bare 4255 - eurekalighting.com · bare 4255-ufl stem or cable options options de tige ou cable...

10
Bare 4255

Upload: hoanganh

Post on 09-Sep-2018

219 views

Category:

Documents


0 download

TRANSCRIPT

Bare 4255

PENDANT, hand blown crystal glass exterior, inner spunaluminum reflector Glare-free design, direct and indirectlight distribution Wide range of light sources available such as energy efficient LED light sources

Eureka Lighting © 2017 www.eurekalighting.com V2.0-201706

PROJECT PROJET

SPEC TYPE

NOTES

SPECIFICATION

BARE 4255-UFL

STEM OR CABLE OPTIONS OPTIONS DE TIGE OU CABLE

4255-UFL

MOUNTING OPTIONS OPTIONS DE MONTAGE

OVERALL HEIGHT HAUTEUR HORS TOUT

AC CABLESTD 60”1523mm

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

MOUNTING OPTIONS EPS

2402JØ5.25” x 2.25”Ø133 x 57mm

2402GØ5.25” x 1.75”Ø133 x 44mm

2734F7.25” x 1.70”37 x 35mm

2403GØ4.50” x 1.50”Ø114 x 38mm

2401EØ4.50” x 1.00”Ø114 x 25mm

2734B1.46” x 1.36”37 x 35mm * OVERALL HEIGHT DOES NOT INCLUDE TRACK THICKNESS

LIGHT SOURCE

MOUNTING

CABLE

CFL

2402G

70.45”

INC

2401E

69.70”

CFL DIM

2402J

46.95”

LED TRACK1 CIRCUIT

2734F

70.45”

INC TRACKI CIRCUIT

2734B

68.80”

LED DIM-8W 277V

2403G

70.20”

ORDERING SPECIFICATION SPÉCIFICATION DE COMMANDE CODE

MODEL MODÈLE 4255-UFL

4255-UFL BARE

LIGHT SOURCE SOURCE LUMINEUSE

(WATTAGE, LAMP TYPE, LAMP FORM, BASE TYPE, OTHER INFO)

CF.D.13*CF.D.18*CF.T.32*INC.100LED.4LED.8LED.18

13W, CFL, DOUBLE TWIN TUBE, G24Q1 BASE18W, CFL, DOUBLE TWIN TUBE, G24Q2 BASE26/32W, CFL, TRIPLE TWIN TUBE, G24Q3 BASE100W, INC, A19 / HAL T10, MEDIUM BASE (120V ONLY)4W, LED8W, LED18W, LED*NOT AVAILABLE WITH A TRACK ADAPTOR

COLOR TEMPERATURE TEMPÉRATURE DE COULEUR

FOR LED ONLY

303540

3000K3500K4000K

VOLTAGE VOLTAGE

120V277V*347V**

120 VOLT277 VOLT347 VOLT*NOT AVAILABLE WITH A TRACK ADAPTOR**ONLY AVAILABLE WITH CF.D.13, CF.D.18 & CF.T.32 (NON-DIMMING BALLAST)

DIMMING OPTION OPTION DE GRADATION

AVAILABLE WITH CF.D.18 & CF.T.32MAXIMUM 36" AIRCRAFT CABLE LENGTH

DEDDE3

LUTRON ECOSYSTEM ELECTRONIC DIMMING BALLAST (ECOSYSTEM DIGITAL LINK WIRING)LUTRON ECOSYSTEM ELECTRONIC DIMMING BALLAST (3-WIRE WIRING)

FOR LED ONLY

DV*DP

0-10V DIMMING (120-277V)PHASE DIMMING (120V ONLY)LED DIMMING DRIVER IS STANDARD FOR LED.18, PLEASE SPECIFY YOUR DIMMING TYPE.*NOT AVAILABLE WITH A TRACK ADAPTOR

CABLE CABLE AC

AC AIRCRAFT MOUNTING & CLEAR CABLE, FIELD ADJUSTABLE

CABLE LENGTH LONGUEUR DE CABLE

60**

60" AIRCRAFT CABLE (STD LENGTH)CUSTOM AIRCRAFT CABLE LENGTH (PLEASE SPECIFY)FOR OVERALL LENGTH PLEASE CONTACT YOUR EUREKA REPRESENTATIVE.

MOUNTING MONTAGE

RC

TA1

ROUND CANOPY / PAVILLON RONDFOR LED 18W: 0.50" CANOPY (2401C)FOR INC & LED 4W AND 8W 120V: 1.00" CANOPY (2401E)FOR DIMMING LED 4W AND 8W & LED 8W 277V: 1.75" CANOPY (2403G)FOR CFL: 1.75" CANOPY (2402G)FOR DIMMING CFL: 2.25" CANOPY (2402J)

TRACK ADAPTOR / ADAPTATEUR DE RAIL1 CIRCUITINC, LED NON-DIMMING (4W & 8W) & LED (18W) 120V ADAPTOR (2734B)LED DIMMING (4W & 8W) 120V ADAPTOR (2734F)

TRACK ADAPTOR FINISH FINI ADAPTATEUR DE RAIL (A)

WHBLKM G

WHITEBLACKMETALLIC GRAY(A) FILL IN IF A TRACK ADAPTOR IS SELECTED, OTHERWISE LEAVE EMPTY

STRUCTURE FINISH FINI STRUCTURE (B)

CHRWH

CHROMEWHITEINTERNAL PARABOLIC REFLECTOR SUPPLIED AS WHITE ONLY.(B) INCLUDE CANOPY FINISH IF CANOPY IS SELECTED

DIFFUSER FINISH FINI DIFFUSEUR CFR

CFR CLEAR / FROSTED

PRODUCT CHARACTERISTICS CARACTÉRISTIQUES DU PRODUIT

DESIGN: Organic glass pendant with frosted diffusing lamp and parabolic interior reflector.LIGHT SOURCE: LED as well as many other dimmable fluorescent and incandescent sources.DIFFUSER: Hand blown clear glass with precisely aligned frosted section.STRUCTURE: Die-formed steel canopy, fittings and interior reflector with white polyester powder coating.CERTIFIED: c-CSA-us

SPECIFICATIONS LED 4WLIGHT SOURCEDELIVERED LUMENSCRIDRIVERDIMMING

84 CRI (Typical)CC 350mAPhase dimming (DP) or 0-10V dimming (DV)

WARRANTYLM-79 On request

5 years

BALANCING THE FIXTURE

LED 8W

CC 700mA

LED 18W1x COB LED (total 18W)1429lm (4000K)

CC 500mA

On request

SPECIFICATIONS COMPACT FLUO G24QLIGHT SOURCEDIMMINGVOLTAGE

13W, 18W, 26/32WAdvance Mark 7&10, Lutron EcoSystem120-277V, 347V (non-dimming)

COMPACT FLUO GU24Spiral 26W self ballastedDimmable light bulb only120V

INCANDESCENTA19, T10 100WAlways120V

PARABOLIC REFLECTORWhite powder coated spun

16Ga aluminium sheet

HAND BLOWN CRYSTAL GLASSClear top section for optimized

indirect lighting

4&8W LED VERSIONSMachined aluminium heatsink

with integrated driver

18W LED VERSIONS (HO)LED COB with high efficiency spherical diffuser

FROST BOTTOM SECTIONSandblasted to protect

from the glare

SINGLE AIRCRAFT CABLEAdjustable on site

4255-UCR (SKIRT)4255-UFL (BARE)

4255-UFL

V4.0-201806www.eurekalighting.comEureka Lighting©2017

ANATOMY BARE

225 de Liège Ouest, Suite #200 Montréal (QC), Canada H2P 1H4 Tel : 514.385.3515 Fax : 514.385.4169 www.eurekalighting.com

4x high power LED (total 4.7W)478lm (4000K)

4x high power LED (total 9.8W)875lm (4000K)

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

Anatomy

SPECIFICATIONS LED 4WLIGHT SOURCEDELIVERED LUMENSCRIDRIVERDIMMING

84 CRI (Typical)CC 350mAPhase dimming (DP) or 0-10V dimming (DV)

WARRANTYLM-79 On request

5 years

BALANCING THE FIXTURE

LED 8W

CC 700mA

LED 18W1x COB LED (total 18W)1429lm (4000K)

CC 500mA

On request

SPECIFICATIONS COMPACT FLUO G24QLIGHT SOURCEDIMMINGVOLTAGE

13W, 18W, 26/32WAdvance Mark 7&10, Lutron EcoSystem120-277V, 347V (non-dimming)

COMPACT FLUO GU24Spiral 26W self ballastedDimmable light bulb only120V

INCANDESCENTA19, T10 100WAlways120V

PARABOLIC REFLECTORWhite powder coated spun

16Ga aluminium sheet

HAND BLOWN CRYSTAL GLASSClear top section for optimized

indirect lighting

4&8W LED VERSIONSMachined aluminium heatsink

with integrated driver

18W LED VERSIONS (HO)LED COB with high efficiency spherical diffuser

FROST BOTTOM SECTIONSandblasted to protect

from the glare

SINGLE AIRCRAFT CABLEAdjustable on site

4255-UCR (SKIRT)4255-UFL (BARE)

4255-UFL

V4.0-201806www.eurekalighting.comEureka Lighting©2017

ANATOMY BARE

225 de Liège Ouest, Suite #200 Montréal (QC), Canada H2P 1H4 Tel : 514.385.3515 Fax : 514.385.4169 www.eurekalighting.com

4x high power LED (total 4.7W)478lm (4000K)

4x high power LED (total 9.8W)875lm (4000K)

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

SPECIFICATIONS LED 4WLIGHT SOURCEDELIVERED LUMENSCRIDRIVERDIMMING

84 CRI (Typical)CC 350mAPhase dimming (DP) or 0-10V dimming (DV)

WARRANTYLM-79 On request

5 years

BALANCING THE FIXTURE

LED 8W

CC 700mA

LED 18W1x COB LED (total 18W)1429lm (4000K)

CC 500mA

On request

SPECIFICATIONS COMPACT FLUO G24QLIGHT SOURCEDIMMINGVOLTAGE

13W, 18W, 26/32WAdvance Mark 7&10, Lutron EcoSystem120-277V, 347V (non-dimming)

COMPACT FLUO GU24Spiral 26W self ballastedDimmable light bulb only120V

INCANDESCENTA19, T10 100WAlways120V

PARABOLIC REFLECTORWhite powder coated spun

16Ga aluminium sheet

HAND BLOWN CRYSTAL GLASSClear top section for optimized

indirect lighting

4&8W LED VERSIONSMachined aluminium heatsink

with integrated driver

18W LED VERSIONS (HO)LED COB with high efficiency spherical diffuser

FROST BOTTOM SECTIONSandblasted to protect

from the glare

SINGLE AIRCRAFT CABLEAdjustable on site

4255-UCR (SKIRT)4255-UFL (BARE)

4255-UFL

V4.0-201806www.eurekalighting.comEureka Lighting©2017

ANATOMY BARE

225 de Liège Ouest, Suite #200 Montréal (QC), Canada H2P 1H4 Tel : 514.385.3515 Fax : 514.385.4169 www.eurekalighting.com

4x high power LED (total 4.7W)478lm (4000K)

4x high power LED (total 9.8W)875lm (4000K)

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

Number of lamps: Lumens per lamp:Input watts:Distribution:Efficiency:Photometric type:

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

11800

30Direct-Indirect

95.1C

RectangleFeet

0.9680.9680.886

2.402.402.40

© 2011 EUREKA LIGHTINGwww.eurekalighting.com

4255-UFL-CFT26-CFR-WHOne 26W Compact Fluorescent Triple Twin Tube

Bare

Photometric Report anglescd180 170 160 150 140 130

0 10 20 30 40 50

60

70

80

90

100

110

0

19

19

37

37

56

56

75

75

93

112

131

120

V1.0-201111

Photometric Report

Number of lamps: Lumens per lamp:Input watts:Distribution:Efficiency:Photometric type:

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

11800

30Direct-Indirect

95.1C

RectangleFeet

0.9680.9680.886

2.402.402.40

© 2011 EUREKA LIGHTINGwww.eurekalighting.com

4255-UFL-CFT26-CFR-WHOne 26W Compact Fluorescent Triple Twin Tube

Bare

Photometric Report anglescd180 170 160 150 140 130

0 10 20 30 40 50

60

70

80

90

100

110

0

19

19

37

37

56

56

75

75

93

112

131

120V1.0-201111

Number of lamps: Lumens per lamp:Input watts:Distribution:Efficiency:Photometric type:

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

11800

30Direct-Indirect

95.1C

RectangleFeet

0.9680.9680.886

2.402.402.40

© 2011 EUREKA LIGHTINGwww.eurekalighting.com

4255-UFL-CFT26-CFR-WHOne 26W Compact Fluorescent Triple Twin Tube

Bare

Photometric Report anglescd180 170 160 150 140 130

0 10 20 30 40 50

60

70

80

90

100

110

0

19

19

37

37

56

56

75

75

93

112

131

120

V1.0-201111

Number of lamps: Lumens per lamp:Input watts:Distribution:Efficiency:Photometric type:

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

11690

100Direct-Indirect

94.1C

RectangleFeet

0.9680.9680.886

1.721.721.89

© 2011 EUREKA LIGHTINGwww.eurekalighting.com

4255-UFL-INC100-CFR-WHOne 100W Incandescent A19 Medium Base

Bare

Photometric Report anglescd

0 10 20 30 40

50

60

70

80

90

100

110

120

0

17

17

34

34

50

50

67

67

84

84

101

117

134

180 170 160 150 140 130

V1.0-201111

Number of lamps: Lumens per lamp:Input watts:Distribution:Efficiency:Photometric type:

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

11690

100Direct-Indirect

94.1C

RectangleFeet

0.9680.9680.886

1.721.721.89

© 2011 EUREKA LIGHTINGwww.eurekalighting.com

4255-UFL-INC100-CFR-WHOne 100W Incandescent A19 Medium Base

Bare

Photometric Report anglescd

0 10 20 30 40

50

60

70

80

90

100

110

120

0

17

17

34

34

50

50

67

67

84

84

101

117

134

180 170 160 150 140 130

V1.0-201111

Number of lamps: Lumens per lamp:Input watts:Distribution:Efficiency:Photometric type:

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

11690

100Direct-Indirect

94.1C

RectangleFeet

0.9680.9680.886

1.721.721.89

© 2011 EUREKA LIGHTINGwww.eurekalighting.com

4255-UFL-INC100-CFR-WHOne 100W Incandescent A19 Medium Base

Bare

Photometric Report anglescd

0 10 20 30 40

50

60

70

80

90

100

110

120

0

17

17

34

34

50

50

67

67

84

84

101

117

134

180 170 160 150 140 130

V1.0-201111

BARE 4W

PHOTOMETRIC REPORT 4255-UFL-LED 4W 17

V1.1-201805www.eurekalighting.comEureka Lighting©2018

CCT (K):Delivered Lumens (lm):System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40004773.8Direct126C

Rectanglein (mm)10.8 (274.32)10.8 (274.32)10.8 (274.32)

0.290.290.27

4255-UFL-LED 4W 17˚

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

0 - 180

anglescd

0 - 90

0

10

20

30

40

50

607080

900

253

505

758

1010

1263

1515

2020

2273

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

BARE 4W

PHOTOMETRIC REPORT 4255-UFL-LED 4W 17

V1.1-201805www.eurekalighting.comEureka Lighting©2018

CCT (K):Delivered Lumens (lm):System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40004773.8Direct126C

Rectanglein (mm)10.8 (274.32)10.8 (274.32)10.8 (274.32)

0.290.290.27

4255-UFL-LED 4W 17˚

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

0 - 180

anglescd

0 - 90

0

10

20

30

40

50

607080

900

253

505

758

1010

1263

1515

2020

2273

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

Photometric Report

BARE 4W

PHOTOMETRIC REPORT 4255-UFL-LED 4W 48

V1.1-201805www.eurekalighting.comEureka Lighting©2018

CCT (K):Delivered Lumens (lm):System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40004793.8Direct126C

Rectanglein (mm)10.8 (274.32)10.8 (274.32)10.8 (274.32)

0.920.920.82

4255-UFL-LED 4W 48˚

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

0 - 180

anglescd

0 10

20

30

40

50

60

70

80

90

100

110180

0

63

63

126

189

252

315

378

441

504

566

0 - 90

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

BARE 4W

PHOTOMETRIC REPORT 4255-UFL-LED 4W 48

V1.1-201805www.eurekalighting.comEureka Lighting©2018

CCT (K):Delivered Lumens (lm):System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40004793.8Direct126C

Rectanglein (mm)10.8 (274.32)10.8 (274.32)10.8 (274.32)

0.920.920.82

4255-UFL-LED 4W 48˚

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

0 - 180

anglescd

0 10

20

30

40

50

60

70

80

90

100

110180

0

63

63

126

189

252

315

378

441

504

566

0 - 90

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

BARE 8W

PHOTOMETRIC REPORT 4255-UFL-LED 8W 17

V1.1-201805www.eurekalighting.comEureka Lighting©2018

CCT (K):Delivered Lumens (lm):System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40008748Direct109C

Rectanglein (mm)10.8 (274.32)10.8 (274.32)10.8 (274.32)

0.360.360.34

4255-UFL-LED 8W 17˚

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

0 - 180

anglescd

0 - 90

0

10

20

30

40

50

607080

900

474

949

1423

1898

2372

2847

33211

3796

4270Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

BARE 8W

PHOTOMETRIC REPORT 4255-UFL-LED 8W 17

V1.1-201805www.eurekalighting.comEureka Lighting©2018

CCT (K):Delivered Lumens (lm):System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40008748Direct109C

Rectanglein (mm)10.8 (274.32)10.8 (274.32)10.8 (274.32)

0.360.360.34

4255-UFL-LED 8W 17˚

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

0 - 180

anglescd

0 - 90

0

10

20

30

40

50

607080

900

474

949

1423

1898

2372

2847

33211

3796

4270Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

Photometric Report

BARE 8W

PHOTOMETRIC REPORT 4255-UFL-LED 8W 48

V1.1-201805www.eurekalighting.comEureka Lighting©2018

CCT (K):Delivered Lumens (lm):System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40008768Direct110`C

Rectanglein (mm)10.8 (274.32)10.8 (274.32)10.8 (274.32)

0.920.920.82

4255-UFL-LED 8W 48˚

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

0 - 180

anglescd

0 10

20

30

40

50

60

70

80

90

100

110180

0

119

119

237

356

474

593

712

830

949

1068

0 - 90

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

BARE 8W

PHOTOMETRIC REPORT 4255-UFL-LED 8W 48

V1.1-201805www.eurekalighting.comEureka Lighting©2018

CCT (K):Delivered Lumens (lm):System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40008768Direct110`C

Rectanglein (mm)10.8 (274.32)10.8 (274.32)10.8 (274.32)

0.920.920.82

4255-UFL-LED 8W 48˚

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

0 - 180

anglescd

0 10

20

30

40

50

60

70

80

90

100

110180

0

119

119

237

356

474

593

712

830

949

1068

0 - 90

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

PHOTOMETRIC REPORT BARE

4255-UFL

V1.0-2017-0Xwww.eurekalighting.comEureka Lighting © 2017

225 de Liège Ouest, Suite #200Montréal (QC), Canada H2P 1H4Tel : 514.385.3515 Fax : 514.385.4169www.eurekalighting.com

0.0 10 20

30

40

50

60

70

80

90

100

0

72

72

144

216

287

359

431

503

575

CCT (K):Delivered Lumens (lm): System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40001429

18Direct

79.4C

Rectanglein (mm)

11.811 (300)11.811 (300)11.811 (300)

1.181.180.97

0 - 18090 - 270

4255-UFL-LED18-CFR-WHEBare 18W LED

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

cd angles

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

PHOTOMETRIC REPORT BARE

4255-UFL

V1.0-2017-0Xwww.eurekalighting.comEureka Lighting © 2017

225 de Liège Ouest, Suite #200Montréal (QC), Canada H2P 1H4Tel : 514.385.3515 Fax : 514.385.4169www.eurekalighting.com

0.0 10 20

30

40

50

60

70

80

90

100

0

72

72

144

216

287

359

431

503

575

CCT (K):Delivered Lumens (lm): System wattage (W)*:Distribution:Delivered E�cacy (lm/W):Photometric type

Luminous dimensionsLuminous shape:Units:0-180 Axis:90-270 Axis:Height:

Luminaire spacing criteria 2 luminaires, plane 0:2 luminaires, plane 90:4 luminaires:

*System wattage include driver and LED module consumption

40001429

18Direct

79.4C

Rectanglein (mm)

11.811 (300)11.811 (300)11.811 (300)

1.181.180.97

0 - 18090 - 270

4255-UFL-LED18-CFR-WHEBare 18W LED

This photometric report has been generated using methods recommended by the IESNA. Calculations are based on simulated photometric data and can change without notice. End-user environment and application (including, but not limited to, voltage variation and dirt accumulation) can cause actual photometric performance to differ from the performance calculated using the data provided by the manufacturer. In no event will Eureka Lighting be responsible for any loss resulting from any use of this report.

cd angles

Ø11.63"Ø295mm

10.63"270mm

5.50"140mm

Photometric Report

Bare 4255