    Bruker Daltonics

    The new ultraeXtreme shatters the previous limitations

    o MALDI mass spectrometry. Ultra ast, yet exible with

    high perormance, the ultraeXtreme MALDI TOF/TOF

    provides researchers with the most potent instrument or

    a variety o applications.

    The ultraeXtreme boasts a number o technology

    breakthroughs to deliver a host o benefts to researchers

    including:

    Unmatched Analytical Speed with true One kilohertz

    laser and system electronics in MS and MS/MSmodes

    Outstanding Molecular Identifcation with Sub ppm

    Mass Accuracy and up to 40,000 (FWHH) Resolution

    Expanded protein/peptide identifcation capabilities

    with wider mass range analysis capabilities

    Exceptional Molecular Imaging with the 10 micron

    laser ocus resolution, non-destructive Smartbeam II

    laser

    Minimized maintenance with the Perpetual sel

    cleaning Ion Source that cleans the instrument source

    in minutes

    Optimized Sotware packages or many Applications

    The ultraeXtreme truly represents a leap orward in

    MALDI technology and the perormance o the system

    ar surpasses the capabilities o earlier generation

    instrumentation. The ultraeXtreme truly redefnes what is

    possible with MALDI Mass Spectrometry.

    Easy, Direct in vitro and in vivo

    Analysis of Lipids, Phospholipids

    and Gangliosides with TLC and

    MALDI TOF

    Figure 1: TLC Plate holder or MALDI-TOF Instrument.

  • 8/3/2019 Appln Note for Lipids

    2/2

    As shown in the current study, the ultraleXtreme repre-

    sents a signiicant advance in capabilities or a MALDI

    type Mass Spectrometer compared to earlier generation

    instrumentation or analysis o lipids. The ultraleXtreme is

    capable o readily analyzing a number o lipids and lipid likemolecules including atty acids, phospholipids, phosphoti-

    dyl inositol, gangliosides, etc. Bruker Daltonics has deve-

    loped a combination o hardware and sotware tools or

    easy analysis o lipids as analyzed by TLC. The use o the

    ultraleXtreme and its powerul analytical capabilities oers

    researchers an exciting new level o capabilities or the in

    vitro and in vivo analysis o lipids and related compounds.

    Figure 3: Identiication o Phospholipid containing saturated and

    unsaturated lipids on phosphotidyl ethanolamine backbone.

    Bruker Daltonics Inc.

    Billerica, MA 01824

    Phone +1 (978) 663-3660

    Fax +1 (978) 667-5993

    [email protected]

    Bruker Daltonik GmbH

    Bremen, Germany

    Phone +49 (0)421-2205-0

    Fax +49 (0)421-2205-103

    [email protected]

    www.bdal.com

    Figure 2: Identiication o Phosphotidyl Choline (m/z 760) by

    TLC MALDI.

    Figure 4: Ganglioside and Sphingosine distribution in developing

    tissue imaged by MADLI TOF.

    Further Reading

    ultraleXtreme Product

    Brochure

    Application Note #96

    Application Note #97

    Technical Note #31