asbestos surveys cq pty ltd, mobile 0418 791079 19 steel...
TRANSCRIPT
Eric Batty, Phone 07 4973 3040Director, Fax 07 4973 9750
Asbestos Surveys CQ Pty Ltd, Mobile 0418 791079
19 Steel Street, Tannum Sands Qld. 4680 Email [email protected]
1 of 19 29 Bloomfield Street
ASBESTOS SITE INSPECTION REPORT
CLIENT DETAILS
CLIENTS NAME Gladstone Regional Council
ATTENTION Mrs Heather Riches
CLIENTS ADDRESS PO Box 29
CITY Gladstone Qld 4680
DATE OF
ASSESSMENT
17th April 2013
BUILDING ADDRESS 29 Blomfield Street
Town Miriam Vale Qld 4677
2 of 19 29 Bloomfield Street
ASBESTOS SITE REPORT
1ST AREA
FLOOR LEVEL Subfloor
AREA 1 Subfloor on the north western side of the strong room
LOCATION 1 Fibro sheeting in the subfloor on the north western side of the strong room betweenthe joists
1st Area FRIABLE or
BONDED
Bonded
TYPE AC sheeting
SUSPECTED Yes
CONDITION AREA 1 Good, undamaged
LEVEL of RISK AREA 1 Low
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 1
ACM presents little risk but must be monitored regularly (minimum annualinspections) for signs of deterioration and/or damage.
QUANTITY 0.5 m2
SAMPLE NO, No Sample was taken, this area is presumed to contain Asbestos and should betreated as such.
SAMPLE RESULTS Chrysotile
2ND AREA
FLOOR LEVEL Ground floor
AREA 2 Rear right side electrical switchboard
LOCATION 2 Rear right side electrical switchboard backing
2nd Area FRIABLE or
BONDED
Bonded
TYPE Switchboard Backing
SUSPECTED Yes
PHOTO'S
CONDITION AREA 2 Good, undamaged
LEVEL of RISK AREA 2 Low
LIKELIHOOD Possible
PRIORITY OUTCOME
AREA 2
Risk is to be planned in for removal if practical in the next budget period. If there isrisk to health it should be isolated and/or managed as per the AMP. Further monitoring of the ACM may be required depending on the environment it iswithin.
QUANTITY 0.4 m2
SAMPLE NO, 29 Blomfield-02
SAMPLE RESULTS Chrysotile
3 of 19 29 Bloomfield Street
3RD AREA
FLOOR LEVEL Ground floor
AREA 3 Rear right corner ORG formwork
LOCATION 3 Rear right corner ORG fibro formwork
3rd Area FRIABLE or
BONDED
Bonded
TYPE AC fibro sheet
SUSPECTED Yes
PHOTO'S
CONDITION AREA 3 Poor, major damage evident
LEVEL of RISK AREA 3 Medium
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 3
ACM presents little risk but must be monitored regularly (minimum annualinspections) for signs of deterioration and/or damage.
QUANTITY 0.2 m2
SAMPLE NO, 29 Blomfield-03
SAMPLE RESULTS Chrysotile
4 of 19 29 Bloomfield Street
4TH AREA
FLOOR LEVEL Ground floor
AREA 4 Rear staff toilet walls
LOCATION 4 Rear staff toilet wall sheeting
4th Area FRIABLE or
BONDED
Friable
TYPE Low Density Board
SUSPECTED Yes
PHOTO'S
CONDITION AREA 4 Fair, minor to moderate damage evident.
LEVEL of RISK AREA 4 High
LIKELIHOOD Almost Certain
PRIORITY OUTCOME
AREA 4
Removal / further assessment of this risk is to be planned immediately, area is to bemade a "no go" zone and sign posted accordingly. No untrained personnel allowedin the immediate area.An appropriately trained person, refer to Asbestos Management Plan (AMP), mustbe engaged to manage this assessment and if required, remove the ACM safely.Once removed the Asbestos Register must be updated to reflect the changes.
QUANTITY 3.2 m2
SAMPLE NO, 29 Blomfield-04
SAMPLE RESULTS Chrysotile - Amosite
5 of 19 29 Bloomfield Street
5TH AREA
FLOOR LEVEL Ground floor
AREA 5 Foyer/Entry floor covering
LOCATION 5 Foyer/Entry grey vinyl floor covering
5th Area FRIABLE or
BONDED
Bonded
TYPE Vinyl Flooring
SUSPECTED Yes
PHOTO'S
CONDITION AREA 5 Good, undamaged
LEVEL of RISK AREA 5 N/A
LIKELIHOOD Almost Certain
PRIORITY OUTCOME
AREA 5
N/A
QUANTITY 8 m2
SAMPLE NO, 29 Blomfield-05
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
6 of 19 29 Bloomfield Street
6TH AREA
FLOOR LEVEL Ground floor
AREA 6 Main service area and walk way under the green carpet
LOCATION 6 Main service area and walk way vinyl tiles under the green carpet
6th Area FRIABLE or
BONDED
Bonded
TYPE Vinyl Tiles
SUSPECTED Yes
PHOTO'S
CONDITION AREA 6 Good, undamaged
LEVEL of RISK AREA 6 N/A
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 6
N/A
QUANTITY 53 m2
SAMPLE NO, 29 Blomfield-06
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
7 of 19 29 Bloomfield Street
7TH AREA
FLOOR LEVEL Ground floor
AREA 7 Store room/Smoko room and in front of the strong room floor
LOCATION 7 Store room/Smoko room and in front of the strong room off white vinyl tiles
7th Area FRIABLE or
BONDED
Bonded
TYPE Vinyl Tiles
SUSPECTED Yes
PHOTO'S
CONDITION AREA 7 Poor, major damage evident
LEVEL of RISK AREA 7 N/A
LIKELIHOOD Almost Certain
PRIORITY OUTCOME
AREA 7
Risk must be controlled in the short term by means of encapsulation or other (referto Asbestos Management Plan for other methods of control).Planning should commence to remove the risk as soon as practicable. A competentperson, must, based on type and quantity, be engaged (refer to AMP for competentperson).The risk must be communicated to the people in the area and if not managed byencapsulation or other means in the short term the area be made a "no go" zone.
QUANTITY m2 9
SAMPLE NO, 29 Blomfield-07
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
8 of 19 29 Bloomfield Street
8TH AREA
FLOOR LEVEL Ground floor
AREA 8 Main stair hallway under the carpet
LOCATION 8 Main stair hallway beige vinyl under the carpet
8th Area FRIABLE or
BONDED
Bonded
TYPE Vinyl Flooring
SUSPECTED Yes
PHOTO'S
CONDITION AREA 8 Good, undamaged
LEVEL of RISK AREA 8 N/A
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 8
N/A
QUANTITY 14 m2
SAMPLE NO, 29 Blomfield-08
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
9 of 19 29 Bloomfield Street
9TH AREA
FLOOR LEVEL Ground floor
AREA 9 Formal dining room under the carpet
LOCATION 9 Formal dining room paper underlay under the carpet
9th Area FRIABLE or
BONDED
Friable
TYPE Paper underlay
SUSPECTED Yes
PHOTO'S
CONDITION AREA 9 Fair, minor to moderate damage evident.
LEVEL of RISK AREA 9 N/A
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 9
N/A
QUANTITY 20 m2
SAMPLE NO, 29 Blomfield-09
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
10 of 19 29 Bloomfield Street
10TH AREA
FLOOR LEVEL Ground floor
AREA 10 Formal dining room ceiling
LOCATION 10 Formal dining room ceiling sheeting
10th Area FRIABLE or
BONDED
Bonded
TYPE Fibre cement sheeting
SUSPECTED Yes
PHOTO'S
CONDITION AREA 10 Good, undamaged
LEVEL of RISK AREA
10
Low
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 10
ACM presents little risk but must be monitored regularly (minimum annualinspections) for signs of deterioration and/or damage.
QUANTITY 20 m2
SAMPLE NO, 29 Blomfield-10
SAMPLE RESULTS Chrysotile
Some areas are unable to be viewed, (behind wall sheeting, inside wall cavities) if this is the case and materials aresuspected to be inside the areas it is to be assumed that the materials do contain ASBESTOS.
11 of 19 29 Bloomfield Street
ASBESTOS SITE REPORT #2
11TH AREA
FLOOR LEVEL Ground floor
AREA 11 Kitchen floor
LOCATION 11 Kitchen brown and beige floor vinyl
11th Area FRIABLE or
BONDED
Bonded
TYPE Vinyl Flooring
SUSPECTED Yes
PHOTO'S
CONDITION AREA 11 Good, undamaged
LEVEL of RISK AREA
11
N/A
LIKELIHOOD Almost Certain
PRIORITY OUTCOME
AREA 11
N/A
QUANTITY 17 m2
SAMPLE NO, 29 Blomfield-11
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
12 of 19 29 Bloomfield Street
12TH AREA
FLOOR LEVEL Ground floor
AREA 12 Kitchen floor
LOCATION 12 Kitchen floor vinyl tiles under the vinyl flooring
12th Area FRIABLE or
BONDED
Bonded
TYPE Vinyl Tiles
SUSPECTED Yes
PHOTO'S
CONDITION AREA 12 Fair, minor to moderate damage evident.
LEVEL of RISK AREA
12
N/A
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 12
N/A
QUANTITY 17 m2
SAMPLE NO, 29 Blomfield-12
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
13 of 19 29 Bloomfield Street
13TH AREA
FLOOR LEVEL 2nd
AREA 13 Main Bedroom floor
LOCATION 13 Main Bedroom floor paper underlay under the carpet
TYPE Paper underlay
SUSPECTED Yes
PHOTO'S
CONDITION AREA 13 Good, undamaged
LEVEL of RISK AREA
13
N/A
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 13
N/A
QUANTITY 15 m2
SAMPLE NO, 29 Blomfield-18
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
14 of 19 29 Bloomfield Street
14TH AREA
FLOOR LEVEL 2nd
AREA 14 Front verandah floor
LOCATION 14 Front verandah floor water proofing membrane
14th Area FRIABLE or
BONDED
Bonded
TYPE Malthoid
SUSPECTED Yes
PHOTO'S
CONDITION AREA 14 Fair, minor to moderate damage evident.
LEVEL of RISK AREA
14
N/A
LIKELIHOOD Almost Certain
PRIORITY OUTCOME
AREA 14
N/A
QUANTITY 12 m2
SAMPLE NO, 29 Blomfield-14
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
15 of 19 29 Bloomfield Street
15TH AREA
FLOOR LEVEL 2nd
AREA 15 Front verandah gable end
LOCATION 15 Front verandah gable end sheeting
15th Area FRIABLE or
BONDED
Bonded
TYPE Wall sheeting
SUSPECTED Yes
PHOTO'S
CONDITION AREA 15 Good, undamaged
LEVEL of RISK AREA
15
Low
LIKELIHOOD Unlikely
PRIORITY OUTCOME
AREA 15
ACM presents little risk but must be monitored regularly (minimum annualinspections) for signs of deterioration and/or damage.
QUANTITY 1 m2
SAMPLE NO, 29 Blomfield-15
SAMPLE RESULTS Chrysotile
16 of 19 29 Bloomfield Street
16TH AREA
FLOOR LEVEL 2nd
AREA 16 Bedroom 4 floor
LOCATION 16 Bedroom 4 vinyl under the carpet
16th Area FRIABLE or
BONDED
Bonded
TYPE Vinyl Flooring
SUSPECTED Yes
PHOTO'S
CONDITION AREA 16 Poor, major damage evident
LEVEL of RISK AREA
16
N/A
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 16
N/A
QUANTITY 12 m2
SAMPLE NO, 29 Blomfield-16
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
17 of 19 29 Bloomfield Street
17TH AREA
FLOOR LEVEL 2nd
AREA 17 Second floor bedroom 4 hallway floor
LOCATION 17 Second floor bedroom 4 hallway vinyl under the carpet
17th Area FRIABLE or
BONDED
Bonded
TYPE Vinyl Flooring
SUSPECTED Yes
PHOTO'S
CONDITION AREA 17 Good, undamaged
LEVEL of RISK AREA
17
N/A
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 17
N/A
QUANTITY 4.5 m2
SAMPLE NO, 29 Blomfield-17
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
18 of 19 29 Bloomfield Street
18TH AREA
FLOOR LEVEL 2nd
AREA 18 Store room floor
LOCATION 18 Store room paper underlay under the carpet
18th Area FRIABLE or
BONDED
Friable
TYPE Paper underlay
SUSPECTED Yes
PHOTO'S
CONDITION AREA 18 Good, undamaged
LEVEL of RISK AREA
18
N/A
LIKELIHOOD Rare
PRIORITY OUTCOME
AREA 18
N/A
QUANTITY 8 m2
SAMPLE NO, 29 Blomfield-18
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
19 of 19 29 Bloomfield Street
19TH AREA
FLOOR LEVEL Ground floor and 2nd floor
AREA 19 Formal dining room, stair area, Stair case, Upstairs hallways, Lounge room, Storeroom and all bedrooms floor carpet
LOCATION 19 Formal dining room, stair area, Stair case, Upstairs hallways, Lounge room, Storeroom and all bedrooms floor carpet hessian backing
19th Area FRIABLE or
BONDED
Friable
TYPE Woven carpet backing
SUSPECTED Yes
PHOTO'S
CONDITION AREA 19 Good, undamaged
LEVEL of RISK AREA
19
N/A
LIKELIHOOD Possible
PRIORITY OUTCOME
AREA 19
N/A
QUANTITY 160 m2
SAMPLE NO, 29 Blomfield-19
SAMPLE RESULTS No Asbestos Detected - Organic Fibres
The inspection has been undertaken in a non-destructive manner, and as such, there may be areas where ACMexists which have not been detected. Examples of such areas are wall cavities, beneath floors/slabs and floorcoverings, within plant, hidden pipe work, cavity walls, encapsulated/enclosed areas and so forth.Some areas are unable to be viewed, (behind wall sheeting, inside wall cavities) if this is the case and materials aresuspected to be inside the areas it is to be assumed that the materials do contain ASBESTOS.