ayyeka wavelet schematic wavelet 4r...may 05, 2020  · the wavelet protector above the connector...

18
QUICK START GUIDE WAVELET 4R April 2020 P/N 0100711 Rev 1 AYYEKA

Upload: others

Post on 04-Mar-2021

7 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

QUICK START

GUIDE

WAVELET 4R

April 2020

P/N 0100711 Rev 1

AYYEKA

AYYEKA WAVELET SCHEMATIC

External (Bottom)

Page 2: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

3

It is important that you read the Quick Start Guidein a controlled environment prior to installation.

Set up, activate, and successfully test the entiresystem (Wavelet 4R, sensors, and antennaconnection) indoors, in a controlled environment,before going to the field for installation.

!

Page 3: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

1

IMPORTANT

Contact AYYEKA SUPPORT for technical support: [email protected] +1 (310) 876-8040 (US) +31 40 209-1001 (EMEA)

ALWAYS COORDINATE Basic Wavelet Kit installation with the local authority before starting installation works, which should be completed by trained and authorized personnel.

The WARRANTY offered by Ayyeka covers only Ayyeka supplied hardware and software for the duration of the warranty period as per the warranty terms and conditions.

AYYEKA IS NOT LIABLE for damage or injury as a result of handling, installation, or maintenance of its supplied systems.

DO NOT THROW AWAY the Basic Wavelet Kit, as it contains a lithium battery. Please dispose of properly.

CELLULAR NETWORK SIGNAL is required for proper communication.

OPERATING TEMPERATURE RANGE of -40°C to -80°C (-40°F to -176°F).

Page 4: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

2

AYYEKA WAVELET SCHEMATIC

External (Bottom)

SCHEMATIC

BOTTOM

Cellular

Sensor Input Port

17.4

cm

(6.9

in)

13.3 cm (5.2 in)

7.3

cm

(2.8

in)

AYYEKA

AYYEKA WAVELET SCHEMATIC

External (Bottom)

Page 5: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

3

TURN HERE

DO NOT TURN HERE

GETTING STARTED

GETTING STARTED

BASIC WAVELET KIT

1 2

3 4

Wavelet Device & Protector

M12 Field Attachable Sensor Connector (optional; Ordered separately)

Wavelet Activator

1x

GETTING STARTED

1x1x

1x1x

M8 Female Field Attachable Power Connector (optional; see page 16)

Page 6: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

4

Other tools and/or materials may be required (not included):

Electric Screw DriverRotary Hammer

5 6Zip Ties, Screws, and Anchors

Cellular Antenna (REQUIRED; ordered separately)

4x2x 4x

GETTING STARTED

Page 7: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

5

NOTE: Special Installation Locations

WEAK SIGNAL LOCATIONS:

If the Wavelet is installed in an area with weak cellular signal, activate the Wavelet and place in the intended installation location with closed doors/access hatch (see step 3).

Log in to home.ayyeka.com to ensure that cellular signal has been recently updated in the last few minutes.

UNDERGROUND/INDOOR WAVELET INSTALLATIONS:

Make sure the cellular antenna is properly installed to provide adaquate signal quality

Wait for at least 15 minutes, then log in to the user interface at home.ayyeka.com to make sure stable communication is confirmed

Page 8: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

6

7

TURN HERE

DO NOT TURN HERE

7

TURN HERE

DO NOT TURN HERE

Connect the sensor cable assembly with the field attachable connector to the mating panel connector on the Wavelet. Turn the adjustable stainless steel end piece to secure the field attachable connector to the Wavelet.

1

CAUTION: Do not turn the black plastic hood of the connector. Turning the black hood may cause the wires to disconnect, break, and/or damage the connector pins.

SENSOR CONNECTION

Page 9: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

7

EXTERNAL ANTENNA CONNECTION

Connect the cellular antenna to the antenna port (ANT 1).2

WAVELET ACTIVATION

Place the magnetic Wavelet Activator on the embossed Ayyeka logo on the front of the Wavelet enclosure. Wavelet will initiate a 15 minute test mode of high frequency sampling and transmission. The device will then return to its default configuration.

3

IMPORTANT NOTE: The antenna does not appear in the remaining depictions in this guide, but should remain connected once properly secured to the appropriate panel connectors.

Cellular Antenna

Page 10: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

8

WAVELET ACTIVATION

Verify the installation with your mobile phone by using AyyekaGo mobile application.

If you haven’t already done so, download the AyyekaGo mobile app for iOS or for Android. Search the App Store or Google Play for “AyyekaGo” or use the QR codes below

There are two ways to pair your phone with your Wavelet:

1. Select ”Get Key Via Web”. This will direct you to enter your log-in credentials for the StreamView user interface.

2. Select ”Enter Key Manually”. The Mobile Pair Key is found in the StreamView user interface in the Devices tab.

4

Access the Ayyeka user interface at home.ayyeka.com using your log-in credentials. Expect data to appear between 5 – 10 minutes after the test mode is initiated.

5

Page 11: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

9

WAVELET ACTIVATION

6 The screen display should resemble the following:

If the Wavelet is transmitting properly, you have completed the installation successfully and can begin collecting and viewing your data!

If data does not transmit properly, change the Wavelet installation location and activate again (step 3). If the problem persists, contact Ayyeka for assistance. [email protected] +1 (310) 876-8040 (US) +31 40 209-1001 (EMEA)

Page 12: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

10

Attaching the protector

7 After the Wavelet completes the transmission process, place the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure.

CAUTION: The protector is provided to shield the connector from tampering or overexposure that could result in disconnected wiring.

GETTING STARTED

a. Insert the two lower clips into the two lower holes of the Wavelet enclosure.

b. Snap the upper clips into place in the two grooves above the panel connector.

Lower Clips

Upper Clips

a

b

Page 13: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

11

11

Secure the Wavelet on a wall, pipe, or other secure mounting location using zip ties or screws.

8

ORWall Mounted

Pipe Mounted

Page 14: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

12

YOUR WAVELET 4R IS NOW SUCCESSFULLY INSTALLED!

Page 15: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

13

WAVELET 4 – ANALOGANALOG – PANEL CONNECTOR #1 – M12 8-PIN MALE

Connector Pin # Function Name Pin Assignment

1 Signal+ 4-20mA or 0-24V Input #1 Front

2 Common Negative (-)

3 Supply+ Wavelet 12V Power Supply #2 (+)

4 Supply+ Wavelet 12V Power Supply #1 (+)

5 Signal+ 4-20mA or 0-24V Input #4

6 Signal+ 4-20mA or 0-24V Input #3

7 Signal+ 4-20mA or 0-24V Input #2

8 Common Negative (-)

+1 (310) 876-8040 (US) +31 (40) 209-1001 (EMEA) [email protected]

WAVELET PINOUT

PANEL CONNECTOR – M12 8-PIN MALEConnector Pin #

Function Description Pin Assignment

1 Signal 4-20mA or 0-24V Input #1 Front

2 Signal PCNT_0 – pulse counting, edge, periodic, output

Dry contact, open drain, 0V or 2.8V (max)

3 Signal RS485 A and RS232 RX

4 Supply Wavelet 12V Power Supply #1 (+)

5 Signal RS485 B and RS232 TX Back

6 Signal 4-20mA or 0-24V Input #2

AYYEKA WAVELET SCHEMATIC

External (Bottom)

#2

7 Signal PCNT_1 – pulse counting, edge, periodic, output

Dry contact, open drain, 0V or 2.8V (max)

8 Common GND

Page 16: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

14

GETTING STARTED

3 pos 4 pos

inner view ( 2 : 1 )

namedate

42K1A316

Strakerjahn26.07.11

16.09.11 Hüther

Female connector M8x1, fieldattachable , axial, screw termination

see table

Indndex: c 18.07.13 KH Ä4842Wire cross section adapted

3 1

Ø14

(RE

F. 4

0)

Ø13,7

Width across flats 13

Width across flats 12

Max. external cablediameter see table

Width across flats 13

4 2

13

Materials: Contact: Contact plating: Contact carrier: Cable sealing: O-Ring: Coupling nut: Housing:

CuZn Au over Niin mating area PA6, UL 94 NBR Silicone / NBR CuZn, Ni PA6 GF, UL 94

Installation specification for locking nutto counter connector: Recommendedtorque: Conec installation tool:

0,4 Nm Torque wrench: 36-000200Insert across flats 13: 36-000220

Description:

SAL - 8 - RKC3-S

Cable-:

4 - 5,5mm

SAL - 8 - RKC4-S 4 - 5,5mm

Part no:

42-00010

42-00012

Pos:

3

4

terminationØ1,9

Technical specification: Rated voltage:IEC 61076-2-104 Current rating:IEC 61076-2-104 Insulation resistance:IEC 60512 Pollution degree:IEC 60664-1 Degree of protection:IEC 60529 Temperature range:IEC 60664-1 Mating cycles:IEC 60512-9a Wire cross section:

3pos 4pos 60 V 30 V 4 A at 40°Cwith 0,5mm²

>= 100 MΩ 3/2 IP 67, in matedcondition -30°C ... +85°C >= 100 AWG 20 / max. 0,5 mm²

SW 0,9

Installation tool forwire termination( included )

4

M8 3-Pin Female Power Connector

Wire To Connect:Cable Wire Cross Section Surface Area

0.14 – 0.5 mm2

Wire Gauge AWG 26-20Cable Ø Diameter 4 – 5.5 mm

+ Installation Tool for Wire Termination (Included)

No Connection 5-28VDC (+)

Negative (-)

POWER CONNECTOR PINOUT

If using an external power source, refer to the pinout below:

EXTERNAL POWER:

4

3 1

POWER – PANEL CONNECTOR #4 – M8 3-PIN MALE

Connector Pin #

Function Description Pin Assignment

1 Supply+ 5-28VDC (+) Front

3 No Signal No Connection

4 Common Negative (-)

POWER – PANEL CONNECTOR #4 – M8 3-PIN MALE

Connector Pin # Function Name Pin Assignment

1 Supply+ 5-28VDC (+) Front

3 No Signal No Connection

4 Common Negative (-)

WAVELET 4 – POWER

43 1

+1 (310) 876-8040 (US) +31 (40) 209-1001 (EMEA) [email protected]

Page 17: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

15

NOTES

Page 18: AYYEKA WAVELET SCHEMATIC WAVELET 4R...May 05, 2020  · the Wavelet protector above the connector ports and secure the Wavelet protector into the Wavelet enclosure. CAUTION: The protector

www.ayyeka.com [email protected] +1 (310) 876-8040 (US) +31 40 209-1001 (EMEA)

QUESTIONS?