REQUIREMENTS FOR ARC FLASH ASSESSMENTS FOR COMPLIANCE WITH NFPA 70E

Arc Flash Solutions

Team Fishel Professional Services GroupRichmond, Virginia

1

IntroductionAccording to the National Fire Protection Association (NFPA), an Arc Flash hazard is a dangerous condition associated with the possible release of energy caused by an electric arc

Between Five (5) to Ten (10) Arc Flash explosions occur in electrical equipment every day in the United States

What is an Arc Flash / Arc Blast?

2

Arc FlashNFPA 70E definitionsK.3 Arc Flash When an electric current passes through air between ungrounded conductors or between ungrounded conductors and grounded conductors, the temperatures can reach 35,000F, this is four times the surface temperature of the sun. Each year more than 2000 people are admitted to burn centers with severe Arc Flash burns.

K.4 Arc-Blast The tremendous temperatures of the arc cause the explosive expansion of both the surrounding air and the metal in the arc path. For example, copper expands by a factor of 67,000 times when it turns from a solid to a vapor. The danger associated with this expansion is one of high pressures, sound, and shrapnel.

Arc Blast

3

What causes Arc Flash?

Dust and impurities - Dust and impurities on insulating surfaces can provide a path for current, allowing it to flashover and create an arc discharge across the surface. Corrosion - Corrosion of equipment creates impurities on insulating surfaces. Condensation - Water vapor can drip causing tracking on the surface of insulating materials. This can create a flashover to ground. Spark discharge - Accidental contact; dropping tools Failure of insulating materials Exposed surfaces that can provide a path for current. Improper work procedures Untrained/uncertified technicians and improper PPE usage.

4

Governing AgenciesOSHA 29 CFR 1910 SUBPART S and 1926 SUBPART KElectrical

NFPA 70 National Electric Code

NFPA 70-E Standard for Electrical Safety in the Workplace

IEEE Std 1584Guide for Performing Arc Flash Hazard Calculations

5

Paragraph (e) of 1910.303 Requires employers to mark electrical equipment with descriptive markings, including the equipment's voltage, current, wattage, or other ratings as necessary. OSHA states that this information, along with the training requirements for qualified persons, will provide employees the necessary information to protect themselves from Arc Flash hazards.

110.16 Flash Protection. Electrical equipment, such as switchboards, panel boards, industrial control panels, meter socket enclosures, and motor control centers, that are in other than dwelling occupancies, and are likely to require examination, adjustment, servicing, or maintenance while energized shall be field marked to warn qualified persons of potential electric Arc Flash hazards. The marking shall be located so as to be clearly visible to qualified persons before examination, adjustment, servicing, or maintenance of the equipment.

Show Video Richard Fairfax Deputy Assistant Secretary6

NFPA 70-E Arc Flash Analysis130.5 Arc Flash Hazard Analysis. An Arc Flash hazard analysis shall determine the Arc Flash boundary, the incident energy at the working distance, and the personal protective equipment that people within the Arc Flash boundary shall use.

The Arc Flash hazard analysis shall be updated when a major modification or renovation takes place. It shall be reviewed periodically, Not To Exceed 5 Years, to account for changes in the electrical distribution system that could affect the results of the Arc Flash hazard analysis.

7

Arc Flash Protection BoundaryThe Flash Protection Boundary (FPB) is defined as the distance at which a worker is exposed to 1.2 calories/cm2 of incident energy. This is the distance at which PPE must be worn to prevent 2nd-degree or greater burns in the event of an Arc Flash. Any persons crossing the FPB must wear appropriate Arc Rated PPE. Arc Flash Boundary

8

NFPA 70-E Arc Flash Labels

The Nation Fire Protection Association REQUIRES that all electrical equipment be properly labeled130.3 Arc Flash Hazard Analysis States:Equipment shall be field marked with a label containing the available incident energy or required level of PPE

9

NFPA 70-E Arc Flash Warning Label

10

NFPA 70-E Arc Flash Danger Label

11

The Qualified Person

Anyone who has a need to work within the Arc Flash boundaries dictated by the analysis must either be certified as a Qualified Person or accompanied by a Qualified Person, depending on the equipment and distance they are working from that equipment.

NFPA 70-E defines a Qualified Person as follows:One who has skills and knowledge related to the construction and operation of the electrical equipment and installations and has received safety training to recognize and avoid the hazards involved.

12

Limited Approach BoundaryThe Limited Approach Boundary is the distance from the live part to which unqualified persons may approach unaccompanied. To cross the Limited Approach Boundary, unqualified persons must be accompanied by a qualified worker wearing the appropriate Voltage Rated PPE and trained on the task to be performed.

Restricted Approach Boundary The Restricted Approach Boundary may only be crossed by qualified workers with appropriate Voltage Rated PPE and training on the task to be performed. In addition, the worker must have an approved work permit and written plan for the task. The plan should include shock-prevention procedures designed to keep all portions of the worker's body from crossing the Prohibited Approach Boundary at any time.

Shock Hazard BoundariesDependent on Voltage Only

13

By Providing the Best: How Can Team FishelBe your Solution?

Comprehensive & Complete Arc Flash AnalysisArc Flash Compliance LabelingClassroom and Hands-on Workplace Safety TrainingCertification & Re-Certification for Qualified Person(s)Proper Usage of Rated PPE and Purchasing Recommendations

14

Professional Service Solutions

Arc Flash Safety Services include: Data collection of all equipment to identify fault currents, overcurrent protection devices and other necessary information Analysis and calculations to provide detailed information on the Arc Flash hazard and shock hazard for each area of potential exposure to conductors or circuit components. The Analysis and calculations reporting will include the following:Fault Current StudiesEquipment EvaluationArc Flash StudiesElectrical EquipmentTime Current Curves

15

Professional Services Solutions (cont.)

Proper labeling of all panels for compliance with National Fire Protection Association (NFPA) 70E Training to mitigate electrical hazards and increase safety measures Ongoing services for training new personnel, meeting annual training requirements, and providing required analysis updates after deploying new equipment or modifying existing processes.

Recommendations (when applicable) to mitigate the risk of electrical hazards through proper electrical design

16

Arc Flash SolutionsValue Added Our Arc Flash safety solutions for all 3-phase power distribution in building systems will help improve safety in the workplace and support your safety culture to mitigate risk, improve productivity and increase operational efficiency by:

Reducing time to compliance, improving safety in the workplace for employees

Ensuring conformity with relevant hazardous energy standards, limiting exposure to regulatory fines for your business

Furnishing up-to-date electrical system documentation, including one-line power diagrams that assist with efficient workplace upgrades and maintenance

Create an electrical system study to determine the present degree of Arc Flash hazards and apply associated equipment labeling

Delivering short circuit analysis that can identify over-cycled equipment, enhancing operational reliability

Learn how to maintain electrical distribution system components

17

Class Environment TrainingAFT 002 Training Classes The purpose of this session is to provide training on NFPA 70E Article 130 to personnel who are required to function near or interface with electrical equipment, but will not are not qualified to be within the approach boundaries specified in NFPA 70E.

AFT 004 Training Classes The purpose of this session is to provide training on NFPA 70E Article 130 to personnel who are required to examine, adjust, service, or maintain electrical equipment while it is energized and meet the standards required for qualified personnel as defined in NFPA 70E

18

For More Information

Please visit our websitewww.teamfishel.com/arcflashsolutionsOr contact our Professional Services Group in Richmond, VABrian Smith, Division Managerbysmith@teamfishel.comandEdward Khalil, PE ekhalil@teamfishel.com