Ballast Discharge and stripping while Loading
VENT HEADER
INERT GAS HEADER
CONDENSATE RETURN LINE
LIQUID HEADER
Reliquefaction
VapourCompressor
L.P.G.Vaporizer
Inert Gas Generator
L.P.G.Heater
Air Blower
VAPOUR HEADER
liquid vapour
Cargo Refrigeration / Re-liquefaction at sea
Cargo refrigiration at sea• By reliquefaction plant
• Not to run compressor during heavy rolling
• Condensate is passed through the top sprayes –cooling down the liquid surface (the bulk of the liquid has not been cooled)
• To cool down bulk of the liquid condensate return should be through the bottom connection of the tank to ensure proper circulation
Cargo refrigiration at sea
• Reliquefaction plant run on more than one tank simultaneosly – carefully controled condensate return (to avoid overfilling of any one tank)
• Draft
• Stress
• Trim
Ballast Management /Exchange
Always follow ballast plan
De-ballast tanks adjacent to tanks being loaded
Always check stress & stability at least hourly
Ballast Management
Pre Discharge line cooling
VENT HEADER
INERT GAS HEADER
CONDENSATE RETURN LINE
LIQUID HEADER
Reliquefaction
VapourCompressor
L.P.G.Vaporizer
Inert Gas Generator
L.P.G.Heater
Air Blower
VAPOUR HEADER
liquidvapour
Discharge without vapour return
Discharging• Method depend on type of ship, cargo
specification, terminal storage or bunker vesselcapacity.
• Discharge by pressurising the vapour space
–shore vapor suply or vaporiser and compressoron board
• Discharge with or without booster pumps
–discharging limited by pipeline diametar
–booster pump – for long distances or higherlevels
• Discharge via booster pump and cargo heater
–when discharged from refrigirated ship topressurised terminals
VENT HEADER
INERT GAS HEADER
CONDENSATE RETURN LINE
LIQUID HEADER
Reliquefaction
VapourCompressor
L.P.G.Vaporizer
Inert Gas Generator
L.P.G.Heater
Air Blower
VAPOUR HEADER
liquid vapour
Discharge with vapour return
Cryogenic pump flow system & use of inducer
Cryogenic pump
Spray Pump
A vertical, 3560 rpm centrifugal pump, with integral 440 V, 3 Phase, 60 Hz, 2 Pole, submersible 35 kW electrical motor.
The pump is configured, with a balance drum, as a fixed, in-tank, stripping and spray pump.
Start Discharge With Electric Ballast Pump
Discharge valve
Electric motor
Pump
1. Fill pipelines and pump
2. Start motor
3. Slowly open discharge valve