architect and engineer specifications9 petrochemical plants 9 pharmaceutical industry 9...

4
Triple IR (IR3) Flame Detector > Model 40/40I 6207 s Industry, Inc. Building Technologies Division s Catalog Sheet Fire Safety & Security Products Specialized Detection Devices Triple IR (IR3) Flame Detector Model 40/40I ARCHITECT AND ENGINEER SPECIFICATIONS Explosion proof Triple-spectrum design Sensitivity selection RS-485 Interface Heated window User-programmable configuration Resistant to false alarms Automatic and manual built-in-test (BIT) MTBF minimum of 150,000 hours 0-20mA source configuration Stepped Product Overview Ratings The Triple IR (IR3) Flame Detector is a reliable, compact and self-contained triple-spectrum infrared flame detector that detects fuel and gas fires at long distances with the highest immunity to false alarms. Model 40/40I ( IR3) can detect a 1ft 2 (0.1m 2 ) gasoline pan fire at 215 ft (65m) in less than 5 seconds. Model (40/40I) has considerable durability and weather-related resistance, and is comprised of the following characteristics: Heated window, eliminating condensation and icing Highway Addressable Remote Transducer (HART) capabilities, for digital communications low-power requirements A compact, lighter design Due to increased reliability, Model 40/40I is SIL2 (TUV) Approved to IEC 61508. General: Adjustable Time Delay: Up to 30 seconds Spectral Response: Three (3) IR Bands Response Time: Typical: 5 seconds Sensitivity Range: Four (4) sensitivity ranges for 1 ft 2 (0.1m 2 ) n-Heptane pan fire from 50 ft (15m) to 215 ft (65m) Built-in-Test: Manual and Automatic BIT Field of View: 100° horizontal, 95° vertical Heated Optics: To eliminate condensation and icing on the window Operating: -67°F (-55°C) to 167°F (75°C) Optional: -67°F (-55°C) to 185°F (85°C) Environmental Ranges: {up to 95% RH} Storage: -67°F (-55°C) to 185°F (85°C) Diesel-fuel fire at 150 ft (45m) 95% Ethanol fire at 135 ft (40m) Gasoline fire at 215 ft (65m) IPA (Isopropyl Alcohol) fire at 135 ft (40m) JP5 fire at 150 ft (45m) Kerosene fire at 150 ft (45m) LPG* fire at 100 ft (30m) Methane* fire at 100 ft (30m) Methanol fire at 115 ft (35m) n-Heptane fire at 215 ft (65m) Office paper fire at 33 ft (10m) Detection Ranges: {at highest sensitivity setting for 1ft 2 [0.1m 2 ] pan fire} Polypropylene Pellets fire at 16 ft (5m) * denotes 20’’ (O.5m) high, 8’’ (0.2m) wide plume fire ATEX; CSA; CSFM; DNV; EN54-10 (LPCB); FM; FMC; IECEx; GOST R, and SIL2 (TUV) Approved (713)-395-1508 Fax: (713) 893-6924 [email protected] www.industrialzone.com IndustrialZone P.O. Box 667306 Houston, Texas 77266 United States

Upload: others

Post on 11-Mar-2020

12 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ARCHITECT AND ENGINEER SPECIFICATIONS9 Petrochemical plants 9 Pharmaceutical industry 9 Power-generation facilities: Pumps, generator rooms and unmanned stations 9 Printing industry

Triple IR (IR3) Flame Detector ─> Model 40/40I 6207 s Industry, Inc. Building Technologies Division

s Catalog Sheet 

Fire Safety & Security Products 

Specialized Detection Devices Triple IR (IR3) Flame Detector Model 40/40I

ARCHITECT AND ENGINEER SPECIFICATIONS• Explosion proof

• Triple-spectrum design

• Sensitivity selection

• RS-485 Interface

• Heated window

• User-programmable configuration

• Resistant to false alarms

• Automatic and manual built-in-test (BIT)

• MTBF minimum of 150,000 hours

• 0-20mA source configuration Stepped

Product Overview RatingsThe Triple IR (IR3) Flame Detector is a reliable, compact and self-contained triple-spectrum infrared flame detector that detects fuel and gas fires at long distances with the highest immunity to false alarms. Model 40/40I (IR3) can detect a 1ft2 (0.1m2) gasoline pan fire at 215 ft (65m) in less than 5 seconds.

Model (40/40I) has considerable durability and weather-related resistance, and is comprised of the following characteristics:

Heated window, eliminating condensation and icing

Highway Addressable Remote Transducer (HART) capabilities, for digital communications low-power requirements

A compact, lighter design

Due to increased reliability, Model 40/40I is SIL2 (TUV) Approved to IEC 61508.

General: Adjustable Time Delay: Up to 30 seconds

Spectral Response: Three (3) IR Bands

Response Time: Typical: 5 seconds

Sensitivity Range: Four (4) sensitivity ranges for 1 ft2 (0.1m2) n-Heptane pan fire from 50 ft (15m) to 215 ft (65m)

Built-in-Test: Manual and Automatic BIT

Field of View: 100° horizontal, 95° vertical

Heated Optics: To eliminate condensation and icing on the window

Operating: -67°F (-55°C) to 167°F (75°C)

Optional: -67°F (-55°C) to 185°F (85°C)

Environmental Ranges:

{up to 95% RH} Storage: -67°F (-55°C) to 185°F (85°C) Diesel-fuel fire at 150 ft (45m) 95% Ethanol fire at 135 ft (40m) Gasoline fire at 215 ft (65m) IPA (Isopropyl Alcohol) fire at 135 ft (40m) JP5 fire at 150 ft (45m) Kerosene fire at 150 ft (45m) LPG* fire at 100 ft (30m) Methane* fire at 100 ft (30m) Methanol fire at 115 ft (35m) n-Heptane fire at 215 ft (65m) Office paper fire at 33 ft (10m)

Detection Ranges:

{at highest sensitivity setting for 1ft2 [0.1m2]

pan fire}

Polypropylene Pellets fire at 16 ft (5m)

* denotes 20’’ (O.5m) high, 8’’ (0.2m) wide plume fire

• ATEX; CSA; CSFM; DNV; EN54-10 (LPCB); FM; FMC; IECEx; GOST R, and SIL2 (TUV) Approved

(713)-395-1508Fax: (713) [email protected]

IndustrialZoneP.O. Box 667306Houston, Texas 77266United States

Page 2: ARCHITECT AND ENGINEER SPECIFICATIONS9 Petrochemical plants 9 Pharmaceutical industry 9 Power-generation facilities: Pumps, generator rooms and unmanned stations 9 Printing industry

s Industry, Inc. Building Technologies Division

Ratings ─ (continued) Electrical:

Power Supply: Operating Voltage: 18-32 VDC

Standby: 90mA, max. {110mA with heated window} Power

Consumptions: Alarm: 130mA, max. {160mA with heated window}

Connection: 2-x-3/4’’ - 14NPT conduits, or 2’’-x-M25-x-0.15cm ISO

Interface: Includes 12 terminals with five (5) factory-set wiring options

Wiring: 12 - 22AWG (0.25cm2 - 0.03cm2)

Input Protection: According to MIL-STD-1275B

Electromagnetic Compatibility:

EMI / RFI protected (to EN61326-3 and EN61000-6-3)

Outputs: Alarm: 5A at 30 VDC or 250 VAC

Fault and Accessory: 5A at 30 VDC or 250 VAC Relays: Fault relay normally closed (NC), others normally open (NO)

Fault: 0 + 1mA BIT Fault: 2mA ± 10 % Normal: 4mA ± 10 % Warning: 16mA ± 5 % Alarm: 20mA ± 5 %

0-20mA stepped: Sink (source-option)

configuration

Resistance Loop: 100-600

HART Protocol

Optional HART communications on the 0-20mA analog current (FSK) -- used for maintenance, configuration changes and asset management. Available in mA source-output wiring options.

RS-485

The detector is equipped with a RS-485 proprietary communication-protocol link that can be used in installations with computerized controllers. The RS-485 link is Modbus® compatible.

Mechanical: Dimensions: 4" x 4.6" x 6.2" (10.2 x 11.8 x 15.8 cm)

Aluminum: 2.8 Lbs (1.3 Kgs) St.St 316L: 6.1 Lbs (2.8 Kgs) Weight: Tilt Mount: 2.2 Lbs (1.0 Kgs)

Enclosure[s]:

Aluminum, heavy-duty and low-copper (less than 1%), red epoxy -enamel finish Optional: Stainless steel 316L with electro-polish finish

Accessories: Model # Part # 40 / 40 Air Shield: 777161 S54430-F307-A1

Fire Simulator: 20/20-311 S54430-F300-A1

Laser Pointer: (Detector-area coverage) 777166 S54430-F309-A1

Mini Laptop Kit: 777820 S54430-F295-A1

USB, RS-485 Harness Kit: 794079-5 S54430-F312-A1

Tilt Mount: 40/40-001 S54430-F304-A1

Weather Protector: 777163 S54430-F308-A1

Applications Aircraft hangars

Automotive industry

Chemical plants

Explosives and munitions

Offshore oil-and-gas installations

Onshore oil-and-gas installations and pipelines

Petrochemical plants

Pharmaceutical industry

Power-generation facilities: Pumps, generator rooms and unmanned stations

Printing industry

Storage-tank farms

Warehouses

Waste-disposal facilities

Details for Ordering Model

Number Part

Number Description

40/40I-111SF S54430-F7-A1 IR3 FLM DET WO1 75C M25 SS FM 40/40I-111SC S54430-F8-A1 IR3 FLM DET WO1 75C M25 SS CTEX

40/40I-111AF S54430-F9-A1 IR3 FLM DET WO1 75C M25 AL FM

40/40I-111AC S54430-F10-A1 IR3 FLM DET WO1 75C M25 AL CTEX

40/40I-112SF S54430-F11-A1 IR3 FLM DET WO1 75C 3/4" SS FM

40/40I-112SC S54430-F12-A1 IR3 FLM DET WO1 75C 3/4" SS CTEX

40/40I-112AF S54430-F13-A1 IR3 FLM DET WO1 75C 3/4" AL FM

40/40I-112AC S54430-F14-A1 IR3 FLM DET WO1 75C 3/4" AL CTEX

40/40I-121SF S54430-F15-A1 IR3 FLM DET WO1 85C M25 SS FM

40/40I-121SC S54430-F16-A1 IR3 FLM DET WO1 85C M25 SS CTEX

40/40I-121AF S54430-F17-A1 IR3 FLM DET WO1 85C M25 AL FM

40/40I-121AC S54430-F18-A1 IR3 FLM DET WO1 85C M25 AL CTEX

40/40I-122SF S54430-F19-A1 IR3 FLM DET WO1 85C 3/4" SS FM

40/40I-122SC S54430-F20-A1 IR3 FLM DET WO1 85C 3/4" SS CTEX

40/40I-122AF S54430-F21-A1 IR3 FLM DET WO1 85C 3/4" AL FM

40/40I-122AC S54430-F22-A1 IR3 FLM DET WO1 85C 3/4" AL CTEX

40/40I-211SF S54430-F23-A1 IR3 FLM DET WO2 75C M25 SS FM

40/40I-211SC S54430-F24-A1 IR3 FLM DET WO2 75C M25 SS CTEX

40/40I-211AF S54430-F25-A1 IR3 FLM DET WO2 75C M25 AL FM

40/40I-211AC S54430-F26-A1 IR3 FLM DET WO2 75C M25 AL CTEX

40/40I-212SF S54430-F27-A1 IR3 FLM DET WO2 75C 3/4" SS FM

40/40I-212SC S54430-F28-A1 IR3 FLM DET WO2 75C 3/4" SS CTEX

40/40I-212AF S54430-F29-A1 IR3 FLM DET WO2 75C 3/4" AL FM

40/40I-212AC S54430-F30-A1 IR3 FLM DET WO2 75C 3/4" AL CTEX

40/40I-221SF S54430-F31-A1 IR3 FLM DET WO2 85C M25 SS FM

40/40I-221SC S54430-F32-A1 IR3 FLM DET WO2 85C M25 SS CTEX

40/40I-221AF S54430-F33-A1 IR3 FLM DET WO2 85C M25 AL FM

40/40I-221AC S54430-F34-A1 IR3 FLM DET WO2 85C M25 AL CTEX

40/40I-222SF S54430-F35-A1 IR3 FLM DET WO2 85C 3/4" SS FM

40/40I-222SC S54430-F36-A1 IR3 FLM DET WO2 85C 3/4" SS CTEX

40/40I-222AF S54430-F37-A1 IR3 FLM DET WO2 85C 3/4" AL FM

40/40I-222AC S54430-F38-A1 IR3 FLM DET WO2 85C 3/4" AL CTEX

Page 3: ARCHITECT AND ENGINEER SPECIFICATIONS9 Petrochemical plants 9 Pharmaceutical industry 9 Power-generation facilities: Pumps, generator rooms and unmanned stations 9 Printing industry

s Industry, Inc. Building Technologies Division

Wiring Configurations ─ Typical ─

Terminal Blocks

5 8 9

Fault Relay 0 ─ 20 mA 0 ─ 20 mA

(N.C.) (N.C.) (Sink)

Fault Relay Alarm Relay 0 ─ 20 mA

(N.C.) (N.C.) Source

Page 4: ARCHITECT AND ENGINEER SPECIFICATIONS9 Petrochemical plants 9 Pharmaceutical industry 9 Power-generation facilities: Pumps, generator rooms and unmanned stations 9 Printing industry

s Industry, Inc. Building Technologies Division

Fire Safety 8 Fernwood Road Florham Park, NJ 07932 Tel: (973) 593-2600 FAX: (908) 547-6877 URL: www.SBT.Siemens.com/FIS

(SII‐FS) Printed in U.S.A.

 

Fire Safety 2 Kenview Boulevard Brampton, Ontario L6T 5E4 / Canada Tel: (905) 799-9937 FAX: (905) 799-9858

April 2011 Supersedes sheet dated 3/2011

(Rev. 1)

Notice: This marketing catalog sheet is not intended to be used for system design or installation purposes. For the most up-to-date information, refer to each product’s installation instructions.

(713)-395-1508Fax: (713) [email protected]

IndustrialZoneP.O. Box 667306Houston, Texas 77266United States