audiology in orl
DESCRIPTION
DR. BANDAR MOHAMMED AL-QAHTANI, M.D KSMC. AUDIOLOGY IN ORL . Tympanic mem & Ossicular Amplification 22:1 in total 1.3:1 maleus to incus (lever action) 17 :1 TM surface to stapes footplate problem in transmission leads to CHL . Anatomy of hearing organ THE COCHLEA. - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/1.jpg)
AUDIOLOGY IN ORL
DR. BANDAR MOHAMMED AL-QAHTANI, M.D
KSMC
![Page 2: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/2.jpg)
2
Tympanic mem & Ossicular Amplification22:1 in total 1.3:1 maleus to incus (lever action) 17 :1 TM surface to stapes footplateproblem in transmission leads to CHL
![Page 3: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/3.jpg)
3
Anatomy of hearing organTHE COCHLEA
![Page 4: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/4.jpg)
4
Traveling wave & Tonotopic organization
Traveling wave & Tonotopic organization
High frequency at base and low frequency at apexproblem inside the cochlea transmission leads to SNHL
![Page 5: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/5.jpg)
5
Auditory Assessment Clinical vs audiometric tests Clinical : - finger friction - watch test - speech test - tuning fork test
![Page 6: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/6.jpg)
6
Audiometric tests : subjective vs objective tests - pure tone audiometry - speech audiometry - impedance audiometry a-tympanometry b-acoustic reflex
![Page 7: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/7.jpg)
7
Anatomy
![Page 8: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/8.jpg)
8
Audiometric Assessment
Pure Tone Audiometry Speech Audiometry Acoustic Immittance (impedance test
) Auditory Brainstem Responses Electrocochleography Otoacoustic Emissions
![Page 9: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/9.jpg)
9
Pure Tone Audiometry Most common ,subjective test Air conduction testing
Frequencies 125,250,500,1000,2000,4000,8000 HZ
Bone conduction testing 250,500,1000,2000,4000 HZ
![Page 10: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/10.jpg)
10
Pure tone audiometry
![Page 11: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/11.jpg)
11
USES As baseline test (pre op and post op) To differentiate the conductive vs sensorineural
pathway The degree of handicap or heaing loss and which
frequencies
![Page 12: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/12.jpg)
12
Crossover Audiometric results are only valid when the
results are actually of the test ear. Interaural attenuation reflects crossover. Air conduction from 40-80dB Bone conduction even at 0dB
![Page 13: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/13.jpg)
13
Masking
The audiometric technique used to eliminate responses by the non-test ear.
An appropriate noise is presented to the non-test ear while the test ear is being tested.
Masking level must exceed the non-test ear threshold, but not create crossover.
![Page 14: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/14.jpg)
14
Speech Audiometry Determines how well a person hears and
understands speech,subjective test. Spondee words SRT 50% of spondees SRT should be in close correlation with
PTA +- 10 db of PTA. Discrimination score (DS) (90-100% in
normal or conductive DS is 60-70 in sensory hearing loss
![Page 15: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/15.jpg)
15
DS -(normal ,CHL, COCHLEAR &RETROCOCH ROLLOVER )
![Page 16: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/16.jpg)
16
USES-malingerer patients-for fitting Hearing Aids-for cochlear implant patients-to differentiate cochlear than retro-cochlear lesion
![Page 17: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/17.jpg)
17
Acoustic Immittance Impedance: resistance to acoustic
flow,objective test Admittance: ease of acoustic flow Tested by:
Tympanometry Acoustic Stapedial Reflex
![Page 18: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/18.jpg)
18
Tympanometryby Jerger
![Page 19: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/19.jpg)
19
A normal between 100-(-100) As stiff type otosclerosis or stiff TM. Ad flaccid type ossicular discontinuity B flat –fluid in ME or thick TM C more in negative –retracted TM
![Page 20: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/20.jpg)
20
Acoustic Stapedial Reflexto elicit a stapedial muscle
contraction, objective test. 3 primary acoustic reflex
characteristics Presence or absence of the reflex Reflex threshold Reflex Decay It tests VIII,brain stem ,VII Good for screening in infants and
malingerer
![Page 21: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/21.jpg)
21
Acoustic Reflex Decay Measures the ability of the stapedius
muscle to maintain sustained contraction.
Lower frequency tone/noise for 10 seconds
![Page 22: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/22.jpg)
22
Facial Paralysis Absent or abnormal stapedial reflex
when the recording probe is ipsilateral to the side of the lesion.
Can also be helpful in locating lesions proximal or distal to the stapedial muscle.
![Page 23: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/23.jpg)
23
Eighth nerve lesions Absent reflexes when stimuli is
presented to the affected ear. Reflexes in eighth nerve lesions are
not dependent on the degree of hearing loss.
Rapid reflex decay
![Page 24: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/24.jpg)
24
Auditory Brainstem Responses
Impulses that are generated by the auditory neural pathway that can be recorded on the scalp.
objective test Not affected by sleep, sedation, or
attention.
![Page 25: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/25.jpg)
25
Bone Conduction ABR As reliable and repeatable as air
conduction ABR. Particularly useful in structural
abnormalities Canal Atresia or stenosis
![Page 26: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/26.jpg)
26
ABR Primary goal is a clear and reliable
Wave I Wave I : distal 8th nerve Wave II : proximal 8th nerve Wave III : cochlear nuclei Wave IV : SOC Wave V : Lateral Lemniscus
![Page 27: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/27.jpg)
27
ABR
![Page 28: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/28.jpg)
28
Otoacoustic EmissionsLow energy sounds produced by the
cochlear outer hair cells,objective test.
Cochlear amplification. Spontaneous emissions
Not present in greater than 25dB hearing loss.
Evoked Emissions Transient evoked Distorted Product
![Page 29: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/29.jpg)
29
OAE and middle ear pathology
Transmission properties of the middle ear directly influence the OAE characteristics. Otitis media Newborns Tympanic membrane perforations
![Page 30: AUDIOLOGY IN ORL](https://reader036.vdocuments.mx/reader036/viewer/2022062302/56816624550346895dd97e8a/html5/thumbnails/30.jpg)
30
ANY QUESIONS