Page 1: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

PLEASE READ AND SAVEALL INSTRUCTIONS!

LISEZ ET CONSERVEZTOUTES LES INSTRUCTIONS!

¡POR FAVOR LEA Y GUARDE TODAS LAS INSTRUCCIONES!

AOS 7142

Page 2: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger
Page 3: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

3

Instructions for use (5 – 20) en

Instructions d’utilisation (21 – 36) a fr

Instrucciones para el uso (37 – 51) a es

Page 4: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

4

Page 5: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

5

enInstructions for use

Page 6: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

6

en

Important safety instructions• Priortousingtheappliance,readthroughthein­

structionsforcompleteuseandretaininasafeplaceforlaterreference.

• WARNING–OnlyusetheUltrasonicindoorsandwithinthespecifiedtechnicaldata.Improperusecanbehazardousforthehealthandleadtocriticalinjury.

• Connecttheunitonlytoalternatingcurrentwithvoltageaccordingtotheratinglabel.

• Childrencannotrecognizethehazardsassociatedwiththeusageofelectricalappliances.Forthisreason,alwayssupervisechildrenwhentheyarenearthehumidifier(image1).

• Neverusetheapplianceifthereisanydamagetotheapplianceorcable(2),aftermalfunction,aftertheappliancehasbeendropped(3)ordamagedinanyotherway.

• Repairsofelectricalappliancesareonlytobemadebyqualifiedserviceengineers(4).Improperrepairworkcancauseconsiderabledangertotheuser.

• Placethehumidifieronadry,levelsurface(5).• Do not place the appliance directly on the flooror

nexttoaheatingvent(6).• Ifthemistcomesincontactwiththefloorpriorto

evaporating,thefloorsurfacecanbecomedamaged.Wedonotacceptanyliabilityfordamagesinthecaseofincorrectplacementoftheunit.

• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chestofdrawers,etc.

• Placeappliancewhereitisnoteasilyknockedover(8).• Alwaysunplugwhennotinuse.• Onlyoperatethehumidifierwhenitiscompletely

assembled.• ALWAYSunplugbeforeremoving/filling/emptyingthe

watertank,beforecleaning/maintaining,assembling/dismantlingofindividualpartsandbeforemovingtheappliance.

• Donottouchthewaterinthebaseduringoperationbecauseofhighfrequencyvibrationsinthewater.

• Donotrunpowercordsundercarpets,anddonotco­verwiththrowrugs.Arrangecordsothatitwillnotbetrippedover.

• Neverpulltheplugfromtheoutletbythecableorwithwethands.

• Donotusetheappliancewherecombustiblegasesorvaporsarepresent.

• Donotexposetheappliancetorain,orusenearwater,inabathroom,laundryareaorotherdamplocation.

• Thisunitmustbeusedinitsuprightposition.• Donotallowforeignobjectstoenterventilationor

exhaustopeningasthismaycauseelectricshockordamagetotheappliance.Donotblockairoutletsorintakes.

• Donotpourwaterintothemistoutletoftheappliance.• Thisappliancehasapolarizedplug(onebladeiswider

thantheother).Toreduceriskofshock,thisplugisintendedtofitinapolarizedoutletonlyoneway.Iftheplugdoesnotfitfullyintheoutlet,reversetheplug.Ifitstilldoesnotfit,contactaqualifiedelectrician.DONOTattempttodefeatthissafetyfeature.

• Aloosefitbetweentheplug(receptacle)andtheACoutletmaycauseoverheatingandadistortionoftheplug.Contactaqualifiedelectriciantoreplacelooseorwornreceptacles.

• Donotsit,standorplaceanyheavyobjectsontheappliance.

• Donotsubmergethemainbodyinwaterorotherliquids.

• Disconnectpowersupplybeforeservicing.• Personswhoarenotfamiliarwiththeinstructions

foruse,aswellaschildrenandpersonsundertheinfluenceofmedication,alcohol,ordrugsarenotpermittedtooperatetheappliance,orareonlyper­mittedtooperateitundersupervision.

• Toprotecthealth safetyandproper humidifierfunctionuseonlyclean,contamination-free,cold,freshtapwa-terinyourhumidifier.Ifyourwatersourceiscontam-inatedorifyouareuncertainofitssafetyusedistilledwater.Inaddition,itisadvisedtoclean and maintain your humidifierinatimelymanneras instructed in this manual.

• Theuseofwateradditives,suchasethereal/essentialoils,fragrances,eucalyptus,waterconditionersetc.,damagesthetankmaterialandasaconsequencethewholeunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.

• Remark:Neitherhumansnoranimalscanhearthehighfrequencyvibrations.

PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!

Page 7: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

7

en

5

1

3

1ft

4ft

3ft

7

96

2

4 en

8

Page 8: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

8

en ForewordCongratulations on choosing theUltrasonicAIR­O­SWISS7142!

Didyouknowthatdryroomair:• Causesthemembranesinyourrespiratorysystemto

dryout,andalsocauseschappedlipsandstingingeyes?

• Encouragesinfectionsandillnessesofrespiratorysystem?

• Causesweariness,tirednessandpoorconcentration?• Stresseshouseholdpetsandhouseplants?• Encouragestheformationofdustandtheelectrostatic

chargingoftextilesmadeofsyntheticfibers,carpetsandplasticflooring?

• Damagesfurnishingsmadeofwoodandparquet?• Detunesmusicalinstruments?

General informationAcomfortableatmosphere indoors is reachedwitha re­lativehumidity levelbetween40and60%.Yourhumidi­fier automatically controls the humidity level accordingtodesiredsetting. If theair is toodry, thehumidifierwillautomaticallyswitchon.Assoonasthedesiredhumiditylevelisreached,itwillswitchoff.

Unpacking• Carefullyremovethehumidifierfromthebox.Place

yourhandsunderneaththeproducttopullitoutofthebox(10).

• Warning:Donottaketheunitoutoftheboxbypullinguponthetankhandle­basemayfallandwillbedamaged(11).

•Warning:Themistoutletispackedinaredbaginsidetheboxinsert.Makesurethatyouremovethemistoutletfromthepackaging(12).

•Removetheplasticbagfromthehumidifier.• Observetheinformationgivenontheratingplateabout

thevoltage.•Thereisaprotectivelabelonthecontrolpanelinorder

toprotectthesurface.Pleaseremoveitasshownbeforethefirstuse(13).

• Usetheoriginalpackagingforstoringtheapplianceifyoudonotusethehumidifierallyearround.

10

11

12

13

Page 9: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

9

enSetting upFindingtheideallocationforyourunit:• Donotplacethehumidifierdirectlynexttoaheating

ventoronafloorwithfloorheating.Themoistureofthemistcandamagethefloorsurface(6)(seeSafetyInstructions).

• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chest,etc.atleast3ftoffthefloor.

• Themistoutletmustnotbepointeddirectlyatplants,furniture,orotherobjects(14).Keepdistanceofatleast20inches(50cm).

• Soakthedemineralizationcartridgeinawaterbath24hoursbeforeusingit(15).Thegranuleshavetoabsorbwatertoreachmaximumperformance.Ifitissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.

• Onaveragethedemineralizationcartridgeshouldbereplacedevery2–3monthsdependingonyourwaterhardness.Someareasmayneedtoreplacethecartridgesooner,somemaylastlonger.Thecartridgemustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.

See«Replacementofthedemineralizationcartridge».• Readtheinstructionsunder«FillingtheTank»for

addingwaterinthehumidifier(16and17).• Placethewatertankontothebase.• Inserttheplugintothesocketandswitchonthe

applianceusingtheon/offdial(20).• About10to15minutesafteritisswitchedonthede­

vicewillreachitsfulloutputlevel.• Makesurethatthecableisnotpinchedanywhere(9).

Donotoperatethehumidifierifthecableisdamaged(2).

Description of the appliance

Mistoutlet(rotating)

Evaporationchamber

Watertank

Demineralizationcartridge

Mainbody

Controlpanel

Watertankcap

Brush

Airinlet

Membrane

Nebulizerspace

HydroStick

14

24 h

15

Page 10: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

10

en

18

19

17 20

16Filling the tankAlways unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!

Toprotecthealth safetyandproper humidi-fierfunctionuseonlyclean,contamination-free,cold,freshtapwaterinyourhumidifier.Ifyour

watersourceiscontaminatedorifyouareuncertainofitssafetyusedistilledwater.

Do not operate the humidifier when the water tank isempty!Whenthewaterreachestheminimumlevel,theunitswitchesoffthenebulizerfunctionautomatically.Theredlightcomesonindicatingtankisempty.

•Removethewatertankfromthebaseandunscrewthewatertankcap(16).Caution:themistoutletisloose!

• Makesurethatnoforeignobjectsareinthewatertank.

• Fillthetankwithclean,coldwaterfromthetap(17).Closethecapofthewatertanksecurely,placethewa­tertankontothebase(18).Thewaterisnowrunningfromthetankintothebase.

• Donotpourwaterintothemistoutletoftheappliance(19).

• Inserttheplugintothesocketandswitchontheapplianceusingtheon/offdial(20).Theemptyindica­torlightmaystayilluminatedforsomesecondsuntilthebaseisfilledwithwater.

Do not use additivesWater additives (ethereal/essential oils, fragrances,eucalyptus, water conditioners, etc.) must not be used!Evenasmallamountcancausecracksinthematerial.Thematerialisn’tmadefortheuseofsuchadditives.Onedropisenoughtodamagethetankandasaconsequencetheunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.

Page 11: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

11

en

A) On/Off ButtonYoucanswitchtheunitonoroffbypressingbuttonA.Thisbuttonisalsousedtoresetthecleaningindicatorlight(byholdingdown).

B) Hygrostat (setting the humidity level)By pressing multi­functional button B (vertical) you cansetthedesiredhumiditylevelin%.Arelativehumidityofbetween40and60% is recommended.Theaccuracyofmeasurementis+/­5%.Theunitwillswitchoffwhenthemoisturelevelexceedsthedesiredsetting.Duringselectionthetargetvalueisdisplayed.Thedisplaywillautomaticallyshowthecurrentvalueafterafewseconds.

Operation 7142 C) TimerUsingmulti­functionalbuttonC(horizontal),theoperationtimecanbesetadjustablebetween1and8hoursorCO(continuousoperation).Symbol Gshowstheoperatingpe­riodthathasbeenset(1h/2h/3h/4h/5h/6h/7h/8h/CO).Thedisplaywill automatically show thecurrent valueafter afewseconds.

D) Mist output (regulating mist output)ByrepeatedlypressingbuttonDyoucancontrolthemistoutput.TheLO/ME/HIdisplay(symbol H)showswhichofthethreelevels(low/medium/high)youhaveselected.

E) Operation with pre-heating (warm mist)ButtonEisusedforswitchingthepre­heatingonandoff(symbol Ilightsup).Asaresult,thewaterispre­heatedtoa temperatureof176°F (80°C) beforeentering thenebulizerspace.Ittakesapprox.10to15minutesforthewater in thebase towarmup.Themistnow leaves thehumidifieratapleasanttemperatureof104°F(40°C).Theadvantageofthis isthattheroomtemperaturedoesnotdropand, inaddition, it significantly improves thewaterqualitymaintenance.

F) Automatic mode and Sleep modeTheautomaticandsleepmodescanbeactivatedbypres­singbuttonF.Bypressingthebuttononce,theautomaticfunctionisswitchedon(symbol Jappearsonthedisplay),maintainingtheoptimumhumiditysubjecttothetempera­ture.Controltakesplacebymeansofoutputquantityandpre­set targetvalue. If thesleepfunction isswitchedon(thesymbol Kappearsonthedisplay),thetargethumidityis60%;theoperationtimeisautomaticallysetat6hours;theheatingisswitchedon.Inaddition,theoutputquantityis also controlled subject to the difference between thetargetvalueandtheactualvalue.TheTimercannotbechangedineithermode.Ifotherbut­tonsarepressed,theunitwillnolongerbeinautoorsleepmode.

J

G H

AF

DE

BC

K L I M

G) Timer Indicator

H) Mist Output Indicator

I) Pre-heating Indicator

J) Automatic Mode Indicator

K) Sleep Mode Indicator

L) Empty indicatorThewater level iseasytosee,thankstothetransparentwatertank.Theappliancealsoalertsyouwhenthewatertankisempty.Theemptyindicatorisilluminated(symbolL).Pleasereadthechapter«Fillingthetank»formoreinforma­tion.TheSymbolLmaystayilluminatedforsomesecondswitharefilledtankuntilthebaseisfilledwithwater.

M) Cleaning indicatorIfsymbolMand«CLEAN»appearonthedisplay,theappli­anceshouldbecleanedasrecommendedbythemanufac­turer.Thissymbolcomesonautomaticallyevery2weeks,dependingonthelevelofuse.The display can be reset by holding down button A until the light disappears.

Page 12: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

12

en

ACIDACID

30 min

140°F / 60°C

23

2622

21 25Cleaning/Maintenance Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!

Caution – risk of electric shock and damage of the product!

• Switchofftheapplianceandunplugitfromthesocketbeforecleaningit(21).

• Cleanthewatertankandthebaseregularly.Usewateronly,nodetergents(22).

• UseAIR­O­SWISSEZCalcustomcleaninganddesca­lingagentonlytoremovedepositsfromthemembraneregularly(23and24).ThereisasampleofEZCalin­cludedinthepackagingofyourhumidifier.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.DoNOTruntheunitwhenusingEZCal.Thiscancausedamagetothepro­ductandvoidsthewarranty.ThoroughlyrinsethebasewithpotablewaterafterusingEZCalandmakesurenoEZCalresiduesremaininthebase.

24 27

Page 13: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

13

enEZCalfromAIR­O­SWISSistheonlyrecommen­dedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagetheproduct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.

• Makesuremainbodyisneversubmergedinwater(25)!

• Thecleaningindicatorstillappearsonthedisplayaftercleaning.ToresetitholddowntheON/OFFbuttonuntilthecleanlightstopsflashing.

• Cleantheinnerpartswithasoftcloth.Donotuseanysolventsoraggressivecleaningagentstocleantheappliance(26).

• Onlyusethebrushtocleanthemembrane.Thisshouldbedoneonceaweek.Onlyusethesoft­bristleportionofthebrush(27).

• Changethewaterinthetankatleastonceaweekifwaterisstandingformorethanaweek.

Water quality maintenanceTheAIR-O-SWISSHydro Stick 7017 keepsAIR-O-SWISShumidifiersoperatingat theirhighest levelbetween rec-ommended cleanings*. Good for one year, the HydroStick ensures the humidifier’s functionality while provi-ding fresh humidification performance. It starts to workassoonasitcomesintocontactwithwater,evenif theunit is turned off. The Hydro Stick should be changedeveryyear.Lookatpicture28forthepositionof theHy-dro Stick in the base part of the unit. Do not touch thewater in the base during operation! Switch off the unitfirst. Contact your local retailer or check our websitewww.airoswiss.net for reorder information. The replace-mentHydroStickcomeswithametallicclipwhichisnotneededfortheplacementinthisproducttype.

*Refertothecleaninginstructionsinthismanual.

Lifecycle IndicatorYourappliancecomeswithalifecycleindicatorforchangingtheHydroStick.To remindyourselfofwhenyouput theHydroStickintooperation,pleasecrossthecurrentmonthonthestampandwritethecurrentyearonthelineprovid-ed(29).

28

29

Page 14: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

14

en 30

31

•Turntheplasticcupandcartridgeoverandshakeuntilallgranulesareinthecartridge(37).

•Removetheplasticcupandthepinkstyrofoampiecefromthecartridge(38)andretainforfutureuse(therefillgranulesconsistsof3refillbags)(39).

•Closethecartridge(40).•Soakthedemineralizationcartridgeinawaterbath 24hoursbeforeusingit(43).Thegranuleshaveto

absorbwatertoreachmaximumperformance.Ifitissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.

•Screwthecartridgeonthewatertankcap(44).•Screwthecartridgeonthebottomsideofthewater

tank,putthetankonthemainbody(45).

Placinggranules in thecenterof thecartridgeallowsthemtoescapeintheunitortoclogtheunit.Theunitwillnolongeroperateproperlyandthegranulesneedtobecleanedoutthoroughly.

Option B: replace the whole cartridge•Removethewatertankfromthebaseandunscrewthe

watertankcap(30).Caution:themistoutletisloose!•Thedemineralizationcartridgeisattachedtothetank

cap.Unscrewthecartridgefromthecapbyturningitcounter­clockwise(31).Important:doNOTdisposeofthewatertankcap!

• Throwthewholecartridgeintothewaste(41).•Unpackthenewcartridge(42).•Soakthedemineralizationcartridgeinawaterbath24

hoursbeforeusingit(43).Thegranuleshavetoabsorbwatertoreachmaximumperformance.Ifitissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.

•Screwthecartridgeonthewatertankcap(44).Closetankcapwellandplacethetankonthemainbody(45).

Replacement of the demineralization cartridge

Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!

Thewatertankisequippedwithademineralizationcartridge.This cartridge has to be replaced every 2 – 3months. Ifthewaterisveryhard, itmaybenecessarytoreplacethecartridgeearlier.Whitedustaroundthedeviceisasuresignthat thecartridgeneeds replacing.Pleasenotewhitedustisnotharmful.Ifwhiteresiduestillformsaroundthedeviceafteranewcartridgehasbeeninserted,pleasemakesurethatthewateryouareusingisuntreated.Ifthewaterflowsthroughadecalcificationsystem–suchasanwatersoftener–(sodiumisaddedtoremovecalcium)inthebuildingbeforeitisusedinthehumidifier,saltcanprecipitateaswhitedustaroundthedevice.Thedemineralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.

Option A: replace the granules•Removethewatertankfromthebaseandunscrewthe

watertankcap(30).Caution:themistoutletisloose!•Thedemineralizationcartridgeisattachedtothetank

cap.Unscrewthecartridgefromthecapbyturningitcounter­clockwise(31).Important:doNOTdisposeofthewatertankcap!

•Openthecartridge(32).•Throwthecontentintothewaste(Attention!Disposed

granulescanmakethefloorslippery!)(33).•Placetheenclosedpinkstyrofoampieceinthecenter

ofthecartridge.Donotpushittothebottomasitwillbedifficulttoremoveafterwards(34).

•Pourthecontentsofonerefillgranulesbagintotheplasticcupthatisincludedwiththerefillgranulespackaging(35).

•Placetheemptycartridgewiththepluginthecenterontotheplasticcup(36).

32 33

Page 15: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

15

en

45

44

34 35

36

37

38

41

24 h

43

40

42

39

Page 16: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

16

en Storing the appliance for extended periodsCleantheapplianceasdescribedearlierandallowtodrythoroughly.Preferablystoretheapplianceinitsoriginalbox,inadryplaceawayfromhightemperatures.

Legal noticeThehumidifieriscUL­listed.Subject to technicalchange.The instructions foruseareprotectedbycopyright©PLASTONAG.

AccessoriesContact your local retailer or check our website www.airoswiss.netforre­orderinformation.

Customer ServiceCustomerService(USA)1­800­336­0326www.airoswiss.net

Technical data

Electricalvoltage 120V/60HzPowerconsumptionupto 45W/(140W*)Humidityoutputupto 3.5gallons/24h*Suitableforroomsupto 860sqft/80m2

Dimensions(LxWxH) 9.8x11.0x17.3in 25x28x44cmWeight(empty) 8.8lbs/4kgAccessories AOS7531Demineralizationcartridge AOS7017HydroStick

*whenusedwithpre­heatingto176°F(80°C)

Troubleshooting

Problem Possible cause What to do

Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable

Nowaterinthetank(Emptyindicatoron) Filltankwithwaterandwait10min.

Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCal

Demineralizationcartridgeexhausted Replacecartridgeorgranules

Demineralizationcartridgeoverfilled Takeout2tablespoonsofgranulesandthrow withgranules themaway

Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min. thehumidifierwillworkproperlyagain

Mineraldepositsonmembrane CleanmembraneusingEZCalandbrush

Unitrunningintermittently Replacedemineralizationcartridgeorgranules

Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Usedgranulesmustgoinwaste

Page 17: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

17

enGeneral Humidifier Questions

Q.Why isn’t there enough moisture in my room?A. Howoftendoyouruntheunit?Iftheunitisonlyrunat

night,thenduringthedaythemoisturelevelwilldropifmoistureisnotconstantlyaddedtotheair.

Q.Do you leave your door open or closed when the unit is running?

A. a) Byleavingthedooropen,thisallowsmoisturetoleavetheroomandgointootherareasofthehouse.Ifyouwouldlikethemoisturetostaywithinonespecificroomyoushouldconsiderclosingthedoorwhiletheunitisrunning.

A. b)Wood,leather,carpet,curtains,andothertypesoffabricsoakupalotofmoisture,thusnotleavingenoughmoisturefortheair.Ifthewindowisleftopen,thenthisallowsmoisturetoescapetheroom.Anotherfactorisalotoftimestheunitisplacednexttoaheatingdevice.Theideaisthattheairblowingintotheroomwillquicklyplacemoisturearoundtheroom.Unfortunately,thisconceptdoesnotworkbecausethehotaircomingoutofaventwillsoakupmostofthemoisture,andnoneoftheairwithintheroomwillreceiveany.

Q.How much moisture do I need in my room?A. Suggestedhumiditylevelsarebetween40–60%.

Q.What are the effects of too little or too much humidity?

A. Dryaircancausedryskin,staticelectricity,outoftunemusicalinstruments,increasedlevelsofdust(dryaircausesdusttorise),damagetowoodenobjects(dryoutandeventuallycracksappear),discomfort,sickness,anddriesoutnasalmembranes.

Over-humidifyingtheaircancausemoldandwallpapertopeel.

Q.Why do I need a humidifier when I can just open my window?

A. Themoisturelevelwithintheoutsideairisnothighenoughtohumidifyaroom.Thecoldertheairthelessmoistureitiscapabletohold,andthemoretheairisheatedupthepercentageofrelativehumidityislower.Relativehumiditymeanstheamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated.Thedifferenceishigherbetweenoutsideandinsidetemperatures;morehumidificationisneededbecauseofthedryairintheroom.

Q.Where should I place my humidifier?A. Theunitshouldbefree-standingandnotclosetoa

wall,window,door,orthermalbridgesothatairmaycirculatearoundtheunit.

Ultrasonic Frequent Questions

Q.Why does it say open/close on the demineralization cartridge cap?

A. Thesedirectionsarethereincaseyoudecidetousetherefilloptiontoreplacethegranules;thepurposeisforhowtoopenandclosethecap.Ifyoudidopenthecapbeforeplacingitinthewatertank,youwillmostlikelynoticethattherearegranulesinthewatertankandthebaseoftheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!

Q. I just replaced my cartridge, and the contents and water in the base has turned a blue-green color.

A. Thissometimesoccurswhenthecartridge,oreventhegranules,arereplaced.Thisdoesnotoccurwithallreplacementcartridgesorgranules,andisareactionofwatercontentandtheUltrasonicvibrations.Thisisnotanindicatortoreplacethecartridge.

Q.There is no fill-line on the water tank, how far may I fill it up?

A. Thereisnofilllineonthewatertank,anditmaybefilledallthewaytothetop.

Q.What is the purpose of the demineralization cartridge (DMC)?

A. TheDMCremovesmineralsfromthewatertopreventwhitedust.Thecontentsofthecartridgeneedtobesoakedfor24hrspriortofirstusingtheunitsothattheymayfullyexpandandremovemineralsfromthewater.ThecontentsoftheDMChavealifeof2–3months.Thecartridgemayneedtobereplacedmoreoftendependingonwaterhardnessandhowoftentheunitisused.AnindicationofwhentheDMCneedstobechangedcanbewhitedustorreducedamountofmistoutput.

Q. Is it ok to use distilled water with the unit?A. Forbestresultswithyourultrasonichumidifieruse

distilledorreverse-osmosiswaterandremovethedemineralizationcartridge.

Q. I just replaced the contents of the cartridge and now have granules everywhere.

A. First,makesuretherearenogranulesinthemiddleofthecartridge.PlacinggranulesinthemiddleoftheDMCallowsthemtoescapeintheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!

Q. The directions tell me not to place the unit directly on the floor, why do I have to elevate the unit?

A.Theideawiththisunitistoallowonetoforcehumidityintotheair.Becauseofthis,thecarpetingorwoodfloorsurroundingtheunitmaybecomedamp.Iftheunitis

Page 18: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

18

en placedatleast3feetoffthefloor,themistwillhavetheopportunitytoevaporatebeforehittingthefloor.

Q. Water does not go into the tank.A.Inordertofillthetank,itmustbeturnedupsidedown.

Thecartridgeisplacedonthewatertankcap.Donotpourwaterinthetubewhichisthemistoutlet.

Q. White dust is emitted from the unitA.Whitedustparticlesaremineralsthatarebrokenupin

tinypiecesbytheultrasonicprocess. Solve the problem:•Soakthedemineralizationcartridgeinabowlofwater

foraminimumof24hours.Ifthecartridgeissoakedinthewatertank,thewaterinthetankandthebaseneedstobereplacedbeforeusingtheunit.

•Exchangethedemineralizationcartridgeafter1-2monthswhenyouuseveryhardwater(forsofterwaterafter2-3months).Nomatterhowhardyourwateris,exchangethecartridgeattheverylatestafter6months.

•Don’tusewaterfromapre-installedwatersoftener,orsodiuminsteadofcalciumwillbeemittedfromtheunit.Usedistilledwaterinsteadandremovethedemi-neralizationcartridge.

•Forveryhardwaterareasuseonlydistilledwaterandremovethedemineralizationcartridge.

•UseReverse-Osmosiswater(R-Owater)insteadofdis-tilledwaterandremovethedemineralizationcartridge.

•Cleaning light is illuminated (digital models) Switchofftheunitandunplugit.Emptythewaterin

thebase.Rinsethebasewithhot/cleanwater.Donotsubmergethebase!Visuallyinspectthebasefordirtormineralbuildup.Ifsoftwaterisused,decalcifytheunitevery4weekswithEZCalissuggested.Ifhardwaterisusedtheunitshouldbedecalcifiedevery2weeks.Donotforgettoresetthecleanlightafterresettingtheunit.

Q.Reset cleaning light (digital models)A. Thecleaninglightdoesnotautomaticallyreset.Hold

downthepowerbutton(buttonAininstructionmanual)untilthelightstopsflashing.Thelightautomaticallycomesonapprox.after14daysofpluggingintheunit.

Q.The hygrometer on unit reads a different humidity level than external hygrometer.

A. Notallhygrometersarecalibratedthesame,andmostareoffby+/-5%.Plusthehumiditylevelisnotthesameinthewholeroom.Theaircirculationisdifferentineverycorneroftheroom.Theunitshouldnotbeplacednearaheatingventoraradiatorastheheatwillabsorballofthemoisture.

Q.Humidity level is not changing or does not reach the desired humidity level.

A. Ifthewatertankneedsrefillingmorethanonceperday,theunitisworkingproperlyandtheclimaticconditionintheroomhasaninfluenceonthehumidity.

Reasons for low humidity level:•aircirculationisveryhigh(airisfullyexchanged

severaltimesperday–thehumidifierneedstostartsitsworkfromscratch)

• insulationofhome(seeaircirculation)•openspacewithhighceilings(notonlythefootageof

theroomcountsbutalsotheheight)–high-risebuil-dingsrequiremorehumidification.

•openwindows–workssimilartoaircirculation(ifitisverycoldoutsidedon’topenthewindowmorethan2timesperdayfor3minutes)

•bigdifferencebetweenoutsidetemperatureandinsidetemperature–thecoldertheairthelessmoistureitiscapabletoholdandthemoretheairisheateduptheloweristhepercentageofrelativehumidity(=theamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated)

•positionoftheunit-ifitisplacedclosetoadoor,windoworairvent.Thisincreasestheaircirculation.

Q.Tank is leakingA. Checkifthereareanyhairlinecracks.Droppedunitsor

watertanksthatarecrackedwillnotbecoveredunderthewarranty.Pleasecontacttheretailertheunitwaspurchasedfromincaseyourunitarrivesdamaged.

Q.Placing the face in the mistA. Itisnotrecommendedthatanybodyplacestheirface

inthemist.Itisanelectricalproductandshouldnotbeplayedwith.

Q.No mist / unit is not working / empty indicator keeps flashing

A. Fillupthewatertank.Checkifwaterisflowingthroughthedemineralizationcartridge(attachedtothewatertankcap).Ifthewatertankisfullbutthereisonlylittlewaterinthebaseitindicatesthatthewaterisnowflowingthroughthedemineralizationcartridge.

•Waitfor15minutestoallowthemisttocomeoutoftheunit.

• Iftheunitisnotworkingandtheemptylightisnotflashingyoumighthavesetthedesiredhumiditytoolowandthecurrenthumiditylevelintheroomishigher.Thatiswhytheunitswitchesoffautomatically.

• Iftheemptyindicatorkeepsflashingandthetankisfull,thewaterisnotflowingthroughthecartridge.Exchangethecartridgeorthegranulesinthecartridgeafter2-3months,inareaswithhardwaterexchangethecartridgeafter1-2months.However,thedemi-neralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore

• Ifthegranulesarenew,seethefollowinginstructions:•Makesurethecartridgeand/orgranulesweresoaked

for24hours,drygranulestakeevenlongerforwatertofilterthroughthecartridgeandintothebase.Next,pleaseremove2tablespoonsofgranulesfromthecartridge,andthrowthemaway.Whentherearetoomanygranulesinthecartridgeitdoesnotallowwatertoflowfromthetanktothebase.

Page 19: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

19

enQ.Water tank cap is too tight to unscrewA. Thiscouldbeacauseoftheairpressurewithinthe

watertank.Depressthespringonthebottomofthewatertankcaptoreleaseairfromthewatertank.Continuetodothisuntilyouareabletounscrewthewatertankcap.

Q.Unit is running intermittently.A. Howlonghasitbeensincethecontentsofthe

cartridgewerereplaced?If2-3monthshavepassed,itistimetoreplacethecontentsofthecartridge.Howeverthedemineralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.

• Ifthecontentsofthecartridgewerejustreplacedthereareprobablytoomanygranulesinthecartridge.Re-move2tablespoonsofgranulesfromthecartridge.

Accessories

Q.Do I need to keep any parts before I replace the demineralization cartridge?

A. Yes,alwayskeepthewatertankcap(thisisthepiecethatattachesthedemineralizationcartridgetothewatertank).

Q.What is the Hydro Stick and how long is it good for?

A.TheAIR-O-SWISSHydroStickkeepshumidifiersoperatingattheirhighestlevelbetweenrecommendedcleanings*.Goodforoneyear,theHydroStickensuresthehumidifier’sfunctionalitywhileprovidingfreshhumidificationperformance.Itneedstobereplacedonceayear.

*Refertothecleaninginstructionsinthismanual.

Q.Placement of the Hydro StickA.Pleaseseepicture28forinstructions.

Q.Replacement reminderA.IneachHydroStickboxandonallthenewproducts

thereisaHydroSticklifecycleindicator.ChecktheboxofthemonthwhenstartingtousetheHydroStickandwritetheyearonthelineindicated.Exchangeitafteroneyear.

Q.What is EZCal?A. ThereisasamplepacketofEZCalincludedinthe

packagingofyourhumidifier.EZCalisusedforcleaninganddescalinganyoftheAIR-O-SWISShumidifiersandcleansmineralbuild-up.EZCalistheonlyrecommen-dedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagetheproduct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.Itcanalsobeusedforotherhumidi-fierbrands.ThoroughlyrinsethebasewithtapwaterandmakesurenoEZCalresiduesremaininthebase!EZCalisavailableatselectedretailstoresandonlinewww.airoswiss.net.

Page 20: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

20

en

Page 21: AOS 7142 - 3Gorillas.com · other way. • Repairs of electrical appliances are only to be made by qualified service engineers (4). Improper repair work can cause considerable danger

Please check our website www.airoswiss.net for further information.

AIR-O-SWISS is a registered trademark of PLASTON Group, Switzerland 3373

9-02