arun®100 solar boiler / solar thermal concentrator with ... · clique developments limited |149...

4
Clique Developments Limited |149 BCD, F Phone: +91 22 2860 9011 | Fax: +91 ARUN®100 Solar w at Ramkri First Floor, Government Industrial Estate, Charkop, Kandivali (W 22 2860 9734 | Email: [email protected] | Website: www.c r Boiler / Solar Thermal concent with Thermal Storage ishna Mission Students Home, Chennai W), Mumbai - 400 067 cliquesolar.com trator

Upload: others

Post on 23-Aug-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ARUN®100 Solar Boiler / Solar Thermal concentrator with ... · Clique Developments Limited |149 BCD, First Floor, Phone : +91 22 2860 9011 | Fax: +91 22 2860 9734 | ARUN®100 Solar

Clique Developments Limited |149 BCD, First Floor,

Phone: +91 22 2860 9011 | Fax: +91 22 2860 9734 |

ARUN®100 Solar Boiler / Solar Thermal concentrator

with Thermal Storage

at Ramkrishna

First Floor, Government Industrial Estate, Charkop, Kandivali (W), Mumbai

: +91 22 2860 9011 | Fax: +91 22 2860 9734 | Email: [email protected] | Website: www.cliquesolar.com

Solar Boiler / Solar Thermal concentrator

with Thermal Storage

amkrishna Mission Students Home,

Chennai

(W), Mumbai - 400 067

www.cliquesolar.com

Solar Boiler / Solar Thermal concentrator

Page 2: ARUN®100 Solar Boiler / Solar Thermal concentrator with ... · Clique Developments Limited |149 BCD, First Floor, Phone : +91 22 2860 9011 | Fax: +91 22 2860 9734 | ARUN®100 Solar

Contact:

Abhishek Bhatewara | Clique Solar | M: 909 618 00002

The Project

Ramakrishna Mission Students Home, Chennai wanted to install a solar thermal system to

reduce their dependence and incremental expenditure on LPG used for cooking.

Requirement as stated by the client:

o Heat / steam required for cooking breakfast, lunch, snacks, dinner for 700 students

o The project should be handled on turnkey basis including complete integration with

the existing system

o The solar thermal installation should occupy minimum footprint area

Requirement analyses by Clique Solar

o Breakfast preparation starts as early as 4 am. Thus, steam required during non-solar

hours as well

Recommendation made

1 ARUN®100 solar thermal concentrator with energy storage arrangement generating 540 kg of

steam/day during solar hours on a clear sunny day, satisfying the complete energy requirement

for cooking and hot water, resulting in 100% LPG fuel saving of 30 - 40 kg per day (depending on

the usage).

Installation of the Project:The system was commissioned on 26th

October 2013.

Project highlights

• Steam available round the clock though provision given for energy storage. Steam

Storage has been provided for cooking breakfast at 4 a.m.

• System is installed on roof top of existing building

• Cooks about 2000-3000 meals per day

Project Summary

Date of Completion October 2013

Steam Delivery 7 bar steam / 170°C

No of meals cooked on solar About 2,000 to 3,000 meals on a sunny day

Average Fuel Savings 30 to 40 kg of LPG on a clear sunny day

Page 3: ARUN®100 Solar Boiler / Solar Thermal concentrator with ... · Clique Developments Limited |149 BCD, First Floor, Phone : +91 22 2860 9011 | Fax: +91 22 2860 9734 | ARUN®100 Solar

Contact:

Abhishek Bhatewara | Clique Solar | M: 909 618 0000

Integration Schematic

Operating Philosophy

The basic aim of the control system in this integration scheme is to deliver steam to the existing

boiler header and excess steam to be delivered to thermal storage for non

operation.

The ARUN dish automatically tracks the sun from morning to

focus of the dish transfers the heat of the sun to the heat transfer medium (water). “The Steam

generation system with Storage” consists of ARUN®100 dish, thermal storage, pumps, valves,

etc. Once the system starts generat

delivered to the common header of existing boiler system. If there is reduction in steam usage

by the process (due to holiday, break, etc), the upstream pressure increases causing a valve to

open, thereby delivering steam to the storage tank. This process continues whenever the sun is

available. When the sun is not available, steam is first generated from the storage tank.

Thereafter the existing boiler system is turned on.

ARUN®100 Technology Details

Aperture Area

Footprint Area

Temperature Rating

Abhishek Bhatewara | Clique Solar | M: 909 618 00003

The basic aim of the control system in this integration scheme is to deliver steam to the existing

boiler header and excess steam to be delivered to thermal storage for non

The ARUN dish automatically tracks the sun from morning to evening. The receiver coil at the

focus of the dish transfers the heat of the sun to the heat transfer medium (water). “The Steam

generation system with Storage” consists of ARUN®100 dish, thermal storage, pumps, valves,

etc. Once the system starts generating steam and required pressure is achieved, the steam is

delivered to the common header of existing boiler system. If there is reduction in steam usage

by the process (due to holiday, break, etc), the upstream pressure increases causing a valve to

hereby delivering steam to the storage tank. This process continues whenever the sun is

available. When the sun is not available, steam is first generated from the storage tank.

Thereafter the existing boiler system is turned on.

104 sq.m.

3m x 3m = 9 sq.m.

Peak delivery of 350°C

The basic aim of the control system in this integration scheme is to deliver steam to the existing

boiler header and excess steam to be delivered to thermal storage for non-solar hours

evening. The receiver coil at the

focus of the dish transfers the heat of the sun to the heat transfer medium (water). “The Steam

generation system with Storage” consists of ARUN®100 dish, thermal storage, pumps, valves,

ing steam and required pressure is achieved, the steam is

delivered to the common header of existing boiler system. If there is reduction in steam usage

by the process (due to holiday, break, etc), the upstream pressure increases causing a valve to

hereby delivering steam to the storage tank. This process continues whenever the sun is

available. When the sun is not available, steam is first generated from the storage tank.

Page 4: ARUN®100 Solar Boiler / Solar Thermal concentrator with ... · Clique Developments Limited |149 BCD, First Floor, Phone : +91 22 2860 9011 | Fax: +91 22 2860 9734 | ARUN®100 Solar

Contact:

Abhishek Bhatewara | Clique Solar | M: 909 618 0000

Thermal Output Rating

Tracking System

Estimated Life of System

Need for Thermal Energy Storage in Cooking

tank. It is used at times when solar energy is not available for the cook

shaded area).

Abhishek Bhatewara | Clique Solar | M: 909 618 00004

Peak delivery of 3,50,000 kcal/day

Fully automatic two-axes tracking system

20 years +

Need for Thermal Energy Storage in Cooking

A typical energy requirement in

community cooking setting is

shown in the graph below in

blue line. The red curve shows

the energy generation with

solar system.

It is seen from the above graph

that there is

timings between the cooking

energy demand and solar

energy supply. The red shaded

area (solar energy delivered in

excess of requirement) is

stored in a thermal storage

tank. It is used at times when solar energy is not available for the cooking requirement (blue

A typical energy requirement in

community cooking setting is

shown in the graph below in

blue line. The red curve shows

the energy generation with

It is seen from the above graph

a mismatch in

timings between the cooking

energy demand and solar

energy supply. The red shaded

area (solar energy delivered in

excess of requirement) is

stored in a thermal storage

ing requirement (blue