OPTIFLUX 2000 Sensor Offers Watertight Reliability • Sensor with special coating and IP 68 allows for buried installation • Fully welded maintenance free construction with no moving parts • Accurate and reliable measurements 1. Background The goal to which the experts of Dunea are committed to every day is the production of high quality and reliable drinking water in harmony with nature. Over 1.2 million people living in the western part of South Holland rely on Dunea to supply drinking water 24 hours a day. Water is abstracted in the dunes between the cities Monster and Katwijk located along the North Sea coast. The method for preparing drinking water is unique and not used anywhere else in the world. Dune passage is a natural treatment method whereby human errors are practically ruled out and forms an environmentally friendly alternative to the purification of water with chemicals. The water resources in the dunes are sufficient for months of supply. Besides the purification of drinking water, Dunea manages the stunning nature of the dunes and protects the abstraction of drinking water. 2. Measurement requirements Dunea required electromagnetic flowmeters for the accurate measurement of the volume of water that is transported from its water resources in the dunes to its purification plant. The pipe has a diameter of DN 900. The main requirement of Dunea for the flowmeter has been that it is installed underground and that it is protected against temporary submersion. Also the accuracy and reliability of the measurement have been taken into consideration while selecting a flowmeter. In order to maintain the water balance, Dunea gets permission for abstracting water from its resources and therefore the volumes of water needs to be monitored accurately. See the location of the flowmeter, any repair or maintenance activities that need to be done are very costly. APPLICATION REPORT Water & Wastewater

Upload: others

Post on 13-Feb-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Application 251 EN 3 - KROHNE · Please visit our website for a current list of all KROHNE contacts and addresses. APPLICATION REPORT 1 Water pumped from dunes, 2 Flow meter, 3 Water

OPTIFLUX 2000 Sensor Offers Watertight Reliability

•SensorwithspecialcoatingandIP68allowsforburiedinstallation•Fullyweldedmaintenancefreeconstructionwithnomovingparts•Accurateandreliablemeasurements

1. Background ThegoaltowhichtheexpertsofDuneaarecommittedtoeverydayistheproductionofhighqualityandreliabledrinkingwaterinharmonywithnature.Over1.2millionpeoplelivinginthewesternpartofSouthHollandrelyonDuneatosupplydrinkingwater24hoursaday.WaterisabstractedinthedunesbetweenthecitiesMonsterandKatwijklocatedalongtheNorthSeacoast.Themethodforpreparingdrinkingwaterisuniqueandnotusedanywhereelseintheworld.Dunepassageisanaturaltreatmentmethodwherebyhumanerrorsarepracticallyruledoutandformsanenvironmentallyfriendlyalternativetothepurificationofwaterwithchemicals.Thewaterresourcesinthedunesaresufficientformonthsofsupply.Besidesthepurificationofdrinkingwater,Duneamanagesthestunningnatureofthedunesandprotectstheabstractionofdrinkingwater.

2. Measurement requirements

Dunearequiredelectromagneticflowmetersfortheaccuratemeasurementofthevolumeofwaterthatistransportedfromitswaterresourcesinthedunestoitspurificationplant.ThepipehasadiameterofDN900.ThemainrequirementofDuneafortheflowmeterhasbeenthatitisinstalledundergroundandthatitisprotectedagainsttemporarysubmersion.Alsotheaccuracyandreliabilityofthemeasurementhavebeentakenintoconsiderationwhileselectingaflowmeter.Inordertomaintainthewaterbalance,Duneagetspermissionforabstractingwaterfromitsresourcesandthereforethevolumesofwaterneedstobemonitoredaccurately.Seethelocationoftheflowmeter,anyrepairormaintenanceactivitiesthatneedtobedoneareverycostly.

APPLICATION REPORT Water & Wastewater

Application 251 EN 3.indd 1 22.06.2010 9:34:24 Uhr

Page 2: Application 251 EN 3 - KROHNE · Please visit our website for a current list of all KROHNE contacts and addresses. APPLICATION REPORT 1 Water pumped from dunes, 2 Flow meter, 3 Water

©KROHNE5/2010-25

1-Sub

jectto

cha

ngewith

outn

otice

Processofnaturalpurificationofdrinkingwater

3. KROHNE solution

Forapplicationswheretheflowmeterissubjecttotemporaryorpermanentsubmersionunderwater,suchasinbasements,pitsorlocationswherethemeterisburiedunderground,KROHNEhasanexcellentsolution:theOPTIFLUX2000.• Themeasuringtubeconsistsofafullyweldedstainlesssteelconstruction.Asaresulttheconstructionis100%watertightandleakfree.Itisnotnecessarytouseburial(‘bitu’)tapeasisoftenthecasewiththreadedconstructions.

• Theflowmetercanbeconstructedentirelyofstainlesssteelandhasnoplasticparts.Alsotheconnectionboxontheflowsensor,forhousingthepowercablesbetweentheflowsensorandtheconverter,canbesuppliedinstainlesssteel.Competitiveproductsoftenuseplasticmaterials,whosequalitydeteriorateovertimeandmaycauseleaks.

• Thecablescanbepouredoffalreadyduringmanufacturinginthefactoryinlengthsspecifiedbythecustomer.Duringinstallationnoadditionalactionsareneeded.

• Theflowsensorcanbeprovidedwithagroundcoatingespeciallydevelopedfortheburiedinstallations.

4. Customer benefits

Theexcavationofameter,forexampleformaintenancepurpose,comeswithhighcostswhichthecustomerwantstoavoidasmuchaspossible.Themaintenance-freeconstructionofOPTIFLUX2000,asdescribedabove,gaveDuneatheconfidencetochoosefortheKROHNEsolution.Moreover,theOPTIFLUX2000isveryeasytoinstall.Integrateddiagnosticfunctionsofferthecustomertheassurancethatshouldproblemariseeitherintheprocessorwiththeflowmeter,thecustomerreceivesawarning.ThisconstructionisusedbyDuneaandmanyotherclientsalreadyforyearstotheircompletesatisfactioninundergroundinstallations.

5. Product used

OPTIFLUX 2000 electromagnetic flowmeter • DiameterrangeuptoDN3000• IP68protectionclass• Polypropyleneorhardrubberliner

3

1

4

5

76

10

8 9

2

Contact

PleasevisitourwebsiteforacurrentlistofallKROHNEcontactsandaddresses.

APPLICATION REPORT

1Waterpumpedfromdunes,2Flowmeter,3Watersoftening,4Carbondosage,5Cascades,6Filters,7Slowfilters,8Cleanwaterbasements,9Watertower,10Tocustomers