assembly instructions lx wall mount system
TRANSCRIPT
1 of 16888-45-390-G-00 rev.B • 11/17
LX Wall Mount System
5°
80°180°360°
180°
13"(330 mm)
0 - 5 lbs(0 - 2.3 kg)
180°360°
180°
13" (330 mm)
90°
5°
3°3°
User's Guide - EnglishGuía del usuario - EspañolManuel de l’utilisateur - FrançaisGebruikersgids - DeutschBenutzerhandbuch - NederlandsGuida per l’utente - ItalianoAnvändarhandbok - svenskaユーザーガイド : 日本語用户指南 : 汉语
7 - 25 lbs*(2.3 - 11.3 kg)
< 4.5” (114 mm)
8.5” (216 mm)
IncludesConstant Force™
Technology
ENGLISHASSEMBLY INSTRUCTIONS
For the latest User Installation Guide please visit: www.ergotron.com
* The lower most range of motion for vertical lift is
decreased up to 4.5” (114 mm) when arm is adjusted to
hold over 20lbs (9 kgs).
2 of 16888-45-390-G-00 rev.B • 11/17
A B C D
1
2
3
4
5
6
7
8
9
M4 x 10mm
4x
M4 x 10mm
4x4mm
1x1x
2x
2x
2x
1x
1x
8x10-24 x 1/2"
21
1x
Ø 3/16" (5 mm)Wood
MaderaBois
Solide HolzbalkenträgerMassief Houten Pilaren
Due montanti in legno massiccio木
木质나무
1x
3x
1x
1x
1x2x
2x1x
2x
1x
2x
2x
2x
Ø 1/2” (12.7 mm)Hollow WallParedMurWandMuurParete壁墙壁
1/4-20 x 1/2"
9x
14x
2x
Studs ≥ 25 gauge steelPernos de acero de calibre ≥ 25Goujons ≥ calibre 25 en acierBolzen ≥ Blechlehre Nr. 25Verbindingsbouten ≥ 25 gauge staalPrigionieri in acciaio spessore ≥ gauge 25 (0,556 mm)Reglar ≥ 25-gauge stål25ゲージのスチールよりも強力なスタッド板墙筋为不小于 25 标号的钢材
1/4-20 x 2"
14x
7x
7x
M4.2 x 25mm
4x
4x
4x
1x 1x
4x
2.5mm
1/8”
M3 x 6mm
4x
4xM4 x 8mm
1x
1x
1x
2x
M4 x 14mm
2xM10 x 16mm
6mm
ENGL
ISH
Stud Finder
Components
Tools Needed
3 of 16888-45-390-G-00 rev.B • 11/17
1
21”(533 mm)
5’0” - 6’4”(152-193cm)
5’0” - 6’1”(152-185cm)
5’0” - 6’1”(152-185cm)
22.5”(571mm)
31.5”(800mm)
21”(533 mm)
21”(533 mm)
31.5”(800mm)
47”(1194mm)
< 21.5”(546mm)
21”(533 mm)
5’0” - 6’4”(152-193cm)
26.4(670mm)
35”(889mm)
< 25.4”(645mm)
< 30.5”(775mm)
35.4”(899mm)
50.5”(1283mm)
< 34.4”(874mm)
6”(152 mm)
14.7”(373mm)
2.5”(63mm)17.7”
(449mm) 20.7”(526mm)
0.6”(14mm)
2”(50mm)
8.2”(207mm)
ENGLISH
This mounting height is a recommendation for an ergonomic workstation that accommodates user heights of 5'0"-6'1" (152-185cm) when set up for standing and user heights of 5’0”-6’4” (152-193cm) when set up for sitting.
If user heights are diff erent than this, you should change mounting height to accommodate user heights. (Change mount-ing height one inch for every one inch diff erence in user heights).
Determine mounting location:
Mounting height assumes there is a 6” (152 mm) dis-tance between the center of your monitor mounting holes and the top of the screen. If your distance is smaller, you should increase mounting height accord-ingly, if your distance is larger, you should decrease your mounting height ac-cordingly.
Top view showing range of motion when pulled out from the wall.
Front view with arm pushed back against the wall.
Mounting Height for Ergonomic Workstation
4 of 16888-45-390-G-00 rev.B • 11/17
Studs ≥ 25 gauge steel
Pernos de acero de calibre ≥ 25
Goujons ≥ calibre 25 en acier
Bolzen ≥ Blechlehre Nr. 25
Verbindingsbouten ≥ 25 gauge staal
Prigionieri in acciaio spessore ≥ gauge 25 (0,556 mm)
Reglar ≥ 25-gauge stål
25ゲージのスチールよりも強力なスタッド板墙筋为不小于 25 标号的钢材
2
Requires minimum material thickness of 5/8” (16 mm).Requiere un grosor mínimo de 16 mm.Epaisseur minimum de 16 mm.Requer uma espessura mínima de 5/8” (16 mm).Mit einer Materialdicke von mindestens 16 mm.Vereist een minimale materiaaldikte van 1.6 cm.Richiede uno spessore del materiale non inferiore a 16 mm.厚さが最低 5/8” (16 mm) の資材が必要。需要最低材料厚度为 5/8”(16 mm).
5
≥ 5/8”
Sheetrock
Sheetrock
Plaque de plâtre
Rigipsplatte
Sheetrock
Cartongesso
Gipsskiva
シートロック石膏板
6
Wood
Madera
Bois
Solide Holzbalkenträger
Massief Houten Pilaren
Due montanti in legno massiccio
木木质나무
Hollow Wall
Pared
Mur
Wand
Muur
Parete
壁墙壁
ENGL
ISH
CAUTION: Make sure the wall mount bracket is level,
fl ush and snug to the wall surface. DO NOT OVERTIGHT-
EN THE BOLTS.
WARNING: Ensure that the wall structure is capable
of supporting four times the total weight of mounted
equipment. Mounting to wall surfaces that do not meet
this criteria may result in an unstable, unsafe condition
which could lead to personal injury and/or property
damage. Consult a construction professional if you
have any doubt about what this means in regard to
your particular application.
5 of 16888-45-390-G-00 rev.B • 11/17
7Ø 3/16" (5 mm)
x 5
a
e f
c b
d
3
Wood
Madera
Bois
Solide Holzbalkenträger
Massief Houten Pilaren
Due montanti in legno massiccio
木木质나무
Studs ≥ 25 gauge steel
Pernos de acero de calibre ≥ 25
Goujons ≥ calibre 25 en acier
Bolzen ≥ Blechlehre Nr. 25
Verbindingsbouten ≥ 25 gauge staal
Prigionieri in acciaio spessore ≥ gauge 25 (0,556 mm)
Reglar ≥ 25-gauge stål
25ゲージのスチールよりも強力なスタッド板墙筋为不小于 25 标号的钢材
Studs ≥ 25 gauge steel
Pernos de acero de calibre ≥ 25
Goujons ≥ calibre 25 en acier
Bolzen ≥ Blechlehre Nr. 25
Verbindingsbouten ≥ 25 gauge staal
Prigionieri in acciaio spessore ≥ gauge 25 (0,556 mm)
Reglar ≥ 25-gauge stål
25ゲージのスチールよりも強力なスタッド板墙筋为不小于 25 标号的钢材
7x
7x
ENGLISH
Stud Finder
Wood Stud Mounting
6 of 16888-45-390-G-00 rev.B • 11/17
1
2
3
4
b c
d e
Ø 1/2"(12.7 mm)
a
14x
1/4-20 x 2"
Requires minimum material thickness of 5/8” (16 mm).Requiere un grosor mínimo de 16 mm.Epaisseur minimum de 16 mm.Requer uma espessura mínima de 5/8” (16 mm).Mit einer Materialdicke von mindestens 16 mm.Vereist een minimale materiaaldikte van 1.6 cm.Richiede uno spessore del materiale non inferiore a 16 mm.厚さが最低 5/8” (16 mm) の資材が必要。需要最低材料厚度为 5/8”(16 mm).
f
73
≥ 5/8”
Sheetrock
Sheetrock
Plaque de plâtre
Rigipsplatte
Sheetrock
Cartongesso
Gipsskiva
シートロック石膏板
Hollow Wall
Pared
Mur
Wand
Muur
Parete
壁墙壁
14x
ENGL
ISH
7 of 16888-45-390-G-00 rev.B • 11/17
a
4x10-24 x 1/2"
4x10-24 x 1/2"
3
8x10-24 x 1/2"
1/4-20 x 1/2"
8xb c
d
ENGLISHNOTE: Fasteners may unwind due to vibration caused by movement of mounting solution over
time. Inspect mounting solution for loose fasteners on a routine basis. If desired, apply a light duty
thread locking adhesive to fasteners before installation to prevent back-out.
11 of 16888-45-390-G-00 rev.B • 11/17
9
ENGLISH
NOTE: Leave enough slack in cable to allow full range of motion.
Caution: To avoid the potential to pinch cables it is important to follow the cable routing
instructions in this manual. Failure to follow these instructions may result in equipment
damage or personal injury.
12 of 16888-45-390-G-00 rev.B • 11/17
10
11
cb d
b
e fM4.2 x 25mm M4.2 x 25mm
a
a b d e
c
Flush with drywal1 2 3
Ø 7/32" (5.6 mm)
ENGL
ISH
13 of 16888-45-390-G-00 rev.B • 11/17
12
a
WARNING WARNING
�
�4mm
ENGLISH
Adjustment StepImportant! You will need to adjust this product after installation is complete. Make sure all your equipment is properly installed on the product before attempting adjustments. This product should move smoothly and easily through the full range of motion and stay where you set it. If movements are too easy or diffi cult or if product does not stay in desired positions, follow the adjustment instructions to create smooth and easy movements. Depending on your product and the adjustment, it may take many turns to notice a difference. Any time equipment is added or removed from this product, resulting in a change in the weight of the mounted load, you should repeat these adjustment steps to ensure safe and optimum operation.
WARNING! Stored Energy Hazard: The arm mechanism is under tension and will move up rapidly, on its own, as
soon as attached equipment is removed. For this reason, DO NOT remove equipment unless the arm has been
moved to the highest position! Failure to follow this instruction may result in serious personal injury and/or
equipment damage!
Lift – Up and down
CAUTION: DO NOT overtighten fasteners.
Overtightening may cause damage to your
equipment.
Increase Lift StrengthIf the mounted weight is too heavy or this product does not stay up when raised, then you'll need to increase Lift Strength:
Decrease Lift StrengthIf the mounted weight is too light or this product does not stay down when lowered, then you'll need to decrease Lift Strength:
14 of 16888-45-390-G-00 rev.B • 11/17
4mmb
0°
M3 x 6mm
c
d
2.5mm
�
�
ENGL
ISH
Rotate – Portrait/Landscape
Arm Swing – Side-to-side
Tilt – Forward and Backward
Increase FrictionIf this product moves too easily, then you'll need to increase friction:
Decrease FrictionIf this product is too diffi cult to move, then you'll need to decrease friction:
Increase FrictionIf this product moves too easily, then you'll need to increase friction:
Decrease FrictionIf this product is too diffi cult to move, then you'll need to decrease friction:
CAUTION: DO NOT remove screw. Removing screw may
cause damage to equipment.
15 of 16888-45-390-G-00 rev.B • 11/17
3°3°
M4 x 14mm
2x
ENGLISH
How to remove this tilting feature:
Save these screws incase you want to add this feature later.
16 of 16888-45-390-G-00 rev.B • 11/17
© 2017 Ergotron, Inc. All rights reserved.
1xa c b d
1/8"
2x
M10 x 16mm
6mm
ENGL
ISH
Learn more about ergonomic computer use at:
www.computingcomfort.org
Set Your Workstation to Work For YOU!
Height Position top of screen slightly below eye level. Position keyboard at about elbow height with wrists fl at. Distance Position screen an arm's length from face—at least 20” (508mm). Position keyboard close enough to create a 90˚ angle in elbow. Angle Tilt screen to eliminate glare. Tilt the keyboard back 10° so that your wrists remain fl at.
To Reduce FatigueBreathe - Breathe deeply through your nose.Blink - Blink often to avoid dry eyes.Break • 2 to 3 minutes every 20 minutes• 15 to 20 minutes every 2 hours.
For local customer care phone numbers visit: http://contact.ergotron.comFor Service visit: www.ergotron.comFor Warranty visit: www.ergotron.com/warranty
How to attach optional CPU holder accessory (ordered separately)