atex zones infographic

1
NEC IEC/ATEX Which type of hazardous location classification system does your company use? First determine the Class: What type of hazadous substance is present? Now determine the division: How often is the hazardous substance present? Gases / Vapors (Class I) Dust (Class II) Fibers or flyings (Class III) How often is the hazardous substance present Gases / Vapors (zones 0, 1, or 2) Dust (zones 20, 21, or 22) What type of hazardous substance is present? On a normal basis - continously or for long periods Only in abnormal circumstances - when the substance escapes from a closed container Division 1 Division 2 Gases / Vapors zone 0 Dust: zone 20 Gases / Vapors zone 1 Dust: zone 21 Gases / Vapors zone 2 Dust: zone 22 Continuously or for long periods in normal operations Not likely in normal operations Likely that it will be present some of the time in normal operations Area in which an explosive atmosphere with a mixture of air and flammable substances in the form of gas, vapour or fog is present, either constantly or in the long term. ZONE Flammable Explosive Chemical Manufacturing Oil & Gas Pharmaceutical Area in which it must be assumed that an explosive atmosphere with a mixture of air and flammable substances in the form of gas, vapour or fog arises during normal operation. ZONE Area in which it must be not assumed that an explosive atmosphere with a mixture of air and flammable substances in the form of gas, vapour or fog arises during normal operation and if so, then only rarely and for a short time. Gas Dust ZONE Area in which is must be assumed that an explosive atmosphere in the form of a cloud of flammable dust in air sometimes occurs during normal operation. ZONE ZONE Area in which there is an explosive atmosphere in the form of a cloud of flammable dust in the air, constantly, in the long term or frequently. ZONE Area in which is must not be assumed that an explosive atmosphere in the form of a cloud of flammable dust in air sometimes occurs during normal operation, and if this happens, then only for a short time. ZONE What industries use ATEX zones? Email - [email protected] Website - www.visionid.ie Telephone - 1850 923 633 Flammable Explosive Flammable Explosive Flammable Explosive Flammable Explosive Flammable Explosive

Upload: visionid

Post on 17-Jul-2015

55 views

Category:

Technology


1 download

TRANSCRIPT

Page 1: Atex zones infographic

NEC IEC/ATEX

Which type of hazardous location classi�cation system

does your company use?

First determine the Class: What type of hazadous substance is present?

Now determine the division: How often is the

hazardous substance present?

Gases/Vapors(Class I)

Dust(Class II)

Fibers or �yings(Class III)

How often is the hazardous substance

present

Gases/Vapors(zones 0, 1, or 2)

Dust (zones20, 21, or 22)

What type of hazardous substance is present?

On a normal basis - continously or for

long periods

Only in abnormal circumstances -

when the substance escapes from a closed container

Division 1 Division 2 Gases/Vaporszone 0

Dust: zone 20

Gases/Vaporszone 1

Dust: zone 21

Gases/Vaporszone 2

Dust: zone 22

Continuously or for long periods

in normal operations

Not likely in normal

operations

Likely that it will be present

some of the time in normal

operations

Area in which an explosive atmosphere with a mixture of air and �ammable substances in the form of gas, vapour or fog is present, either constantly or in the long term.

ZONE

Flammable Explosive

ChemicalManufacturing Oil & Gas Pharmaceutical

Area in which it must be assumed that an explosive atmosphere with a mixture of air and �ammable substances in the form of gas, vapour or fog arises during normal operation.

ZONE

Area in which it must be not assumed that an explosive atmosphere with a mixture of air and �ammable substances in the form of gas, vapour or fog arises during normal operation and if so, then only rarely and for a short time.

Gas

Dust

ZONE

Area in which is must be assumed that an explosive atmosphere in the form of a cloud of �ammable dust in air sometimes occurs during normal operation.

ZONEZONE

Area in which there is an explosive atmosphere in the form of a cloud of �ammable dust in the air, constantly, in the long term or frequently.

ZONE

Area in which is must not be assumed that an explosive atmosphere in the form of a cloud of �ammable dust in air sometimes occurs during normal operation, and if this happens, then only for a short time.

ZONE

What industries use ATEX zones?

Email - [email protected] - www.visionid.ieTelephone - 1850 923 633

Flammable Explosive

Flammable Explosive

Flammable Explosive

Flammable Explosive

Flammable Explosive