anti surge cont slides 1 to 10
DESCRIPTION
Anti Surge Cont Slides 1 to 10TRANSCRIPT
![Page 1: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/1.jpg)
ANTI SURGE CONTROL
SYSTEM
BASIC CONCEPTS
![Page 2: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/2.jpg)
ISSUES FOR DISCUSSION
• Introduction to compressor control• Surge Phenomenon, causes and remedy• Basic ASC system• Challenging Issues
– Algorithms– Control responses– Advance control strategies– Quick response of control valve– Elimination of dead time and lag time
• Surge limit line, Distance between SLL and operating point• Performance control• Non-integrated System• Interacting Performance controller and ASC• Integrated system• Selection criteria for FMD and AS Valve
![Page 3: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/3.jpg)
PERFORMANCE CURVE OF COMPRESSOR
![Page 4: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/4.jpg)
SURGE
• Surge : Very fast process
• Order of
milliseconds
• Potential to cause huge damage and losses
![Page 5: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/5.jpg)
HOW SURGE DEVELOP ?
• Normal flow from higher pressure (P1) to lower pressure(P2)
• In Compressor gas flows from low suction pressure to high discharge pressure using external power.
• If discharge valve is closed discharge pressure (P2)increases. If P (P2 - P1 ) is more and power is not sufficient, flow will be reverse.
![Page 6: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/6.jpg)
SURGE PHENOMENON
• • Fig shows... how surge develops using a model of an air compressor pumping into a closed tank.
• Machine shutdown : no flow, no pressure
• Machine start:
• High flow, less pressure (E)
• Start press. build up, decrease flow( E to D to A)
• Reversal of flow at A and again at C, causing flow & pressure oscillations
![Page 7: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/7.jpg)
CAUSES FOR SURGE
• Discharge valve is closed• Suction flow decreases• Power increases• Change in gas composition
![Page 8: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/8.jpg)
SURGE CONTROL METHODS
• Vent discharge pressure
– Wastage of power
– Loss of material
– Hazards
• Recycle from discharge to suction
– Wastage of power
![Page 9: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/9.jpg)
ANTI-SURGE CONTROLLER
• KEY WORDS
– SURGE CONTROL LINE ( SCL )
– RECYCLE TRIP LINE ( RTL )
– SURGE LIMIT LINE ( SLL)
– SAFETY ON LINE ( SOL)
![Page 10: Anti Surge Cont Slides 1 to 10](https://reader036.vdocuments.mx/reader036/viewer/2022082315/545dafa3b0af9fdd168b468a/html5/thumbnails/10.jpg)
BASIC ANTI-SURGE CONTROL SYSTEM
• Anti surge controller protect the compressor against surge by opening the recycle valve
• opening the recycle valve lowers the resistance felt by compressor
• This takes compressor away from surge