axc product description

24
7/28/2019 AXC Product Description http://slidepdf.com/reader/full/axc-product-description 1/24 ATM Cross-connect (AXU) Unit Description dn02178696 Issue 6 en # Nokia Corporation Nokia Proprietary and Confidential 1 (24) 469972A UltraSite and MetroSite WCDMA BTS Solutions, Rel2

Upload: carlo-doria-guingao

Post on 03-Apr-2018

226 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 1/24

ATM Cross-connect (AXU) Unit

Description

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

1 (24)

469972A

UltraSite and MetroSite WCDMA BTSSolutions, Rel2

Page 2: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 2/24

The information in this document is subject to change without notice and describes only theproduct defined in the introduction of this documentation. This document is intended for the useof Nokia's customers only for the purposes of the agreement under which the document issubmitted, and no part of it may be reproduced or transmitted in any form or means without theprior written permission of Nokia. The document has been prepared to be used by professionaland properly trained personnel, and the customer assumes full responsibility when using it.Nokia welcomes customer comments as part of the process of continuous development andimprovement of the documentation.

The information or statements given in this document concerning the suitability, capacity, or performance of the mentioned hardware or software products cannot be considered binding butshall be defined in the agreement made between Nokia and the customer. However, Nokia hasmade all reasonable efforts to ensure that the instructions contained in the document areadequate and free of material errors and omissions. Nokia will, if necessary, explain issueswhich may not be covered by the document.

Nokia's liability for any errors in the document is limited to the documentary correction of errors.NOKIA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENTOR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING MONETARYLOSSES), that might arise from the use of this document or the information in it.

This document and the product it describes are considered protected by copyright according tothe applicable laws.

NOKIA logo is a registered trademark of Nokia Corporation.

Other product names mentioned in this document may be trademarks of their respectivecompanies, and they are mentioned for identification purposes only.

Copyright © Nokia Corporation 2003. All rights reserved.

2 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 3: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 3/24

Contents

Contents 3

1 ATM cross-connect unit (AXU) unit operation and main blocks 51.1 Operation 61.2 Main blocks 7

2 AXU unit power requirements 11

3 AXU unit dimensions and weight 13

4 AXU unit interfaces 15

5 AXC LED indications 17

6 AXU traffic capacity 19

7 AXC units mean time between failures 21

8 AXC delays 23

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

3 (24)

Contents

Page 4: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 4/24

4 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 5: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 5/24

1 ATM cross-connect unit (AXU) unit

operation and main blocks

The ATM cross-connect unit (AXU) is the master unit of the AXC node and it 

controls the node within the Nokia WCDMA BTS. It cross-connects ATM traffic

within the BTS, and connects the BTS to other BTSs or to the Nokia Radio

 Network Controller (RNC). The AXU unit is always installed in the first slot of the AXC.

There are two AXU units available: AXUA and AXUB. AXUB provides the

centralised BTS AAL2 multiplexing feature. It is enabled by the ATM Adaptation

Module (AAM) of the AXUB unit.

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

5 (24)

 ATM cross-connect unit (AXU) unit operation and main blocks

Page 6: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 6/24

Figure 1. AXU unit

1.1 Operation

The following features are available with the AXU units:

. semi-permanent ATM cross-connections on Virtual Path (VP) and Virtual

Channel (VC) level providing connections between Wideband Application

Manager (WAM) units and thus interconnecting different sectors inside the

BTS, and providing a connection from the BTS to the RNC through the I ub

interface and further connections between other base stations and the RNC.

. reference clock recovered either from a physical interface, or received from

an external timing source, or from an internal reference source and

 provided for all the transmission interface units, and for BTS

synchronisation and BTS clock unit (WSC).

LED

LMP

Q1

ERC2

Lever 

Lever 

ERC1

Microcontroller 

module

Power 

module

AAM-Module (AXUB)

6 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 7: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 7/24

. management functionality of the AXC node for passing network 

management system information to the base station and vice versa. The

Local Management Port (LMP) is available on the AXU front panel for 

local management of AXC and BTS or remote management of other 

network elements.

. up to 1.2 Gbit/s ATM switching capacity

. 1000 simultaneous connections supported

. BTS AAL2 multiplexing of the AXUB unit for multiplexing AAL2

connections between WAMs and RNC into one or several VCCs

1.2 Main blocks

The AXU unit includes the following functional blocks:

. Control Unit 

. Clock Distribution Circuit 

. ATM Switch Fabric

. AAM (in AXUB)

. Backplane Bus Adaptation

.

DC/DC Converter 

The Functional blocks of the AXU unit  figure shows the block diagram of the

AXU unit.

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

7 (24)

 ATM cross-connect unit (AXU) unit operation and main blocks

Page 8: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 8/24

Figure 2. Functional blocks of the AXU unit

Control Unit

The Control Unit consists of the Microcontroller and other necessary circuitry. It 

is compiled on a module that is the same in each AXC unit. The module type is sogeneric that it meets all the requirements of each AXC unit.

The Microcontroller runs all unit control software on the AXC.

The Control Unit also features an IP router. Thus it provides a routing path for 

remote BTS management and enables the local management of the BTS via the

LMP of the AXC. Management of other BTSs via the IP router is also possible.

In addition the Control Unit features a Q1 management support function which

can be used to manage Q1 network elements remotely. The Q1 network elements

can be connected to the Q1 management support function by means of a cable

connected to the Q1 interface at the front panel of the AXU or by means of operation channels (EOC) embedded in some transmission signals. The Q1

management support function can be connected via the backplane to AXC

embedded Q1 network elements (IFUE).

Clock Distribution Circuit

The Clock Distribution Circuit provides a reference clock for all IFUs and the

WSC.

LED

LMP

Q1

ERC1/2

To/from

IFUX

To/from

WAM

DC input 

ATM

Switch

Fabric

Control

Unit 

Clock 

Distr.

Circuit 

     B   a    c 

     k   p  

     l   a    n   e 

     B   u    s 

     A     d 

   a    p  

    t  . 

DC/DC

Converter 

Inter-unit communication and

Q1 bus

Clock distribution

Q1

support 

function AAM

(AXUB)

8 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 9: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 9/24

The reference clock can either be recovered from a physical interface or received

from an external timing source, or from an internal reference source. The internal

clock is used if no external reference is available. In this case the AXC does not 

 provide a reference clock for the BTS, but the BTS's WSC provides the clock for 

the BTS. The AXU features two dedicated interfaces for external timing source

input.

ATM Switch Fabric

The ATM Switch Fabric performs all ATM layer functionalities of the AXC:

. Virtual Path and Virtual Channel cross-connection functionality for ATM

cells between a certain number of IFUs and WAMs

. header translation functionality for ATM connections

. traffic management functions like policing or traffic shaping

. O&M functionality (operations, administration and maintenance)

The total switching capacity of the block is 1.2 Gbit/s.

AAM (in AXUB)

The AXUB unit with the working AAL type 2 module (AAM) multiplexes or 

demultiplexes AAL type 2 connections between the WAMs and RNC into one or 

several VCCs.

Backplane Bus Adaptation

The Backplane Bus Adaptation provides serial payload backplane connections

 between the IFUs and the AXU by means of a bus, as well as the AXU and the

WAMs.

DC/DC Converter 

The DC/DC Converter transforms the input voltage of   48 V fed through the

 backplane to the voltages required at unit level.

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

9 (24)

 ATM cross-connect unit (AXU) unit operation and main blocks

Page 10: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 10/24

10 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 11: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 11/24

2 AXU unit power requirements

The tables below lists the DC power supply value and typical and maximum

 power consumption for AXUA and AXUB units.

Table 1. AXUA power supply and consumption

Property Property Value

DC power supply -37.5 to -60 V DC

Power consumption (typical) 35 W

Power consumption (max.) 40 W

Table 2. AXUB power supply and consumption

Property Property Value

DC power supply -37.5 to -60 V DC

Power consumption (typical) 38 W

Power consumption (max.) 43 W

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

11 (24)

 AXU unit power requirements

Page 12: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 12/24

12 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 13: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 13/24

3 AXU unit dimensions and weight

The tables below define the dimensions and weight of AXUA and AXUB units

Table 3. AXUA dimensions

Property Value

Height 264 mm

Width 25 mm

Depth 285 mm (incl. front panel)

Weight 800 g

Table 4. AXUB dimensions

Property Value

Height 264 mm

Width 25 mm

Depth 285 mm (incl. front panel)

Weight 900 g

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

13 (24)

 AXU unit dimensions and weight

Page 14: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 14/24

14 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 15: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 15/24

4 AXU unit interfaces

AXUA and AXUB interfaces

Interface Connector  

Local Management Port (LMP) 10baseT crossed Ethernet interface, RJ-45 connector 

Ethernet standards IEEE 802.3 and ANSI

8802.3, RFC 1483 (routed)

Q1 management port V.11 interface, D-sub 9 connector  

External reference clock interface 1 (ERC

1)

TQ connector (symmetrical), 110 ©

64 kHz + 8 kHz (AMI with 8 kHz bipolar 

violation)

External reference clock interface 2 (ERC

2)

Coaxial BT-43 connector, 75 ©

1.544 MHz, 2.048 MHz, 2 Mbit/s

Figure 3. ERC1 symmetrical interface

Local management port pinout (RJ-45 connector)

Pin Signal Explanation

1 TD+ Transmitted data +

2

341 Clock input -

2 Clock input +

3 nc

4 nc

1

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

15 (24)

 AXU unit interfaces

Page 16: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 16/24

Pin Signal Explanation

2 TD- Transmitted data -

3 RD+ Received data +

4 nc Not used by 10baseT

5 nc Not used by 10baseT

6 nc Not used by 10baseT

7 nc Not used by 10baseT

8 RD- Received data -

9 nc Not used by 10baseT

Nokia Q1 management interface pinout

Pin Signal Explanation

1 Q1_OUT_N Transmitted data -

2 nc Not connected

3 GND Ground

4 GND Ground

5 Q1_IN_N Received data -

6 Q1_OUT_P Transmitted data +

7 nc Not connected

8 nc Not connected

9 Q1_IN_P Received data +

16 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 17: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 17/24

5 AXC LED indications

The LEDs of the Nokia AXC-ATM cross-connect unit (AXU) and Interface Units

IFUA/IFUD, IFUB, IFUC and IFUE are presented in the following.

Front panel LEDs

Each of the Nokia AXC units has a 3-colour status LED located on the front  panel. These indicators display the current state of the equipment. The LEDs

indicate the following:

Table 5. LED indications (O/A/F1)

Colour Explanation

Stable red Major or critical alarm

or 

Unit disabled

Blinking red Minor alarm

Stable yellow Unit starting up

Stable green Normal operation, power on

Blinking green Software download from LMT or network

during operation

IFUE LEDs

The Interface Unit IFUE has two 3-colour status LEDs on the front panel

indicating the operational status of the unit: O/A/F1 and O/A/F2 (O/A/F signifies

Operation/Alarm/Fail). The O/A/F1 LED indicates the operational status of the

ATM part and the O/A/F2 LED indicates the operational status of the Flexbus

 part of the IFUE. In addition, each of the three Flexbus interfaces has a status

LED of its own (DC on).

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

17 (24)

 AXC LED indications

Page 18: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 18/24

. O/A/F1 (ATM part)

. O/A/F2 (Flexbus part)

.

DC on (Flexbus 1). DC on (Flexbus 2)

. DC on (Flexbus 3)

The following table shows the indications of the O/A/F2 multi-colour LED for 

the Flexbus part.

Table 6. IFUE O/A/F2 LED indications

Colour Status

Green The unit functions well, no alarms.

Yellow Alarms with low priority occur, e.g. the

node clock is not set

Red Some errors occur, e.g. LOS of FB1 or 

2M interface 3: Buffer overflow

The following table shows shows the indications of the DC on Flexbus LEDs.

Table 7. IFUE Status of DC on LED indications

Indication Status

Off Normal status, no remote power feeding.

Blinking Try to find an Outdoor Unit (OU), remote

power feeding is temporarily on.

On OU found and remote power feeding is

on.

18 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 19: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 19/24

6 AXU traffic capacity

Table 8. Capacity of AXUA

Property Value

Switching capacity 1.2 Gbit/s

Simultaneous connections 1000 (with any mix of VPs and VCs)

Supported ATM service categories Constant Bit Rate (CBR)

Unspecified Bit Rate (UBR)

 ATM Forum af-0056.000

Supported cross-connections semi-permanent Virtual Path Connections

(VPC)

semi-permanent Virtual Channel

Connections (VCC)

Table 9. Capacity of AXUB

Property Value

Switching capacity 1.2 Gbit/s

Simultaneous connections 1000 (with any mix of VPs and VCs)

Supported ATM service categories Constant Bit Rate (CBR)

Unspecified Bit Rate (UBR)

 ATM Forum af-0056.000

Supported cross-connections semi-permanent Virtual Path Connections

(VPC)

semi-permanent Virtual Channel

Connections (VCC)

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

19 (24)

 AXU traffic capacity

Page 20: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 20/24

Table 9. Capacity of AXUB (cont.)

Property Value

Supported AAL2 connections 1736

20 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 21: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 21/24

7 AXC units mean time between failures

Table 10. Mean time between failures (years)

Unit MTBF

 AXU 23 years

IFUA (symmetrical E1/JT1/T1) 28 years

IFUB (JT2) 28 years

IFUC (SDH/Sonet) 24 years

IFUD (E1 coaxial) 28 years

IFUE (Flexbus) 18 years

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

21 (24)

 AXC units mean time between failures

Page 22: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 22/24

22 (24) # Nokia CorporationNokia Proprietary and Confidential

dn02178696Issue 6 en

 ATM Cross-connect (AXU) Unit Description

Page 23: AXC Product Description

7/28/2019 AXC Product Description

http://slidepdf.com/reader/full/axc-product-description 23/24

8 AXC delays

Table 11. Estimated intrinsic delays

Interface type Estimated intrinsic delay/interface

STM-1 16 µs

STM-0 24 µs

E1 260 µs

JT1 316 µs

JT2 69 µs

IMA (n x E1) 800 µs

IMA (n x JT1) 1000 µs

Flexbus 30 µs

CBR Cross-connection 350 µs

UBR Cross-connection 0 µs

Table 12. Estimated generated Cell Delay Variation (CDV)

Interface CDV for CBR CDV for UBR

STM-1 12 µs 12 µs

STM-0 12 µs 12 µs

E1 660 µs 220 µs

JT-1 828 µs 276µs

IMA (2xE1) 120 µs 120 µs

dn02178696Issue 6 en

# Nokia CorporationNokia Proprietary and Confidential

23 (24)

 AXC delays

Page 24: AXC Product Description

7/28/2019 AXC Product Description