asbestos survey and lead paint report€¦ · lead paint report. c.e.c. has investigated accessible...
TRANSCRIPT
ASBESTOS SURVEY AND
LEAD PAINT REPORT
For the building located at:
1900 SW 4TH AVENUE PORTLAND, OREGON
Prepared for: Portland State University
CERTIFIED ENVIRONMENTAL CONSULTING, INC. 12806 NE 40TH CIRCLE
VANCOUVER, WASHINGTON 98682
Prepared by: Tom Thompson
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
EXECUTIVE SUMMARY Dear Mr. Torres, Enclosed are the results of the asbestos survey conducted by C.E.C., Inc. located at 1900 SW 4th Avenue, in Portland, Oregon. This survey was coordinated with you and conducted December 6, 2002 through January 3, 2003, by Tom Thompson, an AHERA certified inspector. Please note that the asphalt roofing material was not tested due to potential damaged caused by testing. These materials should be considered asbestos containing materials until testing can be completed. Do not drill through, sand on or otherwise disturb material. All samples were taken in a random manner as required by EPA AHERA rules and analyzed using polarized light microscopy with dispersion staining according to EPA and OR-OSHA Methodology. Asbestos was identified in the brown floor tile mastic, beige floor tile and mastic, pipe joint insulation, and the tan floor tile mastic (See sample data sheet attached). The following survey is divided into the following sections: ◊ Summary sheet - details the type and construction of the building with approximate amounts of
asbestos in the building. ◊ Sample result sheet - contains sample numbers and results, description of materials and
homogeneous areas of material. ◊ Assessment of materials - contains an assessment of asbestos materials. ◊ Response actions recommended - contains the response actions we recommend. ◊ Laboratory analysis sheet - contains the results of our laboratory analysis. ◊ Inspector’s certifications ◊ Lead paint report. C.E.C. has investigated accessible areas of this facility in locating suspect ACM. The current extent and condition of the ACM was detected through on-site observation and physical determination. NOTE: This asbestos survey report is available to Portland State University, and not to be reproduced in total or part without written consent of Portland State University . We appreciate the opportunity to have worked with you. If you have any questions or if we can be of any further service, please contact this office. Sincerely, Rene Garrett President
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
SUMMARY SHEET
Owner or Representative: Ruben Torres Address: 1900 SW 4th Avenue City: Portland State: Oregon Owner's Representative: Mr. Ruben Torres Portland State University
630 SW Mill Street Portland, Oregon 97201
Owner/Rep. Telephone Number: (503) 544-5388 Surveyed by: Tom Thompson - Accreditation Number: 1000987
CONSTRUCTION DATA: Year Built: Approx: 1978__ Size : Approx: 204,000 SQ FT Construction Type: Concrete, Steel Roof Construction: Asphalt Roofing Material-not tested Heating System: Hot Water Attic Insulation: Not Applicable_ Pipe Insulation: Fiberglass with some Asbestos Containing Materials
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
Summary Data
PRODUCT AMOUNT FRIABLE CONDITION SAMPLE # RESULTS
BROWN FLOOR TILE MASTIC
APPROX. 1,200 SQ FT NO GOOD 8, 37 5% CHRYSOTILE
BEIGE FLOOR TILE AND MASTIC
APPROX. 30,805 SQ
FT NO GOOD 10, 19, 27,
28, 57 3% TO 6%
CHRYSOTILE
PIPE JOINT INSULATION
4 VISIBLE FITTINGS
YES GOOD 25 15% AMOSITE
TAN FLOOR TILE MASTIC 650 SQ FT NO GOOD 51, 56 5% CHRYSOTILE
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
SAMPLE RESULTS
1900 SW 4TH AVENUE, PORTLAND, OREGON
SAMPLE # SAMPLE DESCRIPTION SAMPLE LOCATION HOMOGENEOUS
AREA ASBESTOS CONTENT
1 COMPUTER FLOORING
ELECTRICAL MECHANICAL
ROOM SUB BASEMENT
COMPUTER FLOORS THROUGHOUT NONE DETECTED
2 COVE BASE MASTIC
ELECTRICAL MECHANICAL
ROOM SUB BASEMENT
THROUGHOUT NONE DETECTED
3 PIPE JOINT INSULATION
BATTERY ROOM SUB BASEMENT THROUGHOUT NONE DETECTED
4 PIPE JOINT INSULATION
MEN’S RESTROOM LOWER LEVEL THROUGHOUT NONE DETECTED
5 GYPSUM WALLBOARD OUTSIDE LAYER P2 THROUGHOUT NONE DETECTED
6 GYPSUM WALLBOARD INSIDE LAYER P2 THROUGHOUT NONE DETECTED
7 FALSE CEILING TILE P 106 SELECTIVE
THROUGHOUT NONE DETECTED
8 BROWN FLOOR TILE AND MASTIC
MAIN MECHANICAL ROOM (00-04)
SELECTIVE THROUGHOUT
MASTIC: 5% CHRYSOTILE
FLOOR TILE: NONE DETECTED
9 BLACK FLOOR TILE AND MASTIC
MAIN MECHANICAL ROOM (00-04) NONE DETECTED
10 BEIGE FLOOR TILE AND MASTIC
MAIN MECHANICAL ROOM (00-04)
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
11 FIRE PROOFING 2ND FLOOR
MECHANICAL SPACE
NONE DETECTED
12 FIRE PROOFING 2ND FLOOR
MECHANICAL SPACE
NONE DETECTED
13 FIRE PROOFING 2ND FLOOR
MECHANICAL SPACE
NONE DETECTED
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
SAMPLE RESULTS
1900 SW 4TH AVENUE, PORTLAND, OREGON
SAMPLE # SAMPLE DESCRIPTION SAMPLE LOCATION HOMOGENEOUS
AREA ASBESTOS CONTENT
14 FIRE PROOFING 2ND FLOOR
MECHANICAL SPACE
NONE DETECTED
15 FALSE CEILING TILE 2ND FLOOR SELECTIVE
THROUGHOUT NONE DETECTED
16 DUCT INSULATION MASTIC
FAN ROOM 2A AND B
SELECTIVE THROUGHOUT NONE DETECTED
17 DUCT TAPE FAN ROOM 2A AND B NONE DETECTED
18 LIGHT BROWN
FLOOR TILE AND MASTIC
WEST STAIRWAY NONE DETECTED
19 BEIGE FLOOR TILE AND MASTIC
2ND FLOOR PHONE ROOM
SELECTIVE THROUGHOUT 2ND
FLOOR IN CORE AREA UNDER
CARPET AND AS 1ST AND 2ND LAYERS,
ROOM 211
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
20 DUCT INSULATION MASTIC
PLAZA LEVEL FAN ROOM 1 AI THROUGHOUT NONE DETECTED
21 DUCT TAPE PLAZA LEVEL FAN ROOM 1 AI NONE DETECTED
22 FIRE DOOR CORE PLAZA LEVEL ELECTRICAL ROOM THROUGHOUT NONE DETECTED
23 GRAY FLOOR TILE AND MASTIC STORAGE ROOM 170 NONE DETECTED
24 FALSE CEILING TILE
STORAGE ROOM 115
SELECTIVE THROUGHOUT NONE DETECTED
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682
PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
SAMPLE RESULTS
1900 SW 4TH AVENUE, PORTLAND, OREGON
SAMPLE # SAMPLE DESCRIPTION SAMPLE LOCATION HOMOGENEOUS
AREA ASBESTOS CONTENT
25 PIPE JOINT INSULATION
MECHANICAL ROOM SFG8
NO MORE ENCOUNTERED
HOWEVER MAY BE PRESENT BEHIND
WALLS THROUGHOUT
15% AMOSITE
26 PIPE INSULATION MECHANICAL
ROOM SFG8 LOWER LEVEL
SELECTIVE THROUGHOUT NONE DETECTED
27 BEIGE FLOOR TILE AND MASTIC ROOM 20-12
THROUGHOUT LOWER LEVEL
NORTH
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
28 BEIGE FLOOR TILE AND MASTIC
AT DOORWAY ROOM 55
THROUGHOUT LOWER LEVEL
NORTH
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
29 GRAY FLOOR TILE AND MASTIC
ST 40 CONFERENCE ROOM BREAK ROOM ST 40 NONE DETECTED
30 GREEN FLOOR TILE AND MASTIC ST 40 NONE DETECTED
31 PINK FLOOR TILE AND MASTIC ST 55-17 NONE DETECTED
32 COVE BASE MASTIC ST 55-17 THROUGHOUT NONE DETECTED
33 GYPSUM WALLBOARD ST 55-17 NONE DETECTED
34 FIRE PROOFING LOADING DOCK NONE DETECTED
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682
PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
SAMPLE RESULTS
1900 SW 4TH AVENUE, PORTLAND, OREGON
SAMPLE # SAMPLE DESCRIPTION SAMPLE LOCATION HOMOGENEOUS
AREA ASBESTOS CONTENT
35 FIRE PROOFING LOADING DOCK NONE DETECTED
36 FIRE PROOFING LOADING DOCK NONE DETECTED
37 BROWN FLOOR TILE AND MASTIC
ELECTRICAL ROOM (00-22)
ADJACENT ELECTRICAL ROOM
(00-22)
MASTIC: 5% CHRYSOTILE
FLOOR TILE: NONE DETECTED
38 GRAY FLOOR TILE AND MASTIC
ELECTRICAL ROOM (00-22) NONE DETECTED
39 TAN FLOOR TILE AND MASTIC 85 LOWER LEVEL
SELECTIVE THROUGHOUT
CENTER SECTOR LOWER LEVEL
NONE DETECTED
40 BLACK SHEET VINYL
CENTRAL LOWER LEVEL NONE DETECTED
41 WHITE FLOOR TILE AND MASTIC
CENTRAL LOWER LEVEL NONE DETECTED
42 FALSE CEILING TILE
CENTRAL LOWER LEVEL NONE DETECTED
43 COVE BASE MASTIC CENTRAL LOWER LEVEL NONE DETECTED
44 GYPSUM WALLBOARD
CENTRAL LOWER LEVEL NONE DETECTED
45 PIPE JOINT INSULATION
LOWER LEVEL L080-00
SELECTIVE THROUGHOUT NONE DETECTED
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
SAMPLE RESULTS
1900 SW 4TH AVENUE, PORTLAND, OREGON
SAMPLE # SAMPLE DESCRIPTION SAMPLE LOCATION HOMOGENEOUS
AREA ASBESTOS CONTENT
46 PIPE JOINT INSULATION
LOWER LEVEL L080-00
SELECTIVE THROUGHOUT NONE DETECTED
47 PIPE JOINT INSULATION
LOWER LEVEL L080-00
SELECTIVE THROUGHOUT NONE DETECTED
48 SPRAYED ON FIRE PROOFING
ABOVE CEILING LOWER LEVEL
CENTRAL THROUGHOUT NONE DETECTED
49 PIPE JOINT INSULATION G090 IN WALL SELECTIVE
THROUGHOUT NONE DETECTED
50 SKIM COAT G090 INSIDE WALL SELECTIVE THROUGHOUT NONE DETECTED
51 TAN FLOOR TILE AND MASTIC
STAIR LANDING #3 LOWER LEVEL
SELECTIVE THROUGHOUT
THESE LANDINGS
MASTIC: 5% CHRYSOTILE
FLOOR TILE: NONE DETECTED
52 TAN FLOOR TILE AND MASTIC
TOP LAYER CLASSROOM 2501 NONE DETECTED
53 ORANGE FLOOR TILE AND MASTIC
BOTTOM LAYER CLASS ROOM 2501
BOTTOM LAYER 00-22 NONE DETECTED
54 CREAM FLOOR TILE AND MASTIC TOP LAYER 00-07 NONE DETECTED
55 SPOTTED BROWN FLOOR TILE AND
MASTIC TOP LAYER 00-07 NONE DETECTED
56 TAN FLOOR TILE AND MASTIC
BOTTOM LAYER 00-07
MASTIC: 5% CHRYSOTILE
FLOOR TILE: NONE DETECTED
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682
PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
SAMPLE RESULTS
1900 SW 4TH AVENUE, PORTLAND, OREGON
SAMPLE # SAMPLE DESCRIPTION SAMPLE LOCATION HOMOGENEOUS
AREA ASBESTOS CONTENT
57 BEIGE FLOOR TILE AND MASTIC
2ND FLOOR ROOM 211
SELECTIVE THROUGHOUT 2ND
FLOOR IN CORE AREA UNDER
CARPET AND AS 1ST AND 2ND LAYERS
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
58 COVE BASE MASTIC 2ND FLOOR ROOM 211
SELECTIVE THROUGHOUT NONE DETECTED
59 PLASTER 2ND FLOOR ROOM 211 THROUGHOUT NONE DETECTED
60 GRAY SHEET VINYL ROOM 209 NONE DETECTED
61 WHITE FLOOR TILE AND MASTIC ROOM 209 CLOSET NONE DETECTED
62 GRAY FLOOR TILE AND MASTIC
TOP LAYER ROOM 212
SELECTIVE THROUGHOUT 2ND FLOOR AS 1ST AND
2ND LAYERS, BOTTOM LAYER 210
NONE DETECTED
63 GRAY FLOOR TILE AND MASTIC
BOTTOM LAYER ROOM 212 NONE DETECTED
64 FLOOR COVERING AND MASTIC
TOP LAYER ROOM 210 NONE DETECTED
65 GYPSUM WALLBOARD
OUTSIDE LAYER PLAZA LEVEL
HALLWAY THROUGHOUT NONE DETECTED
66 GYPSUM WALLBOARD
INSIDE LAYER PLAZA LEVEL
HALLWAY THROUGHOUT NONE DETECTED
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682
PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
SAMPLE RESULTS
1900 SW 4TH AVENUE, PORTLAND, OREGON
SAMPLE # SAMPLE DESCRIPTION SAMPLE LOCATION HOMOGENEOUS
AREA ASBESTOS CONTENT
67 CEILING TILE HALLWAY PLAZA LEVEL THROUGHOUT NONE DETECTED
68 CEILING TILE ROOM 175 NONE DETECTED
69 PLASTER MECHANICAL ROOM 175
SELECTIVE THROUGHOUT NONE DETECTED
70 LIGHT BROWN
FLOOR TILE AND MASTIC
ROOM 140 SELECTIVE
THROUGHOUT THIS AREA
NONE DETECTED
71 GRAY FLOOR TILE AND MASTIC ROOM 170 SELECTIVE
THROUGHOUT NONE DETECTED
72 CEILING TILE ROOM 170 NONE DETECTED
73 COVE BASE MASTIC ROOM 170 NONE DETECTED
74 DUCT INSULATION MASTIC ROOM 120 THROUGHOUT NONE DETECTED
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
ASSESSMENT OF MATERIALS
Building: 1900 SW 4TH AVENUE, PORTLAND, OREGON
Sample #'s
Functional Space Asbestos Type %
Material & Condition Comments Sq. & Linear Footage
8, 37
MAIN MECHANICAL ROOM (00-04), ELECTRICAL ROOM (00-22),
ADJACENT ELECTRICAL ROOM (00-22)
CHRYSOTILE 5% BROWN FLOOR
TILE MASTIC (GOOD)
SEE RESPONSE ACTIONS
1,200 SQ FT
25 MECHANICAL ROOM SFG8 AMOSITE 15% PIPE JOINT
INSULATION
SEE RESPONSE ACTIONS
4 VISIBLE FITTINGS
Inspector: Tom Thompson - Accreditation Number: 1000987
Signature: __________________________________ Date: January 10, 2003
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
ASSESSMENT OF MATERIALS
Building: 1900 SW 4TH AVENUE, PORTLAND, OREGON
Sample #'s
Functional Space Asbestos Type %
Material & Condition Comments Sq. & Linear Footage
10, 19, 27, 28, 57
MAIN MECHANICAL
ROOM (00-04), 2ND FLOOR PHONE
ROOM, SELECTIVE
THROUGHOUT 2ND FLOOR IN CORE
AREA UNDER CARPET AND AS
1ST AND 2ND LAYERS, ROOM 211, ROOM 20-12, THROUGHOUT LOWER LEVEL
NORTH, AT DOORWAY ROOM
55
CHRYSOTILE 3% TO 6%
BEIGE FLOOR TILE AND MASTIC
(GOOD)
SEE RESPONSE ACTIONS
APPROX. 30,805 SQ
FT
Inspector: Tom Thompson - Accreditation Number: 1000987
Signature: __________________________________ Date: January 10, 2003
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
ASSESSMENT OF MATERIALS
Building: 1900 SW 4TH AVENUE, PORTLAND, OREGON
Sample #'s
Functional Space Asbestos Type %
Material & Condition Comments Sq. & Linear Footage
51, 56
STAIR LANDING # 3 LOWER LEVEL,
SELECTIVE THROUGHOUT
THESE LANDINGS, BOTTOM LAYER
00-07
CHRYSOTILE 5% TAN FLOOR TILE
MASTIC (GOOD)
SEE RESPONSE ACTIONS
APPROX. 650 SQ FT
Inspector: Tom Thompson - Accreditation Number: 1000987
Signature: __________________________________ Date: November 22, 2002
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
RESPONSE ACTIONS RECOMMENDED
Building: 1900 SW 4TH AVENUE, PORTLAND, OREGON
MATERIAL LOCATION RECOMMENDED RESPONSE ACTIONS
FLOOR TILE MASTIC
MAIN MECHANICAL ROOM (00-04), ELECTRICAL ROOM
(00-22), THROUGHOUT, STAIR LANDING #3 LOWER LEVEL, SELECTIVE THROUGHOUT
THESE LANDINGS, BOTTOM LAYER 00-07
Floor tile mastic is a non- friable material that poses minimal health or environmental risks in its current state. Non-asbestos floor tile with asbestos containing mastic must be assumed to be contaminated. Do not drill through, sand on, puncture, break or otherwise disturb material.
PIPE JOINT INSULATION MECHANICAL ROOM SFG8
Pipe joint insulation is a friable material that is currently in good condition. Must be maintained in an intact condition and kept encapsulated with a high vehicular latex paint. Do not drill through, sand on or otherwise disturb material. Must be removed prior to renovation or demolition. Pipe joint insulation between walls must be removed prior to demolition or renovation. * Quantity of material is an estimate only. Destructive testing was not an option and piping blue prints were not available and all non- visible pipes behind walls must be assumed to be asbestos containing.
Management Planner: Tom Thompson - Accreditation Number: 1001009 Signature: ________________________________ Date: January 10, 2003
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
RESPONSE ACTIONS RECOMMENDED
Building: 1900 SW 4TH AVENUE, PORTLAND, OREGON
MATERIAL LOCATION RECOMMENDED RESPONSE ACTIONS
FLOOR TILE AND MASTIC
MAIN MECHANICAL ROOM (00-04), 2ND FLOOR PHONE ROOM, THROUGHOUT 2ND
FLOOR IN CORE AREA UNDER CARPET AND AS 1ST
AND 2ND LAYERS, ROOM 211, ROOM 20-12, THROUGHOUT LOWER LEVEL NORTH, AT
DOORWAY ROOM 55
Floor tile and mastic are non-friable materials that are currently in good condition. Do not drill through, sand on, break or otherwise disturb material. Must be removed prior to renovation or demolition.
Management Planner: Tom Thompson - Accreditation Number: 1001009 Signature: ________________________________ Date: January 10, 2003
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT
MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-06-02 THROUGH 12-10-02 DATE RECEIVED: 12-10-02 DATE COMPLETED: 12-11-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
1 COMPUTER FLOORING
ELECTRICAL MECHANICAL
ROOM SUB BASEMENT
NONE DETECTED EPOXY, VINYL, ADHESIVE
2 COVE BASE MASTIC
ELECTRICAL MECHANICAL
ROOM SUB BASEMENT
NONE DETECTED ADHESIVE, CLAY
3 PIPE JOINT INSULATION
BATTERY ROOM SUB BASEMENT NONE DETECTED 30% FIBERGLASS,
CALCIUM SILICATE
4 PIPE JOINT INSULATION
MEN’S RESTROOM
LOWER LEVEL NONE DETECTED 30% FIBERGLASS,
CALCIUM SILICATE,
5 GYPSUM WALLBOARD
OUTSIDE LAYER P2 NONE DETECTED
20% CELLULOSE, 3% FIBERGLASS,
CALCIUM SULFATE, BINDER
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-06-02 THROUGH 12-10-02 DATE RECEIVED: 12-10-02 DATE COMPLETED: 12-11-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
6 GYPSUM WALLBOARD INSIDE LAYER P2 NONE DETECTED
20% CELLULOSE, 3% FIBERGLASS,
CALCIUM SULFATE, BINDER
7 FALSE CEILING TILE P106 NONE DETECTED 65% CELLULOSE, PERLITE, BINDER
8 BROWN FLOOR TILE AND MASTIC
MAIN MECHANICAL ROOM (00-04)
MASTIC: 5% CHRYSOTILE
FLOOR TILE: NONE DETECTED
CALCIUM CARBONATE, VINYL, BINDER, TAR
9 BLACK FLOOR TILE AND MASTIC
MAIN MECHANICAL ROOM (00-04)
NONE DETECTED CALCIUM CARBONATE, VINYL, BINDER, ADHESIVE
10 BEIGE FLOOR TILE AND MASTIC
MAIN MECHANICAL ROOM (00-04)
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
CALCIUM CARBONATE, VINYL, BINDER, TAR
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-06-02 THROUGH 12-10-02 DATE RECEIVED: 12-10-02 DATE COMPLETED: 12-11-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
11 FIRE PROOFING 2ND FLOOR
MECHANICAL SPACE
NONE DETECTED 20% CELLULOSE,
CALCIUM SILICATE, BINDER
12 FIRE PROOFING 2ND FLOOR
MECHANICAL SPACE
NONE DETECTED 15% CELLULOSE, 8% FIBERGLASS, MICA, CALCITE
13 FIRE PROOFING 2ND FLOOR
MECHANICAL SPACE
NONE DETECTED 20% CELLULOSE,
CALCIUM SILICATE, FERROUS OXIDE
14 FIRE PROOFING 2ND FLOOR
MECHANICAL SPACE
NONE DETECTED 15% CELLULOSE, 8% FIBERGLASS, MICA, CALCITE
15 FALSE CEILING TILE 2ND FLOOR NONE DETECTED 50% CELLULOSE, PERLITE, BINDER
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-06-02 THROUGH 12-10-02 DATE RECEIVED: 12-10-02 DATE COMPLETED: 12-11-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
16 DUCT INSULATION MASTIC
FAN ROOM 2A AND B NONE DETECTED ADHESIVE,
CALCIUM CARBONATE
17 DUCT TAPE FAN ROOM 2A AND B NONE DETECTED 60% CELLULOSE,
CALCITE, ADHESIVE
18 LIGHT BROWN
FLOOR TILE AND MASTIC
WEST STAIRWAY NONE DETECTED CALCIUM CARBONATE, VINYL, BINDER, ADHESIVE
19 BEIGE FLOOR TILE AND MASTIC
2ND FLOOR PHONE ROOM
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
CALCIUM CARBONATE, VINYL, BINDER, TAR
20 DUCT INSULATION MASTIC
PLAZA LEVEL FAN ROOM 1AI NONE DETECTED ADHESIVE,
CALCIUM CARBONATE
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-06-02 THROUGH 12-10-02 DATE RECEIVED: 12-10-02 DATE COMPLETED: 12-11-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
21 DUCT TAPE PLAZA LEVEL FAN ROOM 1 AI NONE DETECTED 60% CELLULOSE,
CALCITE, ADHESIVE
22 FIRE DOOR CORE PLAZA LEVEL ELECTRICAL
ROOM NONE DETECTED 15% FIBERGLASS,
PERLITE, CALCITE, BINDER
23 GRAY FLOOR TILE AND MASTIC
STORAGE ROOM 170 NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
24 FALSE CEILING TILE STORAGE ROOM 115 NONE DETECTED 50% CELLULOSE,
PERLITE, BINDER
25 PIPE JOINT INSULATION
MECHANICAL ROOM SFG8 15% AMOSITE MAGNESIUM CARBONATE
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-06-02 THROUGH 12-10-02 DATE RECEIVED: 12-10-02 DATE COMPLETED: 12-11-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
26 PIPE INSULATION MECHANICAL
ROOM SFG8 LOWER LEVEL
NONE DETECTED 65% FIBERGLASS, 20% CELLULOSE, FOIL, ADHESIVE
27 BEIGE FLOOR TILE AND MASTIC ROOM 20-12
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
CALCIUM CARBONATE, VINYL, BINDER, TAR
28 BEIGE FLOOR TILE AND MASTIC
AT DOORWAY ROOM 55
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
CALCIUM CARBONATE, VINYL, BINDER, TAR
29 GRAY FLOOR TILE AND MASTIC
ST 40 CONFERENCE
ROOM NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
30 GREEN FLOOR TILE AND MASTIC ST 40 NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-06-02 THROUGH 12-10-02 DATE RECEIVED: 12-10-02 DATE COMPLETED: 12-11-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
31
PINK FLOOR TILE AND MASTIC ST 55-17 NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
32 COVE BASE MASTIC ST 55-17 NONE DETECTED SILICONE CEMENT
33 GYPSUM WALLBOARD ST 55-17 NONE DETECTED
20% CELLULOSE, 3% FIBERGLASS,
CALCIUM SULFATE, BINDER
34 FIRE PROOFING LOADING DOCK NONE DETECTED 15% CELLULOSE, 8% FIBERGLASS, MICA, CALCITE
35 FIRE PROOFING LOADING DOCK NONE DETECTED 15% CELLULOSE, 8% FIBERGLASS, MICA, CALCITE
36 FIRE PROOFING LOADING DOCK NONE DETECTED 15% CELLULOSE, 8% FIBERGLASS, MICA, CALCITE
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-09-02 DATE RECEIVED: 12-09-02 DATE COMPLETED: 12-26-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
37 BROWN FLOOR TILE AND MASTIC
ELECTRICAL ROOM (00-22)
MASTIC: 5% CHRYSOTILE
FLOOR TILE: NONE DETECTED
CALCIUM CARBONATE, VINYL, BINDER, TAR
38 GRAY FLOOR TILE AND MASTIC
ELECTRICAL ROOM (00-22) NONE DETECTED
1% CELLULOSE CALCIUM CARBONATE,
VINYL, BINDER, TAR
39 TAN FLOOR TILE AND MASTIC 85 LOWER LEVEL NONE DETECTED
1% CELLULOSE, CALCIUM CARBONATE,
VINYL, BINDER, TAR
40 BLACK SHEET VINYL
CENTRAL LOWER LEVEL NONE DETECTED
10% CELLULOSE, VINYL, CALCITE,
ADHESIVE
41 WHITE FLOOR TILE AND MASTIC
CENTRAL LOWER LEVEL NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-09-02 DATE RECEIVED: 12-09-02 DATE COMPLETED: 12-26-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
42 FALSE CEILING TILE CENTRAL LOWER LEVEL NONE DETECTED 65% CELLULOSE,
PERLITE, BINDER
43 COVE BASE MASTIC CENTRAL LOWER LEVEL NONE DETECTED SILICONE CEMENT
44 GYPSUM WALLBOARD
CENTRAL LOWER LEVEL NONE DETECTED
20% CELLULOSE, CALCIUM SULFATE,
BINDER
45 PIPE JOINT INSULATION
LOWER LEVEL L080-00 NONE DETECTED 30% FIBERGLASS,
CALCIUM SILICATE
46 PIPE JOINT INSULATION
LOWER LEVEL L080-00 NONE DETECTED 30% FIBERGLASS,
CALCIUM SILICATE
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-09-02 DATE RECEIVED: 12-09-02 DATE COMPLETED: 12-26-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
47 PIPE JOINT INSULATION
LOWER LEVEL L080-00 NONE DETECTED 30% FIBERGLASS,
CALCIUM SILICATE
48 SPRAYED ON FIRE PROOFING
ABOVE CEILING LOWER LEVEL
CENTRAL NONE DETECTED 20% CELLULOSE,
CALCIUM SILICATE
49 PIPE JOINT INSULATION G090 IN WALL NONE DETECTED 30% FIBERGLASS,
CALCIUM SILICATE
50 SKIM COAT G090 INSIDE WALL NONE DETECTED CALCIUM CARBONATE,
QUARTZ, CEMENT
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-30-02 DATE RECEIVED: 12-30-02 DATE COMPLETED: 12-31-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
51 TAN FLOOR TILE AND MASTIC
STAIR LANDING #3 LOWER LEVEL
MASTIC: 5% CHRYSOTILE
FLOOR TILE: NONE DETECTED
CALCIUM CARBONATE, VINYL, BINDER, TAR
52 TAN FLOOR TILE AND MASTIC
TOP LAYER CLASSROOM 2501 NONE DETECTED
1% CELLULOSE, CALCIUM CARBONATE,
VINYL, BINDER, TAR
53 ORANGE FLOOR TILE AND MASTIC
BOTTOM LAYER CLASSROOM 2501 NONE DETECTED
1% CELLULOSE, CALCIUM CARBONATE,
VINYL, BINDER, TAR
54 CREAM FLOOR TILE AND MASTIC TOP LAYER 00-07 NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
55 SPOTTED BROWN FLOOR TILE AND
MASTIC TOP LAYER 00-07 NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 12-30-02 DATE RECEIVED: 12-30-02 DATE COMPLETED: 12-31-02
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
56 TAN FLOOR TILE AND MASTIC
BOTTOM LAYER 00-07
MASTIC: 5% CHRYSOTILE
FLOOR TILE: NONE DETECTED
CALCIUM CARBONATE, VINYL, BINDER, TAR
57 BEIGE FLOOR TILE AND MASTIC
2ND FLOOR ROOM 211
FLOOR TILE: 3% CHRYSOTILE
MASTIC: 6% CHRYSOTILE
TRACE <1% CELLULOSE,
CALCIUM CARBONATE, VINYL, BINDER, TAR
58 COVE BASE MASTIC 2ND FLOOR ROOM 211 NONE DETECTED ADHESIVE, CLAY
59 PLASTER 2ND FLOOR ROOM 211 NONE DETECTED CALCIUM CARBONATE,
PERLITE, CEMENT
60 GRAY SHEET VINYL ROOM 209 NONE DETECTED 10% CELLULOSE, VINYL, CALCITE,
ADHESIVE
61 WHITE FLOOR TILE AND MASTIC
ROOM 209 CLOSET NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
62 GRAY FLOOR TILE AND MASTIC
TOP LAYER ROOM 212 NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
63 GRAY FLOOR TILE AND MASTIC
BOTTOM LAYER ROOM 212 NONE DETECTED
1% CELLULOSE, CALCIUM CARBONATE,
VINYL, BINDER, TAR
64 FLOOR COVERING AND MASTIC
TOP LAYER ROOM 210 NONE DETECTED SYNTHETIC RUBBER,
SILICONE CEMENT
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 01-03-03 DATE RECEIVED: 01-03-03 DATE COMPLETED: 01-06-03
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
65 GYPSUM WALLBOARD
OUTSIDE LAYER PLAZA LEVEL
HALLWAY NONE DETECTED
20% CELLULOSE, 3% FIBERGLASS,
CALCIUM SULFATE, BINDER
66 GYPSUM WALLBOARD
INSIDE LAYER PLAZA LEVEL
HALLWAY NONE DETECTED
20% CELLULOSE, 3% FIBERGLASS,
CALCIUM SULFATE, BINDER
67 CEILING TILE HALLWAY PLAZA LEVEL NONE DETECTED 65% CELLULOSE,
PERLITE, BINDER
68 CEILING TILE ROOM 175 NONE DETECTED 65% CELLULOSE, PERLITE, BINDER
69 PLASTER MECHANICAL ROOM 175 NONE DETECTED CALCIUM CARBONATE,
AGGREGATE, CEMENT
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT:
CERTIFIED ENVIRONMENTAL CONSULTING, INC.
BULK SAMPLE ANALYSIS REPORT MR. RUBEN TORRES SOURCE: 1900 SW 4TH AVENUE, PORTLAND, OREGON PORTLAND STATE UNIVERSITY SAMPLED BY: TOM THOMPSON
630 SW MILL STREET LAB #: N-2217/02-1009 PORTLAND, OREGON 97201 ANALYZED BY: TOM THOMPSON
DATE SAMPLED: 01-03-03 DATE RECEIVED: 01-03-03 DATE COMPLETED: 01-06-03
ANALYTICAL METHOD: EPA, 40 CFR Part 763, Section 1, Subpart F, Appendix A, PLM/Dispersion Staining
SAMPLE
ID #
SAMPLE DESCRIPTION
SAMPLE LOCATION
ASBESTOS CONTENT
OTHER MATERIAL
70 LIGHT BROWN
FLOOR TILE AND MASTIC
ROOM 140 NONE DETECTED CALCIUM CARBONATE, VINYL, BINDER, ADHESIVE
71 GRAY FLOOR TILE AND MASTIC ROOM 170 NONE DETECTED CALCIUM CARBONATE,
VINYL, BINDER, ADHESIVE
72 CEILING TILE ROOM 170 NONE DETECTED 60% CELLULOSE, PERLITE, BINDER
73 COVE BASE MASTIC ROOM 170 NONE DETECTED SILICONE CEMENT
74 DUCT INSULATION MASTIC ROOM 120 NONE DETECTED CALCITE, ADHESIVE
ANALYST:______________________________________________ REVIEWED BY:_________________ DEVIATION FROM METHOD: NONE. PERCENTAGES ARE ESTIMATES. TEST RESULTS PERTAIN ONLY TO ITEMS TESTED. * DETECTION LIMIT IS LESS THAN 1% ASBESTOS. NON ASBESTOS MATERIALS ARE NOT NECESSARILY LISTED.
12806 N.E. 40TH CIRCLE VANCOUVER, WASHINGTON 98682 PORTLAND (503) 221-7904 VANCOUVER (360) 254-9385 Fax (360) 891-9633
CLIENT: