aos 7142 - bevochtiger u7142.pdf · 7142! did you know that dry room air: • causes the membranes...

18
AOS 7142 PLEASE READ AND SAVE ALL INSTRUCTIONS!

Upload: others

Post on 04-Aug-2020

5 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

AOS 7142

PLEASE READ AND SAVEALL INSTRUCTIONS!

Page 2: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging
Page 3: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

enInstructions for use

Page 4: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

en

Important safety instructions• Priortousingtheappliance,readthroughthein­

structionsforcompleteuseandretaininasafeplaceforlaterreference.

• WARNING–OnlyusetheUltrasonicindoorsandwithinthespecifiedtechnicaldata.Improperusecanbehazardousforthehealthandleadtocriticalinjury.

• Connecttheunitonlytoalternatingcurrentwithvoltageaccordingtotheratinglabel.

• Childrencannotrecognizethehazardsassociatedwiththeusageofelectricalappliances.Forthisreason,alwayssupervisechildrenwhentheyarenearthehumidifier(image1).

• Neverusetheapplianceifthereisanydamagetotheapplianceorcable(2),aftermalfunction,aftertheappliancehasbeendropped(3)ordamagedinanyotherway.

• Repairsofelectricalappliancesareonlytobemadebyqualifiedserviceengineers(4).Improperrepairworkcancauseconsiderabledangertotheuser.

• Placethehumidifieronadry,levelsurface(5).• Do not place the appliance directly on the flooror

nexttoaheatingvent(6).• Ifthemistcomesincontactwiththefloorpriorto

evaporating,thefloorsurfacecanbecomedamaged.Wedonotacceptanyliabilityfordamagesinthecaseofincorrectplacementoftheunit.

• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chestofdrawers,etc.

• Placeappliancewhereitisnoteasilyknockedover(8).• Alwaysunplugwhennotinuse.• Onlyoperatethehumidifierwhenitiscompletely

assembled.• ALWAYSunplugbeforeremoving/filling/emptyingthe

watertank,beforecleaning/maintaining,assembling/dismantlingofindividualpartsandbeforemovingtheappliance.

• Donottouchthewaterinthebaseduringoperationbecauseofhighfrequencyvibrationsinthewater.

• Donotrunpowercordsundercarpets,anddonotco­verwiththrowrugs.Arrangecordsothatitwillnotbetrippedover.

• Neverpulltheplugfromtheoutletbythecableorwithwethands.

• Donotusetheappliancewherecombustiblegasesorvaporsarepresent.

• Donotexposetheappliancetorain,orusenearwater,inabathroom,laundryareaorotherdamplocation.

• Thisunitmustbeusedinitsuprightposition.• Donotallowforeignobjectstoenterventilationor

exhaustopeningasthismaycauseelectricshockordamagetotheappliance.Donotblockairoutletsorintakes.

• Donotpourwaterintothemistoutletoftheappliance.• Thisappliancehasapolarizedplug(onebladeiswider

thantheother).Toreduceriskofshock,thisplugisintendedtofitinapolarizedoutletonlyoneway.Iftheplugdoesnotfitfullyintheoutlet,reversetheplug.Ifitstilldoesnotfit,contactaqualifiedelectrician.DONOTattempttodefeatthissafetyfeature.

• Aloosefitbetweentheplug(receptacle)andtheACoutletmaycauseoverheatingandadistortionoftheplug.Contactaqualifiedelectriciantoreplacelooseorwornreceptacles.

• Donotsit,standorplaceanyheavyobjectsontheappliance.

• Donotsubmergethemainbodyinwaterorotherliquids.

• Disconnectpowersupplybeforeservicing.• Personswhoarenotfamiliarwiththeinstructions

foruse,aswellaschildrenandpersonsundertheinfluenceofmedication,alcohol,ordrugsarenotpermittedtooperatetheappliance,orareonlyper­mittedtooperateitundersupervision.

• Theuseofwateradditives,suchasethereal/essentialoils,fragrances,eucalyptus,waterconditionersetc.,damagesthetankmaterialandasaconsequencethewholeunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.

• Remark:Neitherhumansnoranimalscanhearthehighfrequencyvibrations.

PLEASE READ AND SAVE ALL THESE INSTRUCTIONS!

Page 5: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

en

1

1ft

4ft

3ft

7

96

2

� en

8

Page 6: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

6

en ForewordCongratulations on choosing theUltrasonicAIR­O­SWISS7142!Didyouknowthatdryroomair:

• Causesthemembranesinyourrespiratorysystemtodryout,andalsocauseschappedlipsandstingingeyes?

• Encouragesinfectionsandillnessesofrespiratorysystem?

• Causesweariness,tirednessandpoorconcentration?• Stresseshouseholdpetsandhouseplants?• Encouragestheformationofdustandtheelectrostatic

chargingoftextilesmadeofsyntheticfibers,carpetsandplasticflooring?

• Damagesfurnishingsmadeofwoodandparquet?• Detunesmusicalinstruments?

General informationAcomfortableatmosphere indoors is reachedwitha re­lativehumidity levelbetween40and60%.Yourhumidi­fier automatically controls the humidity level accordingtodesiredsetting. If theair is toodry, thehumidifierwillautomaticallyswitchon.Assoonasthedesiredhumiditylevelisreached,itwillswitchoff.

Unpacking• Carefullyremovethehumidifierfromthebox.Place

yourhandsunderneaththeproducttopullitoutofthebox(10).

• Warning:Donottaketheunitoutoftheboxbypullinguponthetankhandle­basemayfallandwillbeda­maged(11).

•Warning:Themistoutletispackedinaredbaginsidetheboxinsert.Makesurethatyouremovethemistoutletfromthepackaging(12).

•Removetheplasticbagfromthehumidifier.• Observetheinformationgivenontheratingplateabout

thevoltage.•Thereisaprotectivelabelonthecontrolpanelinorder

toprotectthesurface.Pleaseremoveitasshownbe­forethefirstuse(13).

• Usetheoriginalpackagingforstoringtheapplianceifyoudonotusethehumidifierallyearround.

10

11

12

1�

Page 7: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

7

enSetting upFindingtheideallocationforyourunit:• Donotplacethehumidifierdirectlynexttoaheating

ventoronafloorwithfloorheating.Themoistureofthemistcandamagethefloorsurface(6)(seeSafetyInstructions).

• Theunitshouldbeplacedinanelevatedposition(7),e.g.onatable,chest,etc.atleast3ftoffthefloor.

• Themistoutletmustnotbepointeddirectlyatplants,furniture,orotherobjects(14).Keepdistanceofatleast20inches(50cm).

• Soakthedemineralizationcartridgeinawaterbath24hoursbeforeusingit(15).Theresinhastoabsorbwatertoreachhighperformance.Ifitissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.

• Onaveragethedemineralizationcartridgeshouldbereplacedevery2–3monthsdependingonyourwaterhardness.Someareasmayneedtoreplacethecart­ridgesooner,somemaylastlonger.Thecartridgemustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.

See«Replacementofthedemineralizationcartridge».• Readtheinstructionsunder«FillingtheTank»for

addingwaterinthehumidifier(16and17).• Placethewatertankontothebase.• Inserttheplugintothesocketandswitchonthe

applianceusingtheon/offdial(20).• About10to15minutesafteritisswitchedonthede­

vicewillreachitsfulloutputlevel.• Makesurethatthecableisnotpinchedanywhere(9).

Donotoperatethehumidifierifthecableisdamaged(2).

Description of the appliance

Mistoutlet(rotating)

Evaporationchamber

Watertank

Demineralizationcartridge

Mainbody

Controlpanel

Watertankcap

Brush

Airinlet

Membrane

Nebulizerspace

IonicSilverStick®

1�

24 h

1�

Page 8: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

8

en

18

19

17 20

16Filling the tankAlways unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!

Do not operate the humidifier when the water tank isempty!Whenthewaterreachestheminimumlevel,theunitswitchesoffthenebulizerfunctionautomatically.Theredlightcomesonindicatingtankisempty.

•Removethewatertankfromthebaseandunscrewthewatertankcap(16).Caution:themistoutletisloose!

• Makesurethatnoforeignobjectsareinthewatertank.

• Fillthetankwithclean,coldwaterfromthetap(17).Closethecapofthewatertanksecurely,placethewa­tertankontothebase(18).Thewaterisnowrunningfromthetankintothebase.

• Donotpourwaterintothemistoutletoftheappliance(19).

• Inserttheplugintothesocketandswitchontheapplianceusingtheon/offdial(20).Theredemptyindicatorlightmaystayilluminatedforsomesecondsuntilthebaseisfilledwithwater.Thenthegreenlightcomeson.

Use of additivesWater additives (ethereal/essential oils, fragrances,eucalyptus, water conditioners, etc.) must not be used!Evenasmallamountcancausecracksinthematerial.Thematerialisn’tmadefortheuseofsuchadditives.Onedropisenoughtodamagethetankandasaconsequencetheunit.Anyuseofsuchadditiveswillvoidthemanufacturer’swarranty.

Page 9: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

9

en

A) On/Off dialYoucanswitchtheunitonoroffbypressingbuttonA.Thisbuttonisalsousedtoresetthecleaningindicatorlight(byholdingdown).

B) Hygrostat (setting the humidity level)By pressing multi­functional button B (vertical) you cansetthedesiredhumiditylevelin%.Arelativehumidityofbetween40and60% is recommended.Theaccuracyofmeasurementis+/­5%.Theunitwillswitchoffwhenthemoisturelevelexceedsthedesiredsetting.Duringselectionthetargetvalueisdisplayed.Thedisplaywillautomaticallyshowthecurrentvalueafterafewseconds.

Operation 71�2 C) TimerUsing multi­functional button C (horizontal), the opera­tiontimecanbesetadjustablebetween1and8hours.Symbol Gshowstheoperatingperiodthathasbeenset(1h/2h/3h/4h/5h/6h/7h/8h).Thedisplaywillautomaticallyshowthecurrentvalueafterafewseconds.

D) Mist output (regulating mist output)ByrepeatedlypressingbuttonDyoucancontrolthemistoutput.TheLO/ME/HIdisplay(symbol H)showswhichofthethreelevels(low/medium/high)youhaveselected.

E) Operation with pre-heating (warm mist)ButtonEisusedforswitchingthepre­heatingonandoff(symbol Ilightsup).Asaresult,thewaterispre­heatedtoa temperatureof176°F (80°C) beforeenteringthenebulizerspace.Ittakesapprox.10to15minutesforthewater inthebasetowarmup.Themistnowleavesthehumidifieratapleasanttemperatureof104°F(40°C).Theadvantageofthisisthattheroomtemperaturedoesnotdropand, inaddition, itsignificantly improvesthewaterqualitymaintenance.

F) Automatic mode and Sleep modeTheautomaticandsleepmodescanbeactivatedbypres­singbuttonF.Bypressingthebuttononce,theautomaticfunctionisswitchedon(symbol Jappearsonthedisplay),maintainingtheoptimumhumiditysubjecttothetempera­ture.Controltakesplacebymeansofoutputquantityandpre­settargetvalue.Ifthesleepfunctionisswitchedon(thesymbol Kappearsonthedisplay),thetargethumidityis60%;theoperationtimeisautomaticallysetat6hours;theheatingisswitchedon.Inaddition,theoutputquantityisalsocontrolledsubject to thedifferencebetween thetargetvalueandtheactualvalue.The Timer cannot be changed in either mode. If otherbuttonsarepressed,theunitwillnolongerbeinautoorsleepmode.

J

G H

AF

DE

BC

K L I M

L) Empty indicatorThewater level iseasytosee,thankstothetransparentwatertank.Theappliancealsoalertsyouwhenthewatertankisempty.Theemptyindicatorisilluminated(symbolL).Pleasereadthechapter«Fillingthetank»formoreinforma­tion.TheSymbolLmaystayilluminatedforsomesecondswitharefilledtankuntilthebaseisfilledwithwater.

M) Cleaning indicatorIfsymbolMand«CLEAN»appearonthedisplay,theappli­anceshouldbecleanedasrecommendedbythemanufac­turer.Thissymbolcomesonautomaticallyevery2weeks,dependingonthelevelofuse.The display can be reset by holding down button A until the light disappears.

Page 10: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

10

en

ACIDACID

30 min

140°F / 60°C

2�

2622

21 2�Cleaning/Maintenance Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!

Caution – risk of electric shock and damage of the product!

• Switchofftheapplianceandunplugitfromthesocketbeforecleaningit(21).

• Cleanthewatertankandthebaseregularly.Usewateronly,nodetergents(22).

• UseAIR­O­SWISSEZCalcustomcleaninganddesca­lingagentonlytoremovedepositsfromthemembraneregularly(23and24).ThereisasampleofEZCalin­cludedinthepackagingofyourhumidifier.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.DoNOTruntheunitwhenusingEZCal.Thiscancausedamagetothepro­ductandvoidsthewarranty.ThoroughlyrinsethebasewithpotablewaterafterusingEZCalandmakesurenoEZCalresiduesremaininthebase.

2� 27

Page 11: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

11

enEZCalfromAIR­O­SWISSistheonlyrecommen­dedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagetheproduct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.

• Makesuremainbodyisneversubmergedinwater(25)!

• Thecleaningindicatorstillappearsonthedisplayaftercleaning.ToresetitholddowntheON/OFFbuttonuntilthecleanlightstopsflashing.

• Cleantheinnerpartswithasoftcloth.Donotuseanysolventsoraggressivecleaningagentstocleantheappliance(26).

• Onlyusethebrushtocleanthemembrane.Thisshouldbedoneonceaweek.Onlyusethesoft­bristleportionofthebrush(27).

• Changethewaterinthetankatleastonceaweekifwaterisstandingformorethanaweek.

Water quality maintenanceTheIonicSilverStick®(28)keepsthewaterfreeofmicro­bialgrowth.Theanti­microbialactionofsilverisused.TheIonicSilverStick(ISS)releasessilverionsinthewateroveralongperiodoftime(approx.oneyear).It‘sself­regulatingandmaintenance­free.Lookatpicture28forthepositionoftheISSinthebasepartoftheunit.Donottouchthewaterinthebaseduringoperation!Switchofftheunitfirst.Contactyourlocalretailerorcheckourwebsitewww.airoswiss.netforreorderinformation.TheIonicSilverStick®comeswithametallicclipwhichcanberemovedfortheplacementinthisproducttype.

Lifecycle IndicatorYourappliancecomeswithalifecycleindicatorforchangingtheIonicSilverStick®.ToremindyourselfofwhenyouputtheISSintooperation,pleasecrossthecurrentmonthonthestampandwritethecurrentyearonthelineprovided(29).

28

29

Page 12: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

12

en �0

�1

•Removetheplasticcupandthepinkstyrofoampiecefromthecartridge(38)andretainforfutureuse(therefillresinconsistsof3refillbags)(39).

•Closethecartridge(40).•Soakthedemineralizationcartridgeinawaterbath 24hoursbeforeusingit(43).Theresinhastoabsorb

watertoreachhighperformance.Ifitissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.

•Screwthecartridgeonthewatertankcap(44).•Screwthecartridgeonthebottomsideofthewater

tank,putthetankonthemainbody(45).

Placinggranules in thecenterof thecartridgeallowsthemtoescapeintheunitortoclogtheunit.Theunitwillnolongeroperateproperlyandthegranulesneedtobecleanedoutthoroughly.

Option B: replace the whole cartridge•Removethewatertankfromthebaseandunscrewthe

watertankcap(30).Caution:themistoutletisloose!•Thedemineralizationcartridgeisattachedtothetank

cap.Unscrewthecartridgefromthecapbyturningitcounter­clockwise(31).Important:doNOTdisposeofthewatertankcap!

• Throwthewholecartridgeintothewaste(41).•Unpackthenewcartridge(42).•Soakthedemineralizationcartridgeinawaterbath

24hoursbeforeusingit(43).Theresinhastoabsorbwatertoreachhighperformance.Ifitissoakedinthetank,makesuretoexchangethewaterandemptythewaterfromthebasebeforeusingthehumidifier.

•Screwthecartridgeonthewatertankcap(44).Closetankcapwellandplacethetankonthemainbody(45).

Replacement of the demineralization cartridge

Always unplug the unit before removing thewatertank.Donottouchthewaterinthebaseduringoperation!

The water tank is equipped with a demineralization cart­ridge.Thiscartridgehastobereplacedevery2–3months.Ifthewaterisveryhard,itmaybenecessarytoreplacethecartridgeearlier.Whitedustaroundthedeviceisasuresignthat thecartridgeneeds replacing.Pleasenotewhitedustisnotharmful.Ifwhiteresiduestillformsaroundthedeviceafteranewcartridgehasbeeninserted,pleasemakesurethatthewateryouareusingisuntreated.Ifthewaterflowsthroughadecalcificationsystem–suchasanionexchanger–(sodiumisaddedtoremovecalcium)inthebuildingbeforeitisusedinthehumidifier,saltcanprecipitateaswhitedustaroundthedevice.Thedemineralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.

Option A: replace the resin•Removethewatertankfromthebaseandunscrewthe

watertankcap(30).Caution:themistoutletisloose!•Thedemineralizationcartridgeisattachedtothetank

cap.Unscrewthecartridgefromthecapbyturningitcounter­clockwise(31).Important:doNOTdisposeofthewatertankcap!

•Openthecartridge(32).•Throwthecontentintothewaste(Attention!Disposed

resincanmakethefloorslippery!)(33).•Placetheenclosedpinkstyrofoampieceinthecenter

ofthecartridge.Donotpushittothebottomasitwillbedifficulttoremoveafterwards(34).

•Pourthecontentsofonerefillresinbagintotheplasticcupthatisincludedwiththerefillresinpackaging(35).

•Placetheemptycartridgewiththepluginthecenterontotheplasticcup(36).

•Turntheplasticcupandcartridgeoverandshakeuntilallresinisinthecartridge(37).

�2 ��

Page 13: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

1�

en

��

��

�� ��

�6

�7

�8

�9

�1

24 h

��

�0

�2

Page 14: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

1�

en Storing the appliance for extended periodsCleantheapplianceasdescribedearlierandallowtodrythoroughly.Preferablystoretheapplianceinitsoriginalbox,inadryplaceawayfromhightemperatures.

Legal noticeThehumidifieriscUL­listed.Subject to technicalchange.The instructions foruseareprotectedbycopyright©PLASTONAG.

AccessoriesContact your local retailer or check our website www.airoswiss.netforre­orderinformation.

Customer ServiceCustomerService(USA)1­800­336­0326www.airoswiss.net

Technical data

Electricalvoltage 120V/60Hz

Powerconsumptionupto 45W/(140W*)

Humidityoutputupto 3.5gallons/24h*

Suitableforroomsupto 860sqft/80m2

Dimensions(LxWxH) 9.8x11.0x17.3in 25x28x44cm

Weight(empty) 8.8lbs/4kg

Accessories Demineralizationcartridge IonicSilverStick®

*whenusedwithpre­heatingto176°F(80°C)

Trouble shooting

Problem Possible cause What to do

Unitdoesnotoperate Powercablenotpluggedin Pluginpowercable

Nowaterinthetank(Empty­lightred) Filltankwithwaterandwait10min.

Nomistoutput Unitneedscleaning DescalethewaterbaseusingEZCal

DMCexhausted Replacecartridgeorgranules

DMCoverfilledwithgranules Takeout2tablespoonsofgranulesandthrow themaway

Weakmistoutput Watertemperaturetoolow Setmistoutputtomaximum,after15min. thehumidifierwillworkproperlyagain

Mineraldepositsonmembrane CleanmembraneusingEZCalandbrush

Unitrunningintermittently

Whitedustaroundthehumidifier Demineralizationcartridgeexhausted Replacedemineralizationcartridgeorresin

Page 15: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

1�

enGeneral Humidifier Questions

Q.Why isn’t there enough moisture in my room?A. Howoftendoyouruntheunit?Iftheunitisonlyrunat

night,thenduringthedaythemoisturelevelwilldropifmoistureisnotconstantlyaddedtotheair.

Q.Do you leave your door open or closed when the unit is running?

A. a) Byleavingthedooropen,thisallowsmoisturetoleavetheroomandgointootherareasofthehouse.Ifyouwouldlikethemoisturetostaywithinonespecificroomyoushouldconsiderclosingthedoorwhiletheunitisrunning.

A. b) Wood,leather,carpet,curtains,andothertypesoffabricsoakupalotofmoisture,thusnotleavingenoughmoisturefortheair.Ifthewindowisleftopen,thenthisallowsmoisturetoescapetheroom.Anotherfactorisalotoftimestheunitisplacednexttoaheatingdevice.Theideaisthattheairblowingintotheroomwillquicklyplacemoisturearoundtheroom.Unfortunately,thisconceptdoesnotworkbecausethehotaircomingoutofaventwillsoakupmostofthemoisture,andnoneoftheairwithintheroomwillreceiveany.

Q.How much moisture do I need in my room?A. Suggestedhumiditylevelsarebetween40–60%.

Q.What are the effects of too little or too much humidity?

A. Dryaircancausedryskin,staticelectricity,outoftunemusicalinstruments,increasedlevelsofdust(dryaircausesdusttorise),damagetowoodenobjects(dryoutandeventuallycracksappear),discomfort,sick­ness,anddriesoutnasalmembranes.

Over­humidifyingtheaircancausemoldandwallpapertopeel.

Q.Why do I need a humidifier when I can just open my window?

A. Themoisturelevelwithintheoutsideairisnothighenoughtohumidifyaroom.Thecoldertheairthelessmoistureitiscapabletohold,andthemoretheairisheatedupthepercentageofrelativehumidityislower.Relativehumiditymeanstheamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated.Thedifferenceishigherbetweenoutsideandinsidetemperatures;morehumidificationisneededbecauseofthedryairintheroom.

Q.Where should I place my humidifier?A. Theunitshouldbefree­standingandnotclosetoa

wall,window,door,orthermalbridgesothatairmaycirculatearoundtheunit.

Ultrasonic Frequent Questions

Q.Why does it say open/close on the demineralization cartridge cap?

A. Thosedirectionsarethereincaseyoudecidetousetherefilloptiontoreplacethegranules;thepurposeisforhowtoopenandclosethecap.Ifyoudidopenthecapbeforeplacingitinthewatertank,youwillmostlikelynoticethattherearegranulesinthewatertankandthebaseoftheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!

Q. I just replaced my cartridge, and the contents and water in the base has turned a blue-green color.

A. Thissometimesoccurswhenthecartridge,oreventhegranules,arereplaced.Thisdoesnotoccurwithallreplacementcartridgesorgranules,andisareactionofwatercontentandtheUltrasonicvibrations.Thisisnotanindicatortoreplacethecartridge.

Q.There is no fill-line on the water tank, how far may I fill it up?

A. Thereisnofilllineonthewatertank,anditmaybefilledallthewaytothetop.

Q.What is the purpose of the demineralization cart-ridge (DMC)?

A. TheDMCremovesmineralsfromthewatertopreventwhitedust.Thecontentsofthecartridgeneedtobeso­akedfor24hrspriortofirstusingtheunitsothattheymayfullyexpandandremovemineralsfromthewater.ThecontentsoftheDMChavealifeof2–3months.Thecartridgemayneedtobereplacedmoreoftendependingonwaterhardnessandhowoftentheunitisused.AnindicationofwhentheDMCneedstobechangedcanbewhitedustorreducedamountofmistoutput.

Q. Is it ok to use distilled water with the unit?A. Forbestresultswithyourultrasonichumidifieruse

distilledorreverse­osmosiswaterandremovethedemineralizationcartridge.

Q. I just replaced the contents of the cartridge and now have granules everywhere.

A. First,makesuretherearenogranulesinthemiddleofthecartridge.PlacinggranulesinthemiddleoftheDMCallowsthemtoescapeintheunit.Immediatelyturnofftheunit,andemptythewateroutofthebaseandthewatertank.Beginremovingallgranulesfrombaseandwatertank.Usebrushtocleanaroundmembrane.Caution:Donotdisposeofgranulesinsink!Usedgranulesmustgoinwaste!

Q. The directions tell me not to place the unit directly on the floor, why do I have to elevate the unit?

A.Theideawiththisunitistoallowonetoforcehumidityintotheair.Becauseofthis,thecarpetingorwoodfloorsurroundingtheunitmaybecomedamp.Iftheunitis

Page 16: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

16

en placedatleast3feetoffthefloor,themistwillhavetheopportunitytoevaporatebeforehittingthefloor.

Q. Water does not go into the tank.A.Inordertofillthetank,itmustbeturnedupsidedown.

Thecartridgeisplacedonthewatertankcap.Donotpourwaterinthetubewhichisthemistoutlet.

Q. White dust is emitted from the unitA.Whitedustparticlesaremineralsthatarebrokenupin

tinypiecesbytheultrasonicprocess. Solve the problem:•Soakthedemineralizationcartridgeinabowlofwater

foraminimumof24hours.Ifthecartridgeissoakedinthewatertank,thewaterinthetankandthebaseneedstobereplacedbeforeusingtheunit.

•Exchangethedemineralizationcartridgeafter1­2monthswhenyouuseveryhardwater(forsofterwaterafter2­3months).Nomatterhowhardyourwateris,exchangethecartridgeattheverylatestafter6months.

•Don’tusewaterfromapre­installedwatersoftener,orsodiuminsteadofcalciumwillbeemittedfromtheunit.Usedistilledwaterinsteadandremovethedemi­neralizationcartridge.

•Forveryhardwaterareasuseonlydistilledwaterandremovethedemineralizationcartridge.

•UseReverse­Osmosiswater(R­Owater)insteadofdis­tilledwaterandremovethedemineralizationcartridge.

•Cleaning light is flashing (model 71��/71�2/71��) Switchofftheunitandunplugit.Emptythewaterin

thebase.Rinsethebasewithhot/cleanwater.Donotsubmergethebase!Visuallyinspectthebasefordirtormineralbuildup.Ifsoftwaterisuseddecalcifyingtheunitevery4weekswithEZCalissuggested.Ifhardwaterisusedtheunitshouldbedecalcifiedevery2weeks.Donotforgettoresetthecleanlightafterreset­tingtheunit.

Q.Reset cleaning light (model 71��/71�2/71��)A. Thecleaninglightdoesnotautomaticallyreset.Hold

downthepowerbutton(buttonAininstructionmanual)untilthelightstopsflashing.Thelightautomaticallycomesonapprox.after14daysofpluggingintheunit.

Q.The hygrometer on unit reads a different humidity level than external hygrometer.

A. Notallhygrometersarecalibratedthesame,andmostareoffby+/­5%.Plusthehumiditylevelisnotthesameinthewholeroom.Theaircirculationisdifferentineverycorneroftheroom.Theunitshouldnotbeplacednearaheatingventoraradiatorastheheatwillabsorballofthemoisture.

Q.Humidity level is not changing or does not reach the desired humidity level.

A. Ifthewatertankneedsrefillingmorethanonceperday,theunitisworkingproperlyandtheclimaticcon­ditionintheroomhasaninfluenceonthehumidity.

Reasons for low humidity level:•aircirculationisveryhigh(airisfullyexchangedse­

veraltimesperday–thehumidifierneedstostartsitsworkfromscratch)

• insulationofhome(seeaircirculation)•openspacewithhighceilings(notonlythefootageof

theroomcountsbutalsotheheight)–high­risebuil­dingsrequiremorehumidification.

•openwindows–workssimilartoaircirculation(ifitisverycoldoutsidedon’topenthewindowmorethan2timesperdayfor3minutes)

•bigdifferencebetweenoutsidetemperatureandinsidetemperature–thecoldertheairthelessmoistureitiscapabletoholdandthemoretheairisheateduptheloweristhepercentageofrelativehumidity(=theamountofwatervaporintheair,comparedtotheamounttheaircouldholdifitwastotallysaturated)

•positionoftheunit­ifitisplacedclosetoadoor,win­doworairvent.Thisincreasestheaircirculation.

Q.Tank is leakingA. Checkifthereareanyhairlinecracks.Droppedunitsor

watertanksthatarecrackedwillnotbecoveredunderthewarranty.Pleasecontacttheretailertheunitwaspurchasedfromincaseyourunitarrivesdamaged.

Q.Placing the face in the mistA. Itisnotrecommendedthatanybodyplacestheirface

inthemist.Itisanelectricalproductandshouldnotbeplayedwith.

Q.No mist / unit is not working / empty indicator keeps flashing

A. Fillupthewatertank.Checkifwaterisflowingthroughthedemineralizationcartridge(attachedtothewatertankcap).Ifthewatertankisfullbutthereisonlylittlewaterinthebaseitindicatesthatthewaterisnowflowingthroughthedemineralizationcartridge.

•Waitfor15minutestoallowthemisttocomeoutoftheunit.

• Iftheunitisnotworkingandtheemptylightisnotflashingyoumighthavesetthedesiredhumiditytoolowandthecurrenthumiditylevelintheroomishig­her.Thatiswhytheunitswitchesoffautomatically.

• Iftheemptyindicatorkeepsflashingandthetankisfull,thewaterisnotflowingthroughthecartridge.Exchangethecartridgeorthegranulesinthecartridgeafter2­3months,inareaswithhardwaterexchangethecartridgeafter1­2months.However,thedemi­neralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore

• Ifthegranulesarenew,seethefollowinginstructions:•Makesurethecartridgeand/orgranulesweresoaked

for24hours,drygranulestakeevenlongerforwatertofilterthroughthecartridgeandintothebase.Next,pleaseremove2tablespoonsofgranulesfromthecartridge,andthrowthemaway.Whentherearetoomanygranulesinthecartridgeitdoesnotallowwatertoflowfromthetanktothebase.

Page 17: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

17

enQ.Water tank cap is too tight to unscrewA. Thiscouldbeacauseoftheairpressurewithinthe

watertank.Depressthespringonthebottomofthewatertankcaptoreleaseairfromthewatertank.Continuetodothisuntilyouareabletounscrewthewatertankcap.

Q.Unit is running intermittently.A. Howlonghasitbeensincethecontentsofthecart­

ridgewerereplaced?If2­3monthshavepassed,itistimetoreplacethecontentsofthecartridge.Howeverthedemineralizationcartridgeandorthegranulesmustbeexchangedatthelatestafter6monthsortheunitdoesnotreachitsfullperformanceanymore.

• Ifthecontentsofthecartridgewerejustreplacedthereareprobablytoomanygranulesinthecartridge.Re­move2tablespoonsofgranulesfromthecartridge.

Accessories

Q.Do I need to keep any parts before I replace the demineralization cartridge?

A. Yes,alwayskeepthewatertankcap(thisisthepiecethatattachesthedemineralizationcartridgetothewatertank).

Q. Ionic Silver Stick® (water treatment) replacement reminder

A. IneachIonicSilverStick®(ISS)boxandonallthenewproductsthereisanISSlifecycleindicator.ChecktheboxofthemonthwhenstartingtousetheISSandwritetheyearonthelineindicated.Exchangeitafter12months.

Q.What is EZ Cal?A. ThereisasamplepacketofEZCalincludedinthe

packagingofyourhumidifier.EZCalisusedforcleaninganddescalinganyoftheAIR­O­SWISSproducts,andcleansmineralbuild­up.EZCalistheonlyrecommen­

dedcleaninganddescalingsolution.DoNOTuseanyothercleaningsolutionssinceitcandamagethepro­duct.AnyuseofcleaningsolutionsapartfromEZCalwillvoidthewarranty.Instructionsforusingareonthepacket.Onlyuse1packetfor32ozofwater.Donotchangetheratio.Itcanalsobeusedforanyotherhu­midifierbrand.DoNOTruntheunitwhenusingEZCal.Thiscancausedamagetotheproductandvoidsthewarranty.ThorouglyrinsethebasewithpotablewaterandmakesurenoEZCalresiduesremaininthebase!EZCalisavailableatselectedretailstores.

Page 18: AOS 7142 - bevochtiger U7142.pdf · 7142! Did you know that dry room air: • Causes the membranes in your respiratory system to dry out, and also causes chapped lips and stinging

AIR-O-SWISS is a brand name of PLASTON AG, Switzerland.

Please check our website www.airoswiss.net for further information.