atomic & nano imaging and microscopes · • 6 - 384 microplate reading capability • shaking...
TRANSCRIPT
Spectrometers
1. Renishaw InVia Raman Spectrometer2. Bruker Avance 300 NMR3. Chiralscan CD Spectrometer4. Prodigy High Dispersion ICP5. PerkinElmer LS55 Fluorescence Spectrometer6. UV-Vis Spectrometer7. PerkinElmer Spectrum One FTIR8. Spectra Max M5 Microplate Reader9. Synergy HT Microplate Reader10. Nano Drop 2000c11. Nano Drop ND-100012. Polarimeter
Location: N1.2-B5-10Contact email: [email protected]
Renishaw InVia Reflex Raman Spectrometer
Key features of Renishaw InVia Reflex Raman• With capabilities for 514 nm, 633 nm and 785 nm
excitation sources• Class 3B enclosure & DM 2500 Leica Microscope with 5X,
20X, 50X and long working distance 50X objectives and Blue Fox Video Camera
• High precision motorized XYZ mapping stage, with travel range X > 100 mm, Y > 70 mm, minimum step size and repeatability <= 100 nm
• Auto-kinematically mounted, Rayleigh line rejection filters, cut-off <= 100 cm-1 from the laser line
• Visible and NIR polarizers • With gratings 1800 lines mm-1 and 1200 lines mm-1 .• Spectra repeatability <= 0.2 cm-1 and stability at 0.05 cm-1
when grating is static• Spatial resolution of 1-2 um depending on laser wavelength• Unique extended scanning facility• High resolution < 2 cm-1 and wide spectral range (100 cm-1 to
4000 cm-1 )
Location: N1.2-B5-03Contact email: [email protected]/[email protected]
Bruker Avance II 300MHz NMR Spectrometer
Key features of AV 300MHz NMR • Automated gradient shimming with Topspin version 1.3 software• Automatic tuning and matching for probe • Variable temperature control for probe • Equipped with 2 channels• For liquid samples• For both 1D and 2D experiments• For experiments 1H, 13C, 15N, 19F, 31P and others
AV 300 NMR
Location: N1.2-B3-06Contact email: [email protected]
Chirascan CD Spectrometer
Key features of Chiralscan CD
• Dual polarising prism monochromator with digital drive and calibration
• Pure linearly polarized monochromatic light and high spectral bandwidths in the far-UV
• Wavelength range 165 – 900 nm• Temperature controlled by water circulator • High performance digital signal processing of raw data• High speed real-time control• Expandable modular electronics• Rapid and economical nitrogen purge design to allow
far-UV light transmission and prevent the formation of ozone• Light source is a 150W Xenon arc with both a rear
reflector and optimized ellipsoidal focusing mirror for maximum efficiency and light capture
• Maximize light throughput without compromising focusing performance
Prodigy High Dispersion ICP
Prodigy High Dispersion ICP
Key features of Prodigy High Dispersion ICP
• High quality spectral information with Prodgy’s Large
Format Programmable Array detector(L-PAD)
• Full wavelength coverage
• High precision elemental ratio measurement with
simultaneous data acquisition
• Measure trace elements and major sample
constituents (Radial, Axial or dual view) at the same
time
Location: N1.2-01-03Contact email: [email protected]
Location: N1.2-B3-06Contact email: [email protected]
PerkinElmer LS55 Fluorescence SpectrometerShimadzu UV 2450 Spectrometer
Key features of Shimadzu UV 2450 Spectrometer• Source: halogen lamp and deuterium lamp, light
source auto position adjustment built in• Wavelength 200-900 nm• With TCC-240A thermoelectrically temperature
controlled cell holder• Temperature control range: 7 to 60 °C
Key features of PerkinElmer LS55 Fluorescence Spectrometer• Source: Xenon discharge lamp• Red-sensitive R928 photomultiplier fitted sample detector for
operation up to 900 nm• Monochromator excitation range 200-800 nm; emission range 200-900 nm• Wavelength accuracy ±1.0 nm; reproducibility ±0.5 nm• Spectra bandpass: excitation slits 2.5-15 nm and emission slits 2.5 -20 nm; 0.1 nm
increments.• With solid and liquid sample holders• With thermostat control liquid cell holder
Location: N1.2-B3-06/N1.3-B4-21Contact email: [email protected]/[email protected]
Location: N1.2-B3-06Contact email: [email protected]
PerkinElmer Spectrum One FTIR
SpectraMax M5 Multi-Mode Microplate Reader
Key features of Multi-Mode Microplate Readers (SpectraMax M5)
• Measure absorbance (UV-Vis), fluorescence intensity (FI), fluorescence polarization (FP), time-resolved fluorescence (TRF) and luminescence (Lum)
• Cuvette port and 6 - 384 microplate reading capability• Wavelengths : 200 - 1000 nm• Dual monochromators for assay flexibility • Comprehensive data analysis software
Location: N1.3-B3-22Contact email: [email protected]/[email protected]
Key features of Synergy HT Microplate Reader
• For Fluorescence, Time Resolved Fluorescence, UV-Visible Absorbance Luminescence applications
• 6 - 384 microplate reading capability• Shaking feature: Linear, orbital • Temperature range: Incubation up to 50 °C • Fluorescence Wavelength Range: 300 - 700 nm
Biotek Synergy HT Microplate Reader
Spectra Max M5 Microplate Reader
Synergy HT Microplate Reader
Thermo Scientific NanoDrop 2000c
Key Features of NanoDrop 2000c: • Sample Volume: 0.5 to 2.0 µL • Concentration: 2ng/µl-15,000ng/µl (dsDNA) ng/µ• Wavelength Range: 190-840 nm • Wavelength Accuracy: ±1 nm • Spectral Resolution: < 1.8nm• Accuracy: 0.002• Measurement Time: < 3 seconds
NanoDrop 2000c
Location: N1.3-B4-21c/N1.3-B3-22Contact email: [email protected]/[email protected]
Key features of spectrophotometer NanoDrop® ND-1000 • Measure highly concentrated samples without dilution• Measure range: 220-750nm • Sample Size: 1-2ul • Measurement Time: 10 Seconds
NanoDrop ND-1000Spectrophotometer NanoDrop ND-1000