Buffer Tanks For Chilled & Heating Water Circuits
PAPP
CKAKK GEE SOLUTIONSFOR
THEHVAVVCMARRKET
AQUAZONE
More storage... ...when you need it.
Not only specify... ...an Aquazone...insist on it.
Phone 02 97482022 Email [email protected]
Aquazone Buffer Tanks for Chilled Water.An Aquazone buffer tank is often incorporated into a chilled water system that has insufficient water volume throughout the piping network in relation to the chiller capacity. By adding a buffer tank to the system, extra volume is created which provides additional “buffer” capacity and eliminates the problems of excessive compressor cycling, poor temperature control and erratic system operation.
In some instances when a large building is undergoing refurbishments or extensions, the capital expenditure of a larger chiller can be deferred, by installing large buffer tanks and utilizing the existing chiller. These tanks are insulated so that the stored water maintains it chilled temperature. This allows the chiller to work extra hours in the day, thus providing extra chilled water which is stored and then used throughout the next day when required.
With the addition of sparge pipes and baffles the Aquazone tanks can be effective Thermal Energy Storage Tanks.As a storage system the Aquazone tank allows the chillerto operate at off-peak times of the day providing the Facility Manager with a possible effective strategy for energycost reductions.
Aquazone tanks can also be utilized in heating water systems. Refer to our sales department for further information.
Why Use Aquazone Buffer Tanks?• All Aquazone tanks are insulated to the BCA Section J requirements.• All Aquazone tanks have Zero Ozone Depletion Potential• They are aesthetically pleasing in any plant room, as they come standard with Stainless Steel cladding.• Due to the Stainless Steel cladding there is no need to paint them, thus providing a low maintenance exterior.• All Aquazone tanks have generously sized Inspection Openings.• Are suitable for indoor and outdoor situations.• Designed to AS 1210 Unfired Pressure Vessels, Hazard level E.• Low profile to facilitate installation in low roof plant-rooms.• Available in various materials and pressure ratings.• Standard designs and custom-made designs.
2
Aquazone tanks can also be utilizeRefer to our sales department for fu
Why Use Aquazone Buffer
AQUAZONE
Phone 02 97482022 Email [email protected]
Configuration & OrientationAquazone tanks are available as a standard design in the Vertical orientation. Sizes 4,000 litres and larger are also available in the horizontal orientation. Each orientation is available with various inlet/outlet configurations depending on the quality and position of the inlets and outlets.
3
2x12 G
1x RV
DIN16#150INLET
DIN16#150OUTLET
DRAIN (DR)
Vent (V)
OH
ØD
HIf you need a custom
made solution...Masterflow can help
OUTLET ON TOPOR BOTTOM
DEPENDING ON PURPOSEIN-LET
RV G V
DR
L
OL
OHD
PLAN VIEW
FF
3005001000150020003000400050006000750010000
2020252525323240404050
4040404025252525252525
DIN16 x 50DIN16 x 80DIN16 x 100DIN16 x 100DIN16 x 150DIN16 x 150DIN16 x 150DIN16 x 200DIN16 x 200DIN16 x 200DIN16 x 200
2 x 122 x 122 x 122 x 122 x 122 x 122 x 122 x 122 x 122 x 122 x 12
57078098012601260145017001700170017001700
12501070145013001700188018502300270034004600
8201030123015601560175020002000200020002000
Inle
t /
Out
let
BSP Connections Dimensions*
Size
Gau
ge
(G)
Rel
ief V
alve
(RV
)
2525252525252550505050
Dra
in (D
R)
Ven
t (V
)
Flan
ge
to F
lang
e (F
F)AVBT300AVBT500AVBT1000AVBT1500AVBT2000AVBT3000AVBT4000AVBT5000AVBT6000AVBT7500AVBT10000
Base
Mod
el N
o
Dia
met
er (D
)
16701490192017702170235023202770310039205120
Hei
ght
(H)
BSP Connections Dimension
Standard Vertical Aquazone Buffer Tank
Ove
rall
Hei
ght
(OH
)
45007000100001600020000
Your Size
400400400400400400
253232404050
20003300460055007150
DIN16 x 100DIN16 x 150DIN16 x 150DIN16 x 200DIN16 x 200DIN16 x 200
Size (L)Inlet/Outlet I.O. RV
121212121212
G
253232505050
DR L
22503550485057507400
OL
21002100210023002300
OH
17001700170019001900
D
AHBT4500AHBT7000AHBT10000AHBT16000AHBT20000
PN16 FlangedConnection
BaseModel No BSP Connections Dimensions*
PN16 FlangedgBaseM N BSP Connections Dimensions*
Standard Horizontal Aquazone Buffer Tank
AQUAZONE
Please Note: All sizes can vary. Always confirm with Sales Office.*These dimensions are without insulation.
*These dimensions are without insulation.
Please Note: All sizes can vary. Always confirm with Sales Office.
Buffer Tanks For Chilled & Heating Water Circuits
PAPPCCKAKKGESOLU
TION
SFO
R THE HVVAVV C MARKET
116 CarnarvonStreet,Silverwater NSW Australia 2128Phone +61 2 9748 2022Fax +61 2 9748 2099Emaiil [email protected] 19 263 779 936
AQUAZONE
Insulation & CladdingStandard insulation is polyethylene foam in 50mm thicknesswith an outer cladding to encase the insulation.‘R’ valves of 1.8 in accordance with Section J of the Building Code of Australia (BCA). Refer to our separate insulation technical Data sheets for more information.
Thermal Storage TanksAquazone tanks can be provided with internal sparge pipes sothat incoming liquid is dispersed evenly throughout the tank. The resulting temperature stratification coupled with correctly sized insulation provides an effective Thermal Energy Storage Tank for use in chilled and heating water applications.
AccessoriesAquazone buffer tanks are supplied with standard accessories and optional extras when required:-· Pipe pieces for drain extension· Isolating valves for vent and drain nozzles· Relief valve-preset.
Optional accessories· Flexible connectors (C’flex) for inlet and outlet· Sparge pipe· Baffles· Air release valve· Pressure gauge and /or temperature probes· Level gauges and alarms· Provision for cathodic protection
s
arnarvonStreet,water NSW Australia 2128
+61 2 9748 2022+61 2 9748 2099
et
IInSStww‘‘RCCotte
ThTAAqthThsiz
Masterflow reserve the right to make changes without notice
Tank, Insulation & Accessories...Your Single Source Supplier