b alternator changed for individual gen set model types
TRANSCRIPT
733
.3
496
RA
DIA
TOR
MA
TRIX
530 RADIATORMATRIX
650
12v LEADACID BATTERY
BATTERYTRAY
10
325
200 625 (FIXING HOLE CRS) 625 (FIXING HOLE CRS) 200
507.5 625 517.5
1650 OVERALL LENGTH
134
3.3
OV
ER
ALL
SH
IPP
ING
HE
IGH
T
138
0.8
HE
IGH
T TO
TO
P O
F B
ELL
OW
S F
LAN
GE
ANTIVIBRATIONMOUNTS
ALTERNATOR
AIR FILTER
2.5" EXHAUST OUTLETSPLIT CUFF TO SUIT76.1 O/D STEEL TUBE
ANTIVIBRATIONMOUNTS
FORK POCKETS
FUEL DRAIN BOSS
575 FIXING HOLE CRS
650
520
8
38.5
CO
NTR
OL
PA
NE
L
135
8.5
398
CONTROLPANEL
CONTROL BREAKERPANEL
CABLE GLANDACCESS
461 EXHAUSTOUTLET
115.
2 E
XH
AU
ST
OU
TLE
T
3 OFF OPTION BOSSES LOCATED3 PLACES ON TANK TOP LID
FUEL GAUGE & FUEL FILL CAPLOCATED ON TANK TOP LID
C
I RUTTER
28/02/2013S BEAN
28/02/2013
3029DF128 OPEN FRAME 1SALES ASSY (50 Hz)
B Alternator Changedfrom BCI184 to PI144
SJB 7/9/10
P RUTTER
FOR INDIVIDUAL GEN SET MODEL TYPES SEE BROADCROWN LITERATURE
ENGINE TYPE: 3029DF128
USEABLE FUEL CAPACITY: (INTEGRAL) 88L (BUNDED) 72L
OIL CAPACITY: 6 LITRES
COOLING CAPACITY: 14.5 LITRES
GENERATOR IS TO BE PLACED ON A FLATFLOOR OE CONCRETE BASE
28/02/13IWRDWG UPDATED TOSHOW ALL ENGINE /ALTERNATORCOMBINATIONS
CGEN SET MODEL ENGINE ALTERNATOR DRY WEIGHT (Kg) WET WEIGHT (Kg)
BCJD 22-50 3029DF128 PI 144D 649 735
BCJD 30-50 3029DF128 PI 144F 672 758
BCJD 15-50SP 3029DF128 PI 144D 649 735
BCJD 20-50SP 3029DF128 PI 144F 672 758
BCJD 22-50SP 3029DF128 PI 144G 689 775
NOTES - MECHANICALTOLERANCES:
GENERAL TOLERANCES: +/- 5mmFABRICATION: +/- 3mmHOLE CENTRES: +/- 1mmOTHER TOLERANCES AS OTHERWISE STATED WHERE REQUIRED
GEOMETRICAL AND OTHER TOLERANCES AS STATED.
A
B
C
D
E
F
G
H
1 2 3 4 5 6 7 8
DRAWING No:
CREATED BY:
DATE:
DATE:
MODIFYED BY:
DESCRIPTION
REV DETAILS APP'D DATE
SHEET 1 of 1
THIRD ANGLE PROJECTION
ISSUE:
FINISH:
MATERIAL:
JGA026
CHECKED BY:DATE:
REQUEST A QUOTE [email protected]
CALL US TODAY 1-888-POWER-58
SHOP ONLINE www.genpowerusa.com/brands/JOHN-DEERE-Generators