Important safety instructions• Priortousingtheappliance,readthroughthein
structionsforcompleteuseandretaininasafeplaceforlaterreference.
• WARNING–OnlyusetheUltrasonicindoorsandwithinthespecifiedtechnicaldata.Improperusecanbehazardousforthehealthandleadtocriticalinjury.
• Connecttheunitonlytoalternatingcurrentwithvoltageaccordingtotheratinglabel.
• Childrencannotrecognizethehazardsassociatedwiththeusageofelectricalappliances.Forthisreason,alwayssupervisechildrenwhentheyarenearthehumidifier(image1).
• Neverusetheapplianceifthereisanydamagetotheapplianceorcable(2),aftermalfunction,aftertheappliancehasbeendropped(3)ordamagedinanyotherway.
• Repairsofelectricalappliancesareonlytobemadebyqualifiedserviceengineers(4).Improperrepairworkcancauseconsiderabledangertotheuser.
• Placethehumidifieronadry,levelsurface(5).• Do not place the appliance directly on the flooror
nexttoaheatingvent(6).• Ifthemistcomesincontactwiththefloorpriorto
evaporating,thefloorsurfacecanbecomedamaged.Wedonotacceptanyliabilityfordamagesinthecaseofincorrectplacementoftheunit.
• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chestofdrawers,etc.
• Placeappliancewhereitisnoteasilyknockedover(8).• Alwaysunplugwhennotinuse.• Onlyoperatethehumidifierwhenitiscompletely
assembled.• ALWAYSunplugbeforeremoving/filling/emptyingthe
watertank,beforecleaning/maintaining,assembling/dismantlingofindividualpartsandbeforemovingtheappliance.
• Donottouchthewaterinthebaseduringoperationbecauseofhighfrequencyvibrationsinthewater.
• Donotrunpowercordsundercarpets,anddonotcoverwiththrowrugs.Arrangecordsothatitwillnotbetrippedover.
• Neverpulltheplugfromtheoutletbythecableorwithwethands.
• Donotusetheappliancewherecombustiblegasesorvaporsarepresent.
• Donotexposetheappliancetorain,orusenearwater,inabathroom,laundryareaorotherdamplocation.
• Thisunitmustbeusedinitsuprightposition.• Donotallowforeignobjectstoenterventilationor
exhaustopeningasthismaycauseelectricshockordamagetotheappliance.Donotblockairoutletsorintakes.
• Donotpourwaterintothemistoutletoftheappliance.• Thisappliancehasapolarizedplug(onebladeiswider
thantheother).Toreduceriskofshock,thisplugisintendedtofitinapolarizedoutletonlyoneway.Iftheplugdoesnotfitfullyintheoutlet,reversetheplug.Ifitstilldoesnotfit,contactaqualifiedelectrician.DONOTattempttodefeatthissafetyfeature.
• Aloosefitbetweentheplug(receptacle)andtheACoutletmaycauseoverheatingandadistortionoftheplug.Contactaqualifiedelectriciantoreplacelooseorwornreceptacles.
• Donotsit,standorplaceanyheavyobjectsontheappliance.
• Donotsubmergethemainbodyinwaterorotherliquids.
• Disconnectpowersupplybeforeservicing.• Personswhoarenotfamiliarwiththeinstructions
foruse,aswellaschildrenandpersonsundertheinfluenceofmedication,alcohol,ordrugsarenotpermittedtooperatetheappliance,orareonlypermittedtooperateitundersupervision.
• Toprotecthealth safetyandproper humidifierfunctionuseonlyclean,contamination-free,cold,freshtapwa-terinyourhumidifier.Ifyourwatersourceiscontam-inatedorifyouareuncertainofitssafetyusedistilledwater.Inaddition,itisadvisedtoclean and maintain your humidifierinatimelymanneras instructed in this manual.
• Theuseofwateradditives,suchasethereal/essentialoils,fragrances,eucalyptus,waterconditionersetc.,damagesthetankmaterialandasaconsequencethewholeunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.
• Remark:Neitherhumansnoranimalscanhearthehighfrequencyvibrations.
PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!
7
en
5
1
3
1ft
4ft
3ft
7
96
2
4 en
8
8
en ForewordCongratulations on choosing theUltrasonicAIROSWISS7142!
Didyouknowthatdryroomair:• Causesthemembranesinyourrespiratorysystemto
dryout,andalsocauseschappedlipsandstingingeyes?
• Encouragesinfectionsandillnessesofrespiratorysystem?
• Causesweariness,tirednessandpoorconcentration?• Stresseshouseholdpetsandhouseplants?• Encouragestheformationofdustandtheelectrostatic
chargingoftextilesmadeofsyntheticfibers,carpetsandplasticflooring?
• Damagesfurnishingsmadeofwoodandparquet?• Detunesmusicalinstruments?
General informationAcomfortableatmosphere indoors is reachedwitha relativehumidity levelbetween40and60%.Yourhumidifier automatically controls the humidity level accordingtodesiredsetting. If theair is toodry, thehumidifierwillautomaticallyswitchon.Assoonasthedesiredhumiditylevelisreached,itwillswitchoff.
Unpacking• Carefullyremovethehumidifierfromthebox.Place
yourhandsunderneaththeproducttopullitoutofthebox(10).
• Warning:Donottaketheunitoutoftheboxbypullinguponthetankhandlebasemayfallandwillbedamaged(11).
•Warning:Themistoutletispackedinaredbaginsidetheboxinsert.Makesurethatyouremovethemistoutletfromthepackaging(12).
•Removetheplasticbagfromthehumidifier.• Observetheinformationgivenontheratingplateabout
thevoltage.•Thereisaprotectivelabelonthecontrolpanelinorder
toprotectthesurface.Pleaseremoveitasshownbeforethefirstuse(13).
• Usetheoriginalpackagingforstoringtheapplianceifyoudonotusethehumidifierallyearround.
10
11
12
13
9
enSetting upFindingtheideallocationforyourunit:• Donotplacethehumidifierdirectlynexttoaheating
ventoronafloorwithfloorheating.Themoistureofthemistcandamagethefloorsurface(6)(seeSafetyInstructions).
• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chest,etc.atleast3ftoffthefloor.
• Themistoutletmustnotbepointeddirectlyatplants,furniture,orotherobjects(14).Keepdistanceofatleast20inches(50cm).
• Soakthedemineralizationcartridgeinawaterbath24hoursbeforeusingit(15).Thegranuleshavetoabsorbwatertoreachmaximumperformance.Ifitissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.
• Onaveragethedemineralizationcartridgeshouldbereplacedevery2–3monthsdependingonyourwaterhardness.Someareasmayneedtoreplacethecartridgesooner,somemaylastlonger.Thecartridgemustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.
See«Replacementofthedemineralizationcartridge».• Readtheinstructionsunder«FillingtheTank»for
addingwaterinthehumidifier(16and17).• Placethewatertankontothebase.• Inserttheplugintothesocketandswitchonthe
applianceusingtheon/offdial(20).• About10to15minutesafteritisswitchedonthede
vicewillreachitsfulloutputlevel.• Makesurethatthecableisnotpinchedanywhere(9).
Donotoperatethehumidifierifthecableisdamaged(2).
Description of the appliance
Mistoutlet(rotating)
Evaporationchamber
Watertank
Demineralizationcartridge
Mainbody
Controlpanel
Watertankcap
Brush
Airinlet
Membrane
Nebulizerspace
HydroStick
14
24 h
15
10
en
18
19
17 20
16Filling the tankAlways unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!
Toprotecthealth safetyandproper humidi-fierfunctionuseonlyclean,contamination-free,cold,freshtapwaterinyourhumidifier.Ifyour
watersourceiscontaminatedorifyouareuncertainofitssafetyusedistilledwater.
Do not operate the humidifier when the water tank isempty!Whenthewaterreachestheminimumlevel,theunitswitchesoffthenebulizerfunctionautomatically.Theredlightcomesonindicatingtankisempty.
•Removethewatertankfromthebaseandunscrewthewatertankcap(16).Caution:themistoutletisloose!
• Makesurethatnoforeignobjectsareinthewatertank.
• Fillthetankwithclean,coldwaterfromthetap(17).Closethecapofthewatertanksecurely,placethewatertankontothebase(18).Thewaterisnowrunningfromthetankintothebase.
• Donotpourwaterintothemistoutletoftheappliance(19).
• Inserttheplugintothesocketandswitchontheapplianceusingtheon/offdial(20).Theemptyindicatorlightmaystayilluminatedforsomesecondsuntilthebaseisfilledwithwater.
Do not use additivesWater additives (ethereal/essential oils, fragrances,eucalyptus, water conditioners, etc.) must not be used!Evenasmallamountcancausecracksinthematerial.Thematerialisn’tmadefortheuseofsuchadditives.Onedropisenoughtodamagethetankandasaconsequencetheunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.
11
en
A) On/Off ButtonYoucanswitchtheunitonoroffbypressingbuttonA.Thisbuttonisalsousedtoresetthecleaningindicatorlight(byholdingdown).
B) Hygrostat (setting the humidity level)By pressing multifunctional button B (vertical) you cansetthedesiredhumiditylevelin%.Arelativehumidityofbetween40and60% is recommended.Theaccuracyofmeasurementis+/5%.Theunitwillswitchoffwhenthemoisturelevelexceedsthedesiredsetting.Duringselectionthetargetvalueisdisplayed.Thedisplaywillautomaticallyshowthecurrentvalueafterafewseconds.
Operation 7142 C) TimerUsingmultifunctionalbuttonC(horizontal),theoperationtimecanbesetadjustablebetween1and8hoursorCO(continuousoperation).Symbol Gshowstheoperatingperiodthathasbeenset(1h/2h/3h/4h/5h/6h/7h/8h/CO).Thedisplaywill automatically show thecurrent valueafter afewseconds.
D) Mist output (regulating mist output)ByrepeatedlypressingbuttonDyoucancontrolthemistoutput.TheLO/ME/HIdisplay(symbol H)showswhichofthethreelevels(low/medium/high)youhaveselected.
E) Operation with pre-heating (warm mist)ButtonEisusedforswitchingthepreheatingonandoff(symbol Ilightsup).Asaresult,thewaterispreheatedtoa temperatureof176°F (80°C) beforeentering thenebulizerspace.Ittakesapprox.10to15minutesforthewater in thebase towarmup.Themistnow leaves thehumidifieratapleasanttemperatureof104°F(40°C).Theadvantageofthis isthattheroomtemperaturedoesnotdropand, inaddition, it significantly improves thewaterqualitymaintenance.
F) Automatic mode and Sleep modeTheautomaticandsleepmodescanbeactivatedbypressingbuttonF.Bypressingthebuttononce,theautomaticfunctionisswitchedon(symbol Jappearsonthedisplay),maintainingtheoptimumhumiditysubjecttothetemperature.Controltakesplacebymeansofoutputquantityandpreset targetvalue. If thesleepfunction isswitchedon(thesymbol Kappearsonthedisplay),thetargethumidityis60%;theoperationtimeisautomaticallysetat6hours;theheatingisswitchedon.Inaddition,theoutputquantityis also controlled subject to the difference between thetargetvalueandtheactualvalue.TheTimercannotbechangedineithermode.Ifotherbuttonsarepressed,theunitwillnolongerbeinautoorsleepmode.
J
G H
AF
DE
BC
K L I M
G) Timer Indicator
H) Mist Output Indicator
I) Pre-heating Indicator
J) Automatic Mode Indicator
K) Sleep Mode Indicator
L) Empty indicatorThewater level iseasytosee,thankstothetransparentwatertank.Theappliancealsoalertsyouwhenthewatertankisempty.Theemptyindicatorisilluminated(symbolL).Pleasereadthechapter«Fillingthetank»formoreinformation.TheSymbolLmaystayilluminatedforsomesecondswitharefilledtankuntilthebaseisfilledwithwater.
M) Cleaning indicatorIfsymbolMand«CLEAN»appearonthedisplay,theapplianceshouldbecleanedasrecommendedbythemanufacturer.Thissymbolcomesonautomaticallyevery2weeks,dependingonthelevelofuse.The display can be reset by holding down button A until the light disappears.
12
en
ACIDACID
30 min
140°F / 60°C
23
2622
21 25Cleaning/Maintenance Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!
Caution – risk of electric shock and damage of the product!
• Switchofftheapplianceandunplugitfromthesocketbeforecleaningit(21).
• Cleanthewatertankandthebaseregularly.Usewateronly,nodetergents(22).
• UseAIROSWISSEZCalcustomcleaninganddescalingagentonlytoremovedepositsfromthemembraneregularly(23and24).ThereisasampleofEZCalincludedinthepackagingofyourhumidifier.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.DoNOTruntheunitwhenusingEZCal.Thiscancausedamagetotheproductandvoidsthewarranty.ThoroughlyrinsethebasewithpotablewaterafterusingEZCalandmakesurenoEZCalresiduesremaininthebase.
24 27
13
enEZCalfromAIROSWISSistheonlyrecommendedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagetheproduct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.
• Makesuremainbodyisneversubmergedinwater(25)!
• Thecleaningindicatorstillappearsonthedisplayaftercleaning.ToresetitholddowntheON/OFFbuttonuntilthecleanlightstopsflashing.
• Cleantheinnerpartswithasoftcloth.Donotuseanysolventsoraggressivecleaningagentstocleantheappliance(26).
• Onlyusethebrushtocleanthemembrane.Thisshouldbedoneonceaweek.Onlyusethesoftbristleportionofthebrush(27).
• Changethewaterinthetankatleastonceaweekifwaterisstandingformorethanaweek.
Water quality maintenanceTheAIR-O-SWISSHydro Stick 7017 keepsAIR-O-SWISShumidifiersoperatingat theirhighest levelbetween rec-ommended cleanings*. Good for one year, the HydroStick ensures the humidifier’s functionality while provi-ding fresh humidification performance. It starts to workassoonasitcomesintocontactwithwater,evenif theunit is turned off. The Hydro Stick should be changedeveryyear.Lookatpicture28forthepositionof theHy-dro Stick in the base part of the unit. Do not touch thewater in the base during operation! Switch off the unitfirst. Contact your local retailer or check our websitewww.airoswiss.net for reorder information. The replace-mentHydroStickcomeswithametallicclipwhichisnotneededfortheplacementinthisproducttype.
*Refertothecleaninginstructionsinthismanual.
Lifecycle IndicatorYourappliancecomeswithalifecycleindicatorforchangingtheHydroStick.To remindyourselfofwhenyouput theHydroStickintooperation,pleasecrossthecurrentmonthonthestampandwritethecurrentyearonthelineprovid-ed(29).
28
29
14
en 30
31
•Turntheplasticcupandcartridgeoverandshakeuntilallgranulesareinthecartridge(37).
•Removetheplasticcupandthepinkstyrofoampiecefromthecartridge(38)andretainforfutureuse(therefillgranulesconsistsof3refillbags)(39).
•Closethecartridge(40).•Soakthedemineralizationcartridgeinawaterbath 24hoursbeforeusingit(43).Thegranuleshaveto
absorbwatertoreachmaximumperformance.Ifitissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(44).•Screwthecartridgeonthebottomsideofthewater
tank,putthetankonthemainbody(45).
Placinggranules in thecenterof thecartridgeallowsthemtoescapeintheunitortoclogtheunit.Theunitwillnolongeroperateproperlyandthegranulesneedtobecleanedoutthoroughly.
Option B: replace the whole cartridge•Removethewatertankfromthebaseandunscrewthe
watertankcap(30).Caution:themistoutletisloose!•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningitcounterclockwise(31).Important:doNOTdisposeofthewatertankcap!
• Throwthewholecartridgeintothewaste(41).•Unpackthenewcartridge(42).•Soakthedemineralizationcartridgeinawaterbath24
hoursbeforeusingit(43).Thegranuleshavetoabsorbwatertoreachmaximumperformance.Ifitissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.
•Screwthecartridgeonthewatertankcap(44).Closetankcapwellandplacethetankonthemainbody(45).
Replacement of the demineralization cartridge
Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!
Thewatertankisequippedwithademineralizationcartridge.This cartridge has to be replaced every 2 – 3months. Ifthewaterisveryhard, itmaybenecessarytoreplacethecartridgeearlier.Whitedustaroundthedeviceisasuresignthat thecartridgeneeds replacing.Pleasenotewhitedustisnotharmful.Ifwhiteresiduestillformsaroundthedeviceafteranewcartridgehasbeeninserted,pleasemakesurethatthewateryouareusingisuntreated.Ifthewaterflowsthroughadecalcificationsystem–suchasanwatersoftener–(sodiumisaddedtoremovecalcium)inthebuildingbeforeitisusedinthehumidifier,saltcanprecipitateaswhitedustaroundthedevice.Thedemineralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.
Option A: replace the granules•Removethewatertankfromthebaseandunscrewthe
watertankcap(30).Caution:themistoutletisloose!•Thedemineralizationcartridgeisattachedtothetank
cap.Unscrewthecartridgefromthecapbyturningitcounterclockwise(31).Important:doNOTdisposeofthewatertankcap!
•Openthecartridge(32).•Throwthecontentintothewaste(Attention!Disposed
granulescanmakethefloorslippery!)(33).•Placetheenclosedpinkstyrofoampieceinthecenter
ofthecartridge.Donotpushittothebottomasitwillbedifficulttoremoveafterwards(34).
•Pourthecontentsofonerefillgranulesbagintotheplasticcupthatisincludedwiththerefillgranulespackaging(35).
•Placetheemptycartridgewiththepluginthecenterontotheplasticcup(36).
32 33
15
en
45
44
34 35
36
37
38
41
24 h
43
40
42
39
16
en Storing the appliance for extended periodsCleantheapplianceasdescribedearlierandallowtodrythoroughly.Preferablystoretheapplianceinitsoriginalbox,inadryplaceawayfromhightemperatures.
Legal noticeThehumidifieriscULlisted.Subject to technicalchange.The instructions foruseareprotectedbycopyright©PLASTONAG.
AccessoriesContact your local retailer or check our website www.airoswiss.netforreorderinformation.
Customer ServiceCustomerService(USA)18003360326www.airoswiss.net
Technical data
Electricalvoltage 120V/60HzPowerconsumptionupto 45W/(140W*)Humidityoutputupto 3.5gallons/24h*Suitableforroomsupto 860sqft/80m2
Dimensions(LxWxH) 9.8x11.0x17.3in 25x28x44cmWeight(empty) 8.8lbs/4kgAccessories AOS7531Demineralizationcartridge AOS7017HydroStick
*whenusedwithpreheatingto176°F(80°C)
Troubleshooting
Problem Possible cause What to do
Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable
Nowaterinthetank(Emptyindicatoron) Filltankwithwaterandwait10min.
Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCal
Demineralizationcartridgeexhausted Replacecartridgeorgranules
Demineralizationcartridgeoverfilled Takeout2tablespoonsofgranulesandthrow withgranules themaway
Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min. thehumidifierwillworkproperlyagain
Mineraldepositsonmembrane CleanmembraneusingEZCalandbrush
Unitrunningintermittently Replacedemineralizationcartridgeorgranules
Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Usedgranulesmustgoinwaste
17
enGeneral Humidifier Questions
Q.Why isn’t there enough moisture in my room?A. Howoftendoyouruntheunit?Iftheunitisonlyrunat
night,thenduringthedaythemoisturelevelwilldropifmoistureisnotconstantlyaddedtotheair.
Q.Do you leave your door open or closed when the unit is running?
A. a) Byleavingthedooropen,thisallowsmoisturetoleavetheroomandgointootherareasofthehouse.Ifyouwouldlikethemoisturetostaywithinonespecificroomyoushouldconsiderclosingthedoorwhiletheunitisrunning.
A. b)Wood,leather,carpet,curtains,andothertypesoffabricsoakupalotofmoisture,thusnotleavingenoughmoisturefortheair.Ifthewindowisleftopen,thenthisallowsmoisturetoescapetheroom.Anotherfactorisalotoftimestheunitisplacednexttoaheatingdevice.Theideaisthattheairblowingintotheroomwillquicklyplacemoisturearoundtheroom.Unfortunately,thisconceptdoesnotworkbecausethehotaircomingoutofaventwillsoakupmostofthemoisture,andnoneoftheairwithintheroomwillreceiveany.
Q.How much moisture do I need in my room?A. Suggestedhumiditylevelsarebetween40–60%.
Q.What are the effects of too little or too much humidity?
A. Dryaircancausedryskin,staticelectricity,outoftunemusicalinstruments,increasedlevelsofdust(dryaircausesdusttorise),damagetowoodenobjects(dryoutandeventuallycracksappear),discomfort,sickness,anddriesoutnasalmembranes.
Over-humidifyingtheaircancausemoldandwallpapertopeel.
Q.Why do I need a humidifier when I can just open my window?
A. Themoisturelevelwithintheoutsideairisnothighenoughtohumidifyaroom.Thecoldertheairthelessmoistureitiscapabletohold,andthemoretheairisheatedupthepercentageofrelativehumidityislower.Relativehumiditymeanstheamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated.Thedifferenceishigherbetweenoutsideandinsidetemperatures;morehumidificationisneededbecauseofthedryairintheroom.
Q.Where should I place my humidifier?A. Theunitshouldbefree-standingandnotclosetoa
wall,window,door,orthermalbridgesothatairmaycirculatearoundtheunit.
Ultrasonic Frequent Questions
Q.Why does it say open/close on the demineralization cartridge cap?
A. Thesedirectionsarethereincaseyoudecidetousetherefilloptiontoreplacethegranules;thepurposeisforhowtoopenandclosethecap.Ifyoudidopenthecapbeforeplacingitinthewatertank,youwillmostlikelynoticethattherearegranulesinthewatertankandthebaseoftheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!
Q. I just replaced my cartridge, and the contents and water in the base has turned a blue-green color.
A. Thissometimesoccurswhenthecartridge,oreventhegranules,arereplaced.Thisdoesnotoccurwithallreplacementcartridgesorgranules,andisareactionofwatercontentandtheUltrasonicvibrations.Thisisnotanindicatortoreplacethecartridge.
Q.There is no fill-line on the water tank, how far may I fill it up?
A. Thereisnofilllineonthewatertank,anditmaybefilledallthewaytothetop.
Q.What is the purpose of the demineralization cartridge (DMC)?
A. TheDMCremovesmineralsfromthewatertopreventwhitedust.Thecontentsofthecartridgeneedtobesoakedfor24hrspriortofirstusingtheunitsothattheymayfullyexpandandremovemineralsfromthewater.ThecontentsoftheDMChavealifeof2–3months.Thecartridgemayneedtobereplacedmoreoftendependingonwaterhardnessandhowoftentheunitisused.AnindicationofwhentheDMCneedstobechangedcanbewhitedustorreducedamountofmistoutput.
Q. Is it ok to use distilled water with the unit?A. Forbestresultswithyourultrasonichumidifieruse
distilledorreverse-osmosiswaterandremovethedemineralizationcartridge.
Q. I just replaced the contents of the cartridge and now have granules everywhere.
A. First,makesuretherearenogranulesinthemiddleofthecartridge.PlacinggranulesinthemiddleoftheDMCallowsthemtoescapeintheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!
Q. The directions tell me not to place the unit directly on the floor, why do I have to elevate the unit?
A.Theideawiththisunitistoallowonetoforcehumidityintotheair.Becauseofthis,thecarpetingorwoodfloorsurroundingtheunitmaybecomedamp.Iftheunitis
18
en placedatleast3feetoffthefloor,themistwillhavetheopportunitytoevaporatebeforehittingthefloor.
Q. Water does not go into the tank.A.Inordertofillthetank,itmustbeturnedupsidedown.
Thecartridgeisplacedonthewatertankcap.Donotpourwaterinthetubewhichisthemistoutlet.
Q. White dust is emitted from the unitA.Whitedustparticlesaremineralsthatarebrokenupin
tinypiecesbytheultrasonicprocess. Solve the problem:•Soakthedemineralizationcartridgeinabowlofwater
foraminimumof24hours.Ifthecartridgeissoakedinthewatertank,thewaterinthetankandthebaseneedstobereplacedbeforeusingtheunit.
•Exchangethedemineralizationcartridgeafter1-2monthswhenyouuseveryhardwater(forsofterwaterafter2-3months).Nomatterhowhardyourwateris,exchangethecartridgeattheverylatestafter6months.
•Don’tusewaterfromapre-installedwatersoftener,orsodiuminsteadofcalciumwillbeemittedfromtheunit.Usedistilledwaterinsteadandremovethedemi-neralizationcartridge.
•Forveryhardwaterareasuseonlydistilledwaterandremovethedemineralizationcartridge.
•UseReverse-Osmosiswater(R-Owater)insteadofdis-tilledwaterandremovethedemineralizationcartridge.
•Cleaning light is illuminated (digital models) Switchofftheunitandunplugit.Emptythewaterin
thebase.Rinsethebasewithhot/cleanwater.Donotsubmergethebase!Visuallyinspectthebasefordirtormineralbuildup.Ifsoftwaterisused,decalcifytheunitevery4weekswithEZCalissuggested.Ifhardwaterisusedtheunitshouldbedecalcifiedevery2weeks.Donotforgettoresetthecleanlightafterresettingtheunit.
Q.Reset cleaning light (digital models)A. Thecleaninglightdoesnotautomaticallyreset.Hold
downthepowerbutton(buttonAininstructionmanual)untilthelightstopsflashing.Thelightautomaticallycomesonapprox.after14daysofpluggingintheunit.
Q.The hygrometer on unit reads a different humidity level than external hygrometer.
A. Notallhygrometersarecalibratedthesame,andmostareoffby+/-5%.Plusthehumiditylevelisnotthesameinthewholeroom.Theaircirculationisdifferentineverycorneroftheroom.Theunitshouldnotbeplacednearaheatingventoraradiatorastheheatwillabsorballofthemoisture.
Q.Humidity level is not changing or does not reach the desired humidity level.
A. Ifthewatertankneedsrefillingmorethanonceperday,theunitisworkingproperlyandtheclimaticconditionintheroomhasaninfluenceonthehumidity.
Reasons for low humidity level:•aircirculationisveryhigh(airisfullyexchanged
severaltimesperday–thehumidifierneedstostartsitsworkfromscratch)
• insulationofhome(seeaircirculation)•openspacewithhighceilings(notonlythefootageof
theroomcountsbutalsotheheight)–high-risebuil-dingsrequiremorehumidification.
•openwindows–workssimilartoaircirculation(ifitisverycoldoutsidedon’topenthewindowmorethan2timesperdayfor3minutes)
•bigdifferencebetweenoutsidetemperatureandinsidetemperature–thecoldertheairthelessmoistureitiscapabletoholdandthemoretheairisheateduptheloweristhepercentageofrelativehumidity(=theamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated)
•positionoftheunit-ifitisplacedclosetoadoor,windoworairvent.Thisincreasestheaircirculation.
Q.Tank is leakingA. Checkifthereareanyhairlinecracks.Droppedunitsor
watertanksthatarecrackedwillnotbecoveredunderthewarranty.Pleasecontacttheretailertheunitwaspurchasedfromincaseyourunitarrivesdamaged.
Q.Placing the face in the mistA. Itisnotrecommendedthatanybodyplacestheirface
inthemist.Itisanelectricalproductandshouldnotbeplayedwith.
Q.No mist / unit is not working / empty indicator keeps flashing
A. Fillupthewatertank.Checkifwaterisflowingthroughthedemineralizationcartridge(attachedtothewatertankcap).Ifthewatertankisfullbutthereisonlylittlewaterinthebaseitindicatesthatthewaterisnowflowingthroughthedemineralizationcartridge.
•Waitfor15minutestoallowthemisttocomeoutoftheunit.
• Iftheunitisnotworkingandtheemptylightisnotflashingyoumighthavesetthedesiredhumiditytoolowandthecurrenthumiditylevelintheroomishigher.Thatiswhytheunitswitchesoffautomatically.
• Iftheemptyindicatorkeepsflashingandthetankisfull,thewaterisnotflowingthroughthecartridge.Exchangethecartridgeorthegranulesinthecartridgeafter2-3months,inareaswithhardwaterexchangethecartridgeafter1-2months.However,thedemi-neralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore
• Ifthegranulesarenew,seethefollowinginstructions:•Makesurethecartridgeand/orgranulesweresoaked
for24hours,drygranulestakeevenlongerforwatertofilterthroughthecartridgeandintothebase.Next,pleaseremove2tablespoonsofgranulesfromthecartridge,andthrowthemaway.Whentherearetoomanygranulesinthecartridgeitdoesnotallowwatertoflowfromthetanktothebase.
19
enQ.Water tank cap is too tight to unscrewA. Thiscouldbeacauseoftheairpressurewithinthe
watertank.Depressthespringonthebottomofthewatertankcaptoreleaseairfromthewatertank.Continuetodothisuntilyouareabletounscrewthewatertankcap.
Q.Unit is running intermittently.A. Howlonghasitbeensincethecontentsofthe
cartridgewerereplaced?If2-3monthshavepassed,itistimetoreplacethecontentsofthecartridge.Howeverthedemineralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.
• Ifthecontentsofthecartridgewerejustreplacedthereareprobablytoomanygranulesinthecartridge.Re-move2tablespoonsofgranulesfromthecartridge.
Accessories
Q.Do I need to keep any parts before I replace the demineralization cartridge?
A. Yes,alwayskeepthewatertankcap(thisisthepiecethatattachesthedemineralizationcartridgetothewatertank).
Q.What is the Hydro Stick and how long is it good for?
A.TheAIR-O-SWISSHydroStickkeepshumidifiersoperatingattheirhighestlevelbetweenrecommendedcleanings*.Goodforoneyear,theHydroStickensuresthehumidifier’sfunctionalitywhileprovidingfreshhumidificationperformance.Itneedstobereplacedonceayear.
*Refertothecleaninginstructionsinthismanual.
Q.Placement of the Hydro StickA.Pleaseseepicture28forinstructions.
Q.Replacement reminderA.IneachHydroStickboxandonallthenewproducts
thereisaHydroSticklifecycleindicator.ChecktheboxofthemonthwhenstartingtousetheHydroStickandwritetheyearonthelineindicated.Exchangeitafteroneyear.
Q.What is EZCal?A. ThereisasamplepacketofEZCalincludedinthe
packagingofyourhumidifier.EZCalisusedforcleaninganddescalinganyoftheAIR-O-SWISShumidifiersandcleansmineralbuild-up.EZCalistheonlyrecommen-dedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagetheproduct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.Itcanalsobeusedforotherhumidi-fierbrands.ThoroughlyrinsethebasewithtapwaterandmakesurenoEZCalresiduesremaininthebase!EZCalisavailableatselectedretailstoresandonlinewww.airoswiss.net.