1
733.3 496 RADIATOR MATRIX 530 RADIATOR MATRIX 650 12v LEAD ACID BATTERY BATTERY TRAY 10 325 200 625 (FIXING HOLE CRS) 625 (FIXING HOLE CRS) 200 507.5 625 517.5 1650 OVERALL LENGTH 1343.3 OVERALL SHIPPING HEIGHT 1380.8 HEIGHT TO TOP OF BELLOWS FLANGE ANTI VIBRATION MOUNTS ALTERNATOR AIR FILTER 2.5" EXHAUST OUTLET SPLIT CUFF TO SUIT 76.1 O/D STEEL TUBE ANTI VIBRATION MOUNTS FORK POCKETS FUEL DRAIN BOSS 575 FIXING HOLE CRS 650 520 838.5 CONTROL PANEL 1358.5 398 CONTROL PANEL CONTROL BREAKER PANEL CABLE GLAND ACCESS 461 EXHAUST OUTLET 115.2 EXHAUST OUTLET 3 OFF OPTION BOSSES LOCATED 3 PLACES ON TANK TOP LID FUEL GAUGE & FUEL FILL CAP LOCATED ON TANK TOP LID C I RUTTER 28/02/2013 S BEAN 28/02/2013 3029DF128 OPEN FRAME 1 SALES ASSY (50 Hz) B Alternator Changed from BCI184 to PI144 SJB 7/9/10 P RUTTER FOR INDIVIDUAL GEN SET MODEL TYPES SEE BROADCROWN LITERATURE ENGINE TYPE: 3029DF128 USEABLE FUEL CAPACITY: (INTEGRAL) 88L (BUNDED) 72L OIL CAPACITY: 6 LITRES COOLING CAPACITY: 14.5 LITRES GENERATOR IS TO BE PLACED ON A FLAT FLOOR OE CONCRETE BASE 28/02/13 IWR DWG UPDATED TO SHOW ALL ENGINE / ALTERNATOR COMBINATIONS C GEN SET MODEL ENGINE ALTERNATOR DRY WEIGHT (Kg) WET WEIGHT (Kg) BCJD 22-50 3029DF128 PI 144D 649 735 BCJD 30-50 3029DF128 PI 144F 672 758 BCJD 15-50SP 3029DF128 PI 144D 649 735 BCJD 20-50SP 3029DF128 PI 144F 672 758 BCJD 22-50SP 3029DF128 PI 144G 689 775 NOTES - MECHANICAL TOLERANCES: GENERAL TOLERANCES: +/- 5mm FABRICATION: +/- 3mm HOLE CENTRES: +/- 1mm OTHER TOLERANCES AS OTHERWISE STATED WHERE REQUIRED GEOMETRICAL AND OTHER TOLERANCES AS STATED. A B C D E F G H 1 2 3 4 5 6 7 8 DRAWING No: CREATED BY: DATE: DATE: MODIFYED BY: DESCRIPTION REV DETAILS APP'D DATE SHEET 1 of 1 THIRD ANGLE PROJECTION ISSUE: FINISH: MATERIAL: JGA026 CHECKED BY: DATE: REQUEST A QUOTE [email protected] CALL US TODAY 1-888-POWER-58 SHOP ONLINE www.genpowerusa.com/brands/JOHN-DEERE-Generators

Upload: others

Post on 16-Oct-2021

3 views

Category:

Documents


0 download

TRANSCRIPT

733

.3

496

RA

DIA

TOR

MA

TRIX

530 RADIATORMATRIX

650

12v LEADACID BATTERY

BATTERYTRAY

10

325

200 625 (FIXING HOLE CRS) 625 (FIXING HOLE CRS) 200

507.5 625 517.5

1650 OVERALL LENGTH

134

3.3

OV

ER

ALL

SH

IPP

ING

HE

IGH

T

138

0.8

HE

IGH

T TO

TO

P O

F B

ELL

OW

S F

LAN

GE

ANTIVIBRATIONMOUNTS

ALTERNATOR

AIR FILTER

2.5" EXHAUST OUTLETSPLIT CUFF TO SUIT76.1 O/D STEEL TUBE

ANTIVIBRATIONMOUNTS

FORK POCKETS

FUEL DRAIN BOSS

575 FIXING HOLE CRS

650

520

8

38.5

CO

NTR

OL

PA

NE

L

135

8.5

398

CONTROLPANEL

CONTROL BREAKERPANEL

CABLE GLANDACCESS

461 EXHAUSTOUTLET

115.

2 E

XH

AU

ST

OU

TLE

T

3 OFF OPTION BOSSES LOCATED3 PLACES ON TANK TOP LID

FUEL GAUGE & FUEL FILL CAPLOCATED ON TANK TOP LID

C

I RUTTER

28/02/2013S BEAN

28/02/2013

3029DF128 OPEN FRAME 1SALES ASSY (50 Hz)

B Alternator Changedfrom BCI184 to PI144

SJB 7/9/10

P RUTTER

FOR INDIVIDUAL GEN SET MODEL TYPES SEE BROADCROWN LITERATURE

ENGINE TYPE: 3029DF128

USEABLE FUEL CAPACITY: (INTEGRAL) 88L (BUNDED) 72L

OIL CAPACITY: 6 LITRES

COOLING CAPACITY: 14.5 LITRES

GENERATOR IS TO BE PLACED ON A FLATFLOOR OE CONCRETE BASE

28/02/13IWRDWG UPDATED TOSHOW ALL ENGINE /ALTERNATORCOMBINATIONS

CGEN SET MODEL ENGINE ALTERNATOR DRY WEIGHT (Kg) WET WEIGHT (Kg)

BCJD 22-50 3029DF128 PI 144D 649 735

BCJD 30-50 3029DF128 PI 144F 672 758

BCJD 15-50SP 3029DF128 PI 144D 649 735

BCJD 20-50SP 3029DF128 PI 144F 672 758

BCJD 22-50SP 3029DF128 PI 144G 689 775

NOTES - MECHANICALTOLERANCES:

GENERAL TOLERANCES: +/- 5mmFABRICATION: +/- 3mmHOLE CENTRES: +/- 1mmOTHER TOLERANCES AS OTHERWISE STATED WHERE REQUIRED

GEOMETRICAL AND OTHER TOLERANCES AS STATED.

A

B

C

D

E

F

G

H

1 2 3 4 5 6 7 8

DRAWING No:

CREATED BY:

DATE:

DATE:

MODIFYED BY:

DESCRIPTION

REV DETAILS APP'D DATE

SHEET 1 of 1

THIRD ANGLE PROJECTION

ISSUE:

FINISH:

MATERIAL:

JGA026

CHECKED BY:DATE:

REQUEST A QUOTE [email protected]

CALL US TODAY 1-888-POWER-58

SHOP ONLINE www.genpowerusa.com/brands/JOHN-DEERE-Generators