banner valu beam series sensors
TRANSCRIPT
-
7/30/2019 Banner VALU BEAM Series Sensors
1/48
VALU-BEAM 915 Series Sensors
With Electromechanical Relay Output
VALU-BEAM 915 Series Features Models available for:
- 12 to 28V ac/dc- 90 to 130V ac- 210 to 250V ac
SPDT electromechanical relay output is rated for up to 5 amps switching capacity
Rear panel sensitivity adjustment; top-mounted alignment indicator
Visible red beam on most models, simplifies alignment
Choose models with integral 2 m (6.5') cable or Mini-style QD (quick-disconnect)connector; 9 m (30') cables are also available
Infrared, 880 nm
915 Series Opposed-Mode Emitter (E) and Receiver (R)
SMA91ESMA95RSMA91EQDSMA95RQD
Emitter:10 to 250V
ac/dcReceiver:
90 to 130V ac
2 m (6.5')2 m (6.5')
3-Pin Mini QD5-Pin Mini QD
Models Range Cable*
Supply
Voltage
Output
Type Excess Gain Beam Pattern
SMA91ESMW95RSMA91EQDSMW95RQD
60 m(200')
2 m (6.5')2 m (6.5')
3-Pin Mini QD5-Pin Mini QD
Emitter:10 to 250V
ac/dcReceiver:12 to 28V
ac/dc
SPDTE/m
Relay1
10
100
1.0 m3.3 ft
10 m33 ft
100 m330 ft
0.1 m0.33 ft
EXCESS
GAIN
DISTANCE
1000
Opposed Mode
SMA91E &SMW95R orSMA95R orSMB95R
75 m250ft
60 m200 ft
45 m150 ft
30 m100 ft
15 m50 ft
0
0
500 mm
1000 mm
1500 mm
500 mm
1000 mm
1500 mm
0
20.0 in
40.0 in
60.0 in
20.0 in
40.0 in
60.0 in
DISTANCE
SMA91E with SMW95Ror SMA95R or SMB95ROpposed Mode
SMA91ESMB95RSMA91EQDSMB95RQD
2 m (6.5')2 m (6.5')
3-Pin Mini QD5-Pin Mini QD
Emitter:10 to 250V
ac/dcReceiver:
210 to 250V ac
Effective Beam: 13 mm
*NOTES:
9 m (30') cables are available by adding suffix W/30 to the model number of any cabled sensor (e.g. SMA91E W/30).
A model with a QD connector requires an accessory mating cable. See page 8 for more information.
Opposed-mode sensors have higher excess gain than other models, and so should be used whenever possible. Visible red tracer beam simplifies sensor alignment.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
2/48
VALU-BEAM 915 Series
Infrared, 880 nm
915 Series Opposed-Mode Emitter (E) and Receiver (R)
SMA91ESRSMA95RSRSMA91ESRQDSMA95RSRQD
Emitter:10 to 250V
ac/dcReceiver:
90 to 130V ac
2 m (6.5')2 m (6.5')
3-Pin Mini QD5-Pin Mini QD
Models Range Cable*SupplyVoltage
OutputType Excess Gain Beam Pattern
SMA91ESRSMW95RSRSMA91ESRQDSMW95RSRQD
3 m(10')
2 m (6.5')2 m (6.5')
3-Pin Mini QD5-Pin Mini QD
Emitter:10 to 250V
ac/dcReceiver:
12 to 28V dc
SPDTE/m
Relay
1
10
100
.10 m.33 ft
1.0 m3.3 ft
10 m33 ft
.01 m.033 ft
EXCESS
GAIN
DISTANCE
1000SMA91ESR &SMW95RSR orSMA95RSR orSMB95RSR
Opposed Mode
3.0 m10ft
2.4 m8 ft
1.8 m6 ft
1.2 m4 ft
.6 m2 ft
0
0
100 mm
200 mm
300 mm
100 mm
200 mm
300 mm
0
4.0 in
8.0 in
12.0 in
4.0 in
8.0 in
12.0 in
DISTANCE
SMA91ESR with SMW95RSRor SMA95RSR / SMB95RSROpposed Mode
SMA91ESRSMB95RSRSMA91ESRQDSMB95RSRQD
2 m (6.5')2 m (6.5')
3-Pin Mini QD5-Pin Mini QD
Emitter:
10 to 250Vac/dc
Receiver:210 to 250V ac
PVisible red, 650 nm
Non-Polarized Polarized
Non-Polarized,Polarized
**Retroreflective range is specified using one model BRT-3 retroreflector (3" diameter). Actual sensing range may be more or less than specified,depending upon the efficiency and reflective area of the retroreflector(s) in use. See your Banner Photoelectric catalog for more information.
915 Series Retroreflective Mode
SMA915LVSMA915LVQD
SMB915LVSMB915LVQD
SMA915LVAGSMA915LVAGQD
90 to 130V ac
SMB915LVAGSMB915LVAGQD
2 m (6.5')5-Pin Mini QD
Models Range** Cable*SupplyVoltage
OutputType Excess Gain Beam Pattern
Non-Polarized
90 to 130V ac
2 m (6.5')5-Pin Mini QD
2 m (6.5')5-Pin Mini QD
Polarized
1
10
100
.10 m.33 ft
1.0 m3.3 ft
10 m33 ft
.01 m.033 ft
EXCESS
GAIN
DISTANCE
1000
SMW915LV,SMA915LV,SMB915LV
Retroreflective Mode
with BRT-3 reflector
10 m33 ft
8 m26 ft
6 m20 ft
4 m13 ft
2 m6.5 ft
0
0
50 mm
100 mm
150 mm
50 mm
100 mm
150 mm
0
2.0 in
4.0 in
6.0 in
2.0 in
4.0 in
6.0 in
DISTANCE
SMW915LV, SMA915LV, SMB915LVRetroreflective Mode
With BRT-3 Reflector
210 to 250V ac
2 m (6.5')5-Pin Mini QD
1
10
100
.10 m.33 ft
1.0 m3.3 ft
10 m33 ft
.01 m.033 ft
EXCESS
GAIN
DISTANCE
1000
SMW915LVAG,SMA915LVAG,SMB915LVAG
Retroreflective Mode
with BRT-3 reflector
5 m16 ft
4 m13 ft
3 m10 ft
2 m6.6 ft
1 m3.3 ft
0
0
25 mm
50 mm
75 mm
25 mm
50 mm
75 mm
0
1.0 in
2.0 in
3.0 in
1.0 in
2.0 in
3.0 in
DISTANCE
SMW915LVAG, SMA915LVAG,SMB915LVAGRetroreflective Mode
With BRT-3 Reflector
210 to 250V ac
SMW915LVSMW915LVQD
SMW915LVAGSMW915LVAGQD
0.3 to 4.5 m(1' to 15')
2 m (6.5')5-Pin Mini QD
0.15 to 9 m(6" to 30')
12 to 28Vac/dc
SPDTE/m
Relay
2 m (6.5')5-Pin Mini QD
12 to 28Vac/dc
SPDTE/m
Relay
Opposed-mode sensors have higher excess gain than other models, and so should be used whenever possible. ESR and RSR models small effective beam size enables them to reliably detect relatively small objects; their wide beam angle allows forgiving alignment within the 10 range.
An excellent alternative when opposed-mode sensing is not possible. A visible red beam reduces the potential for false signals from reflective objects (proxing) and simplifies alignment. AG (anti-glare) models polarize the emitted light and filter out unwanted reflections.
Effective Beam: 3.5 mm
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
3/48
VALU-BEAM 915 Series
Infrared, 880 nm
915 Series Diffuse Mode
SMA915DSMA915DQD
SMA915DSRSMA915DSRQD 90 to 130V ac
90 to 130V ac
2 m (6.5')5-Pin Mini QD
2 m (6.5')5-Pin Mini QD
Models Range Cable*SupplyVoltage
OutputType
Excess Gain Beam Pattern
SMW915DSMW915DQD
760 mm(30")
2 m (6.5')5-Pin Mini QD
12 to 28Vac/dc
SPDTE/m
Relay
1
10
100
10 mm.4 in
100 mm4 in
1000 mm40 in
1 mm.04 in
1000
EXCESS
GAIN
DISTANCE
SMW915D,SMA915D,SMB915D
Diffuse Mode
750 mm30 in
600 mm24 in
450 mm18 in
300 mm12 in
150 mm6 in
0
0
6 mm
12 mm
18 mm
6 mm
12 mm
18 mm
0
0.25 in
0.50 in
0.75 in
0.25 in
0.50 in
0.75 in
DISTANCE
SMW915D, SMA915D, SMB915DDiffuse Mode
SMB915DSMB915DQD
SMW915DSRSMW915DSRQD
2 m (6.5')5-Pin Mini QD 210 to 250V ac
380 mm(15")
2 m (6.5')5-Pin Mini QD
12 to 28Vac/dc
SPDTE/m
Relay
1
10
100
10 mm.4 in
100 mm4 in
1000 mm40 in
1 mm.04 in
1000
EXCESS
GAIN
DISTANCE
SMW915DSRSMA915DSRSMB915DSRDiffuse Mode
375 mm15 in
300 mm12 in
225 mm9 in
150 mm6 in
75 mm3 in
0
0
6 mm
12 mm
18 mm
6 mm
12 mm
18 mm
0
0.25 in
0.50 in
0.75 in
0.25 in
0.50 in
0.75 in
DISTANCE
Diffuse Mode
SMW915DSR, SMA915DSR,SMB915DSR
SMB915DSRSMB915DSRQD
2 m (6.5')5-Pin Mini QD 210 to 250V ac
Performance based on 90% reflectance white test card
Visible red, 650 nm
915 Series Convergent Mode
SMA915CVSMA915CVQD
Performance based on 90% reflectance white test card
90 to 130V ac
62.5 mm2.5 in
50 mm2.0 in
37.5 mm1.5 in
25 mm1.0 in
12.5 mm0.50 in
0
0
0.8 mm
1.6 mm
2.4 mm
0.8 mm
1.6 mm
2.4 mm
0
0.03 in
0.06 in
0.09 in
0.03 in
0.06 in
0.09 in
DISTANCE
SMW915CV, SMA915CV, SMB915CVConvergent Mode
2 m (6.5')5-Pin Mini QD
Models Focus Cable*SupplyVoltage
OutputType
Excess Gain Beam Pattern
SMW915CVSMW915CVQD 38 mm
(1.5")
Spot
SizeatFocus:1.5 mm(0.06")
2 m (6.5')5-Pin Mini QD
12 to 28Vac/dc
SPDT
E/mRelay
1
10
100
10 mm.4 in
100 mm4 in
1000 mm40 in
1 mm.04 in
1000
EXCESS
GAIN
DISTANCE
SMW915CV,SMA915CV,SMB915CV
Convergent Mode
SMB915CVSMB915CVQD
2 m (6.5')5-Pin Mini QD 210 to 250V ac
These sensors detect the reflection of their own light from the object being sensed, and so require no special reflectors. They are ideal for applications where the reflectivity and profile of the object are sufficient to return a large portion of the emitted light back to the sensor. Choose DSR models for best response to objects at close range.
Due to their narrow depth of field, these sensors excel at detecting small objects only a fraction of an inch in front of their backgrounds. The precise 0.06" dia. sensing spot focuses 1.5" in front of the sensor lens. The visible red beam simplifies alignment.
*NOTES:
9 m (30') cables are available by adding suffix W/30 to the model number of any cabled sensor (e.g. SMW915CV W/30).
A model with a QD connector requires an accessory mating cable. See page 8 for more information.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
4/48
VALU-BEAM 915 Series
Infrared, 880 nm
Visible red, 650 nm
915 Series Glass Fiber Optic Sensors
SMA915FSMA915FQD 90 to 130V ac
Diffuse mode performance based on 90% reflectance white test card
2 m (6.5')5-Pin Mini QD
Models Range Cable*SupplyVoltage
OutputType
Excess Gain Beam Pattern
SMW915FSMW915FQD
Rangevaries
bysensingmode
andfiberused.
2 m (6.5')5-Pin Mini QD
12 to 28Vac/dc
SPDTE/m
Relay
1
10
100
10 mm.4 in
100 mm4 in
1000 mm40 in
1 mm.04 in
1000
EXCESS
GAIN
DISTANCE
SMW915FSMA915F,SMB915F
Opposed ModeGlass Fibers
IT13S Fibers
IT23S Fibers
500 mm20 in
400 mm16 in
300 mm12 in
200 mm8 in
100 mm4 in
0
0
25 mm
50 mm
75 mm
25 mm
50 mm
75 mm
0
1 in
2 in
3 in
1 in
2 in
3 in
DISTANCE
SMW915F, SMA915F, SMB915FOpposed Mode
IT13S IT23S
SMB915FSMB915FQD
2 m (6.5')5-Pin Mini QD 210 to 250V ac
915 Series Plastic Fiber Optic Sensors
SMA915FPSMA915FPQD 90 to 130V ac
Diffuse mode performance based on 90% reflectance white test card
2 m (6.5')5-Pin Mini QD
Models Range Cable*SupplyVoltage
OutputType
Excess Gain Beam Pattern
SMW915FPSMW915FPQD
Rangevaries
bysensingmodeandfiberused.
2 m (6.5')5-Pin Mini QD
12 to 28Vac/dc
SPDTE/m
Relay
1
10
100
10 mm.40 in
100 mm4.0 in
1000 mm40 in
1 mm.04 in
1000
EXCESS
GAIN
DISTANCE
SMW915FP,SMA915FP,SWB915FP
Opposed ModePlastic Fibers
PIT46U Fibers
PIT26U Fibers
125 mm
5 in
100 mm
4 in
75 mm
3 in
50 mm
2 in
25 mm
1 in
0
0
15 mm
30 mm
45 mm
15 mm
30 mm
45 mm
0
0.6 in
1.2 in
1.8 in
0.6 in
1.2 in
1.8 in
DISTANCE
SMW915FP, SMA915FP, SMB915FPOpposed Mode
PIT46UPIT26U
SMB915FPSMB915FPQD
2 m (6.5')5-Pin Mini QD 210 to 250V ac
An excellent option where sensing must be accomplished in tight, inaccessible or volatile areas. Withstands vibration and shock; immune to electrical noise. Glass fibers withstand high temperatures, extreme moisture and corrosive materials.Not recommended for applications requiring bending or repeated flexing of fibers.
Compatible with most Banner plastic fiber optic assemblies. Excellent option for sensing in tight,inaccessible or volatile areas. Withstands vibration and shock; immune to electrical noise.Functions well at temperatures between -30 and +70C (-20and +158F), withstands repeated flexing. Most are easy to shorten in the field. Not recommended for severe environments.
1
10
100
1 mm.04 in
10 mm.40 in
100 mm4.0 in
.1 mm.004 in
1000
EXCESS
GAIN
DISTANCE
SMW915FP,SMA915FP,SMB915FPDiffuse Mode
Plastic Fibers
PBT46U Fiber
PBT26U Fiber
37.5 mm1.5 in
30 mm1.2 in
22.5 mm0.9 in
15 mm0.6 in
7.5 mm0.3 in
0
0
1.2 mm
2.5 mm
3.8 mm
1.2 mm
2.5 mm
3.8 mm
0
0.05 in
0.10 in
0.15 in
0.05 in
0.10 in
0.15 in
DISTANCE
SMW915FP, SMA915FP, SMB915FPDiffuse Mode
PBT46UPBT26U
37.5 mm1.5 in
30 mm1.2 in
22.5 mm0.9 in
15 mm0.6 in
7.5 mm0.3 in
0
0
.65 mm
1.3 mm
1.9 mm
.65 mm
1.3 mm
1.9 mm
0
0.025 in
0.050 in
0.075 in
0.025 in
0.050 in
0.075 in
DISTANCE
Diffuse Mode
BT23SBT13S
SMW915F, SMA915F,SMB915F
1
10
100
10 mm.4 in
100 mm4 in
1000 mm40 in
1 mm.04 in
1000
EXCESS
GAIN
DISTANCE
Diffuse ModeGlass Fibers
BT23S Fiber
BT13S Fiber
SMW915F
SMA915F,SMB915F
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
5/48
VALU-BEAM 915 Series
Sensitivity Control(Turn CW to Increase)
Red AlignmentLED Indicator
915 Series Sensors DescriptionVALU-BEAM 915 Series sensors are rugged, self-contained photoelectric sensorsdesigned for especially demanding industrial applications where economy, performance,and durability are important. They feature SPDT (single-pole, double-throw, form C)electromechanical relay output and operate from a variety of supply voltages.
Powerful, modulated LED light sources provide a wide sensing range. The sensors areextremely robust; being totally epoxy-encapsulated, they are highly resistant to shock,vibration, moisture and corrosion.
915 Series sensors may be mounted from either the front or the rear, using the twothrough-mount holes, or by their threaded base (mounting nut supplied), making themideal for conveyor and other production line applications.
The easy-to-see top-mounted red LED indicator (see Figure 1) simplifies alignment andsystem monitoring. It lights whenever the sensor sees its own modulated light source.Turn the Sensitivity control (on the sensor back panel) clockwise to increase gain.
Light or dark operate is selected by connecting the appropriate output relay contact tothe circuit under control (see Hookups, page 7).
Fiber Optic ModelsBanner offers a complete line of both plastic and glass fiber optic assemblies to fitVALU-BEAM 915 Series fiber optic model sensors. Glass fiber assemblies arerecommended for environments with high temperatures, extreme moisture andcorrosive materials; they are not recommended for applications requiring bending orrepeated flexing of fibers.
Plastic fiber optics are an economical alternative for piping photoelectric sensing lightinto and out of confined areas where the environmental conditions allow, and they canwithstand repeated flexing. Banner plastic fiber optic assemblies are available in severalcore sizes; the highest excess gain will be obtained with the larger fiber cores. Standardplastic fiber optic assemblies are unterminated on the control (sensor) end. Theseassemblies are approximately 2 m (6) long and may be used as-is, or may be cut tolength as needed, using the supplied fiber cutter. Cutting and installation instructionsalso are included with the fiber assembly.
Both plastic and glass fibers are offered in individual and bifurcated styles. Individualfibers are used in pairs in the opposed sensing mode; one fiber transmits the light tothe sensing location, while the other fiber returns the received light to the sensor.Bifurcated plastic fiber assemblies are two-way fibers, having a single sensing end thatboth emits and receives light and dual control (sensor) ends, which attach separately tothe sensor. Fiber optic assemblies are available with a wide variety of sensing endstyles. Refer to your current Banner Photoelectric Catalog for a full selection.
*NOTES:
9 m (30') cables are available by adding suffix W/30 to the model number of any cabled sensor (e.g. - SMW915FP W/30).
A model with a QD connector requires an accessory mating cable. See page 8 for more information.
Figure 1. VALU-BEAM 915 Series sensorfeatures
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
6/48
VALU-BEAM 915 Series
Certifications
Supply Voltage and Current SMW915 Series: 12 to 28V ac or dc at 50 mA maximum, exclusive of loadSMA915 Series: 90 to 130V ac (50-60 Hz) at 20 mA maximum, exclusive of loadSMB915 Series: 210 to 250V ac (50-60 Hz) at 20 mA maximum, exclusive of loadExceptions: SMA91E and ESR emitters, which operate from 10-250V ac (50-60 Hz) or dc (10 mA max.)
Supply Protection Circuitry Protected against transient voltages
Output Configuration One internal form C (single-pole double-throw) electromechanical relay
Output Rating Max. switching power (resistive load): 150 W, 600 VAMax. switching voltage (resistive load): 250V ac or 30 V dc (120V ac max. per UL & CSA)Max. switching current (resistive load): 5AMin. voltage and current: 1 amp at 5V dc, 0.1 amp at 24V dcPeak switching voltage: 750V ac (transient suppression recommended)Mechanical life of relay: 10,000,000 operations
Output Protection Circuitry Protected against false pulse on power-up
Output Response Time 20 milliseconds ON and OFF; independent of signal strength(NOTE: 100 millisecond delay on power-up; relay de-energized during this time)
Adjustments Sensitivity control on rear of sensor allows precise gain setting (turn clockwise to increase gain)
Indicators Top-mounted red LED indicator lights whenever the sensor sees light condition.Models SMA91E and SMA91ESR emitters have visible-red tracer beam which indicates power on andenables easy line-of-sight alignment.
Construction Reinforced black thermoplastic polyester housing, totally encapsulated, molded acrylic lenses and stainlesssteel hardware
Environmental Rating Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12 and 13; IEC IP66
Connections Emitters: PVC-jacketed 2 m (6.5') or 9 m (30') cable or 3-pin Mini-style quick-disconnect (QD) fittingavailable. See page 8.All Other Sensors: PVC-jacketed 2 m (6.5') or 9 m (30') cable or 5-pin Mini-style quick-disconnect (QD)fitting available. See page 8.
Operating Conditions Temperature: -40 to +50 C (-40 to +122F)Maximum relative humidity: 90% at 50C (non-condensing)
Application Notes Install transient suppressor (MOV) across any output contact which switches an inductive load
915 Series Specifications
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
7/48
VALU-BEAM 915 Series
bu
yewh NC (Dark Operate)
C
NO (Light Operate)
bn +
bk
Supply Voltage*
*see Specifications
NC (Dark Operate)
C
NO (Light Operate)
bu
yewh
bn
bk
+
Supply Voltage*
*see Specifications
bn
bu
+
10-250V ac/dc
bn
bk
bu 10-250V ac/dc+
Emitters with Attached Cable Emitters with Quick-Disconnect(3-Pin Mini-Style)
3-Pin Mini-Style Pin-out(Cable Connector Shown)
Brown WireBlue Wire
Black Wire
5-Pin Mini-Style Pin-out(Cable Connector Shown)
Black Wire
Blue WireBrown Wire
Yellow Wire
White Wire
915 Series Hookups
36.6 mm(1.44")
35.6 mm(1.40")
LED Indicator
Lens Centerline
50.8 mm(2.00")
12.7 mm(0.50")
M30 x 1.5 External Thread1/2" - 14 NPSM Internal Thread
39.1 mm(1.54")
Hex Nut Supplied
26.7 mm(1.05")
Mini-styleQuick-disconnect
With Attached Cable With Quick-Disconnect
Opposed, Retro, and Diffuse Sensing Modes(model suffix E, ESR, R, RSR, LV, D & DSR)
915 Series Dimensions
39.6 mm(1.56")
Convergent Sensing Mod(model suffix LVAG & C
Glass Fiber Optic Models(model suffix F)
42.2 mm(1.66")
Fiber Port Centerline
Plastic Fiber Optic Models(model suffix FP)
42.2 mm(1.66")
Fiber Port Centerline
25.4 mm(1.00")
4.5 mm(#10) Screw Clearance (2)
17.8 mm(0.70")
5.6 mm(0.22")
Rear View, All Models
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
Sensors with Attached Cable Sensors with Quick-Disconnect(5-Pin Mini-Style)
-
7/30/2019 Banner VALU BEAM Series Sensors
8/48
VALU-BEAM 915 Series
65C (150F)BRT-2A
ModelReflectivity
FactorMaximum
TemperatureBRT-3* 1.0
1.0
84 mm diameter
65C (150F)BRT-50 1.056 mm diameter
65C (150F)65C (150F)BRT-1
BRT-1.5 1.01.0
Size
51 mm diameter
65C (150F)BRT-.6 1.0
46 mm diameter
65C (150F)BRT-50D* 1.0
25 mm diameter
50C (120F)
50C (120F)BRT-92X92C*
BRT-100X55A
50C (120F)
50C (120F)BRT-50R*
BRT-42D 1.0
1.0
20 mm diameter51 mm diameter
50C (120F)BRT-25R 1.0
132 mm x 55 mm50C (120F)BRT-42A 1.0
100 mm x 100 mm
1.5
3.0
42 mm diameter
51 mm diameter
50C (120F)BRT-77X77C* 2.0
25 mm diameter
50C (120F)BRT-100X50 1.5
42 mm diameter
50C (120F)50C (120F)BRT-36X40BM
BRT-2X2 1.01.2**
85 mm x 85 mm101 mm x 51 mm
50C (120F)BRT-60X40C* 1.4
51 mm x 61 mm
50C (120F)BRT-48X32 1.0
51 mm x 61 mm
50C (120F)65C (150F)BRT-23X14CM**
BRT-48X32B 1.01.2
41 mm x 60 mm33 mm x 48 mm
50C (120F)BRT-40X23 1.4
33 mm x 57 mm
50C (120F)BRT-40X23B 1.4
14 mm x 23 mm
50C (120F)50C (120F)BRT-40X18A
BRT-35X20A 1.41.0
24 mm x 40 mm24 mm x 48 mm
50C (120F)BRT-53X19A 1.4
24 mm x 55 mm
50C (120F)BRT-100X18A 1.4
18 mm x 60 mm
65C (150F)BRT-L .08
19 mm x 72 mm
200C (390F)BRT-41AHT 1.0
19 mm x 120 mm
480C (900F)BRT-4HT*** .15
165 mm x 19 mm41 mm diameter100 mm x 100 mm
65C (150F)BRT-34 1.4 84 mm diameter
50C (120F)BRT-35DM** 1.2 35 mm diameter
65C (150F)BRT-80X50 50 mm x 80 mm1.4
50C (120F)BRT-48X32A 1.0 33 mm x 65 mm
65C (150F)BRT-32X20AM** 1.2 24 mm x 32 mm
65C (150F)BRT-62X10AM** 1.2 10 mm x 62 mm
NOTE: The range of all retroreflective sensors is specifiedusing target model BRT-3. Sensing range and signalstrength at any given sensor-to-target distance will varydue to target reflectivity and target area. AReflectivityFactor is included for each target model to help predictsensor performance, relative to the excess gain curveplotted for target model BRT-3. Consider, also, targetarea when predicting performance.
* Optional brackets are available; see Banner Photoelectric Product Catalog** Target has micro-prism geometry*** Targets are not recommended for polarized retroreflective sensors
Retroreflective Targets
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
65C (150F)
-
7/30/2019 Banner VALU BEAM Series Sensors
9/48
VALU-BEAM 915 Series
MINI-BEAM Mounting Brackets
SMB30C 30 mm split clamp bracket Black reinforced thermoplastic polyester Includes stainless steel mounting hardware
SMB30MM 30 mm, 12-ga, stainless steel bracket with curved
mounting slots for versatility and orientation Clearance for M6 (1 / 4") hardware
56.0 mm(2.20")
63.0 mm(2.48")
45.0 mm(1.77")
2.5 mm(0.10")
31.5 mm(1.24")
Nut Plate
M5 x 0.8x 80 mm
Screw (2)
13 mm(0.5")
13.5 mm (0.53")35.1 mm
(1.38")
35.1 mm
(1.38")
69.9 mm
(2.75")
7.1 mm.28 x 90 (2 Slots)
R 25.4 mm(1.00")
30.1 mm(1.19")
57.2 mm(2.25")
25.4 mm(1.00")
25.4 mm(1.00")
6.4 mm(0.25" dia.)
57.2 mm
(2.25")
SMB30SC
30 mm swivel bracket Black reinforced thermoplastic polyester Includes stainless steel mounting and swivel locking
hardware
50.8 mm(2.00")
58.7 mm(2.31")
66.5 mm(2.62")
30.0 mm(1.18")
29.0 mm(1.14")
12.7 mm(0.50")
M30 x 1.5internal
thread
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
10/48
VALU-BEAM 912 Series
AC- and DC-powered sensors with solid-state outputs
WARNING . . . Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. Asensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current BannerSafety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Features
Choose models for 10 to 30V dc or 24 to 250V ac operation.
DC models have bipolar solid-state outputs: one NPN (sinking) and one PNP(sourcing).
AC models have an SPST solid-state output rated for up to 3/4 amp with simple2-wire hookup.
All models have a rear panel sensitivity adjustment and light/dark operate switch.
DC models include Banners Alignment Indicating Device (AID) system.
Choose models with integral 2 m (6.5') cable or Mini-style QD (quick-disconnect)
connector; 9 m (30') cables are also available.
Opposed Mode Emitter (E) and Receiver (R) Models
Models Range Cable* SupplyVoltageOutputType Excess Gain Beam Pattern
SMA91ESMA91EQD
60 m(200')
2 m (6.5')3-Pin Mini QD 10-250V ac/dc
SM91RSM91RQD
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A91RSM2A91RQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCRSolid-state
2-Wire
SMA91ESRSMA91ESRQD
3 m(10')
2 m (6.5')3-Pin Mini QD 10-250V ac/dc
SM91RSRSM91RSRQD
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A91RSRSM2A91RSRQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCR
Solid-state2-Wire
* 9 m cables are available by adding suffix W/30 to the model number of any cabled sensor (e.g., SMA91E W/30).A model with a QD connector requires a mating cable; see page 7.
Infrared, 880 nm
Mg
Mg
Mg
Mg
%8#%33
'!).
$)34!.#%
3-! % 3- 23-! % 3- ! 2
/PPOSED -ODE
Mg
Mg
Mg
Mg
%8#%33
'!).
$)34!.#%
3-! %32 3- 2323-! %32 3- ! 232
/PPOSED -ODE
MgMgMgMgMg
MM
MM
MM
MM
MM
MM
$)34!.#%
3-! %32 3- 2323-! %32 3- ! 232/PPOSED -ODE
Mg
Mg
Mg
Mg
Mg
MM
MM
MM
MM
MM
MM
$)34!.#%
3-! % 3- 23-! % 3- ! 2/PPOSED -ODE
Effective Beam: 3.5 mm
Effective Beam: 13 mm
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
11/48
VALU-BEAM Sensors 912 Series
Retrore lective Mode Models
Retroreflective range is specified using one model BRT-3 retroreflector (3" diameter). Actual sensing range may be more or less than specified,depending upon the efficiency and reflective area of the retroreflector used.
Use polarized models when shiny objects will be sensed.
PVisible Red, 650 nm
Non-Polarized Polarized
Models Range Cable* SupplyVoltage OutputType Excess Gain Beam Pattern
Non-Polarized
SM912LVSM912LVQD 0.15
to 9 m(6" to30')
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A912LVSM2A912LVQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCRSolid-state
2-Wire
Polarized
SM912LVAGSM912LVAGQD 0.3 to
4.5 m(1' to15')
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A912LVAGSM2A912LVAGQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCRSolid-state
2-Wire
Mg
Mg
Mg
Mg
%8#%33
'!).
$)34!.#%
3- ,63- ! ,6
2ETROREFLECTIVE -ODE
7ITH "24 2EFLECTOR
Mg
Mg
Mg
Mg
%8#%33
'!).
$)34!.#%
3- ,6!'
3- ! ,6!'2ETROREFLECTIVE -ODE
7ITH "24 2EFLECTOR
Mg
Mg
Mg
Mg
Mg
MM
MM
MM
MM
MM
MM
$)34!.#%
3- ,6!' 3- ! ,6!'2ETROREFLECTIVE -ODE
7ITH "24 2EFLECTOR
Mg
Mg
Mg
Mg
Mg
MM
MM
MM
MM
MM
MM
$)34!.#%
3- ,6 3- ! ,62ETROREFLECTIVE -ODE
7ITH "24 2EFLECTOR
Di use Mode Models
Models Range Cable* SupplyVoltageOutputType
Excess Gain Beam PatternPerformance based on 90% reflectance white test card
SM912DSM912DQD
760 mm(30")
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A912DSM2A912DQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCRSolid-state
2-Wire
SM912DSRSM912DSRQD
380 mm(15")
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A912DSRSM2A912DSRQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCRSolid-state
2-Wire
Infrared, 880 nm
MM MM MMMM
%8#%33
'!).
$)34!.#%
3- $3- ! $
$IFFUSE -ODE
MM MM MMMM
%8#%33
'!).
$)34!.#%
3- $323- ! $32$IFFUSE -ODE
MMMMMMMMMM
MM
MM
MM
MM
MM
MM
$)34!.#%
3- $32 3- ! $32$IFFUSE -ODE
MMMMMMMMMM
MM
MM
MM
MM
MM
MM
$)34!.#%
3- $ 3- ! $$IFFUSE -ODE
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
12/48
VALU-BEAM Sensors 912 Series
Convergent Mode Models
*9 m (30') cables are available by adding suffix W/30 to the model number of any cabled sensor (e.g., SMA91EF W/30).A model with a QD connector requires a mating cable; see page 7.
Visible Red or Infrared; see below
Glass Fiber Optic Individual Emitter or Receiver Models
Models Range Cable* Supply Voltage Output Type Excess Gain Beam Pattern
SMA91EFSMA91EFQD
Rangevarieswithfiberused
2 m (6.5')3-Pin Mini QD 10-250V ac/dc
SM91RFSM91RFQD
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A91RFSM2A91RFQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCRSolid-state
2-Wire
Infrared, 880 nm
Mg
Mg
Mg
Mg
%8#%33
'!).
$)34!.#%
3-! %& 3- 2&3-! %& 3- ! 2&
/PPOSED -ODE
)4 3 &IBERS7 , ,ENSES
)4 3 &IBERS7 , & ,ENSES
Mg
Mg
Mg
Mg
Mg
MM
MM
MM
MM
MM
MM
$)34!.#%
3-! %& 3- 2&3-! %& 3- ! 2&/PPOSED -ODE
)4 3 &IBERS7ITH , LENSES
)4 3 &IBERS7ITH , & LENSES
Use where the separation between emitting and receiving fibers is more than a few feet,or where it is inconvenient to run both fibers from a single sensor. Watertight o-ring- sealed sensor/fiber interface.
Models Range Cable* SupplyVoltage OutputType Excess Gain Beam PatternPerformance based on 90% reflectance white test card
Visible Red 650 nm
SM912CVSM912CVQD
38 mm(1.5")
SpotSize
at Focus:1.5 mm(0.06")
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A912CVSM2A912CVQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCRSolid-state
2-Wire
Infrared 880 nm
SM912CSM912CQD
38 mm(1.5")
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A912CSM2A912CQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCRSolid-state
2-Wire
MM MM MMMM
%8#%33
'!).
$)34!.#%
3- #63- ! #6
#ONVERGENT -ODE
MM MM MMMM
%
8#%33
'!).
$)34!.#%
3- #3- ! #
#ONVERGENT -ODE
MMMMMMMMMM
MM
MM
MM
MM
MM
MM
$)34!.#%
3- # 3- ! ##ONVERGENT -ODE
MMMMMMMMMM
MM
MM
MM
MM
MM
MM
$)34!.#%
3- #6 3- ! #6#ONVERGENT -ODE
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
13/48
VALU-BEAM Sensors 912 Series
* 9 m (30') cables are available by adding suffix W/30 to the model number of any cabled sensor (e.g., SM912F W/30).A model with a QD connector requires a mating cable; see page 7.
DimensionsCabled Models QD Models
Convergent Sensing Mode(model su fx LVAG, C and CV)
Glass Fiber Optic(model su fx F, EF and RF)
Rear View
Glass Fiber Optic Models
Models Range Cable*SupplyVoltage
OutputType
Excess Gain Beam PatternPerformance based on 90% reflectance white test card
SM912FSM912FQD
Rangevarieswith
sensingmode
and fiber
opticsused.
2 m (6.5')4-Pin Mini QD 10-30V dc
BipolarNPN/PNP
SM2A912FSM2A912FQD
2 m (6.5')3-Pin Mini QD 24-250V ac
SPST SCRSolid-state
2-Wire
Infrared, 880 nm
MM MM MMMM
%8#%33
'!).
$)34!.#%
3- &3- ! &/PPOSED -ODE
)4 3 &IBERS
)4 3 &IBERS
MM MM MMMM
%8#%33
'!).
$)34!.#%
3- &3- ! &
$IFFUSE -ODE
"4 3 &IBER
"4 3 &IBER
MMMMMMMMMM
MM
MM
MM
MM
MM
MM
$)34!.#%
3- & 3- ! &$IFFUSE -ODE
"4 3"4 3
MMMMMMMMMM
MM
MM
MM
MM
MM
MM
$)34!.#%
3- & 3- ! &/PPOSED -ODE
)4 3 )4 3
36.6 mm(1. ")
35.6 mm(1. 0")
LED Indicator
Lens Centerline
50.8 mm(2.00")
12. mm(0.50")
M30 x 1.5 External Thread1/2" - 1 NPSM Internal Thread
39.1 mm(1.5 ")
Hex Nut Supplied
39.6 mm(1.56")
26. mm(1.05")
Mini-styleQuick-disconnect
M30 x 1.5 ThreadHex Nut Supplied
,IGHT $ARK /PERATE 3ELECT, / #7 $ / ##7
3ENSITIVITY #ONTROL4URN #7 TO )NCREASE
MM
MM3CREW #LEARANCE
MM
MM
./4% #ONTROL POTENTIOMETERS ABEHIND COVER SCREWS REMOVESCREWS TO ACCESS CONTROLS
2.2 mm(1.66")
Fiber Port Centerline
Watertight o-ring-sealed sensor/fiber interface.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
14/48
VALU-BEAM Sensors 912 Series
Other DC Models Cabled
DC Hookups
Supply Voltage and Current 10 to 30V dc at 20 mA maximum, exclusive of load (except for SMA91E, ESR and EF emitters, which operate
from 10 to 250V ac or dc, 10 mA max.)Supply Protection Circuitry Protected against reverse polarity and transient voltages
Output Configuration Bipolar: One current sourcing (PNP) and one current sinking (NPN) open-collector transistor
Output Rating 250 mA continuous, each outputOff-state leakage current: less than 10 microampsOutput saturation voltage: (PNP output) less than 1 volt at 10 mA and less than 2 volts at 250 mAOutput saturation voltage: (NPN output) less than 200 millivolts at 10 mA and less than 1 volt at 250 mA
Output Protection Circuitry Protected against false pulse on power-up and continuous overload or short-circuit of outputs
Output Response Time Receivers only: 8 milliseconds ON and 4 milliseconds OFF, independent of signal strength.All other models: 4 milliseconds ON/OFFNOTE: 100 millisecond delay on power-up; outputs do not conduct during this delay.
Repeatability Opposed and Glass Fiber Optic Emitter-Receiver pairs: 1.0 millisecondRetro, Diffuse, Convergent and Glass Fiber Optic Models: 1.3 milliseconds
Adjustments Light/Dark Operate select switch and Sensitivity control potentiometer, both located at rear of sensor
Indicators Alignment Indicating Device (AID) lights a top-mounted red LED indicator whenever the sensor sees alight condition; its pulse rate is proportional to the light signal strength (the stronger the signal, the fasterthe pulse rate).Model SMA91E and SM91ESR emitters: visible-red tracer beam indicates Power ON and enablesline-of-sight alignment.
Construction Reinforced thermoplastic polyester housing, totally encapsulated, molded acrylic lenses and stainless steelhardware
Environmetal Rating Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12 and 13; IEC IP66
Connections PVC-jacketed 2 m (6.5') or 9 m (30') cables or 4-pin Mini-style quick-disconnect (QD) fitting available.NOTE: Opposed-mode emitters use 3-pin Mini-style QD fitting. See page 7.
Operating Conditions Temperature: -20 to +70 C (-4 to +158 F)Maximum relative humidity: 90% at 50 C (non-condensing)
Certifications
Speci ications DC Models
Other DC Models QD( -Pin Mini-Style)
Emitters CabledEmitters QD
(3-Pin Mini-Style)
-Pin Mini-Style Pinout(Cable Connector Shown)
3-Pin Mini-Style Pinout(Cable Connector Shown)
bn
wh
bu+
bkLoad
Load
10-30V dc
bn
wh
bu+
bkLoad
Load
10-30V dc
bn
bu
+
10-250V ac/dc
bn
bk
bu
10-250V ac/dc+
Black Wire
Blue WireBrown Wire
White Wire
Brown WireBlue Wire
Black Wire
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
15/48
VALU-BEAM Sensors 912 Series
Other AC Models Cabled
AC Hookups
Supply Voltage and Current 24 to 250V ac (50/60 Hz), except for SMA91E, ESR and EF emitters, which operate from 10 to 250V ac or dc
Supply Protection Circuitry Protected against transient voltages
Output Configuration SPST SCR solid-state relay with either normally closed or normally open contact(light/dark operate selectable); 2-wire hookup
Output Rating Minimum load current 10 mA, max. steady-state load capability 750 mA to 50 C ambient (122 F),500 mA to 70 C ambient (158 F)Inrush capability: 4 amps for 1 second (non-repetitive)Off-state leakage: current less than 1.7 mA rmsOn-state voltage drop: 5 volts rms at 750 mA load, 10 volts rms at 15 mA load
Output Protection Circuitry Protected against false pulse on power-up
Output Response Time Receivers only: 8 milliseconds 0N and 4 milliseconds OFF, independent of signal strengthAll other models: 8 milliseconds ON and OFFOFF time does not include load response of up to 1/2 ac cycle (8.3 milliseconds).Response time specification of the load should be considered when total response time is important.NOTE: 300 millisecond delay on power-up; outputs do not conduct during this delay.
Repeatability Opposed and Glass Fiber Optic Emitter-Receiver pairs: 1.0 millisecondRetro, Diffuse, Convergent and Glass Fiber Optic: 2.6 milliseconds
Adjustments Light/Dark Operate select switch and Sensitivity control potentiometer, both located at rear of sensor
Indicators Top-mounted red LED indicator lights when output is conducting.Model SMA91E and SM91ESR emitters: visible-red tracer beam indicates Power ON and enables line-of-sight alignment.
Construction Reinforced thermoplastic polyester housing, totally encapsulated, molded acrylic lenses and stainless steelhardware
Environmetal Rating Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12 and 13; IEC IP66
Connections PVC-jacketed 2 m (6.5') or 9 m (30') cables or 3-pin Mini-style (QD) fitting available. See page 7.
Operating Conditions Temperature: -20 to +70 C (-4 to +158 F) Maximum relative humidity: 90% at 50 C (non-condensing)
Application Notes i) 912 Series ac sensors can be destroyed from overload conditions.ii) Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state
voltage of the sensor will interfere with proper operation of the load.iii) The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in
series or parallel with mechanical switch contacts.
Certifications
Speci ications AC Models
Other AC Models QD(3-Pin Mini-Style)
Emitters CabledEmitters QD
(3-Pin Mini-Style)
3-Pin Mini-Style Pinout(Cable Connector Shown)
bn
bu Load24-250V ac
bn
bk
bu 24-250V acLoad
+
bn
bu
+
10-250V ac/dc
Brown WireBlue Wire
Black Wire
bn
bk
bu
10-250V ac/dc+
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
16/48
VALU-BEAM Sensors 912 Series
Retrore lective Targets
Extension Cables (without connectors)
The following cables are available for extending the length of existing sensor cable. These are 30 m (100') lengths of VALU-BEAM cable.This cable may be spliced to existing cable. Connectors, if used, must be customer-supplied.
Model Type Used With:
EC312-100 4-conductor SM912 Series dc sensors
EC312A-100 2-conductor For all emitters and SM2A912 Series ac sensors
Cabling Accessories
Accessories
Quick-Disconnect Cables
Cable: PVC jacket, polyurethane connector body; nylon coupling nutConductors: 18 AWG, high-flex stranded, PVC insulation, gold plated contactsTemperature: -40 to +80 C (-40 to +176 F)
Style Model Length Dimensions Pinout (Female View)
3-PinMini-styleFemale, Straight
MBCC-306MBCC-312MBCC-330
2 m (6.5)4 m (12)9 m (30)
4-PinMini-styleFemale, Straight
MBCC- 06MBCC- 12MBCC- 30
2 m (6.5)4 m (12)9 m (30)
Brown WireBlue Wire
Black Wire
/8-16UN-2B
28 mm max.(1.1")
61 mm max.(2. ")
Black Wire
Blue WireBrown Wire
White Wire
Model Description
AC-6PVC-6RF1-2NPS
2 m (6.5') armored cable jacket2 m (6.5') flexible PVC tubing (not for QD models)Compression fitting for attaching armored cable or PVC tubing
I.D. 5/16"; O.D. 7/16"I.D. 1/4"; O.D. 3/8"
HF1-2NPS
Flexible black nylon cable protector Includes a neoprene gland that compresses around the VALU-BEAM cable to provide
an additional seal against moisture Resistant to gasoline, alcohol, oil, grease, solvents and weak acids Working temperature range of -30 to +100 C (-22 to +212 F)
Banner offers a wide selection of high-quality retroreflective targets. See the Accessoriessection of your current Banner Photoelectric Sensors catalog for complete information.
NOTE: Polarized sensors require corner cube type retroreflective targets. Non-polarizedsensors may use any retroreflective target.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
17/48
VALU-BEAM Sensors 912 Series
P/N 03467 rev. E
WARRANTY:Banner Engineering Corp. warrants itsproducts to be free from defects for one year. BannerEngineering Corp. will repair or replace, free of charge, anyproduct of its manufacture found to be defective at the timeit is returned to the factory during the warranty period. Thiswarranty does not cover damage or liability for the improperapplication of Banner products. This warranty is in lieu ofany other warranty either expressed or implied.
Mounting Brackets
SMB30C 30 mm split clamp, black PBT bracket Stainless steel mounting hardware included SMB30SC 30 mm swivel, black PBT bracket Stainless steel mounting hardware included
SMB30MM
30 mm, 12-gauge stainless steel bracketwith curved mounting slots for versatileorientation
Clearance for M6 (1/4") hardware
50.8 mm(2.00")
58. mm(2.31")
66.5 mm(2.62")
30.0 mm(1.18")
29.0 mm(1.1 ")
12. mm(0.50")
M30 x 1.5internal
thread
56.0 mm(2.20")
63.0 mm(2. 8")
5.0 mm(1. ")
2.5 mm(0.10")
31.5 mm(1.2 ")
Nut Plate
M5 x 0.8x 80 mm
Screw (2)
13 mm(0.5")
13.5 mm (0.53")
35.1 mm
(1.38")
35.1 mm
(1.38")
69.9 mm
(2. 5")
.1 mm.28 x 90 (2 Slots)
R 25. mm(1.00")
30.1 mm(1.19")
5 .2 mm(2.25")
25. mm(1.00")
25. mm(1.00")
6. mm(0.25" dia.)
5 .2 mm
(2.25")
Replacement Lens Assemblies
VALU-BEAM lens assemblies are field-replaceable. In addition, some lenses may be used to convert from one sensing mode to another, orto change the sensing range of a particular sensor. The possible conversions are listed in the table below.
Models Description Possible Sensing Mode or Range Changes
UC-900AGUC-900CUC-900DSRUC-900FUC-900FPUC-900LUC-900J
Replacement lens for LVAGReplacement lens for C and CVReplacement lens for DSR, ESR, and RSRReplacement lens for FReplacement lens for FPReplacement lens for E, R, LV, and DAttach to E, R, ESR, RSR, LV, and D models
Change LV to LVAGChange LV to CVChange D or F to DSR, EF to ESR, and RF to RSRChange D to F and DSR to F
Change LVAG to LV, CV to LV, DSR to D, and F to DFlat polycarbonate dust cover
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
18/48
VALU-BEAM SMI912 SeriesNAMUR Intrinsically Safe DC Sensors
WARNING . . .Not To Be Used for Personnel ProtectionNever use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. Asensor failure or malfunction can cause either an energized or de-energized sensor output condition. Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for personnel protection.
Features Offers economy, performance and reliability in a rugged housing
Provides standard limit-switch mounting hole spacing
Use with approved intrinsically safety barriers and Banner MAXI-AMP moCI3RC2 current trip point amplifier
Certified for use in all Classes, Groups, and Divisions of hazardous locationsdefined by Article 500 of the National Electrical Code when used with approvbarriers
Provides 10 to 30V dc supply voltage with NPN output
Features a light- or dark-operate selection switch
Available in opposed, polarized and non-polarized retroreflective, diffuse, conand glass or plastic fiber optic sensing modes
Ranges up to 60 m
Integral 3-pin Mini-style QD fitting; QD cordset required, see page 9
Models
Models continued on page
SMI912 Series sens or, with CI3RC2 curr entamplifier module (left) and intrinsic safety barrier(right)
Sensing Mode Model Range Voltage
L o n g - R
a n g e
O p p o s e
d 880 nmInfrared SMI91EQD
Emitter60 m (200')
10 to 30V dc
Effective Beam:13 mm (0.5")
SMI91RQDReceiver
S h o r t - R
a n g e
O p p o s e
d 880 nmInfrared SMI91ESRQD
Emitter
3 m (10')
Effective Beam:
3.5 mm (0.14")
SMI91RSRQDReceiver
Sensing Mode Model Range Voltag
N o n - P
o l a r i z e d
R e t r o
650 nmVisible Red
SMI912LVQD150 mm to
9 m(6" to 30')
10 to 30V dc
P o
l a r i z e
d R e t r o
650 nm
Visible Red
SMI912LVAGQD 300 mm to 4.5m (1' to 15')
Performance based on use of a modelBRT-3retroreflector (3" diameter). Actualsensing range may be more or less than specified, depending on the efficienreflective area of the retroreflector used.
RETRO
P
POLAR RETROOPPOSED
OPPOSED
Exia
NRTL/C
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
19/48
VALU-BEAM SMI912 Series NAMUR
Models, continuedSensing Mode Model Range Voltage
L o n g - R
a n g e
D i f f u s e 880 nm
Infrared
SMI912DQD 760 mm (30")
10 to 30V dc
S h o r t - R
a n g e
D i f u s s e
SMI912DSRQD 380 mm (15")
C o n v e r g e n t
650 nmVisible Red
SMI912CVQD
Focus at:38 mm (1.5")
Spot Size atFocus: 1.5 mm(0.06")
Sensing Mode Model Range Voltage
P l a s t i c
F i b e r
O p t
i c650 nm
Visible Red
SMI912FPQD
Seeperformance
curves onpage 5
10 to 30V dc
G l a s s
F i b e r
O p t i c
880 nmInfrared SMI912EFQD
Emitter Seeperformance
curves onpage 6SMI912RFQD
Receiver
880 nmInfrared
SMI912FQD
Seeperformance
curves onpage 6
Overview
VALU-BEAM SMI912 Series sensors are designed for intrinsically safe operation inhazardous atmospheres. They are certified by Factory Mutual Research, CSA, andKEMA as being intrinsically safe when used with approved intrinsic safety barriers.
SMI912 Series sensors may be wired for either two- or three-wire current-sinkingoperation. In the three-wire hookup, which requires two intrinsic-safety barriers, the sinkcurrent is 15 mA. The two-wire hookup, which requires one barrier, sinks 10 mA (OFFstate) and 20 mA (ON state).
SMI912 Series sensors feature rugged, encapsulated construction, along with adjustablesensitivity and switchable light or dark operate. They also include Banner's exclusiveAlignment Indicating Device system, which lights an indicator LED whenever the sensor sees its modulated light source, and pulses at a rate proportional to the received lightsignal strength.
Intrinsic safety barriers and current trip point amplifier modelCI3RC2are also available(see pages 9 and 10).
AIDCurrentSense
AIDCurrentSense
27Ohms
Brown
Black
BlueCommon
Output
+10 to 30V dc
36VOscillator
AmpReceiver
Emitter
Sens.
Demodulator
Regulator
D.0.
L.0.
Figure 1. Functional schematic
DIFFUSE
CONVERGENT
PLASTIC FIBER
GLASS FIBER
GLASS FIBER
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
20/48
VALU-BEAM SMI912 Series N
Installation NotesFM INSTALLATION1. Barriers must be installed in accordance with manufacturer's instructions.
2. Barrier entity parameters must meet the following requirements:Voc or Vt Vmax Ca Ci + CcableIsc or It I max La Li + Lcable
3. Maximum non-hazardous area voltage must not exceed 250V.
4. For guidance on installation, see ANSI/ISA RP12.6, Installation of IntrinsicaInstrument Systems for Hazardous (Classified) Locations.
5. The sensors are suitable for installation without barriers in Class I Div. 2 GrouC, D; Class II Div. 2 Group G; and Class III Div. 2, when installed in (or throuwall of) a suitable enclosure with provision for connection of rigid metal conduthe National Electrical Code, as acceptable to the local inspection authority ha jurisdiction.
CSA INSTALLATION1. Barriers must be installed in accordance with manufacturer's instructions.
2. Barrier entity parameters must meet the following requirements:Voc Vmax Ca Ci + CcableIsc I max La Li + Lcable
3. Maximum non-hazardous area voltage must not exceed 250V.
4. Install in accordance with Canadian Electrical Code, Part I.
5. The sensors are suitable for installation without barriers in Class I Div. 2 GrouC, D when installed in (or through the wall of) a suitable enclosure with provisconnection of rigid metal conduit per the Canadian Electrical Code, as accepta
the local inspection authority having jurisdiction.In Div. 2 installations (without barriers), observe warning at left.
6. If barriers with Volt/Ohm parameters are used, the following parameters shall
One Single-Channel Barrier Systems one 28V (max), 300 (min)
Two Single-Channel Barrier or One Dual-Channel Systems two 28 V (max), 600 (min) one 28 V (max), 300 (min) and one 10 V (max), 50 (min) one 28 V (max), 300 (min) and one 28 V diode return
Sensor Entity ParametersVmax (Ui) 30V dcImax (li) 100 mAPi 750 mWCi = 0 FLi = 0 mH
WARNING . . .Explosion HazardDo not disconnect
equipment unless power has beenswitched off or the area is known to benon-hazardous.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
21/48
VALU-BEAM SMI912 Series NAMUR
Specifications
ApprovalsKEMA: EN50014, EN50020, EN50284
KEMA No. 03ATEX1441XII 2 G EEx ib IIC T5Ta 20 C .. +70 C
CSA: C22.2 #142-M1987, 157-92, 213-M1987, ExiaCL I DIV 1 GP A-DCL I DIV 2 GP A-D
FM: 3600, 3610, 3810I.S. CL I, II, III DIV 1 GP A-E, GN.I. CL I, II, III DIV 2 GP A-D, G
Supply Voltage and Current Sensor only:requires 10 to 30V dc, 25 mA maximumDivision 1 use (with barriers):requires a minimum system supply voltage of 10 volts(see hookup information and hookup diagrams).
Output Configuration Current sinking NPN open-collector transistor
Output Rating Three-wire hookup sinks 15 mA maximum, continuous (10 to 30V dc)Two-wire hookup sinks 10 mA (OFF state) and 20 mA (ON state), 10 to 30V dc.Outputs are short-circuit protected.
Output Response Time Opposed-mode receivers:8 milliseconds ON/4 milliseconds OFF; independent of signal strengthAll other models:4 milliseconds ON and OFF100 millisecond delay on power-up (output does not conduct during this time).
Sensing Beam Infrared (880 nm) or visible red (650 nm), depending on model
Repeatability Opposed mode:1.0 millisecond All other modes:1.3 millisecondsRepeatability is independent of signal strength.
Adjustments Light/Dark Operate select switch on rear of sensor Sensitivity control on rear of sensor allows precise gain setting (turn clockwise to increase gain)
Indicators Sensors include Banner's exclusive Alignment Indicating Device (AID) system, which lights a top-mounted redindicator LED whenever the sensor sees its modulated light source, and pulses the LED at a rate proportional to received light signal strength.
Construction Housing:reinforced PBT, totally encapsulatedLenses:molded acrylicHardware:stainless steel
Environmental Ratings Meets NEMA standards 1, 2, 3, 3S, 4, 4X, 12, and 13, IEC IP66
Connections Supplied with integral 3-pin Mini-style QD fitting; requires cordset modelMBCC(see Accessories),purchased separately.
Operating Conditions Temperature: 20 to +70 C (4 to +158 F)Max. Relative Humidity :90% @ 50 C (non-condensing)
Certifications
Application Note Special Conditions for Safe Use:Parts of the enclosure are non-conducting and may generate an ignition-capablelevel of ESD. Cleaning of the equipment shall be done only with a damp cloth.
KEMA
Exia
NRTL/C
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
22/48
VALU-BEAM SMI912 Series N
Performance CurvesExcess Gain Beam Pattern
L o n g - R
a n g e
O p p o s e d
S h o r t - R
a n g e
O p p o s e
d
N o n - P
o l a r i z e
d R e t r o
P o
l a r i z e
d R e t r o
Excess Gain Beam PatternDiffuse mode performance based on use of 90% reflectance white test c
L o n g - R
a n g e
D i f f u s e
S h o r t - R
a n g e
D i f f u s e
C o n v e r g e n t
P l a s t
i c F i b e r
O p t i c
0
0
DISTANCE
100 mm
200 mm
300 mm
0.6 m2'
1.2 m4'
1.8 m6'
2.4 m8'
3.0 m10'
SMI91ESRQD/SMI91RSRQD
100 mm
200 mm
300 mm
0
4 "
8 "
12 "
4 "
8 "
12 "
0
0
DISTANCE
500 mm
1000 mm
1500 mm
15 m50'
30 m100'
45 m150'
60 m200'
75 m250'
SMI91EQD/SMI91RQD
500 mm
1000 mm
1500 mm
0
20 "
40 "
60 "
20 "
40 "
60 "
1
10
100
.1 m.33 '
1 m3.3 '
10 m33 '
EXCESS
GAIN
DISTANCE
.01 m.033 '
1000
SMI91ESRQD &SMI91RSRQD
1
10
100
1 m3.3 '
10 m33 '
100 m330 '
EXCESS
GAI
N
DISTANCE
.1 m.33 '
1000
SMI91EQD &SMI91RQD
75 mm3.0"
60 mm2.4"
45 mm1.8"
30 mm1.2"
15 mm0.60"
0
0
0.8 mm
1.6 mm
2.4 mm
0.8 mm
1.6 mm
2.4 mm
0
0.03"
0.06"
0.09"
0.03"
0.06"
0.09"
DISTANCE
Convergent Mode
SMI912CVQD
0
0
DISTANCE
6.5 mm
13 mm
19.5 mm
75 mm3"
150 mm6"
225 mm9"
300 mm12"
375 mm15"
SMI912DSRQD6.5 mm
13 mm
19.5 mm
0
.25"
.50"
.75"
.25"
.50"
.75"
0
0
DISTANCE
6.5 mm
13 mm
19.5 mm
160 mm6"
310 mm12"
460 mm18"
610 mm24"
760 mm30"
SMI912DQD
6.5 mm
13 mm
19.5 mm
0
.25"
.50"
.75"
.25"
.50"
.75"
0
0
DISTANCE
25 mm
50 mm
75 mm
1 m3'
2 m6'
3 m9'
4 m12'
5 m15'
SMI912LVAGQD
25 mm
50 mm
75 mm
with BRT-3 REFLECTOR
0
1"
2"
3"
1"
2"
3"
0
0
DISTANCE
50 mm
100 mm
150 mm
2 m
9'
4 m
15'
6 m
21'
8 m
27'
10 m
33'
SMI912LVQD
50 mm
100 mm
150 mm
with BRT-3 REFLECTOR
0
2"
4"
6"
2"
4"
6"
1
10
100
10 mm.4"
100 mm4"
1000 mm40"
1 mm.04"
1000
EXCESS
GAIN
DISTANCE
SMI912CVQD
Convergent Mode
1
10
100
10 mm.4"
100 mm4"
1000 mm40"
EXCE
SS
GAIN
DISTANCE
1 mm.04"
1000
SMI912DSRQD
Range is based on90% reflectancewhite test card
1
10
100
10 mm.4"
100 mm4"
1000 mm40"
EXCESS
GAIN
DISTANCE
1 mm.04"
1000
SMI912DQD
Range is based on90% reflectancewhite test card
1
10
100
.1 m.33 '
1 m3.3 '
10 m33'
EXCESS
GAIN
DISTANCE
.01 m.033 '
1000SMI912LVAGQD
with BRT-33" retroreflector
1
10
100
.1 m.33'
1 m3.3'
10 m33'
EXCESS
GAIN
DISTANCE
.01 m.033'
1000SMI912LVQD
with 3"reflector (BR T-3)
withBR T-T tape
with 1"reflector (BR T-1)
0
0
DISTANCE
1.25 mm
2.50 mm
3.75 mm
7.5 mm0.3"
15.0 mm0.6"
22.5 mm0.9"
30.0 mm1.2"
37.5 mm1.5"
SMI912FPQD - Diffuse Mode
1.25 mm
2.50 mm
3.75 mm
PBT26U PBT46U 0
.05"
.10"
.15"
.05"
.10"
.15"
0
0
DISTANCE
15 mm
30 mm
45 mm
25 mm1"
50 mm2"
75 mm3"
100 mm4"
125 mm5"
SMI912FPQDOpposed Mode
15 mm
30 mm
45 mm
PIT26U
PIT46U
0
0.6"
1.2"
1.8"
0.6"
1.2"
1.8"
1
10
100
1 mm.04"
10 mm.4"
100 mm4"
EXCESS
GAIN
DISTANCE
.1 mm.004"
1000
SMI912FPQDDiffuse modeplastic fiber
withPBT46Ufiber
withPBT26Ufiber
Range is based on90% reflectancewhite test card.
1
10
100
10 mm.4"
100 mm4"
1000 mm40"
EXCESS
GAIN
DISTANCE
1 mm.04"
1000SMI912FPQD
Opposed modeplastic fibers
withPIT46ULenses
withPIT46UNo Lenses
withPIT26UNo Lenses
Performance based on use of a modelBRT-3retroreflector (3" diameter). Actualsensing range may be more or less than specified, depending on the efficiency and
reflective area of the retroreflector used.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
23/48
VALU-BEAM SMI912 Series NAMUR
Excess Gain Beam PatternDiffuse mode performance based on use of 90% reflectance white test card
G l a s s
F i b e r
O p t i c
, O p p o s e
d o r
D i f f u s e
M o
d e
0
0
DISTANCE
0.6 mm
1.2 mm
1.8 mm
7.5 mm.3"
15.0 mm.6"
22.5 mm.9"
30.0 mm1.2"
37.5 mm1.5"
SMI912FQD Diffuse Mode
0.6 mm
1.2 mm
1.8mm
BT13S BT23S
2.4 mm
2.4 mm
0
.025"
.050"
.075"
.025"
.050"
.075"
.1"
.1"
0
0
DISTANCE
50 mm
100 mm
150 mm
1.25 m4'
2.50 m'8'
3.75 m12'
5.00 m16'
6.25 m20'
SMI912FQD
50 mm
100 mm
150 mm
w/L9 lens w/L16F lens
BT13S fiber, retroreflectivemode, with BRT-3 reflector
0
2"
4"
6"
2"
4"
6"
0
0
DISTANCE
25 mm
50 mm
75 mm
100 mm4"
200 mm8"
300 mm12"
400 mm16"
500 mm20"
SMI912FQD
25 mm
50 mm
75 mm
IT23S fibers
IT23S fibers
0
1"
2"
3"
1"
2"
3"
1
10
100
1 mm.04"
10 mm.4"
100 mm4"
EXCESS
GAIN
DISTANCE
0.1 mm.004 "
1000
with BT23Sfibers
with BT13Sfibers
Diffuse modeRange is based on90% reflectancewhite test card
SMI912FQD
1
10
100
.1 m.33'
1 m3.3'
10 m33'
EXC
ESS
GAIN
DISTANCE
.01m.033'
1000SMI912FQD
Retroreflective modelwith BRT-3 3" target
with L16F lensand BT13Sfibers
with L9 lensand BT13Sfibers
1
10
100
10 mm.4"
100 mm4"
1000 mm40"
EXCESS
GAIN
DISTANCE
1 mm.04"
1000SMI912FQD
Opposed modeglass fibers
IT23S fibers
IT13S fibers
Dimensions
26.7 mm(1.05")
Mini-styleQuick-disconnect
M30 x 1.5 ThreadHex Nut Supplied
36.6 mm(1.44")
35.6 mm(1.40")
LED Indicator
Lens Centerline
50.8 mm(2.00") 39.1 mm
(1.54")
Light/Dark Operate Select(L.O. = CW, D.O. = CCW)
Sensitivity Control(Turn CW to Increase)
25.4 mm(1.00")
4.5 mm(#10) Screw Clearance (2)
17.8 mm(0.70")
5.6 mm(0.22")
NOTE: Control potentiometers arebehind cover screws; removescrews to access controls
0
0
DISTANCE
100 mm
200 mm
300 mm
2.5 m8'
5.0 m16'
7.5 m24'
10.0 m32'
12.5 m40'
SMI91EFQD/SMI91RFQD
100 mm
200 mm
300 mm
IT23S fiberswith L9Lenses
IT23S fiberswith L16FLenses 0
4"
8"
12 "
4"
8"
12 "
0
0
DISTANCE
25 mm
50 mm
75 mm
100 mm4 "
200 mm8"
300 mm12 "
400 mm16 "
500 mm20 "
SMI91EFQD/SMI91RFQD
25 mm
50 mm
75 mm
IT23S
IT13S
0
1 "
2 "
3 "
1 "
2 "
3 "
1
10
100
1 m3.3'
10 m33'
100 m330'
EXCESS
GAIN
DISTANCE
.1 m.33'
1000
SMI91EFQDSMI91RFQD
IT23S andL16F Lenses
IT23S andL9 Lenses
1
10
100
10 mm.4"
100 mm4"
1000 mm40"
EXCESS
GAIN
DISTANCE
1 mm.04"
1000
SMI91EFQDSMI91RFQDOpposed modeglass fibers
IT23S fibers
IT13S fibers
Excess Gain Beam Pattern
G
l a s s
F i b e r
O p t i c
, O p p o s e
d M o
d e
Performance Curves
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
24/48
VALU-BEAM SMI912 Series N
HookupsSMI912 Series sensors are certified intrinsically safe ONLY when used with certienergy-limiting intrinsically safe barriers. Banner does not manufacture such barr
however, our applications engineers can refer you to suppliers of certified barrierswill interface with Banner sensors. SMI912 Series sensors may be wired using BCurrent Amplifier Control Module CI3RC2 (see page 9). Note from the hookup d(page 8) that the installation may be made with either a single barrier (2-wire hooor with a double barrier (3-wire hookup). Emitter-only units (SMI91EQD, ESRQDEFQD) use the 2-wire hookup; all other models use either 2- or 3-wire hookup.
In the 2-wire configuration, the sensor will act as a current sink, drawing less thanin the OFF state and more than 20 mA in the ON state. The user must provide a csensing device (current sensor in the diagram) to convert the current to a logic lthe 3-wire configuration, the output may be used directly to control loads of less t15 mA.
In selecting the barrier, it is important to consider the barrier's resistance. The sen
must have at least 10 volts across the brown and blue power leads for proper operand the barrier will cause a voltage drop due to its resistance. The formula thatdetermines how much resistance is allowed is:
R = 0 (supply voltage 10 volts)
If the supply voltage is 24V dc, then the maximum resistance is 560 ohms. If thesupply voltage is 18V dc, then the maximum resistance is 320 ohms. This includeresistance of any current sensing device used (in the 2-wire configuration), so theresistance must be further reduced by the current sensor resistance.
Note that, in the 3-wire hookup, the positive load barrier is in series with the loadresult in an apparent saturation voltage of the output that is higher than the sensorby the amount of I x R(current times resistance) drop through the barrier.
A positive input barrier is required for both supply and for load. The sensors b(negative supply) lead is normally connected to the ground terminal of the barrier
The user is responsible for proper installation and maintenance of this equipment,must conform with the certification requirements relating to barriers and to maximallowable capacitance and inductance of the field wiring. If in doubt about theserequirements, our applications engineers can refer you to the appropriate authority
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
25/48
VALU-BEAM SMI912 Series NAMUR
Hazardous Area
LOAD
IN
GBlue
15 mAmax.
Bottom View(colors shown are for matingcordset MBCC-312)
Hazardous Area
IN
G
Earth Ground(less than 1 ohm)
Blue
Operating Voltage18-30V dc25 mA dc
Input
Sensor
10 mA (OFF State)20 mA (ON State)
Bottom View(colors shown are for matingcordset MBCC-312)
Connection to Control RoomEquipment should not use or
generate more than 250V
SMI900Series Sensor
V
V
Barriers not required for Div. 230V dc max. (Reference NOTE #5 for FM & CSA on page 3)
Barrier
NOTE: Emitters have no output connection (no connection to black wire)
Safe Area
Safe Area
SMI900Series Sensor
Operating Voltage18-30V dc25 mA dc
3-Wire Hookup
2-Wire Hookup
Busbar Earth Ground(less than 1 ohm)
Barriers not required for Div. 230V dc (reference NOTE #5 for FM & CSA on page 3)
234
423
Hookups, continued
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
26/48
VALU-BEAM SMI912 Series N
Accessories
Current Trip-Point Module
Supply Voltage 105 to 130V ac or 210 to 250V ac, 50/60 Hz (8 VA)
Output Configuration SPDT electromechanical relay:Contact rating:250V ac maximum, 24V dc maximum, 5 amps maximum (resistive load), 1/10 HP at 240V a
Install transient suppressor (MOV) across contacts which switch inductive loads.Min. load: 12V dc, 0.1A.
Closure time:10 milliseconds maximum.Release time:10 milliseconds maximum.Maximum switching speed:20 operations/second.Mechanical l ife:20,000,000 operations
Solid-state dc relay:SPST optically-coupled transistor; 30V dc maximum, 20 mA maximum.
Emitter Power +24V dc at 25 mA maximum available at module pin #3
Inputs Trip point for output " OFF": 10 mA Trip point for output " ON": 20 mA Trip point range for input overload indication:30 mA I 80 mA
Indicators Status Indicators for OUTPUT ON and INPUT overload/short
Construction Housing:rugged polyphenylene oxide (PPO) 1.6" x 2.3" x 4" Standard round-pin 11-pole base. Use RS-11 socket or equivalent.
Operating Conditions Temperature:0 to +50 C (+32 to +122 F)
Model DescriptionCI3RC2 Self-contained module converts the SMI912 sensors current output signal to a trip point switch.
SPDT electromechanical relay switches loads that draw up to 5 amps. The SPST solid-state relay can switch a DC load of 30V dc, max.; 20 mA max.
Powered by either 105-130V ac or 210-250V ac.
Supplies dc power to operate a single sensor or both the emitter and receiver of one SMI Series opposed-mode sensor pair.sensor's input to the CI3RC2 is protected against short circuits. Built-in circuit diagnostics indicate an input overload by flaLED status light.
Module has two isolated output switches, a 5-amp rated SPDT electromechanical relay and a solid-state transistor switch ulogic-level interfaces.
May be ordered either alone or as a part of a kit (see page 10).
Current Trip-Point Module Specifications
Quick-Disconnect (QD) Cordsets
All SMI912 Series sensors require a 3-conductor quick-disconnect cordset. Cordset is not included with the sensor and musseparately.
Style Model Length Dimensions Pinout
3-pinMini-styleStraight
MBCC-30MBCC-312MBCC-330
2 m (6.5')4 m (12')9 m (30')
13
4
1 = Brown3 = Blue = Black
7/8-16UN-2B
28 mmmax.
61 mmmax.
i i i
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
27/48
VALU-BEAM SMI912 Series NAMUR
Receiver models:SMI91RQD,SMI91RSRQD,SMI91RFQD
Emitter models:SMI91EQD,SMI91ESRQD,SMI91EFQD
EMITTER
RECEIVER
4
1 3
Common
InputRelay Output5 amp contacts
105 to 130V ac
210 to 250V ac
ACSupply
CI3RC2OPTO-Coupler Output: 20 mA max.
Hazardous Area
Safe Area
Earth Ground(less than 1)
Blue
Brown
Black
Busbar
10 mA (OFF State)20 mA (ON State)
Brown
Blue
Bottom view of cordsetconnector on sensor (colors shown are for matingcordset model SMICC-312)
Input:
4
1 3
G
Aux.
OUT
SMI SeriesReceiver
SMI SeriesEmitter
IN
IN OUT+
I.S.
+
-
+
+
Dual Barrier
-
Common
InputRelay Output5 amp contacts
105 to 130V ac
210 to 250V ac
ACSupply
CI3RC2OPTO-Coupler
put: 20 mA max.
10 mA (OFF State)20 mA (ON State)
Input:
Aux.
Hazardous Area
Safe Area
Groundhan 1)
Blue
Brown
Black
Busbar
4
1 3
G
OUT
Bottom view of cordsetconnector on sensor (colors shown are for matingcordset model MBCC-312)
IN
I.S.
+
- -
+
V
Barrier I.S.
Current Trip-Point Module Hookups
Hookup for Opposed-Mode Emitters and Receivers
Hookup for Other SMI912 Series Sensors
Accessories, continued
Model(Barrier Only)
BarrierDescription
KitModel
KitDescription
CIB-1 Single-channel intrinsically safe barrier CI2BK-1Includes CI3RC2 current amplifier,one RS-11 socket, one DIN-rail mount,one single-channel intrinsically safe barrier
CI2B-1 Dual-channel intrinsically safe barrier (typicallyused in opposed-mode applications) CI2BK-2Includes CI3RC2 current amplifier,one RS-11 socket, one DIN-rail mount,one dual-channel intrinsically safe barrier
Intrinsic Safety Barriers
:
:
. .
i. .
SMI912SERIESSENSOR
BANNER
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
28/48
VALU-BEAM SMI912 Series N
Mounting Brackets
Bracket dimensions are available online at Banner Engineering website.
SMB30MM
30 mm 12-gauge, 304 stainlesssteel, right-angle mountingbracket with a curved mountingslot for versatile orientation
Clearance for M6 (1/4")hardware
SMB30SC
30 mm swivel bracket
Black reinforced thermoplasticpolyester
Includes stainless steelmounting and swivel lockinghardware
SMB30A
30 mm right-angle mountingbracket with a curved mountingslot for versatile orientation
12-gauge stainless steel
Clearance for M6 (1/4")hardware
Accessories, continued
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
29/48
P r o d u c t L i n e
S p e c i f i c a t i o n s
VALU-BEAM
SensorsRugged, self-contained photoelectric sensors for industrial applications
Printed in USA P/N 32894
Economy, performance, and durability in a family of rugged,self-contained sensors for demanding industrial applications
912 Series sensors have solid-state outputs; models for either10-30V dc or 24-250V ac operation (pages 4 to 9)
915 Series sensors have electromechanical relay output; modelsfor 12-28V ac/dc, 90-130V ac, or 210-250V ac (pages 10 to 13)
990 Series sensors output to a built-in 6-digit totalizing counter;operate from both 12-115V dc and 10-250V ac (pages 14 to 17)
Many models available in opposed, retroreflective, diffuse,convergent beam, and fiber optic sensing modes
Highly-visible top-mounted LED output indicator; 912 Seriessensors have Banner's exclusive, patented AID indicator system
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
30/48
WARRANTY: Banner Engineering Corporation warrants its products to be free from defects for one year. Banner Engineering Corporation will repair or replace,free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty period. This warranty does notcover damage or liability for the improper application of Banner products. This warranty is in lieu of any other warranty either expressed or implied.
2
VALU-BEAMs are a family of rugged, self-contained photoelec-tric sensors designed for especially demanding industrial applica-tions where economy, performance, and durability are important.VALU-BEAMs are built in a variety of operating voltages (both dc
and ac) and output types (solid state and electromechanical relay).SM912 and SM2A912 Series VALU-BEAMs have solid stateoutputs and are available in either 10-30V dc-powered or 24-250Vac-powered models (see specifications, page 4). SMW915,SMA915, and SMB915 Series VALU-BEAMs have electrome-chanical relay output and operate from 12-28V ac/dc, 90-130V ac,or 210 to 250V ac respectively. SMA990 Series VALU-BEAMshave a built-in 6-digit totalizing counter and operate on 12 to 115Vdc or 10 to 250V ac. A fourth VALU-BEAM line, SMI912 Seriesintrinsically safe sensors (low voltage dc sensors having FactoryMutual approval for use with intrinsic-safe barriers in hazardousareas) is covered in data sheet P/N 03396 and the Banner catalog.
Powerful, modulated LED light sources give VALU-BEAM sen-sors greater sensing range than competitive units and a high degreeof immunity to ambient light. All models are totally epoxy-encapsulated and housed in molded VALOX housings for theultimate in shock, vibration, moisture, and corrosion resistance.All VALU-BEAM sensors conform to NEMA standards 1, 2, 3,3S, 4, 4X, 12, and 13.
VALU-BEAM sensors may be mounted from either the front or therear using their two through-mounting holes, or by the outside
threads of their M30x1.5 threaded base (mounting nut supplied),making them ideal for conveyor and other production line applica-tions. A versatile 2-axis steel accessory mounting bracket (modelSMB900) simplifies mounting and alignment. Model SMB30SM
swivel-mount bracket offers the ultimate in flexibility and conve-nience. The bases of standard VALU-BEAMs have a 1/2" NPSintegral internal conduit thread, and are supplied with a 6-footPVC-covered cable. Models with a NEMA-4 rated quick-discon-nect connector (QD models) are available optionally.
All VALU-BEAM sensors have an easily-visible top-mounted redLED indicator to assist in alignment and system monitoring. OnSMA915, SMB915, SMW915, and SMA990 Series VALU-BEAMs, this indicator lights whenever the sensor "sees" itsmodulated light source. On SM2A912 Series 2-wire sensors, theLED lights whenever the load is energized. SM912 Series sensorshave Banner's exclusive, patented "AID" system (Alignment Indi-cating Device, US patent #4356393) which lights the indicatorLED whenever the sensor "sees" its modulated light source, andalso pulses the LED at a rate proportional to the received light signalstrength. This feature greatly simplifies alignment: in most situa-tions, alignment becomes simply a matter of positioning the sensorfor maximum LED pulse rate.
VALU-BEAMs offer a choice of light or dark operate in the samesensor. This is done via a rear panel control or, in the relay outputunits, by offering both N/O and N/C output relay contacts.
!WARNING VALU-BEAM photoelectric presence sensors do NOT include the self-checking redundant circuitry necessaryto allow their use in personnel safety applications. A sensor failure or malfunction can result in either an energized or a de-energizedsensor output condition.
Never use these products as sensing devices for personnel protection. Their use as safety devices may create an unsafe condition whichcould lead to serious injury or death.
Only MACHINE-GUARD and PERIMETER-GUARD Systems, and other systems so designated, are designed to meet OSHA andANSI machine safety standards for point-of-operation guarding devices. No other Banner sensors or controls are designed to meet these standards, andthey must NOT be used as sensing devices for personnel protection.
VALU-BEAM Sensors
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
31/48
Series Model Sensing Mode Range Operating Voltage* Page
912 Series SMA91E & SM91R Opposed: long range 200 feet 10 to 30V dc* p. 5SMA91E & SM2A91R Opposed: long range 200 feet 24 to 250V ac* p. 5SMA91ESR & SM91RSR Opposed: short range 10 feet 10 to 30V dc* p. 5SMA91ESR & SM2A91RSR Opposed: short range 10 feet 24 to 250V ac* p. 5
SM912LV Retroreflective: visible beam 30 feet 10 to 30V dc p. 5SM2A912LV Retroreflective: visible beam 30 feet 24 to 250V ac p. 5SM912LVAG Retroreflective: polarized beam 15 feet 10 to 30V dc p. 5SM2A912LVAG Retroreflective: polarized beam 15 feet 24 to 250V ac p. 5
SM912D Diffuse (proximity): long range 30 inches 10 to 30V dc p. 6SM2A912D Diffuse (proximity): long range 30 inches 24 to 250V ac p. 6SM912DSR Diffuse (proximity): short range 15 inches 10 to 30V dc p. 6SM2A912DSR Diffuse (proximity): short range 15 inches 24 to 250V ac p. 6
VALU-BEAM Sensors
All 990 Seriessensors operatefrom 10 to 250V acor 12 to 115V dc
Sensors withSPDTelectromechanicaloutput relay
Sensors withbuilt-in 6-digittotalizing counter
SM912CV Convergent beam: visible red 1.5-inch focus 10 to 30V dc p. 6SM2A912CV Convergent beam: visible red 1.5-inch focus 24 to 250V ac p. 6SM912C Convergent beam: infrared 1.5-inch focus 10 to 30V dc p. 7SM2A912C Convergent beam: infrared 1.5-inch focus 24 to 250V ac p. 7
SMA91EF & SM91RF Opposed fiber optic: glass fibers see specs 10 to 30V dc* p. 6SMA91EF & SM2A91RF Opposed fiber optic: glass fibers see specs 24 to 250V ac* p. 6
SM912F Fiber optic: glass fibers see specs 10 to 30V dc p. 7SM2A912F Fiber optic: glass fibers see specs 24 to 250V ac p. 7
915 Series SMA91E & SMW95R Opposed: long range 200 feet 12 to 28V ac/dc* p. 11SMA91E & SMA95R Opposed; long range 200 feet 90 to 130V ac* p. 11SMA91E & SMB95R Opposed: long range 200 feet 210 to 250V ac* p. 11SMA91ESR & SMW95RSR Opposed: short range 10 feet 12 to 28V ac/dc* p. 11SMA91ESR & SMA95RSR Opposed: short range 10 feet 90 to 130V ac* p. 11SMA91ESR & SMB95RSR Opposed: short range 10 feet 210 to 250V ac* p. 11
SMW915LV Retroreflective: visible beam 30 feet 12 to 28V ac/dc p. 11SMA915LV Retroreflective: visible beam 30 feet 90 to 130V ac p. 11SMB915LV Retroreflective: visible beam 30 feet 210 to 250V ac p. 11SMW915LVAG Retroreflective: polarized beam 15 feet 12 to 28V ac/dc p. 11SMA915LVAG Retroreflective: polarized beam 15 feet 90 to 130V ac p. 11SMB915LVAG Retroreflective: polarized beam 15 feet 210 to 250V ac p. 11
SMW915D Diffuse (proximity): long range 30 inches 12 to 28V ac/dc p. 12SMA915D Diffuse (proximity): long range 30 inches 90 to 130V ac p. 12SMB915D Diffuse (proximity): long range 30 inches 210 to 250V ac p. 12SMW915DSR Diffuse (proximity): short range 15 inches 12 to 28V ac/dc p. 12SMA915DSR Diffuse (proximity): short range 15 inches 90 to 130V ac p. 12SMB915DSR Diffuse (proximity): short range 15 inches 210 to 250V ac p. 12
SMW915CV Convergent: visible red 1.5-inch focus 12 to 28V ac/dc p. 12SMA915CV Convergent: visible red 1.5-inch focus 90 to 130V ac p. 12SMB915CV Convergent: visible red 1.5-inch focus 210 to 250V ac p. 12
SMW915F Fiber optic: glass fibers see specs 12 to 28V ac/dc p. 13SMA915F Fiber optic: glass fibers see specs 90 to 130V ac p. 13SMB915F Fiber optic: glass fibers see specs 210 to 250V ac p. 13
SMW915FP Fiber optic: plastic fibers see specs 12 to 28V ac/dc p. 13SMA915FP Fiber optic: plastic fibers see specs 90 to 130V ac p. 13SMB915FP Fiber optic: plastic fibers see specs 210 to 250V ac p. 13
990 Series SMA91E & SMA99R Opposed: long range 200 feet* p. 15SMA91ESR & SMA99RSR Opposed: narrow beam 10 feet* p. 15
SMA990LV Retroreflective: visible beam 30 feet p. 15SMA990LVAG Retroreflective: polarized beam 15 feet p. 15SMA990LT Retroreflective: infrared beam 30 feet p. 16
(used for "people counting")
SMA990CV Convergent beam: visible red 1.5-inch focus p. 16
SMA990F Fiber optic: glass fibers see specs p. 17SMA990FP Fiber optic: plastic fibers see specs p. 16
Sensors withinfinite-lifesolid-state outputrelay
*NOTE: Emitter voltage range is 10-250V ac or dc
3Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: [email protected]
-
7/30/2019 Banner VALU BEAM Series Sensors
32/48
dc sensor specifications ac sensor specifications
Dimension Drawing,Front View
VALU-BEAM 912 Series Sensors
4
Rear View
Functional Schematic: SM912 Series DC Sensors Functional Schematic: SM2A912 Series AC Sensors
SUPPLY VOLTAGE: 24 to 250V ac (50/60Hz), except for SMA91E,ESR, and EF emitters, which operate from 10 to 250V ac or dc.
OUTPUT CONFIGURATION: solid-state switching element.
OUTPUT RATING: min. load current 10mA; max. steady-state loadcapability 750mA to 50 C ambient (122 F), 500mA to 70 C ambient(158 F). Inrush capability 4 amps for 1 sec. (non-repetitive). Off-stateleakage current less than 1.7mA rms. On-state voltage drop 5 voltsrms at 750mA load, 10 volts rms at 15mA load.
OUTPUT PROTECTION: protected against false pulse on power-up and inductive load transients.
RESPONSE TIME: 8 milliseconds ON, 8 milliseconds OFF (exceptreceiver-only units, which are 8 ms ON and 4 ms OFF). OFF time doesnot include load response of up to 1/2 ac cycle (8.3 milliseconds).Independent of si