SECTION 08 62 00 PRISMATIC SKYLIGHTS Display hidden notes to specifier. (Don't know how? Click Here ) Copyright 2009 - 2020 ARCAT, Inc. - All rights reserved PART 1 GENERAL 1.1 SECTION INCLUDES A. Signature Series Prismatic Skylights. B. Double Hip Prismatic Skylights. C. Pyramid Prismatic Skylights. D. Multi-Lite Skylights. E. Curb Top Inserts. F. Daylighting Smoke Vents. G. LightFlex Daylighting Devices. 1.2 RELATED SECTIONS A. Section 07 50 00 - Membrane Roofing. B. Section 07 62 00 - Sheet Metal Flashing and Trim C. Section 07 91 23 - Backer Rods. D. Section 09 21 16.33 - Gypsum Board Area Separation Wall Assemblies. E. Section 09 51 23 - Acoustical Tile Ceilings. 1.3 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE): 1. ASHRAE 90.1 - Energy Standard for Buildings Except Low-Rise Residential Buildings. B. ASTM International (ASTM): 1. ASTM B221 - Standard Specification for Aluminum and Aluminum- 08 62 00 -1

Upload: others

Post on 29-Jun-2020

2 views

Category:

Documents


0 download

TRANSCRIPT

SECTION 08 62 00PRISMATIC SKYLIGHTS

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2009 - 2020 ARCAT, Inc. - All rights reserved

PART 1 GENERAL

1.1 SECTION INCLUDES

A. Signature Series Prismatic Skylights.

B. Double Hip Prismatic Skylights.

C. Pyramid Prismatic Skylights.

D. Multi-Lite Skylights.

E. Curb Top Inserts.

F. Daylighting Smoke Vents.

G. LightFlex Daylighting Devices.

1.2 RELATED SECTIONS

A. Section 07 50 00 - Membrane Roofing.

B. Section 07 62 00 - Sheet Metal Flashing and Trim

C. Section 07 91 23 - Backer Rods.

D. Section 09 21 16.33 - Gypsum Board Area Separation Wall Assemblies.

E. Section 09 51 23 - Acoustical Tile Ceilings.

1.3 REFERENCES

A. American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE):1. ASHRAE 90.1 - Energy Standard for Buildings Except Low-Rise Residential Buildings.

B. ASTM International (ASTM):1. ASTM B221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded

Bars, Rods, Wire, Profiles, and Tubes.2. ASTM D1003 - Standard Test Method for Haze and Luminous Transmittance of

Transparent Plastics,

C. Factory Mutual System (FM Global):1. FM Approval Guide, Chapter 18 - Building Materials.2. FM Standard 4430 - Test Criteria for Heat and Smoke Vents.3. FM Standard 4431 - Test Criteria for Skylights.

08 62 00 -1

D. National Fenestration Rating Council (NFRC):1. NFRC 100 - Procedure for Determining Fenestration Product U-Factors.2. NFRC 200 - Procedure for Determining Fenestration Product Solar Heat Gain

Coefficient and Visible Transmittance of Normal Incidence.

E. North American Fenestration Standard (NAFS):1. AAMA/WDMA/CSA/101/I.S.2/A440 - The Voluntary Performance Specification for

Windows, Skylights, and Glass Doors.

F. Occupational Health and Safety Administration (OSHA):1. OSHA 1926.502 - Fall protection systems criteria and practices.2. OSHA 1910 - Occupational Safety and Health Standards.

1.4 SUBMITTALS

A. Submit in accordance with Division 01 Section "Submittal Procedures".

B. Product Data: Submit manufacturers current published data on each product to be used including:1. Materials, dimensions, finishes and standard details.2. Compliance with design criteria and project conditions.3. Preparation instructions and recommendations.4. Storage and handling requirements.5. Installation instructions.

C. Verification Samples: For each finish product specified, two samples, minimum size 6 inches (150 mm) square representing actual product, color, and patterns.

D. Testing Reports: Submit Third Party Testing and Evaluation Reports as required by the local jurisdiction.

E. Shop Drawings: Include the following:1. Where design calculations are required, provide shop drawings and calculations

bearing the seal of a professional engineer licensed in the jurisdiction of the project.2. Plans, sections, elevations, flashing, connection, and termination details.3. Materials, thicknesses, fabrication and installation details including glazing types,

methods of attachment and provisions for thermal movement.4. Type of roofing system provided by others including insulation.5. Interface details including overall dimensions, thicknesses, and adjacent materials.6. Safety requirements.

F. Closeout Submittals: Maintenance instructions and Warranty.

1.5 QUALITY ASSURANCE

A. Qualifications:1. Manufacturer Qualifications: All primary products specified in this section will be

supplied by a single manufacturer with a minimum of ten years experience. Secondary products shall be acceptable to the primary manufacturer.

2. Installer Qualifications: All products shall be installed by a single installer with a minimum of five years demonstrated experience, with adequate equipment, skilled workers, and practical experience to meet the project schedule.

B. Skylights shall conform with authorities having jurisdiction and be designed to meet design criteria of the project location and the following:1. Skylights must be certified by NFRC.2. Tested and labeled in accordance to AAMA/WDMA/CSA/101/I.S.2/A440.

08 62 00 -2

3. Factory Mutual (FM) Approval Class Number 4430 or 4431 as applicable.4. Projects which fall under the jurisdiction of the Florida Building Code must have a

current Florida Building Code (FBC) Number to meet the High Velocity Hurricane Zone (HVHZ) requirements and are required for acceptance of Work specified in this section. Skylight systems must comply with the jurisdictional code body's submittal data and supporting drawings and documentation. Where the code body's acceptance criteria differ from these specifications regarding components and hardware, the code body's requirements shall govern.

5. Meet or exceed 200 pound (90 kg) Drop Tests.6. Skylights shall be designed and installed to carry a minimum 30 psf (1.44 kPa)

tributary roof load or greater per site.

C. Pre-Installation Meeting: Convene on the project site minimum one week before beginning work to:1. Verify project requirements and site logistics.2. Coordinate between trades.3. Assess integrity of the roofing system and building structure.4. Review manufacturers installation instructions and warranty requirements.

D. Mock-Up:1. Provide mock-up of each type of assembly including associated components,

accessories, and methods of adjoining construction.2. Finish areas designated by the Architect, minimum size: 3 x 3 feet (1 x 1 meter)

including all flashing, sealants, and finishes to be provided in the final installation.3. Do not proceed with remaining work until workmanship, color, and sheen are

approved by Architect.4. Refinish mock-up area as required to produce acceptable work.5. Accepted mock-up may remain as part of the completed work and will set the

standard of acceptance for remaining work.

1.6 DELIVERY, STORAGE AND HANDLING

A. Coordinate delivery schedule with the General Contractor and project schedule to minimize on site storage.

B. Store products in manufacturer's unopened packaging until ready for installation. Store materials in a dry area, protected from freezing, staining, contamination or damage.

C. Do not exceed structural loading with workers or installation materials.

1.7 PROJECT CONDITIONS

A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's limits.1. Review manufacturers installation instructions and warranty requirements.

1.8 WARRANTY

A. Provide manufacturer's standard warranty covering defective materials, workmanship and performance including the following Warranty Periods:1. Leak Free Warranty: 5 years.

PART 2 PRODUCTS

2.1 MANUFACTURERS

A. Acceptable Manufacturer: Sunoptics Prismatic Skylights , which is located at: 6201 27th St.;

08 62 00 -3

Sacramento, CA 95822; Toll Free Tel: 800-289-4700; Fax: 916-395-9204; Email:request info ([email protected]); Web:http://sunoptics.acuitybrands.com

B. Substitutions: Not permitted.

C. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

2.2 SIGNATURE SERIES PRISMATIC SKYLIGHTS

A. Signature Series Dome, Fixed Skylights: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:1. FM Approval No. 4431.2. High Velocity Hurricane Zone (HVHZ) Approved.3. AAMA/WDMA/CSA101/I.S.2/A440.4. Dimensions: ___________.5. Dimensions: As shown on the Drawings.6. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light Transmission (VLT).

b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

7. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.68

Visible Light Transmission (VLT).b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.64

Visible Light Transmission (VLT).c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

8. Glazing: Triple Glazed (TGZ).a. White/White/Clear: 0.26 Solar Heat Gain Coefficient (SHGC), 0.57 U-Value,

0.62 Visible Light Transmission (VLT).b. Lens Colors: LENSWHWHWH: White / White / White.c. Lens Colors: LENSCLCLCL: Clear / Clear / Clear.d. Lens Colors: LENSCLWHCL: Clear / White / Clear.e. Lens Colors: LENSWHCLWH: White / Clear / White.f. Lens Colors: LENSCLWHWH: Clear / White / White.g. Lens Colors: LENSWHCLCL: White / Clear / Clear.

9. Frame Type:a. 800MD: Standard Frame.b. 800SC: So-Cal Skylight.

10. Frame Finish:a. MI: Mill.b. WH: White.c. BZ: Bronze.d. CF: Custom Finish as selected by the Architect.

B. Signature Series Dome, Continuous Vented Skylights: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:1. Dimensions: ___________.2. Dimensions: As shown on the Drawings.3. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light

08 62 00 -4

Transmission (VLT).b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

4. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.68 Visible Light

Transmission (VLT).b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.64 Visible Light

Transmission (VLT)c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

5. Frame Type:a. 805SC 1BL: 1 Blade Continuous Vent.b. 805SC 2BL: 2 Blade Continuous Vent.c. 805SC 3BL: 3 Blade Continuous Vent.d. 805SC 4BL: 4 Blade Continuous Vent.e. 805SC 5BL: 5 Blade Continuous Vent.f. 805SC 6BL: 6 Blade Continuous Vent.g. 805SC 7BL: 7 Blade Continuous Vent.h. 805SC 8BL: 8 Blade Continuous Vent.i. 805SC 9BL: 9 Blade Continuous Vent.j. 805SC 10BL: 10 Blade Continuous Vent.

6. Provide insect screen on vented units.7. Frame Finish: MI: Mill.

2.3 DOUBLE HIP PRISMATIC SKYLIGHTS

A. Double Hip Fixed Skylights, Model 800MD: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:1. AAMA/WDMA/CSA101/I.S.2/A440.2. Dimensions: ___________.3. Dimensions: As shown on the Drawings.4. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light Transmission (VLT).

b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

5. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.68

Visible Light Transmission (VLT).b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.64

Visible Light Transmission (VLT).c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

6. Glazing: Triple Glazed (TGZ).a. White/White/Clear: 0.26 Solar Heat Gain Coefficient (SHGC), 0.57 U-Value,

0.62 Visible Light Transmission (VLT).b. Lens Colors: LENSWHWHWH: White / White / White.c. Lens Colors: LENSCLCLCL: Clear / Clear / Clear.d. Lens Colors: LENSCLWHCL: Clear / White / Clear.e. Lens Colors: LENSWHCLWH: White / Clear / White.f. Lens Colors: LENSCLWHWH: Clear / White / White.

08 62 00 -5

g. Lens Colors: LENSWHCLCL: White / Clear / Clear.7. Frame Type: 800MD: Standard Frame.8. Frame Finish:

a. MI: Mill.b. WH: White.c. BZ: Bronze.d. CF: Custom Finish as selected by the Architect.

B. Double Hip Manually Venting Skylights, Model 840B: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:1. Dimensions: ___________.2. Dimensions: As shown on the Drawings.3. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light Transmission (VLT).

b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

4. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.68

Visible Light Transmission (VLT).b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.64

Visible Light Transmission (VLT).c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

5. Glazing: Triple Glazed (TGZ).a. White/White/Clear: 0.26 Solar Heat Gain Coefficient (SHGC), 0.57 U-Value,

0.62 Visible Light Transmission (VLT).b. Lens Colors: LENSWHWHWH: White / White / White.c. Lens Colors: LENSCLCLCL: Clear / Clear / Clear.d. Lens Colors: LENSCLWHCL: Clear / White / Clear.e. Lens Colors: LENSWHCLWH: White / Clear / White.f. Lens Colors: LENSCLWHWH: Clear / White / White.g. Lens Colors: LENSWHCLCL: White / Clear / Clear.

6. Frame Type: 840B Manually Venting Frame.7. Frame Finish:

a. MI: Mill.b. WH: White.c. BZ: Bronze.d. CF: Custom Finish as selected by the Architect.

C. Double Hip Continuously Venting Skylights, Model 805SC: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:1. Dimensions: ___________.2. Dimensions: As shown on the Drawings.3. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light Transmission (VLT).

b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

4. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.68 Visible Light

Transmission (VLT).

08 62 00 -6

b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.64 Visible Light Transmission (VLT).

c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

5. Frame Type:a. 805SC 1BL: 1 Blade Continuous Vent.b. 805SC 2BL: 2 Blade Continuous Vent.c. 805SC 3BL: 3 Blade Continuous Vent.d. 805SC 4BL: 4 Blade Continuous Vent.e. 805SC 5BL: 5 Blade Continuous Vent.f. 805SC 6BL: 6 Blade Continuous Vent.g. 805SC 7BL: 7 Blade Continuous Vent.h. 805SC 8BL: 8 Blade Continuous Vent.i. 805SC 9BL: 9 Blade Continuous Vent.j. 805SC 10BL: 10 Blade Continuous Vent.

6. Provide insect screen on vented units.7. Frame Finish: MI: Mill.

2.4 PYRAMID PRISMATIC SKYLIGHTS

A. Pyramid Fixed Skylights, Model 800MD: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:1. AAMA/WDMA/CSA101/I.S.2/A440.2. Dimensions: ___________.3. Dimensions: As shown on the Drawings.4. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light Transmission (VLT).

b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

5. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.68

Visible Light Transmission (VLT).b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.64

Visible Light Transmission (VLT).c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

6. Glazing: Triple Glazed (TGZ).a. White/White/Clear: 0.26 Solar Heat Gain Coefficient (SHGC), 0.57 U-Value,

0.62 Visible Light Transmission (VLT).b. Lens Colors: LENSWHWHWH: White / White / White.c. Lens Colors: LENSCLCLCL: Clear / Clear / Clear.d. Lens Colors: LENSCLWHCL: Clear / White / Clear.e. Lens Colors: LENSWHCLWH: White / Clear / White.f. Lens Colors: LENSCLWHWH: Clear / White / White.g. Lens Colors: LENSWHCLCL: White / Clear / Clear.

7. Frame Type:a. 800MD: Standard Frame.

8. Frame Finish:a. MI: Mill.b. WH: White.

08 62 00 -7

c. BZ: Bronze.d. CF: Custom Finish as selected by the Architect.

B. Pyramid Manually Venting Skylights, Model 840B: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:1. Dimensions: ___________.2. Dimensions: As shown on the Drawings.3. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light Transmission (VLT).

b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

4. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.68

Visible Light Transmission (VLT).b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.64

Visible Light Transmission (VLT).c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

5. Glazing: Triple Glazed (TGZ).a. White/White/Clear: 0.26 Solar Heat Gain Coefficient (SHGC), 0.57 U-Value,

0.62 Visible Light Transmission (VLT).b. Lens Colors: LENSWHWHWH: White / White / White.c. Lens Colors: LENSCLCLCL: Clear / Clear / Clear.d. Lens Colors: LENSCLWHCL: Clear / White / Clear.e. Lens Colors: LENSWHCLWH: White / Clear / White.f. Lens Colors: LENSCLWHWH: Clear / White / White.g. Lens Colors: LENSWHCLCL: White / Clear / Clear.

6. Frame Type: 840B Manually Venting Frame.7. Frame Finish:

a. MI: Mill.b. WH: White.c. BZ: Bronze.d. CF: Custom Finish as selected by the Architect.

C. Pyramid Continuously Venting Skylights, Model 805SC: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:1. Dimensions: ___________.2. Dimensions: As shown on the Drawings.3. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light Transmission (VLT).

b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

4. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.68 Visible Light

Transmission (VLT).b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.64 Visible Light

Transmission (VLT).c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.

08 62 00 -8

f. Lens Colors: LENSCLCL: Clear / Clear.5. Frame Type:

a. 805SC 1BL: 1 Blade Continuous Vent.b. 805SC 2BL: 2 Blade Continuous Vent.c. 805SC 3BL: 3 Blade Continuous Vent.d. 805SC 4BL: 4 Blade Continuous Vent.e. 805SC 5BL: 5 Blade Continuous Vent.f. 805SC 6BL: 6 Blade Continuous Vent.g. 805SC 7BL: 7 Blade Continuous Vent.h. 805SC 8BL: 8 Blade Continuous Vent.i. 805SC 9BL: 9 Blade Continuous Vent.j. 805SC 10BL: 10 Blade Continuous Vent.

6. Provide insect screen on vented units.7. Frame Finish: MI: Mill.

2.5 MULTI-LIGHT PRISMATIC SKYLIGHTS

A. Double Hip Multi-Light Skylights, Model 800SB: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:1. AAMA/WDMA/CSA/101/I.S.2/A440.2. Dimensions: ___________.3. Dimensions: As shown on the Drawings.4. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light Transmission (VLT).

b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

5. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.68

Visible Light Transmission (VLT).b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.64

Visible Light Transmission (VLT).c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

6. Glazing: Triple Glazed (TGZ).a. White/White/Clear: 0.26 Solar Heat Gain Coefficient (SHGC), 0.57 U-Value,

0.62 Visible Light Transmission (VLT).b. Lens Colors: LENSWHWHWH: White / White / White.c. Lens Colors: LENSCLCLCL: Clear / Clear / Clear.d. Lens Colors: LENSCLWHCL: Clear / White / Clear.e. Lens Colors: LENSWHCLWH: White / Clear / White.f. Lens Colors: LENSCLWHWH: Clear / White / White.g. Lens Colors: LENSWHCLCL: White / Clear / Clear.

7. Frame Type: 800SB Standard Frame for MLT Multi-Lite.8. Frame Finish:

a. MI: Mill.b. WH: White.c. BZ: Bronze.d. CF: Custom Finish as selected by the Architect.

B. Pyramid Multi-Light Skylights, Model 800SB: Designed to provide the maximum amount of light transmission into the building while maintaining 100 percent light diffusion and meeting the following criteria:

08 62 00 -9

1. AAMA/WDMA/CSA/101/I.S.2/A440.2. Dimensions: ___________.3. Dimensions: As shown on the Drawings.4. Glazing: Single Glazed (SGZ).

a. White: 0.68 Solar Heat Gain Coefficient (SHGC), 0.74 Visible Light Transmission (VLT).

b. Lens Color: LENSWH: White.c. Lens Color: LENSCL: Clear.

5. Glazing: Double Glazed (DGZ).a. Clear/White: 0.42 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.68

Visible Light Transmission (VLT).b. White/White: 0.31 Solar Heat Gain Coefficient (SHGC), 0.70 U-Value, 0.64

Visible Light Transmission (VLT).c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

6. Glazing: Triple Glazed (TGZ).a. White/White/Clear: 0.26 Solar Heat Gain Coefficient (SHGC), 0.57 U-Value,

0.62 Visible Light Transmission (VLT).b. Lens Colors: LENSWHWHWH: White / White / White.c. Lens Colors: LENSCLCLCL: Clear / Clear / Clear.d. Lens Colors: LENSCLWHCL: Clear / White / Clear.e. Lens Colors: LENSWHCLWH: White / Clear / White.f. Lens Colors: LENSCLWHWH: Clear / White / White.g. Lens Colors: LENSWHCLCL: White / Clear / Clear.

7. Frame Type: 800SB Standard Frame for MLT Multi-Lite.8. Frame Finish:

a. MI: Mill.b. WH: White.c. BZ: Bronze.d. CF: Custom Finish as selected by the Architect.

2.6 CURB TOPPER SKYLIGHTS

A. Model 800MD Curb Mounted, Curb Topper Skylights: Structural and insulated wood and metal curbs to eliminate the need for interior structural reinforcement and equipped with Safety Security Grid to comply with OSHA 1926.502 and 1910 and the following:1. AAMA/WDMA/CSA/101/I.S.2/A440.2. OD Curb Dimensions: ___________.3. Dimensions: As shown on the Drawings.4. Double Glazing:

a. CT 1 White: 0.20 Solar Heat Gain Coefficient (SHGC), 0.36 U-Value, 0.60 Visible Light Transmission (VLT).

b. Double Glazing Lens Colors: LENSWHCL: White / Clear.c. Double Glazing Lens Colors: LENSCLWH: Clear / White.d. Double Glazing Lens Colors: LENSWHWH: White / White.e. Double Glazing Lens Colors: LENSCLCL: Clear / Clear.

5. Frame Type:a. 800MD: Standard Frame.b. 800MDE: Oversized Frame.

6. Frame Finish:a. MI: Mill.b. WH: White.c. BZ: Bronze.d. CF: Custom Finish as selected by the Architect.

08 62 00 -10

2.7 SMOKE VENTS

A. Model 870B, Daylighting Smoke Vents: Prefabricated, venting daylighting smoke vents with fusible link for use in industrial and commercial buildings where required by the local building code and the following:

B. Standards Compliance: Conform to standards set forth by authorities having jurisdiction and be designed to meet design criteria as specified and the following.1. Factory Mutual (FM) Approval Class Number 4431 as applicable.2. FM Approval No. 4430 with curb mounted design.3. UL 793 as applicable.4. UL Listed.

C. Performance and Design Requirements:1. Smoke Vents shall be designed and installed to carry a minimum 30 psf (1.44 kPa)

tributary roof load or greater per site.2. Energy Requirements: Glazing material shall have maximum light distribution per

Addendum D of ASHRAE 90.1, where the diffusing qualities have a minimum haze factor of 90 percent or greater. The combined inner/outer lens target values shall be as follows:a. Light Transmission: 60 to 68 percent.b. Diffusion / Haze Factor: 100 percent.

3. Hail Resistance Level: Class 1 as tested by certified engineering firm.4. Hail Resistance Level: Class 3 as tested by certified engineering firm.5. Snow Load Resistance Level: 10 pounds (44.5 N).6. Snow Load Resistance Level: 25 pounds (111.2 N).7. Snow Load Resistance Level: 30 pounds (133.4 N).8. Frame Dimensions: 51-1/4 x 63-1/4 inches (1302 x 1607 mm).9. Frame Dimensions: 51-1/4 x 75-1/4 inches (1302 x 1911 mm).10. Frame Dimensions: 51-1/4 x 87-1/4 inches (1302 x 2216 mm).11. Frame Dimensions: 52-1/4 x 100-1/4 inches (1327 x 2546 mm).12. Frame Dimensions: 63-1/4 x 87-1/4 inches (1607 x 2216 mm).13. Frame Dimensions: 63-1/4 x 99-1/4 inches (1607 x 2521 mm).14. Frame Dimensions: 63-5/8 x 75-5/8 inches (1616 x 1921 mm).15. Frame Dimensions (in / mm): ___________.16. Frame Dimensions: As shown on the Drawings.17. Frame: ASTM B221 alloy 6063-T5 extruded aluminum frame with extruded aluminum

dome retaining angle, Insulated thermal break, and integral condensate gutter and manufacturers standard weatherproofing accessories in the following profile:a. Signature series dome.b. Double hip.c. As indicated on the Drawings.

18. Glazing: Single glazed (SGZ).a. Acrylic: Visible Light Transmission (VLT): 0.74.b. Polycarbonate: Visible Light Transmission (VLT): 0.70.c. Lens Color: White. LENSWH.d. Lens Color: Clear. LENSCL.

19. Glazing: Double glazed (DGZ).a. Acrylic/Acrylic: U-Value: 0.74. Visible Light Transmission (VLT): 0.68.b. FM Approved Poly/Poly: U-Value: 0.74. Visible Light Transmission (VLT): 0.64.c. Lens Colors: LENSWHCL: White / Clear.d. Lens Colors: LENSCLWH: Clear / White.e. Lens Colors: LENSWHWH: White / White.f. Lens Colors: LENSCLCL: Clear / Clear.

20. Fusible Link: Mechanism includes gas shocks and exterior manual release cable for testing and the following temperature rating:

08 62 00 -11

a. Temperature Rating: Minimum 165 degrees F (74 degrees C).b. Temperature Rating: Minimum 212 degrees F (100 degrees C).c. Temperature Rating: Minimum 286 degrees F (141 degrees C).d. Temperature Rating: Minimum 360 degrees F (182 degrees C).e. Temperature Rating: Minimum 370 degrees F (188 degrees C).f. Temperature Rating: Minimum 386 degrees F (197 degrees C).

21. Operation: Remain tightly sealed against 30 lbs /sq ft (147 kg/sq m) internal uplift pressure until triggered by UL listed fusible link or opened manually from interior level. When released, doors shall be capable of opening against a 10 lbs/sq ft (49 kg/sq m) external snow or wind load and lock in open position.a. Opening Angle: Minimum 105 degrees.

22. Frame Finish: Mill (MI).23. Frame Finish: White (WH).24. Frame Finish: Bronze (BZ).25. Frame Finish: Custom Finish as selected by the Architect (CF).

2.8 LIGHTFLEX DAYLIGHTING DEVICES

A. Model SLFT, Tubular System, LightFlex Daylighting Devices: Daylighting devices bring natural light into suspended, finished ceiling applications that do not have direct access to the roof while meeting the following criteria:1. Standards Compliance:

a. FM Approved, with polycarbonate, with CC1.b. High Velocity Hurricane Zone (HVHZ) Approved, with CC1CC2 (Single or

Double Glazed).c. AAMA Certified.d. NFRC Certified.

2. Performance and Design Requirements:a. Conform with authorities having jurisdiction and meet design criteria of the

project location and the following criteria.1) Certified by NFRC.2) Tested and labeled per AAMAWDMACSA101I.S.2A440.3) Factory Mutual (FM) Approval Class Number 4430 or 4431 as applicable.4) Projects under jurisdiction of Florida Building Code must have a current

Florida Building Code (FBC) Number meeting High Velocity Hurricane Zone (HVHZ) requirements and are required for acceptance of Work specified in this section. Skylight must comply with the jurisdictional code body's submittal data and supporting drawings and documentation. Where the code body's acceptance criteria differs from these specifications regarding components and hardware, the code body's requirements shall govern.

5) Meet or exceed 200 lbs (90 kg) drop tests.6) Carry a minimum 30 psf (1.44 kPa) tributary roof load or greater per site.

b. Optic Sphere: Increases daylight conveyance.c. Interior Light Well:

1) Reflective MIRO-SILVER : 98 percent.2) Specular Quality: Greater than 99 percent.

d. Light Wells and Adjustable Elbows to bypass obstructions.1) Solar Heat Gain Coefficient (SHGC): 0.24.2) U-Value: 0.40.3) Visible Light Transmission (VLT): 0.40 to 0.68.

e. Frame: 6063-T5 extruded aluminum frame with mitered and welded corners, and integral condensation and weepage gutters to drain moisture to the outside.

f. Frame Finish: Mill (MI).g. Frame Finish: White (WH).

08 62 00 -12

h. Frame Finish: Bronze (BZ).i. Frame Finish: Custom Finish as selected by the Architect (CF).j. Glazing: Single Glazed (SGZ).k. Glazing: Double Glazed (DGZ).l. Skylight Lens Material: CC1CC2 Polycarbonate.m. Skylight Lens Material: CC1 Polycarbonate.n. Skylight Lens Material: CC2CL1 Acrylic Class 1.o. Skylight Lens Material: CC2CL3 Acrylic Class 3.p. Optic Sphere Lens Material: Acrylic prismatic.q. Roof Curb:

1) Insulated Curb, Aluminum: Aluminum with fiberglass insulation.2) Insulated Curb, Galvalume: Model AMBC-1, 18 ga. galvalume, full height

mitered and welded corners, cell caps supplied loose for field location, including fiberglass insulation, integral cricket water diverter.

3) Outside Dimensions: 25 by 25 inch (635 by 635 mm).4) Inside Dimensions: 22 by 22 inch (559 by 559 mm).5) Height: 8 inches (203 mm). 2108.6) Height: 14 inches (356 mm). 2114.7) Height: As shown on the Drawings.

r. Standard Kit includes the following:1) Signature Series skylight assembly.2) Optic sphere.3) Curb transition.4) Roof Curb Top Tube: 18 inches (457 mm).5) Curb with Curb Sealing Tape: 8 inch (203 mm).6) Light Well Tubes One and Two: 24 inches (610 mm) as applicable to

layout.7) Round to square transition.8) Ceiling diffuser (Diffuser lens style callout by selected style).9) Single blade louver.

s. Light Well Length: 4 foot (1219 mm) shaft (minimum length available). 4FT.t. Light Well Length: 6 foot (1829 mm) shaft. 6FT.u. Light Well Length: 8 foot (2438 mm) shaft. 8FT.v. Light Well Length: 10 foot (3048 mm) shaft. 10FT.w. Light Well Length: 12 foot (3658 mm) shaft. 12FT.x. Light Well Length: 14 foot (4267 mm) shaft. 14FT.y. Light Well Length: 16 foot (4877 mm) shaft. 16FT.z. Light Well Length: 18 foot (5486 mm) shaft. 18FT.aa. Diffuser Lens Style: TLED shadowbox lens assembly. TLSBOX.bb. Diffuser Lens Style: A19 lens assembly. TLA19.cc. Diffuser Lens Style: TLED microprism lens assembly. TLMICPRIS.dd. Diffuser Lens Style: Magellan white flat round lens.ee. Diffuser Lens Style: Magellan white prismatic round lens.ff. Diffuser Lens Style: ALLED troffer. ALLED.gg. Diffuser Lens Style: ACL ACLED troffer lens assembly. ACL.hh. Diffuser Lens Style: TLSATIN satin lens assembly. TLSATIN.ii. Provide with the Following Options:

1) Adjustable Elbows, One Set: 2 elbows, each 15-1/2 inch (394 mm) long. ELBOWS.

2) Adjustable Elbows, Two Sets: 4 elbows, each 15-1/2 inch (394 mm) long. ELBOWS2.

3) Suspension Wire Kit: SUSKIT.4) Security Bar: SBAR.5) Drywall Grid Adaptor: DWGA (available for Magellan Lens option only).

B. Model SLFO, Tubular System, LightFlex Open Ceiling Daylighting Devices: Daylighting

08 62 00 -13

devices bring natural light into suspended, finished ceiling applications that do not have direct access to the roof while meeting the following criteria:1. FM Approved, with polycarbonate, with CC1.2. High Velocity Hurricane Zone (HVHZ) Approved, with CC1CC2 (Single or Double

Glazed).3. AAMA Certified.4. NFRC Certified.5. Performance: Optic sphere increases daylight conveyance, 98 percent reflective

MIRO-SILVER interior light well with greater than 99 percent specular quality, adjustable elbows to bypass obstructions typically yield the following values:a. Solar Heat Gain Coefficient (SHGC): 0.24.b. U-Value: 0.40.c. Visible Light Transmission (VLT): 0.40 to 0.68.

6. Frame: 6063-T5 extruded aluminum frame with mitered and welded corners, and integral condensation and weepage gutters to drain moisture to the outside.

7. Frame Finish: MI: Mill.8. Frame Finish: WH. White.9. Frame Finish: BZ. Bronze.10. Frame Finish: CF. Custom Finish as selected by the Architect.11. Glazing: Single Glazed (SGZ).12. Glazing: Double Glazed (DGZ).13. Skylight Lens Material: CC1CC2 Polycarbonate.14. Skylight Lens Material: CC1 Polycarbonate.15. Skylight Lens Material: CC2CL1 Acrylic Class 1.16. Skylight Lens Material: CC2CL3 Acrylic Class 3.17. Optic Sphere Lens Material: Acrylic prismatic.18. Roof Curb:

a. Insulated Curb, Aluminum: Aluminum with fiberglass insulation.b. Insulated Curb, Galvalume: Model AMBC-1, 18 ga. galvalume, full height

mitered and welded corners, cell caps supplied loose for field location, including fiberglass insulation, integral cricket water diverter.

c. Outside Dimensions: 25 by 25 inch (635 by 635 mm).d. Inside Dimensions: 22 by 22 inch (559 by 559 mm).e. Curb Height: 8 inch (203 mm): 2108.f. Curb Height: 14 inch (356 mm): 2114.g. Curb Height: As shown on the Drawings.

19. Standard Kit includes the following:a. Signature Series skylight assembly.b. Optic sphere.c. Curb transition.d. 18 inches (457 mm) roof curb top tube.e. 8 inch (203 mm) Curb with curb sealing tape.f. 24 inches (610 mm) light well tubes (Length callout by layout).g. Diffuser (Diffuser lens style callout by selected style).

20. Light Well Length: 4 foot (1219 mm) shaft (minimum length available): 4FT21. Light Well Length: 6 foot (1829 mm) shaft: 6FT.22. Light Well Length: 8 foot (2438 mm) shaft: 8FT.23. Diffuser Lens Style: Clear Prismatic Round: CLPRIS.24. Diffuser Lens Style: White Prismatic Round: WHPRIS.25. Diffuser Lens Style: White Frosted Round: WHFRST.26. External Guard: ESFP.

C. Model 800SLF, SquareSystem, LightFlex Daylighting Devices: Daylighting devices bring natural light into suspended, finished ceiling applications that do not have direct access to the roof while meeting the following criteria:1. AAMA Certified.

08 62 00 -14

2. NFRC Certified.3. Performance: Optic sphere increases daylight conveyance, 98 percent reflective

MIRO-SILVER interior light well with greater than 99 percent specular quality, adjustable elbows to bypass obstructions typically yield the following values:a. Solar Heat Gain Coefficient (SHGC): 0.24.b. U-Value: 0.40.c. Visible Light Transmission (VLT): 0.40 to 0.68.

4. Frame: 6063-T5 extruded aluminum frame with mitered and welded corners, and integral condensation and weepage gutters to drain moisture to the outside.

5. Unit Size: 2 by 4 foot (609 by 1218 mm).6. Unit Size: 4 by 4 foot (1218 by 1218 mm).7. Unit Size: As shown on the Drawings.8. Roof Curb: As recommended by the manufacturer.9. Skylight Lens Material: CC1CC2 Polycarbonate / Acrylic.10. Skylight Lens Material: CC1 Polycarbonate.11. Skylight Lens Material: CC2CL1 Acrylic Class 1.12. Skylight Lens Material: CC2CL3 Acrylic Class 3.13. Glazing: Single Glazed (SGZ).14. Glazing: Double Glazed (DGZ).15. Skylight Lens Colors: LENSWH - White.16. Skylight Lens Colors: LENSCL: Clear.17. Skylight Lens Colors: LENSWHCL - White / Clear.18. Skylight Lens Colors: LENSCLWH: Clear / White.19. Skylight Lens Colors: LENSWHWH: White / White.20. Skylight Lens Colors: LENSCLCL: Clear / Clear.21. Diffuser Lens Material: Acrylic.22. Diffuser Lens Material: Polycarbonate.23. Diffuser Lens Color: White prismatic.24. Diffuser Lens Color: Clear prismatic.25. Diffuser Lens Style: ACLED Troffer lens assembly.26. Diffuser Lens Style: Acrylic.27. Diffuser Lens Style: TLED Shadowbox lens assembly.28. Diffuser Lens Style: A19 lens assembly.29. Diffuser Lens Style: TLED Microprism lens assembly.30. Diffuser Lens Style: TLED Satin lens assembly.31. Diffuser Lens Style: TLED Troffer with prismatic lens flat assembly.32. Shaft Length: 2 foot (609 mm).33. Shaft Length: 3 foot (914 mm).34. Shaft Length: 4 foot (1219 mm).35. Shaft Length: 5 foot (1524 mm).36. Shaft Length: 6 foot (1829 mm).37. Shaft Length: 7 foot (2133 mm).38. Shaft Length: 8 foot (2438 mm).39. Shaft Length: 9 foot (2743 mm).40. Shaft Length: 10 foot (3048 mm).41. Shaft Length: 11 foot (3352 mm).42. Shaft Length: 12 foot (3658 mm).43. Shaft Length: 13 foot (3962 mm).44. Shaft Length: 14 foot (4267 mm).45. Shaft Length: 15 foot (4572 mm).46. Shaft Length: 16 foot (4877 mm).47. Frame Finish:

a. MI: Mill.b. WH: White.c. BZ: Bronze.d. CF: Custom Finish as selected by the Architect.

08 62 00 -15

48. Provide with the following options:a. Factory Mutual Approved (FM).b. High Velocity Hurricane Zone (HVHZ).c. Insulated thermal break.d. No insulated thermal break.e. Weather sweep.f. No weather sweep.g. No installation screw.h. 24 by 24 inch (609 by 609 mm) ceiling grid pattern.i. LightFlex louver.

D. Model SLFTL, Tubular System featuring Tunable White LED, LightFlex Daylighting Devices: Daylighting devices bring natural light into suspended, finished ceiling applications that do not have direct access to the roof while meeting the following criteria:1. Standards Compliance:

a. FM Approved, with polycarbonate, with CC1.b. High Velocity Hurricane Zone (HVHZ) Approved, with CC1CC2 (Single or

Double Glazed).c. AAMA Certified.d. NFRC Certified.

2. Performance and Design Requirements:a. Conform with authorities having jurisdiction and meet design criteria of the

project location and the following criteria:1) Certified by NFRC.2) Tested and labeled in accordance to AAMAWDMACSA101I.S.2A440.3) Factory Mutual (FM) Approval Class Number 4430 or 4431 as applicable.4) Projects under the jurisdiction of Florida Building Code must have a

current Florida Building Code (FBC) Number to meet the High Velocity Hurricane Zone (HVHZ) requirements and are required for acceptance of Work specified in this section. Skylight must comply with the jurisdictional code body's submittal data and supporting drawings and documentation. Where the code body's acceptance criteria differs from these specifications regarding components and hardware, the code body's requirements shall govern.

5) Meet or exceed 200 pound (90 kg) Drop Tests.6) Carry a minimum 30 psf (1.44 kPa) tributary roof load or greater per site.

b. LED Lighting and Controls: Conform with authorities having jurisdiction. Meet design criteria of the project and the following:1) DesignLights Consortium Networked Lighting Control System

Specification V2.0.2) Components and the manufacturing facility where product was

manufactured must be RoHS compliant.3) Where required for egress and/or emergency lighting control the devices,

relays and fixtures shall conform to UL 924.4) Integration with Building Management Systems (BMS) and Heating,

Ventilation and Air Conditioning (HVAC) equipment.c. Optic Sphere: Increases daylight conveyance.d. Interior Light Well:

1) Reflective MIRO-SILVER : 98 percent.2) Specular Quality: Greater than 99 percent.

e. Light Wells and Adjustable Elbows to bypass obstructions.1) Solar Heat Gain Coefficient (SHGC): 0.24.2) U-Value: 0.40.3) Visible Light Transmission (VLT): 0.40 to 0.68.

f. Frame: 6063-T5 extruded aluminum frame with mitered and welded corners, and integral condensation and weepage gutters to drain moisture to the

08 62 00 -16

outside.g. Frame Finish: Mill (MI).h. Frame Finish: White (WH).i. Frame Finish: Bronze (BZ).j. Frame Finish: Custom Finish as selected by the Architect (CF).k. Glazing: Single Glazed (SGZ).l. Glazing: Double Glazed (DGZ).m. Skylight Lens Material: CC1CC2 Polycarbonate.n. Skylight Lens Material: CC1 Polycarbonate.o. Skylight Lens Material: CC2CL1 Acrylic Class 1.p. Skylight Lens Material: CC2CL3 Acrylic Class 3.q. Optic Sphere Lens Material: Acrylic prismatic.r. Roof Curb:

1) Insulated Curb, Aluminum: Aluminum with fiberglass insulation.2) Insulated Curb, Galvalume: Model AMBC-1, 18 ga. galvalume, full height

mitered and welded corners, cell caps supplied loose for field location, including fiberglass insulation, integral cricket water diverter.

3) Outside Dimensions: 25 by 25 inch (635 by 635 mm).4) Inside Dimensions: 22 by 22 inch (559 by 559 mm).5) Height: 8 inches (203 mm). 2108.6) Height: 14 inches (356 mm). 2114.7) Height: As shown on the Drawings.

s. Standard Kit includes the following:1) Signature Series skylight assembly.2) Optic sphere.3) Curb transition.4) Roof Curb Top Tube: 18 inches (457 mm).5) Curb with Curb Sealing Tape: 8 inch (203 mm).6) Light Well Tubes One and Two: 24 inches (610 mm) as applicable to

layout.7) Round to square transition.8) Ceiling diffuser with lens as applicable to style.9) Single blade louver.10) Open Loop sensor.11) CAT 5 cable for sensor.

t. Light Well Length: 4 foot (1219 mm) shaft (minimum length available). 4FT.u. Light Well Length: 6 foot (1829 mm) shaft. 6FT.v. Light Well Length: 8 foot (2438 mm) shaft. 8FT.w. Light Well Length: 10 foot (3048 mm) shaft. 10FT.x. Light Well Length: 12 foot (3658 mm) shaft. 12FT.y. Light Well Length: 14 foot (4267 mm) shaft. 14FT.z. Light Well Length: 16 foot (4877 mm) shaft. 16FT.aa. Light Well Length: 18 foot (5486 mm) shaft. 18FT.bb. Diffuser Lens Style: TLED shadowbox lens assembly. TLSBOX.cc. Diffuser Lens Style: A19 lens assembly. TLA19.dd. Diffuser Lens Style: TLED microprism lens assembly. TLMICPRIS.ee. Diffuser Lens Style: Magellan white flat round lens.ff. Diffuser Lens Style: Magellan white prismatic round lens.gg. Diffuser Lens Style: ALLED troffer. ALLED.hh. Diffuser Lens Style: ACL ACLED troffer lens assembly. ACL.ii. Diffuser Lens Style: TLSATIN satin lens assembly. TLSATIN.jj. Provide with the Following Options:

1) Adjustable Elbows, One Set: 2 elbows, each 15-1/2 inch (394 mm) long. ELBOWS.

2) Adjustable Elbows, Two Sets: 4 elbows, each 15-1/2 inch (394 mm) long. ELBOWS2.

08 62 00 -17

3) Suspension Wire Kit: SUSKIT.4) Security Bar: SBAR.5) Drywall Grid Adaptor: DWGA (available for Magellan Lens option only).6) Occupancy Sensor (PIR): passive infrared occupancy sensor.7) Occupancy Sensor (PDT): Dual technology occupancy sensor PIR and

microphonics.8) Battery Pack, Typical Lighting: 10 W integral battery back-up.9) Battery Pack, Emergency Lighting: E10 W integral battery back-up10) Accessories:

a) Louver Control.b) On/Off, Intensity Adjustment and CCT Control.c) Small Motion 360 degree, ceiling.d) Large Motion 360 degree, ceiling.

E. LED Lighting:1. Model SLFTL, Tunable LED Device: Provide tunable-white LEDs to provide lighting

during the early morning or evening hours when daylight is not available while meeting project criteria.

2. Model SLFTL, Tunable LED Device Controls: Provide integrated sensor that works in conjunction with the lighting controls system such that the LEDs will supplement daylight coming through the tubular daylighting system.

3. Lighting Control System:a. The lighting control system shall provide time-based, sensor-based (both

occupancy and daylight), and manual lighting control.b. The system shall be capable of turning lighting loads on/off as well as dimming

lights (if lighting load is capable of being dimmed). Specific dimmers will be capable of "dimming lights to off".

c. System devices shall be networked together, enabling digital communication between devices, and shall be individually addressed.

d. The system architecture shall be capable of enabling stand-alone groups (rooms) of devices to function in some default capacity, even if network connectivity to the greater system is lost.

e. The system architecture shall facilitate remote operation via a computer connection.

f. The system shall not require any centrally hardwired switching equipment.g. The system shall be capable of wireless, wired, or hybrid wireless/wired

architectures.4. Fixtures:

a. Light Source: Tunable white LED.1) LED Output (LM): 3000 to 4000 delivered lumens. Reference LightFlex

LED data sheet for detailed performance data.2) Dynamic Feature (TUWH): Tunable.3) Dynamic Range (Default): RHYR (Rhythm range) (2700 K to 6500 K).4) Dynamic Range: PROR (Productivity range) (3000 K to 5000 K).5) LED Color Rendering (Default) CRI (80 CRI): 80 plus.6) LED Color Rendering CRI (90 CRI): 90 plus.7) Minimum Dimming Level: Dark. Less than 1 percent dimming.8) Control Input: nLight Enabled.9) Voltage: 120 V.

F. Model SLFOL, Tubular System, LightFlex Daylighting Devices: Daylighting devices bring natural light into suspended, finished ceiling applications that do not have direct access to the roof while meeting the following criteria:1. FM Approved, with polycarbonate, with CC1.2. High Velocity Hurricane Zone (HVHZ) Approved, with CC1CC2 (Single or Double

Glazed).

08 62 00 -18

3. AAMA Certified.4. NFRC Certified.5. Performance: Optic sphere increases daylight conveyance, 98 percent reflective

MIRO-SILVER interior light well with greater than 99 percent specular quality, adjustable elbows to bypass obstructions typically yield the following values:a. Solar Heat Gain Coefficient (SHGC): 0.24.b. U-Value: 0.40.c. Visible Light Transmission (VLT): 0.40 to 0.68.

6. Frame: 6063-T5 extruded aluminum frame with mitered and welded corners, and integral condensation and weepage gutters to drain moisture to the outside.

7. Frame Finish: MI: Mill.8. Frame Finish: WH. White.9. Frame Finish: BZ. Bronze.10. Frame Finish: CF. Custom Finish as selected by the Architect.11. Glazing: Single Glazed (SGZ).12. Glazing: Double Glazed (DGZ).13. Skylight Lens Material: CC1CC2 Polycarbonate.14. Skylight Lens Material: CC1 Polycarbonate.15. Skylight Lens Material: CC2CL1 Acrylic Class 1.16. Skylight Lens Material: CC2CL3 Acrylic Class 3.17. Optic Sphere Lens Material: Acrylic prismatic.18. Roof Curb:

a. Insulated Curb, Aluminum: Aluminum with fiberglass insulation.b. Insulated Curb, Galvalume: Model AMBC-1, 18 ga. galvalume, full height

mitered and welded corners, cell caps supplied loose for field location, including fiberglass insulation, integral cricket water diverter.

c. Outside Dimensions: 25 by 25 inch (635 by 635 mm).d. Inside Dimensions: 22 by 22 inch (559 by 559 mm).e. Curb Height: 8 inch (203 mm): 2108.f. Curb Height: 14 inch (356 mm): 2114.g. Curb Height: As shown on the Drawings.

19. Standard Kit includes the following:a. Signature Series skylight assembly.b. Optic sphere.c. Curb transition.d. Roof curb top tube. 18 inches (457 mm)e. Curb with curb sealing tape. 8 inch (203 mm)f. Light well tubes (Length callout by layout). 24 inches (610 mm)g. Diffuser (Diffuser lens style callout by selected style).h. Single blade louver.i. Open Loop Sensorj. Remote Driver Enclosurek. CAT 5 cable for Sensor

20. Light Well Length: 4 foot (1219 mm) shaft (minimum length available): 4FT.21. Light Well Length: 6 foot (1829 mm) shaft: 6FT.22. Light Well Length: 8 foot (2438 mm) shaft: 8FT.23. Diffuser Lens Style: Clear Prismatic Round: CLPRIS.24. Diffuser Lens Style: White Prismatic Round: WHPRIS.25. Diffuser Lens Style: White Frosted Round: WHFRST.26. Provide with the Following Options:

a. Suspension Wire Kit: SUSKIT.b. External Skylight Fall Protection: ESFP.c. Occupancy Sensor (PIR): passive infrared occupancy sensor.d. Occupancy Sensor (PDT): Dual technology occupancy sensor PIR and

microphonics.e. Battery Pack: 10W integral battery back-up: E10W (For Emergency Lighting).

08 62 00 -19

2.9 LED LIGHTING

A. Model SLFOL, Tunable LED Device: Provide tunable-white LEDs to provide lighting during the early morning or evening hours when daylight is not available while meeting project criteria.

B. Model SLFOL, Tunable LED Device Controls: Provide integrated sensor that works in conjunction with the lighting controls system such that the LEDs will supplement daylight coming through the tubular daylighting system.

C. Lighting Control System:1. The lighting control system shall provide time-based, sensor-based (both occupancy

and daylight), and manual lighting control.2. The system shall be capable of turning lighting loads on/off as well as dimming lights

(if lighting load is capable of being dimmed). Specific dimmers will be capable of "dimming lights to off".

3. System devices shall be networked together, enabling digital communication between devices, and shall be individually addressed.

4. The system architecture shall be capable of enabling stand-alone groups (rooms) of devices to function in some default capacity, even if network connectivity to the greater system is lost.

5. The system architecture shall facilitate remote operation via a computer connection.6. The system shall not require any centrally hardwired switching equipment.7. The system shall be capable of wireless, wired, or hybrid wireless/wired architectures.

D. Fixtures:1. Light Source: Tunable white LED.

a. LED Output (LM): 3000 to 4000 delivered lumens. Reference LightFlex Open Ceiling LED data sheet for detailed performance data.

b. Dynamic Feature (TUWH): Tunable.c. Dynamic Range: PROR (Productivity range) (3000K to 5000K).d. Dynamic Range (Default): RHYR (Rhythm Range) (2700K to 6500K).e. LED Color Rendering (Default) CRI (80 CRI): 80-Plus.f. LED Color Rendering CRI (90CRI): 90-Plus.g. Minimum Dimming Level: Dark. Less than 1 percebnt dimming.h. Control Input: Light Enabled.i. Voltage: 120 V.

2.10 ACCESSORIES

A. Installation Screws: No. 12 x 1-1/2 inch (38 mm) 300 series stainless steel screws with neoprene stainless steel bonded washers in quantity recommended by the manufacturer.

B. Metal Building Curb, Model AMBC-1: Insulated metal building curb, full height mitered and welded corners, cell caps supplied loose for field location, including fiberglass insulation, integral cricket water diverter.1. Material: 18 ga. galvalume construction.2. Material: Aluminum construction.3. Material: Heavier gauge steel.4. Finish: ________.5. Finish: Painted. Colors as determined by the Architect.6. Finish: As shown on the Drawings or as determined by the Architect.7. Perforated noise control baffles.8. Installed cell caps.

C. Galvanized Insulated Curb, Model ARC-3: Fiberglass insulation and pressure treated wood nailer for mounting skylight. OSHA 1910 and 1926.502 compliant with wire mesh and welded

08 62 00 -20

security guard.1. Material: Galvanized steel. 14 ga. with white painted interior.2. Material: Galvanized steel. 18 ga. with white painted interior.3. Security Bars: round.

D. Galvanized Insulated Curb, Model ARC-6: Pressure treated wood nailer for mounting skylight. OSHA 1910 and 1926.502 compliant with wire mesh and welded security guard.1. Material: Galvanized steel. 14 ga. with white painted interior.2. Material: Galvanized steel. 18 ga. with white painted interior.3. Security Bars: round.

E. Wood Curb: 2X Douglas fir lumber with corners joined using 18 gauge galvanized strap, interior polyester white liner, and pre-mounted angle clips.

F. Safety Security Guard, Model CLPOG: Clip on guard of galvanized cold rolled steel, to meet OSHA 1910.23 requirements.

G. Grid Guard: Drop in steel guard provided with screws, SSG welded to Z-frame on all four sides. Comply with manufacturers installation details.

2.11 FABRlCATlON

A. Fabricated frames from 6063 T6 aluminum with integral condensation and weeping gutters to drain interior moisture to the outside.

B. Skylights shall be factory assembled and glazed ready for installation, pre-drilled for anchorage to roof curbs.

C. Fabricate skylights weather tight and free of visual distortions and defects.

D. Multi-glazed units include Insulated Thermal Break (ITBR), Curb Seal Tape, Weather Sweep (WSW) and screws.

E. Protect exterior drip counter flashing and drainage ports from weather and air-borne debris.

F. Miter and full penetration weld all corners of curb and retaining frames with glazing separated from the skylight frame with a silicone seal along the full perimeter of the retaining frame.

PART 3 EXECUTION

3.1 EXAMINATION

A. Verification of Conditions:1. Confirm work by others is installed per the project requirements. Do not cover work by

others prior to inspection or acceptance.2. Do not begin installation until substrates have been properly prepared.3. If substrate preparation is the responsibility of another installer, notify Architect of

unsatisfactory preparation before proceeding.

B. Do not proceed until unacceptable conditions are corrected.

3.2 PREPARATION

A. Clean surfaces thoroughly prior to installation.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project conditions.

08 62 00 -21

3.3 INSTALLATION

A. Install in accordance with manufacturer's instructions and in proper relationship with adjacent construction. Test for leaks as recommended by manufacturer.

3.4 CLEANING

A. Remove all debris from the project site in accordance with the Owner's construction waste management requirements.

3.5 PROTECTION

A. Protect installed products until completion of project.

B. Touch-up, repair or replace damaged products before Substantial Completion.

END OF SECTION

08 62 00 -22