b series control panel installer quick start guide...you can also scan in the qr code. navigate to...

2
Location Item Description Specification A MODULE 1 Plug-in comm module Communication module options B ETHERNET Ethernet port built-in on-board Ethernet connection (10Base-T/100Base-T) C USB USB port USB connector (for firmware updates and RPS connection) D Heartbeat LED Slow=normal, rapid=service mode E Reset Reset switch Hold five seconds to enter or exit service mode F B C Outputs B(2) C(3) Open collector, 50mA, active low G TMPR Tamper Optional Tamper Switch Connector H 1 COM 2 to 7 COM 8 Alarm inputs 1k Ω EOL I R Y G B SDI2 bus SDI2 device bus J COM AUX Aux power 12 VDC, 800mA K NO C NC Output A(1) Programmable relay output L + BAT – 18 VAC, Battery, Earth ground, 18 VAC Primary/Secondary power and Earth Ground connections M Mounting Mounting holes Mounting holes for Control panel Control panel connection location B Series Control Panel Installer Quick Start Guide Use this guide to quickly install a B6512/B5512/B4512/B3512 Bosch security system. Additional information is found in the Control Panel Installation & System Reference Guide. For Additional Training: B Series Overview: B Series Micro site: Bosch YouTube Channel: When you see this icon; use your smart phone with a QR code reader app to view helpful videos. A B C D E F G H I J K L M Control panel component layout R Y G B 7 C OM 8 C OUTPUT B 1 k End of L ine R e si s t o r s V ol t age R ang e s ON-B O ARD POIN T S 3.7 - 5.0 VDC 2.0 - 3.0 VDC 0.0 - 1.3 VDC Open N o r mal Sho r t 3 C OM 4 5 C OM 6 1 C OM 2 R Y G B SDI2 D e vice Bus A UX - 12 V + TMPR 1 COM 2 7 COM 8 3 COM 4 5 COM 6 RESET COM AUX R Y G B PWR A B COM B C OUTPUT R Y G B Step 1 Mounting the control panel • Mount the enclosure prior to mounting the control panel. • Mount control panel into enclosure with hardware provided. Bosch Tips: B10 B11 Step 4 Installing expansion modules Bosch Tips: M M I I Step 7 Powering the control panel Bosch Tips: L L Bosch Tips: • Insert leg of module into slot marked “x.” • Cellular: Place antenna on top of enclosure and run cable inside, then connect to module. • PSTN: Connect module to a D166 (RJ31x) jack using a D161/D162 cable. Step 2 Installing a communication module A A Step 3 Installing a keypad Bosch Tips: I I • If installing a B942 or B915, refer to keypad installation guide for wiring diagrams. • If installing more than one keypad, refer to keypad installation guide for unique address settings. R Y G B 7 C OM 8 C OUTPUT B 1 k End of L ine R e si s t o r s V ol t age R ang e s ON-B O ARD POIN T S 3.7 - 5.0 VDC 2.0 - 3.0 VDC 0.0 - 1.3 VDC Open N o r mal Sho r t 3 C OM 4 5 C OM 6 1 C OM 2 R Y G B SDI2 D e vice Bus A UX - 12 V + TMPR 1 COM 2 7 COM 8 3 COM 4 5 COM 6 COM AUX R Y G B PWR A B COM B C OUTPUT • If installing more than one device that is similar, refer to the modules installation guide for address settings (for example, two of the same device). • If installing a RADION B810 wireless receiver, use address 1 only. Step 6 Installing a bell or siren Bosch Tips: Step 5 Installing wired inputs H H • If using a dual EOL, 2K EOL, or No EOL, refer to control panel installation guide for control panel settings. • If using 2-wired powered devices, use a B201 or D125B. Bosch Tips: NO EOL NC 7 C OM 8 C OUTPUT B 1 k End of L ine R e si s t o r s V ol t age R ang e s ON-B O ARD POIN T S 3.7 - 5.0 VDC 2.0 - 3.0 VDC 0.0 - 1.3 VDC Open N o r mal Sho r t 3 C OM 4 5 C OM 6 1 C OM 2 R Y G B SDI2 D e vice Bus A UX - 12 V + TMPR 1 COM 2 7 COM 8 3 COM 4 5 COM 6 RESET COM AUX R Y G B PWR A B COM B C OUTPUT K K J J • Connect wires to control panel before applying battery or AC power. • Connect Earth Ground to a cold water pipe (copper) or other solid connection to ground. Location Location Location Location Location Location Location Location Location Location Location Location Location Location Plug-in modules (B430/B44x) B201 Power Loop module • Output A can supply up to 1 amp at 12 VDC when sourced from a control panel (Jumper in AUX PWR position). • Output A can support up to 3 amps at 12 VDC when using a separate power supply (Jumper in DRY position). • Output B and C are open collector and are limited to 50 mA at 12 VDC. + Step 8 Creating control panel accounts Keypad programming • Follow Account Assistant instructions within RPS v6.03 or later to create control panel accounts. • If RPS is not available, Keypad Programming is an option. Refer to Installation Instructions. Battery Step 9 Connecting the control panel Bosch Tips: B B Location Location RPS/USB connection TMPR 7 COM 8 RESET ETHERNET B C OUTPUT 7 C OM 8 C OUTPUT B USB ETHERNET 100BASE - T LINK Or • Connect a computer with Remote Programming Software (RPS) installed. Connecting to RPS can be done through the use of a USB or Ethernet connection. • Launch RPS 6.03 or greater. The Account Assistant automatically launches when you create a new account. • For USB direct connect use a B99 USB cable. C C RPS/IP Direct connection through Onboard Ethernet B Series Wiring Basics:

Upload: others

Post on 24-Jul-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: B Series Control Panel Installer Quick Start Guide...You can also scan in the QR code. Navigate to the Knowledge Base link as shown in the adjacent illustration. (B942 is keypad shown)

Location Item Description Specifi cation

A MODULE 1Plug-in comm

moduleCommunication module options

B ETHERNET Ethernet port built-in on-board Ethernet connection (10Base-T/100Base-T)

C USB USB port USB connector (for fi rmware updates and RPS connection)

D Heartbeat LED Slow=normal, rapid=service mode

E Reset Reset switch Hold fi ve seconds to enter or exit service mode

F B C Outputs B(2) C(3) Open collector, 50mA, active low

G TMPR Tamper Optional Tamper Switch Connector

H1 COM 2 to

7 COM 8Alarm inputs 1k Ω EOL

I R Y G B SDI2 bus SDI2 device bus

J COM AUX Aux power 12 VDC, 800mA

K NO C NC Output A(1) Programmable relay output

L+ BAT –

18 VAC, Battery, Earth

ground, 18 VACPrimary/Secondary power and Earth Ground connections

M Mounting Mounting holes Mounting holes for Control panel

Control panel connection location

B Series Control PanelInstaller Quick Start Guide

Use this guide to quickly install a B6512/B5512/B4512/B3512 Bosch security system. Additional information is found in the Control Panel Installation & System Reference Guide.

For Additional Training:

B Series Overview:

B Series Micro site:

Bosch YouTube Channel:

When you see this icon; use your smart phone with a QR code reader app to view helpful videos.

A

B

CDE

F

G

HIJKL

M

Control panel component layout

R

Y

G

B

7 COM 8

COUTPUT

B

1 k End of Line Resistors

Voltage RangesON-BOARD POINTS

3.7 - 5.0 VDC2.0 - 3.0 VDC0.0 - 1.3 VDC

Open Normal Short

3 COM 4 5 COM 61 COM 2

R Y G B

SDI2Device Bus

AUX- 12 V + TM

PR

1 COM 2 7 COM 83 COM 4 5 COM 6

RES

ET

COM AUX R Y G BPWR A B COM

B

C

OU

TPU

T

RYGB

Step 1 Mounting the control panel

• Mount the enclosure prior to mounting the control panel.• Mount control panel into enclosure with hardware provided.

Bosch Tips:

B10

B11

Step 4 Installing expansion modules

Bosch Tips:

MM

II

Step 7 Powering the control panel

Bosch Tips:

LL

Bosch Tips:• Insert leg of module into slot marked “x.”• Cellular: Place antenna on top of enclosure

and run cable inside, then connect to module.

• PSTN: Connect module to a D166 (RJ31x) jack using a D161/D162 cable.

Step 2 Installing a communication module AA Step 3 Installing a keypad

Bosch Tips:

II

• If installing a B942 or B915, refer to keypad installation guide for wiring diagrams.

• If installing more than one keypad, refer to keypad installation guide for unique address settings.

RYGB

7 COM 8

COUTPUT

B

1 k End of Line Resistors

Voltage RangesON-BOARD POINTS

3.7 - 5.0 VDC2.0 - 3.0 VDC0.0 - 1.3 VDC

Open Normal Short

3 COM 4 5 COM 61 COM 2

R Y G B

SDI2Device Bus

AUX- 12 V + TM

PR

1 COM 2 7 COM 83 COM 4 5 COM 6COM AUX R Y G BPWR A B COM

B

C

OU

TPU

T

• If installing more than one device that is similar, refer to the modules installation guide for address settings (for example, two of the same device).

• If installing a RADION B810 wireless receiver, use address 1 only.

Step 6 Installing a bell or siren

Bosch Tips:

Step 5 Installing wired inputs HH

• If using a dual EOL, 2K EOL, or No EOL, refer to control panel installation guide for control panel settings.

• If using 2-wired powered devices, use a B201 or D125B.

Bosch Tips:

NOEOL

NC

7 COM 8

COUTPUT

B

1 k End of Line Resistors

Voltage RangesON-BOARD POINTS

3.7 - 5.0 VDC2.0 - 3.0 VDC0.0 - 1.3 VDC

Open Normal Short

3 COM 4 5 COM 61 COM 2

R Y G B

SDI2Device Bus

AUX- 12 V + TM

PR

1 COM 2 7 COM 83 COM 4 5 COM 6

RES

ET

COM AUX R Y G BPWR A B COM

B

C

OU

TPU

T

KKJJ

• Connect wires to control panel before applying battery or AC power.• Connect Earth Ground to a cold water pipe (copper) or other solid

connection to ground.

LocationLocation LocationLocation LocationLocation

LocationLocation LocationLocation LocationLocation

LocationLocation

Plug-in modules(B430/B44x)

B201 PowerLoop module

• Output A can supply up to 1 amp at 12 VDC when sourced from a control panel (Jumper in AUX PWR position).

• Output A can support up to 3 amps at 12 VDC when using a separate power supply (Jumper in DRY position).

• Output B and C are open collector and are limited to 50 mA at 12 VDC.

+

Step 8 Creating control panel accounts

Keypadprogramming

• Follow Account Assistant instructions within RPS v6.03 or later to create control panel accounts.

• If RPS is not available, Keypad Programming is an option. Refer to Installation Instructions.

Battery

Step 9 Connecting the control panel

Bosch Tips:

BBLocationLocation

RPS/USB connection

TMPR

7 COM 8

RES

ETET

HER

NET

B

C

OU

TPU

T

7 COM 8

COUTPUT

B

USB

ETHERNET100BASE-T

LINK Or

• Connect a computer with Remote Programming Software (RPS) installed. Connecting to RPS can be done through the use of a USB or Ethernet connection.

• Launch RPS 6.03 or greater. The Account Assistant automatically launches when you create a new account.

• For USB direct connect use a B99 USB cable.

CC

RPS/IP Direct connectionthrough Onboard Ethernet

B Series Wiring Basics:

Page 2: B Series Control Panel Installer Quick Start Guide...You can also scan in the QR code. Navigate to the Knowledge Base link as shown in the adjacent illustration. (B942 is keypad shown)

Bosch Security Systems, Inc.

130 Perinton Parkway

Fairport, NY 14450

USA

www.boschsecurity.com

B Series Control PanelInstaller Quick Start Guide

© 2017 Bosch Security Systems, Inc. F.01U.324.620 | 02 | 2017.01

• Perform a Walk Test.• Send a test report

After system installation and control panel programming, perform a complete system test. A complete system test includes testing the control panel, all devices, and communication destinations for proper operation.

FAQs

Step 12

Bosch Tips:

Disconnect from RPS and test the system

Step 10

Bosch Tips:

• Press Send from the Account Assistant when program is ready.

Send program to control panel

Step 11

Bosch Tips:

Entering Classic Mode in RPS

• Switch to Classic Mode if your system requires further programming such as using multiple areas. After programming changes, repeat step 10.

Test Menu

Notification Test

Revisions

Test Report

Walk Test

• Press Disconnect from control panel when programming is complete.

B520 AUX Power Supply CX4010* 18VAC Transformer

TR1850* 18VAC Transformer

B450 Remote Cellular Interface

RFBT Billtrap Transmitter

RFDL–11 PIR Microwave TriTech35 x 25 ft.

RFPR–12 PIR, Pet Immune 40 ft.

RFDW–RM Recessed Door/Window Contact

RFDW–SM Surface Mount Door/Window Contact

RFGBGlass Break Detector

RFUNUniversal Transmitter w/ Door/Window Contact

RFSM Wireless Smoke Detector

RFPR–C12Curtain PIR, Pet Immune 40 x 5 ft.

RFPB–SBRFPB–TB1 & 2 Button Panic

RFKF–TBSRFKF–FBS2 & 4 Button Keyfobs

RADION Wireless Devices

Power Communicators

RFID Tags for Readers & B942 KepadsACA–ATR13 ACD–ATR14CSACD–ATR11ISO

B810 SDI2 Wireless Receiver RFRP Wireless Repeater

IP Camera Integration

Any Bosch IP camera

D1218 18Ah Battery

D135A Low-Battery Disconnect Module

DS9370/DS9371360TriTech 70 ft.

ISC–BDL2–WP12G/WP6G/W12G TriTech40 X 40 ft./20 x 20 ft./ 40 x 40 ft.

Classic Series

B430 Telephone (PSTN)

D192G Bell Super Vision Module

D125B Dual Class B Initiating Module

B201 2–wire powered loop

F220/F220–B6RSmoke Detector plus Base

D132A Reversing Relay

Residential Fire

B56 Keypad Backbox

Enclosures & Accessories

D137 Mounting Bracket

D138 Mounting BracketRight Angle

ICP–EZTS Universal Tamper

B10 Medium Enclosure

B11 Small Enclosure

B208 Octo-Input Module

B308 Octo-Output Module

I/O Expansion Modules

ISC–CDL1–W15xTriTech50 ft.

Wired Motion Detectors

Commercial Series

Blue Line Gen2 Series

*Country Specifi c variants will apply

B440–C Cellular (Verizon 3G CDMA)

B441–C Cellular (Verizon CDMA)

B443 Cellular (HSPA+ SIM Required)

D5500CURPS Upgrade

Programing and Software

Remote Security Control Mobile App

B99 USB Cable

*Automation

Remote Security Plus Mobile App

G100 Z-Wave Home Control Gateway

Inovonics Wireless Devices

EN4200 Serial Receiver

B820 Wireless Interface

D126 7Ah Battery

B930 Text w/ Soft Keys

B920 Text w/ Function Keys

Keypads

B915 Text B921C Capacitive Touch

B942 Touch Screen B942W Touch Screen

What is my default code?User Code: 123456Installer Code: 123

How do I use Output B and C?Outputs B and C are Open Collector Outputs. Wiring can be found in control panel installation manual, section heading Open Collector Outputs.

How do you remotely turn on and turn off the control panel?This can be done through the use of the Remote Security Control App (RSC).

How do I connect directly to the control panel with Ethernet?By default, the control panel is set up to auto detect and negotiate a connection to RPS when an ethernet cable is connected between them.

What do I need to be able to send personal notifi cations?SMS (Text) messages require the use of a cellular module and emails can be sent by either an Ethernet or Cellular connection. How do I enter “Service Mode”?Press and hold the yellow reset button on the control panel for 5 seconds (repeat to exit).

Control panel

Access Modules(B6512 only)B901Access Module

B Series Control Panel Accessories (partial list)

Where can I go for additional help?

For additional help, tips and other useful information, visit the Security Knowledge Base link on our website.Go to: http://us.boschsecurity.comYou can also scan in the QR code.Navigate to the Knowledge Base link as shown in the adjacent illustration.

(B942 is keypad shown)

D101 Lock and Key set

us.boschsecurity.com

ISC–CDL1–WA15xTriTech+ w/Anti-Mask50 ft.

Note: Not all products and features are available in all regions. Consult your Bosch representative or product datasheets for details.

*Home automation may not be available in all regions. Consult your Bosch representative for details.

-A versions of RADION devices are used in North and South America. Non -A versions are used in Europe, Africa, and Australia.

B442 Cellular (GPRS SIM Required)