apa frame inspection - indico-fnal (indico)
TRANSCRIPT
![Page 1: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/1.jpg)
APA frame inspection
David Payne
24/10/20
![Page 2: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/2.jpg)
Procedure
● Basicly as defined in PSL TN-2016-03
● Some slight alterations● Frame was in wire
winding frame not free● Survey tool was FARO
Vantage laser tracker
![Page 3: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/3.jpg)
Point location tools
● Workshop at Liverpool made us some custom tools to precisely locate reflector at measurement points
![Page 4: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/4.jpg)
Cross corner deviation
● Tolerance: 2.0mm (1mm target)● On table measurement not possible
– Best alternative was using edging tool, constructing edge lines and corner points, taking distance between points:
![Page 5: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/5.jpg)
Measurements and co-ord system
● 6 points along each beam, 5 along head and foot.– P20 unreachable
due to winding frame- moved to next available point
● Co-ord system defined by plane of P1,P6,P12,P17, origin P20
![Page 6: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/6.jpg)
Flatness and twist
(all mm)
● Overall flatness tolerance: 11.0mm
● Overall twist tolerance 1.0 mm/m (?)
● Split into 5 twist zones (same tolerance)
● Zone 5 shows worst twist, but all within tolerance
![Page 7: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/7.jpg)
Comparison to PSL survey
Daresbury PSL
![Page 8: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/8.jpg)
Bowing (beam by beam)
● Deviation from line between head and foot in z (all mm)
● Tolerance 11.0mm
“right”
“left”“middle”
![Page 9: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/9.jpg)
Straightness
● Straightness of board mounting surfaces
● Deviation in y● Tolerance: 1.5 (1.0 target) ● (all mm)
“middle” (no defined tolerance)
“left”Max y dev. -1.5
“right”Max y dev.-1.2
![Page 10: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/10.jpg)
Comparison to PSL: Straightness
Daresbury
PSL
“Right” “Middle” “Left”
![Page 11: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/11.jpg)
Comparison to PSL
Daresbury PSL
![Page 12: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/12.jpg)
Fold
● Displacement in z of side beams relative to centre beam and z of head and foot
● Tolerance 1.2 mm
z
Fold 1.7 mm
Foot tube Rib 1 Rib 2 Rib 3 Rib 4 Head tube
Fold -0.8 mm
Fold -0.1 mm
Fold -0.6 mm
Fold 1.3 mm
Fold 1.3 mm
![Page 13: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/13.jpg)
Where is “folding” coming from?
● Have measurements along edge of head tube (used in slide 3)
● Suggests deviation is not in frame, but in reference points, or in method used to locate them
● Point location tools lift reflector some distance away from frame– Could be picking up and
amplifying surface shape
De v
iatio
n in
z fr
o m s
t ra
i gh t
y
![Page 14: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/14.jpg)
Summary
● APA surveyed in wire winding frame– Not according to original survey
conditions– Twist and bowing within tolerance– Straightness worse than target
but within tolerance– 3 fold measurements outside
tolerance
![Page 15: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/15.jpg)
Fold: rib 3
Fold 1.3 mm
![Page 16: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/16.jpg)
Fold: rib 4
Fold 1.7 mm
![Page 17: APA frame inspection - INDICO-FNAL (Indico)](https://reader030.vdocuments.mx/reader030/viewer/2022012500/6179d653caf4c518a2071aa9/html5/thumbnails/17.jpg)
Fold: Head tube
Fold 1.3 mm