Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
1 of 28
Tank Farm Maintenance Procedure 242-A Evaporator
USQ # N/A-4
CHANGE HISTORY ( LAST 5 REV-MODS )
Rev-Mod Release Date Justification: Summary of Changes
B-7 04/10/2018 Maintenance Request Add “K1-“ to FTP’s in Table 1.
B-6 12/11/2017 Maintenance Request Removed “DUE” from Step 1. Remove Initials/Date from
multiple locations.
B-5 08/16/2017 Maintenance Request
Initial lines changed to signature lines on Data Sheets 1 & 6,
Step 7 of Data Sheet 3 reworded and extra step added to Data
Sheet 6.
B-4 05/03/2017 Periodic Review Changed Operating Range values and deleted row in Data Sheet
3, and record section upgrade.
B-3 11/20/2014 CHAMPS Removal Removed reference to CHAMPS, updated records statements
and removed next periodic review date.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
2 of 28
Exhauster 296-A-21A SYSTEM-SPECIFIC DATA
GENERAL INFORMATION
Transition plenum 30" i.d. (inside diameter)
Flow Test Ports: K1-FTP-403 , K1-FTP-404 1” NPT pipe nipple located at 40’ 2 87 ” and K1-FTP-406
6”Manual test port located at 40’ 2 87 ”
Exhaust Fan: K1-5-2, K1-5-3; 18409 cfm at 59 F/19474 cfm at 115 H-14-108570 Sht. 2
HEPA Filters: K1-6-1 through K1-6-6; (2 in series per Train; 2 Trains in parallel); see H-14-108570 Sht. 1
PRECAUTIONS & LIMITATIONS
Ladder for flow testing on filter train “A” (K1-FTP-085).
PREREQUISITES
No additional prerequisites. See 3-VBP-656.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
3 of 28
Records
This procedure is performed within a work package, as such, the procedure in its entirety will be
maintained as a record per the Work Control process.
The record custodian identified in the company-level Records Inventory and Disposition
Schedule (RIDS) is responsible for record retention in accordance with
TFC-BSM-IRM_DC-C-02.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
4 of 28
Data Sheet 1
INSTRUMENT CALIBRATION DATA
Step 1
AIR FLOW INSTRUMENT PHOTOMETER
Flow Instrument Type
Equipment Number
Code Number
Code Number
Cal Due Date
Cal Date
Cal Due Date
AEROSOL GENERATOR
Model Number
Model Number
Equipment Number
Equipment Number
Functional Test Due Date
Functional Test Due Date
Aerosol Type
Aerosol Type
Step 2
ADDITIONAL INSTRUMENT CALIBRATION DATA
Comments:
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
5 of 28
Data Sheet 2
PRE-JOB SURVEY FILTER TRAIN “A”
Step 3
Perform pre-job radiation and contamination survey.
/ /
Signature Print (First & Last) Date
HPT
EXTERNAL VISUAL INSPECTION CHECKLIST* YES NO N/A
Step 4
Filter housing access adequate?
Housekeeping adequate?
Adequate number/acceptable condition of operable latches on access doors?
Sample and injection ports equipped with caps, plugs or covers?
Lighting levels adequate?
Housing or ductwork damaged (no apparent leaks on housing penetrations)?
Test ports available (Figure 1)?
Test ports labeled?
Housing door or seal damaged or leaking?
Installed pressure gauges labeled?
Instrumentation damaged (broken, disconnected)?
Filter damaged (tears, holes, frame separation)?
Evidence of moisture in housing (stains, water)?
Step 5
Comments:
* Not all inspections required by ASME/ANSI N511 are listed on this checklist.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
6 of 28
Data Sheet 3
DIFFERENTIAL PRESSURE READINGS
Step 6
FILTER DP
GAUGE LOCATION
READING
(in. wg)
OPERATING
RANGE * (in.
wg)
RESULTS
FILTER TRAIN A
Prefilter
K1-15-3 PDIT-K1-306
East end of filter
housing
0.00 min.
1.30 max.
PASS
FAIL
1st Stage
K1-6-3 PDIT-K1-307
0.30 min.
3.80 max.
PASS
FAIL
2nd Stage
K1-6-6 PDIT-K1-308
0.30 min.
2.30 max.
PASS
FAIL
* See RPP-11413, Technical Basis for Ventilation System Requirements for absolute limits.
Step 7
FWS signature required if any trial fails due to DP readings being out of range.
/ /
Signature Print (First & Last) Date
Facility Supervisor/FWS
Comments
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
7 of 28
Data Sheet 4
SYSTEM AIR FLOW READINGS (DUCTS)
FILTER TRAIN “A”
K1-FTP-085
Step 8
Traverse Points* (in.)
VP
(in. wg)
Velocity**
(fpm)
21
2 21
4 21
6 21
10 21
19 21
23 21
25 21
27 21
29 21
Step 9 Port Total (fpm)
Step 10 Average fpm = Total fpm 10
Step 11
Type-S Pitot Tube
= Average fpm (avg) x Type-S Pitot coefficient x duct area
= fpm (avg) x 0.84 x 4.91 sq ft
* Traverse points are measured relative to inside diameter (i.d.); none may be located within 0.5 in.
of stack walls (40 CFR 60, APP. A).
** Velocity (fpm) = 4005
VP
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
8 of 28
Data Sheet 5 (Sheet 1 of 18)
(TRAIN “A”)
242-A Primary Filter K1-6-3 Top First (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
9 of 28
Data Sheet 5 (Sheet 2 of 18)
(TRAIN “A”)
242-A Primary Filter K1-6-3 Top Second (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
10 of 28
Data Sheet 5 (Sheet 3 of 18)
(TRAIN “A”)
242-A Primary Filter K1-6-3 Top Third (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
11 of 28
Data Sheet 5 (Sheet 4 of 18)
(TRAIN “A”)
242-A Secondary Filter K1-6-6 Top First (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
12 of 28
Data Sheet 5 (Sheet 5 of 18)
(TRAIN “A”)
242-A Secondary Filter K1-6-6 Top Second (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
13 of 28
Data Sheet 5 (Sheet 6 of 18)
(TRAIN “A”)
242-A Secondary Filter K1-6-6 Top Third (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
14 of 28
Data Sheet 5 (Sheet 7 of 18)
(TRAIN “A”)
242-A Primary Filter K1-6-3 Middle First (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
15 of 28
Data Sheet 5 (Sheet 8 of 18)
(TRAIN “A”)
242-A Primary Filter K1-6-3 Middle Second (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
16 of 28
Data Sheet 5 (Sheet 9 of 18)
(TRAIN “A”)
242-A Primary Filter K1-6-3 Middle Third (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
17 of 28
Data Sheet 5 (Sheet 10 of 18)
(TRAIN “A”)
242-A Secondary Filter K1-6-6 Middle First (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
18 of 28
Data Sheet 5 (Sheet 11 of 18)
(TRAIN “A”)
242-A Secondary Filter K1-6-6 Middle Second (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
19 of 28
Data Sheet 5 (Sheet 12 of 18)
(TRAIN “A”)
242-A Secondary Filter K1-6-6 Middle Third (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
20 of 28
Data Sheet 5 (Sheet 13 of 18)
(TRAIN “A”)
242-A Primary Filter K1-6-3 Bottom First (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
21 of 28
Data Sheet 5 (Sheet 14 of 18)
(TRAIN “A”)
242-A Primary Filter K1-6-3 Bottom Second (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
22 of 28
Data Sheet 5 (Sheet 15 of 18)
(TRAIN “A”)
242-A Primary Filter K1-6-3 Bottom Third (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
23 of 28
Data Sheet 5 (Sheet 16 of 18)
(TRAIN “A”)
242-A Secondary Filter K1-6-6 Bottom First (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
24 of 28
Data Sheet 5 (Sheet 17 of 18)
(TRAIN “A”)
242-A Secondary Filter K1-6-6 Bottom Second (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
25 of 28
Data Sheet 5 (Sheet 18 of 18)
(TRAIN “A”)
242-A Secondary Filter K1-6-6 Bottom Third (Figure 1)
AEROSOL TEST READINGS
STEP TRIAL 1 TRIAL 2 TRIAL 3
12
Generator: psi
Generator: psi
Generator: psi
13*
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
(Scale X Reading = Eq. Input)*
X = Cb
14**
X = Bb
X = Bb
X = Bb
X = Bp
X = Bp
X = Bp
15*
X = Cp
X = Cp
X = Cp
AEROSOL PENETRATION CALCULATIONS**
16*
b
p
C
CP 100 *
b
p
C
CP 100 *
b
p
C
CP 100 *
100P *
100P *
100P *
P =________%
P =________%
P =________%
17 PASS = P < 0.05% FAIL = P 0.05%
PASS / FAIL PASS / FAIL PASS / FAIL
18
Fac. FWS signature required if ANY trial fails:
/ /
Signature Print (First & Last) Date
Facility FWS
* Some photometers are auto-ranging and calculating which cannot be manually scaled. Enter
"N/A" or "Auto" in scale and calculation spaces for those cases.
** Background concentrations (Bb, Bp) are for information only and are not part of percent
penetration calculation.
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
26 of 28
Data Sheet 6
Field Review
Step 19
Perform post-job radiation and contamination survey.
/ /
Signature Print (First & Last Name) Date
HPT
Step 20
Vent and Balance lead filling out Data Sheets.
Signature
Vent and Balance Lead
(First & Last)
Date
Step 21
Facility Supervisor/FWS VERIFY all caps, plugs, and instrumentation have been restored to original
configuration.
Ventilation system restored to operating configuration:
____________________________
Supervisor/FWS (Signature)
_________________________________
Supervisor/FWS (Print First & Last)
__________
Date
Step 22
Facility Supervisor/FWS NOTIFY Responsible Engineer immediately for any failed items. Enter name of
engineer contacted if failed items exist AND RECORD work request number(s) for items requiring
additional maintenance OR enter N/A if no failed items exist. Forward Work Package to Vent and Balance.
_______________________
Engineer contacted
_______________________
Work Request Number
_______________________
Date
_______________________
Work Request Number
Post Field Work Review
Step 23 Document RSR#: ____________________________
Step 24
Vent and Balance reviewer VERIFY Data Sheets are accurate, complete, and legible. Sign when complete
and forward work package to Planner.
_______________________
Vent and Balance Reviewer (Signature)
_______________________
Vent and Balance Reviewer
(Print First and Last Name)
___________
Date
Comments:
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
27 of 28
Table 1 - HEPA Filter Test Ports for Train A Filters
Filter Train “A” K1-6-3 Filters
Baseline Inject K1-FTP- 004 (F,S,T)
Sample K1-FTP- 007 (F,S,T)
Penetration Inject K1-FTP- 004 (F,S,T)
Sample K1-FTP- 017 (F,S,T)
Baseline Inject K1-FTP- 005 (F,S,T)
Sample K1-FTP- 008 (F,S,T)
Penetration Inject K1-FTP- 005 (F,S,T)
Sample K1-FTP- 018 (F,S,T)
Baseline Inject K1-FTP- 006 (F,S,T)
Sample K1-FTP- 009 (F,S,T)
Penetration Inject K1-FTP- 006 (F,S,T)
Sample K1-FTP- 019 (F,S,T)
Filter Train “A” K1-6-6 Filters
Baseline Inject K1-FTP- 014 (F,S,T)
Sample K1-FTP- 017 (F,S,T)
Penetration Inject K1-FTP- 014 (F,S,T)
Sample K1-FTP- 020 (F,S,T)
Baseline Inject K1-FTP- 015 (F,S,T)
Sample K1-FTP- 018 (F,S,T)
Penetration Inject K1-FTP- 015 (F,S,T)
Sample K1-FTP- 021 (F,S,T)
Baseline Inject K1-FTP- 016 (F,S,T)
Sample K1-FTP- 019 (F,S,T)
Penetration Inject K1-FTP- 016 (F,S,T)
Sample K1-FTP- 022 (F,S,T)
Appendix E
242-A Building Exhauster Train A HEPA Filter Aerosol Test Data Sheets
HEPA Filter Aerosol Test Data Sheets
Type
CONTINUOUS Document No.
3-VB-656E Rev/Mod
B-7 Release Date
04/10/2018 Page
28 of 28
Figure 1 - 242-A Filter Trains
Filter Train B
Filter Train A
K1
-5
-3
K1
-5
-2
Filter Test Port
Arrangement as followsF = First
S = Second
T = Third
Filter Train C
K1-6
-6
Aerosol Injection
Ports 014 thru 016
Aerosol Injection
Ports 039 thru 041
Aerosol Injection
Ports 054 thru 056Ports
Aerosol Injection
064 thru 066
Aerosol Injection
Ports 029 thru 031
Aerosol Injection
Ports 004 thru 006
PR
E
–
FIL
TE
RP
RE
–
F
IL
TE
RP
RE
–
F
ILT
ER
K1- FTP- 085
K1- FTP- 086
K1- FTP- 087
057
058
059
S T
F S T
FST
054
055
056
T S
TS
TSF
F F
F
067
068
069
ST
F ST
FS T
064
065
066
TS
T S
TSF
F F
F
070
071
072
ST
F ST
FST
F
020
021
022
ST
F ST
FST
F
045
046
047
ST
FST
FST
F
K1-6
-1K
1-6
-3
K1
-15
-2
K1
-15
-3
K1
-15
-1
K1-6
-2
K1-6
-5K
1-6
-4
017
018
019
ST
F ST
FS T
014
015
016
TS
T S
TSF
F F
F
032
033
034
ST
F ST
FS T
029
030
031
TS
T S
TSF
F F
F
042
043
044
ST
F ST
FS T
039
040
041
TS
T S
TSF
F F
F
007
008
009
ST
F ST
FS T
004
005
006
TS
T S
TSF
F F
F
NOTE – Damper arms must be in the TEST POSITION
during aerosol testing