarters Europe Russia AfricaChertsy, Surrey, England
Phone (44 ) 0 1932 571771
Regional Headquarters ChinaShanghai, P.R. China
Phone (86) 215385 0303
Regional Headquarters Latin America Bogota, Colombia
Phone (571) 657 1950/51/52
Regional Headquarters India Middle EastDubai, United Arab Emirates
Phone (971) 4 3689743
Siemon Interconnect SolutionsWatertown, CT USAPhone (1) 860 945 4213 US
www.siemon.com/SIS
Regional HeadquartersAsia PacificSydney, Australia
Phone (86) 21 5385 0303
STANDARD LOSS ASSEMBLIES
Fiber Cable Attenuation, MAX (dB/km) 3.0/1.0 3.0/1.0 0.4/0.4/0.3*
LED Bandwidth, MIN (MHz/km) 1500/500 3500/500 N/A
Effective Modal Bandwidth, MIN (MHz/km) 2000 4700 N/A
Cable Outer Jacket, Color (Per TIA-598-D) Aqua Aqua Yellow
XGLO
50/125 OM3
(850/1300nm)
XGLO
50/125 OM4
(850/1300nm)
Multimode
CABLE - OPTICAL AND PHYSICAL SPECIFICATIONS
CONNECTORS - PHYSICAL SPECIFICATIONS
Product Specifications
Cable Type
Fiber Type
MAX Insertion(dB)
MAX Return Loss(dB) Performance Class
MTP LC MTP LC
5L-MM50/125(OM3) 0.50 0.25 20 30 XGLO® 300
5V-MM50/125(OM4) 0.50 0.25 20 30 XGLO 550
SM-LWP SM (OS1/OS2) 0.60 0.40 65 55 XGLO
Fiber Type
MAX Insertion(dB)
MAX Return Loss(dB) Performance Class
MTP LC MTP LC
5L-MM50/125(OM3) 0.20 0.15 20 30 XGLO 300
5V-MM50/125(OM4) 0.20 0.15 20 30 XGLO 550
LOW LOSS ASSEMBLIES
Singlemode
* XGLO singlemode fiber meets low water peak specifications per ITU-TG.652.C
Connector TypeIEC IntermateabilityCompliance
TIA IntermateabilityCompliance
8-Fiber MTP IEC 61754-7 TIA/EIA-604-5MM SM MM 5MAqua Green Blue Blue
Housing Color Boot Color