Statement of Environmental Effects for a new Telecommunications Facility at the Mihkelson Reserve, Maslin Crescent, QUAKERS HILL NSW 2763 (Lot 2302/DP791592)
COPYRIGHT C WHEREIS REGISTERED TRADEMARK OF SENSIS PTY LTD.R
AutoCAD SHX Text
40
AutoCAD SHX Text
10
AutoCAD SHX Text
20
AutoCAD SHX Text
10
AutoCAD SHX Text
0
AutoCAD SHX Text
20
AutoCAD SHX Text
30
AutoCAD SHX Text
A3
AutoCAD SHX Text
50mm
AutoCAD SHX Text
01
AutoCAD SHX Text
30.09.16
AutoCAD SHX Text
ISSUED FOR APPROVAL
AutoCAD SHX Text
METASITE
AutoCAD SHX Text
BL
AutoCAD SHX Text
LL
AutoCAD SHX Text
RT
AutoCAD SHX Text
PJ
AutoCAD SHX Text
SITE ADDRESS: : MIHKELSON RESERVE MASLIN CRESCENT QUAKERS HILL NSW 2763 NOTES: : 1. BASIS OF DESIGN BASIS OF DESIGN > SITE INSPECTION 12/07/2016 SITE INSPECTION 12/07/2016 2. PANEL ANTENNAS PANEL ANTENNAS > 6-OFF PER SECTOR, 18-OFF TOTAL > eJV CONVERSION PA;A;PA CONFIGURATION > SECTOR 1 - 15°, SECTOR 2 - 150°, SECTOR 3 - 280° SECTOR 1 - 15°, SECTOR 2 - 150°, SECTOR 3 - 280° 3. RRU'S & ANCILLARY EQUIPMENT RRU'S & ANCILLARY EQUIPMENT > RRU'S 36-OFF TOTAL, 6-OFF PER SECTOR FOR OPTUS AND 6-OFF PER SECTOR FOR VHA 4. TRANSMISSION TRANSMISSION > PROPOSED U/G FIBRE ROUTE TO BE CONFIRMED BY PROPOSED U/G FIBRE ROUTE TO BE CONFIRMED BY OPTUS AT DETAILED DESIGN 5. EQUIPMENT SHELTER EQUIPMENT SHELTER > IN SITU BRICK EQUIPMENT SHELTER (6m x 3m) IN SITU BRICK EQUIPMENT SHELTER (6m x 3m) > SUPPORTED ON BORED PIERS/RAFT SLAB/OTHER SUPPORTED ON BORED PIERS/RAFT SLAB/OTHER FOOTING 6. STRUCTURE STRUCTURE > OPTUS 35m HIGH MONOPOLE WITH TRIANGULAR OPTUS 35m HIGH MONOPOLE WITH TRIANGULAR HEADFRAME 7. FEEDER CABLES (HYBRID TRUNK CABLE) FEEDER CABLES (HYBRID TRUNK CABLE) > PROPOSED 3x 6/12" + 3x 9/18" ALL SECTORS > LENGTH: APPROX. 130m ALL SECTORS LENGTH: APPROX. 130m ALL SECTORS > TO RUN IN OPTUS 450mm NEMA 20B ELEVATED CABLE TO RUN IN OPTUS 450mm NEMA 20B ELEVATED CABLE LADDER AND U/G FEEDER CONDUITS VIA FEEDER PIT AND INTERNALLY IN MONOPOLE 8. SITE ACCESS SITE ACCESS > VIA PROPOSED ACCESS ROUTE ON THE TURF & VIA PROPOSED ACCESS ROUTE ON THE TURF & EXISTING CAR PARK OFF MASLIN CRESCENT 9. ANTENNA ACCESS ANTENNA ACCESS > STEP-PEGS WITH 'LAD-SAF' PROVIDED ON MONOPOLE STEP-PEGS WITH 'LAD-SAF' PROVIDED ON MONOPOLE 10. POWER SUPPLY POWER SUPPLY > EXISTING PLAYFIELD CLUBHOUSE CONSUMER MAIN EXISTING PLAYFIELD CLUBHOUSE CONSUMER MAIN AND SWITCHROOM TO BE UPGRADED TO ACCOMMODATE OPTUS SUPPLY AND METER > PROPOSED OPTUS SUBMAINS FROM PROPOSED OPTUS PROPOSED OPTUS SUBMAINS FROM PROPOSED OPTUS METER IN EXISTING PLAYFIELD CLUBHOUSE SWITCHROOM TO ISOLATION ENCLOSURE. POSITION SHOWN ON DRG. APPROX. LENGTH 25m > OPTUS POWER SUPPLY REQUIREMENT IS 63A-3PHASE > FINAL DETAILS TBC AT DETAIL DESIGN STAGE. 11. OTHER OTHER > EXISTING U/G INFRASTRUCTURE TO BE LOCATED AT EXISTING U/G INFRASTRUCTURE TO BE LOCATED AT DETAILED DESIGN STAGE > EXISTING LIGHTING ARRANGEMENT AT EL 18m TO BE EXISTING LIGHTING ARRANGEMENT AT EL 18m TO BE RELOCATED TO NEW MONOPOLE > PROPOSED OPTUS IN SITU BRICK EQUIPMENT SHELTER PROPOSED OPTUS IN SITU BRICK EQUIPMENT SHELTER BRICK WALL AND ROOF TO BE MATCHED WITH EXISTING PLAYFIELD CLUBHOUSE. TBC AT DETAIL DESIGN > DO NOT DRIVE ON THE TURF AS DAMAGE MUST BE DO NOT DRIVE ON THE TURF AS DAMAGE MUST BE MADE GOOD AT OPTUS COST
AutoCAD SHX Text
NOTE: : THIS DRAWING IS DIAGRAMMATIC ONLY AND SHOULD NOT BE SCALED. DIMENSIONS, COORDINATES, AND LEVELS SHOWN ARE NOMINAL AND SUBJECT TO CONFIRMATION BY SURVEYOR.
AutoCAD SHX Text
%%uOVERALL SITE PLAN
AutoCAD SHX Text
1:1000
AutoCAD SHX Text
PROPOSED OPTUS BASE STATION
AutoCAD SHX Text
%%ULOCALITY MAP
AutoCAD SHX Text
1
AutoCAD SHX Text
P2
AutoCAD SHX Text
MASLIN CR
AutoCAD SHX Text
EXISTING 1.2m HIGH BARRIER (TYP.)
AutoCAD SHX Text
EXISTING 18m HIGH LIGHT POLE TO BE REMOVED AND EXISTING AND EXISTING LIGHTING ARRANGEMENT AT EL 18m TO BE RELOCATED ON TO BE RELOCATED ON PROPOSED OPTUS 35m HIGH MONOPOLE.REFER NOTE 8REFER NOTE 8
AutoCAD SHX Text
LOT 2301/DP786830
AutoCAD SHX Text
LOT 541/DP791592
AutoCAD SHX Text
PROPOSED OPTUS 450mm NEMA 20B ELEVATED CABLE LADDER
AutoCAD SHX Text
EXISTING PERGOLA (TYP.)
AutoCAD SHX Text
EXISTING PLAYFIELD CLUBHOUSE BUILDING WITH CANOPY AROUND
AutoCAD SHX Text
PROPOSED OPTUS FEEDER CABLE ROUTE IN U/G uPVC CONDUITS
AutoCAD SHX Text
EXISTING CONTAINER
AutoCAD SHX Text
PROPOSED OPTUS FEEDER DRAW PIT (TYP.)
AutoCAD SHX Text
PROPOSED OPTUS 35m HIGH MONOPOLE WITH TRIANGULAR HEADFREAME
AutoCAD SHX Text
EXISTING PLAYFIELD CLUBHOUSE SITE CONNECTION PILLAR
AutoCAD SHX Text
EXISTING 6m WIDE ACCESS GATES
AutoCAD SHX Text
PRIVATE CONDUIT CAPPED AT SURFACE FOR OPTUS FIBRE
AutoCAD SHX Text
EXISTING PLAYFIELD CLUBHOUSE CARPARK
AutoCAD SHX Text
PROPOSED OPTUS IN SITU BRICK EQUIPMENT SHELTER (6m x 3m). REFER NOTE 11
AutoCAD SHX Text
POSSIBLE CRANE/EWP SETOUT LOCATION
AutoCAD SHX Text
2
AutoCAD SHX Text
P2
AutoCAD SHX Text
PROPOSED OPTUS ACCESS ROUTE. REFER NOTE 8
AutoCAD SHX Text
PROPOSED OPTUS FEEDER DRAW PIT
AutoCAD SHX Text
EXISTING PLAYGROUND
AutoCAD SHX Text
PLAYFIELD
AutoCAD SHX Text
POSSIBLE CRANE/EWP SETOUT LOCATION
AutoCAD SHX Text
PROPOSED OPTUS SUBMAIN IN ROOF SPACE. APPROX. CABLE RUN 25m
AutoCAD SHX Text
EXISTING SWITCHROOM
AutoCAD SHX Text
EXISTING CONSUMER MAINS TO BE UPGRDED. TBC AT DETAIL DESIGN. LOCATION INDICATIVE ONLY
AutoCAD SHX Text
Ofo
AutoCAD SHX Text
Oe
AutoCAD SHX Text
02
AutoCAD SHX Text
06.12.18
AutoCAD SHX Text
ISSUED FOR APPROVAL
AutoCAD SHX Text
MYD
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
AE
AutoCAD SHX Text
PM
AutoCAD SHX Text
LOT 2302/DP791592
AutoCAD SHX Text
LOT 541/DP791592
AutoCAD SHX Text
03
AutoCAD SHX Text
06.12.18
AutoCAD SHX Text
ISSUED FOR APPROVAL
AutoCAD SHX Text
MYD
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
AE
AutoCAD SHX Text
PM
AutoCAD SHX Text
04
AutoCAD SHX Text
18.02.19
AutoCAD SHX Text
ISSUED FOR APPROVAL
AutoCAD SHX Text
MYD
AutoCAD SHX Text
SS
AutoCAD SHX Text
SS
AutoCAD SHX Text
AE
AutoCAD SHX Text
PM
Nokia Networks Pty LtdLevel 5, 60 Union St, Pyrmont NSW 2009T: +61 2 9429-9100 | www.networks.nokia.com