ancillary elevation 5 - sjshire.wa.gov.au€¦ · ancillary accommodation project ... alfresco area...

2
Address - LOT 725 SELKIRK ROAD Suburb - SERPENTINE SHIRE OF SERPENTINE / JARRAHDALE PROPOSED DWELLING & ANCILLARY ACCOMMODATION Project Name Project Address Revision: D Job No. J002501 @A2 Client: LOUBSER NOTES THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATION, REPORTS, CONTRACTS AND DRAWINGS. Scale: Sheet Date: MAR 2016 Drn by: Chk by: Drawing: ANCILLARY FLOOR PLAN Suite 14, 755 Albany Hwy East Victoria Park WA 6101 Tel | +61 8 9355 5484 Web | www.approvalsbydesign.com.au © COPYRIGHT 720 2440x2170 SLIDERS 1372 x 1810 772 x 1210 OBS 1372 x 1810 2400x2410 SD 2400x930 OP'NG 720 2400x930 OP'NG 870 2400 HIGH BI-FOLD 820 TF 720 820 LINEN W.M. PROV 4,400 9,690 14,090 3,280 4,430 4,090 11,800 4,400 9,230 13,630 1,240 780 3,370 2,910 5,520 1,460 1,060 E-07 5 E-08 5 E-05 5 E-06 5 PTY WIR KITCHEN ENTRY RAKING CEILING RAKING CEILING LIVING / DINING BED2 GAMES MASTER BED ALFRESCO TIMBER DECK @-80mm VERANDAH 2 TIMBER DECK @-80 VERANDAH 1 TIMBER DECK @-80 ANCILLARY FLOOR AREA 119.93m² STORE AREA 8.75m² VERANDAH 1 AREA 25.99m² VERANDAH 2 & DECK AREA 50.30m² ALFRESCO AREA 15.51m² CARPORT AREA 37.21m² CARPORT TIMBER DECK @ -80 TIMBER DECK @ -80 TIMBER DECK @ -80 RAKING CEILING RAKING CEILING RAKING CEILING RAKING CEILING CEILING @2575 AFL CEILING @2575 AFL CEILING @2575 AFL CEILING @2575 AFL CEILING @2800 AFL CEILING @2800 AFL CEILING @2800 AFL CEILING @2800 AFL CEILING @2800 AFL RAKING CEILING RAKING CEILING 1286 x 970 OBS 820 TF 820 720 620 2x820 TF 1st 820 FLUMED R/HOOD T L'DRY ENS BATH RETAINING WALL REFER TO ENGINEER SPECS 6x180=1080 STEPS REFER TO ENGINEER SPECS C.L. 2560 ABOVE CARPORT FLOOR F.L. 1000mm EXPOSED TIMBER PERIMETER BEAM 125x125 TIMBER POST 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS RETAINING WALL REFER TO ENGINEER SPECS TIMBER STAIRS REFER TO ENGINEER SPECS TIMBER STEPS REFER TO ENGINEER SPECS STORE 3.22m x 3.50m 3.00m x 3.19m 2.88m x 3.19m 8.61m x 4.25m 3.50m x 4.43m 5.25m x 4.68m 5.25m x 4.74m 6.10m x 6.10m SHELVING SHELF & RAIL SHELF & RAIL bath & shr 125x125 TIMBER POST 125x125 TIMBER POST 125x125 TIMBER POST EXPOSED TIMBER PERIMETER BEAM EXPOSED TIMBER PERIMETER BEAM 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS 1.50m x 5.34m 2400 2400 2400 2560 2400 2650 2,800 3,340 250 624 F.L. 00c C.L. 2800 + PLATE GROUND LEVEL SHEET METAL ROOF @20°49' CEDAR BOARD CLADDING GROUND LEVEL 2560 3274 TIMBER STAIRS REFER TO ENGINEER SPECS 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS TIMBER FRAMED FLOOR CONSTRUCTION TO BE IN ACCORDANCE WITH A.S. 1884 REFER TO ENGINEER DETAILS FOR SUB FLOOR MEMBER SIZES & POSITION 125x125 TIMBER POST BI-FOLD DOOR BELOW 2400 AFL 2650 AFL 3274 AFL EXPOSED TIMBER PERIMETER BEAM 2400 2560 1028 2400 1627 3480 3590 1028 2,800 1,000 2,560 F.L. 00c C.L. 2800 + PLATE SHEET METAL ROOF @20°49' CEDAR BOARD CLADDING OBSCURED GLAZING GROUND LEVEL NATURAL GROUND LEVEL GROUND LEVEL TIMBER DECK @ -80 F.L. 00mm CARPORT F.L. CARPORT C.L. min 150mm SUBFLOOR VENTILATION AS PER NCC 2014 VOLUME 2 PART 3.4.1. SHEET METAL ROOF @20°49' NATURAL GROUND LEVEL 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS 125x125 TIMBER POST TIMBER STAIRS REFER TO ENGINEER SPECS EXPOSED TIMBER PERIMETER BEAM 6x180=1080 STEPS REFER TO ENGINEER SPECS RETAINING WALL REFER TO ENGINEER SPECS TIMBER FRAMED FLOOR CONSTRUCTION TO BE IN ACCORDANCE WITH A.S. 1884 REFER TO ENGINEER DETAILS FOR SUB FLOOR MEMBER SIZES & POSITION 2400 2560 0 2143 2400 2560 2400 1114 3480 3590 2,800 1,000 2,560 F.L. 00c C.L. 2800 + PLATE NATURAL GROUND LEVEL SHEET METAL ROOF @20°49' CEDAR BOARD CLADDING OBSCURED GLAZING GROUND LEVEL NATURAL GROUND LEVEL TIMBER DECK @ -80 F.L. 00mm CARPORT F.L. min 150mm SUBFLOOR VENTILATION AS PER NCC 2014 VOLUME 2 PART 3.4.1. CARPORT C.L. SHEET METAL ROOF @20°49' GROUND LEVEL 1050 HIGH BALUSTRADE AS SELECTED TO ENGINEER SPECS 125x125 TIMBER POST EXPOSED TIMBER PERIMETER BEAM 6x180=1080 STEPS REFER TO ENGINEER SPECS RETAINING WALL REFER TO ENGINEER SPECS TIMBER FRAMED FLOOR CONSTRUCTION TO BE IN ACCORDANCE WITH A.S. 1884 REFER TO ENGINEER DETAILS FOR SUB FLOOR MEMBER SIZES & POSITION 2400 2560 2143 0 2,800 3,332 F.L. 00c C.L. 2800 + PLATE GROUND LEVEL SHEET METAL ROOF @20°49' CEDAR BOARD CLADDING CEDAR BOARD CLADDING BARGE & CAPPING CEDAR BOARD INFILL min 150mm SUBFLOOR VENTILATION AS PER NCC 2014 VOLUME 2 PART 3.4.1. TIMBER DECK @ -80 125x125 TIMBER POST EXPOSED TIMBER PERIMETER BEAM TIMBER FRAMED FLOOR CONSTRUCTION TO BE IN ACCORDANCE WITH A.S. 1884 REFER TO ENGINEER DETAILS FOR SUB FLOOR MEMBER SIZES & POSITION 1:100 BC 2 of 4 1. ANCILLARY FLOORPLAN 1:100 E-05 ANCILLARY ELEVATION 5 1:100 E-06 ANCILLARY ELEVATION 6 1:100 E-08 ANCILLARY ELEVATION 8 1:100 E-07 ANCILLARY ELEVATION 7 1:100 OCM084.2.07.17

Upload: buiminh

Post on 21-Aug-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Address - LOT 725 SELKIRK ROADSuburb - SERPENTINESHIRE OF SERPENTINE / JARRAHDALE

PROPOSED DWELLING&

ANCILLARYACCOMMODATION

Project Name Project Address

Revision: DJob No. J002501

@A2

Client:

LOUBSER

NOTES

THIS DRAWING MUST BE READ IN CONJUNCTION WITHALL RELEVANT SPECIFICATION, REPORTS, CONTRACTS AND DRAWINGS.

Scale:

Sheet

Date: MAR 2016

Drn by: Chk by:

Drawing:

ANCILLARY FLOOR PLAN

Suite 14, 755 Albany Hwy East Victoria Park WA 6101Tel | +61 8 9355 5484

Web | www.approvalsbydesign.com.au

© COPYRIGHT

720

2440x2170SLIDERS

1372

x181

077

2x12

10 O

BS13

72x1

810

2400x2410 SD

2400x930OP'NG

720

2400

x930

OP'N

G

870

2400 HIGH BI-FOLD

820

TF

720

820

LINEN W.M.PROV

4,400

9,690

14,09

0

3,280 4,430 4,090

11,800

4,400

9,230

13,63

0

1,240

780

3,370 2,910 5,520

1,460

1,060

E-075

E-085

E-055

E-065

PTY

WIR

KITCHEN

ENTRY

RAKINGCEILING

RAKINGCEILING

LIVING / DINING

BED2

GAMESMASTER BED

ALFRESCOTIMBER DECK @-80mm

VERANDAH 2TIMBER DECK @-80

VERANDAH 1TIMBER DECK @-80

ANCILLARY FLOOR AREA 119.93m²STORE AREA 8.75m²VERANDAH 1 AREA 25.99m²VERANDAH 2 & DECK AREA 50.30m²ALFRESCO AREA 15.51m²CARPORT AREA 37.21m²

CARPORT

TIMBER DECK@ -80

TIMBER DECK@ -80

TIMBER DECK@ -80

RAKINGCEILING

RAKINGCEILING

RAKINGCEILING

RAKINGCEILING

CEILING@2575 AFL

CEILING@2575 AFL

CEILING@2575 AFL

CEILING@2575 AFL

CEILING@2800 AFLCEILING

@2800 AFL

CEILING@2800 AFL

CEILING@2800 AFL

CEILING @2800 AFL

RAKINGCEILING

RAKINGCEILING

1286

x970

OBS

820 TF

820

720

620

2x820TF

1st

820

FLUMEDR/HOOD T

L'DRY

ENSBATH

RETAINING WALLREFER TO ENGINEER

SPECS

6x180=1080 STEPSREFER TO

ENGINEER SPECS

C.L. 2560 ABOVE CARPORT FLOORF.L. 1000mm

EXPOSED TIMBERPERIMETER BEAM

125x125TIMBER POST

1050 HIGH BALUSTRADEAS SELECTED TOENGINEER SPECS

RETAINING WALLREFER TO ENGINEER

SPECS

TIMBER STAIRSREFER TO

ENGINEER SPECS

TIMBER STEPSREFER TO

ENGINEER SPECS

STORE

3.22m x 3.50m3.00m x 3.19m

2.88m x 3.19m

8.61m x 4.25m

3.50m x 4.43m

5.25m x 4.68m5.25m x 4.74m

6.10m x 6.10m

SHELVING

SHELF & RAIL

SHELF & RAIL

bath

& sh

r

125x125TIMBER POST

125x125TIMBER POST

125x125TIMBER POST

EXPOSED TIMBERPERIMETER BEAM

EXPOSED TIMBERPERIMETER BEAM

1050 HIGH BALUSTRADEAS SELECTED TOENGINEER SPECS

1.50m x 5.34m

2400 2400 2400

2560

2400

2650

2,800

3,340

25062

4

F.L. 00c

C.L. 2800 + PLATE

GROUND LEVEL

SHEET METAL ROOF@20°49'

CEDAR BOARDCLADDING

GROUND LEVEL

2560

3274

TIMBER STAIRSREFER TO

ENGINEER SPECS

1050 HIGH BALUSTRADEAS SELECTED TOENGINEER SPECS

TIMBER FRAMED FLOOR CONSTRUCTIONTO BE IN ACCORDANCE WITH A.S. 1884

REFER TO ENGINEER DETAILS FORSUB FLOOR MEMBER SIZES & POSITION

125x125TIMBER POST

BI-FOLD DOOR BELOW 2400 AFL

2650 AFL

3274 AFL

EXPOSED TIMBERPERIMETER BEAM

2400

2560

1028

2400

1627

3480 3590

1028 2,800

1,000

2,560

F.L. 00c

C.L. 2800 + PLATE

SHEET METAL ROOF@20°49'

CEDAR BOARDCLADDING

OBSCUREDGLAZING

GROUND LEVEL

NATURAL GROUND LEVEL

GROUND LEVEL

TIMBERDECK@ -80

F.L. 00mm

CARPORT F.L.

CARPORT C.L.

min 150mm SUBFLOORVENTILATION AS PER

NCC 2014 VOLUME 2 PART 3.4.1.

SHEET METAL ROOF@20°49'

NATURAL GROUND LEVEL

1050 HIGH BALUSTRADEAS SELECTED TOENGINEER SPECS

125x125TIMBER POST

TIMBER STAIRSREFER TO

ENGINEER SPECS

EXPOSED TIMBERPERIMETER BEAM

6x180=1080 STEPSREFER TO

ENGINEER SPECS

RETAINING WALLREFER TO

ENGINEER SPECS TIMBER FRAMED FLOOR CONSTRUCTIONTO BE IN ACCORDANCE WITH A.S. 1884

REFER TO ENGINEER DETAILS FORSUB FLOOR MEMBER SIZES & POSITION

2400

2560

0

2143 2400

2560

2400

1114

3480 3590

2,800

1,000

2,560

F.L. 00c

C.L. 2800 + PLATE

NATURAL GROUND LEVEL

SHEET METAL ROOF@20°49'

CEDAR BOARDCLADDING

OBSCUREDGLAZING

GROUND LEVEL

NATURAL GROUND LEVEL

TIMBERDECK@ -80

F.L. 00mm

CARPORT F.L.

min 150mm SUBFLOORVENTILATION AS PER

NCC 2014 VOLUME 2 PART 3.4.1.

CARPORT C.L.

SHEET METAL ROOF@20°49'

GROUND LEVEL

1050 HIGH BALUSTRADEAS SELECTED TO

ENGINEER SPECS

125x125TIMBER POST

EXPOSED TIMBERPERIMETER BEAM

6x180=1080 STEPSREFER TOENGINEER SPECS

RETAINING WALLREFER TOENGINEER SPECS

TIMBER FRAMED FLOOR CONSTRUCTIONTO BE IN ACCORDANCE WITH A.S. 1884

REFER TO ENGINEER DETAILS FORSUB FLOOR MEMBER SIZES & POSITION

2400

2560

2143

02,8

00

3,332

F.L. 00c

C.L. 2800 + PLATE

GROUND LEVEL

SHEET METAL ROOF@20°49'

CEDAR BOARDCLADDING

CEDAR BOARDCLADDING

BARGE & CAPPINGCEDAR BOARD INFILL

min 150mm SUBFLOORVENTILATION AS PER

NCC 2014 VOLUME 2 PART 3.4.1.

TIMBERDECK@ -80

125x125TIMBER POST

EXPOSED TIMBERPERIMETER BEAM

TIMBER FRAMED FLOOR CONSTRUCTIONTO BE IN ACCORDANCE WITH A.S. 1884

REFER TO ENGINEER DETAILS FORSUB FLOOR MEMBER SIZES & POSITION

1:100

BC 2 of 4

1. ANCILLARY FLOORPLAN1:100

E-05 ANCILLARY ELEVATION 51:100

E-06 ANCILLARY ELEVATION 61:100

E-08ANCILLARY ELEVATION 81:100

E-07ANCILLARY ELEVATION 71:100

OCM084.2.07.17

Address - LOT 725 SELKIRK ROADSuburb - SERPENTINESHIRE OF SERPENTINE / JARRAHDALE

PROPOSED DWELLING&

ANCILLARYACCOMMODATION

Project Name Project Address

Revision: DJob No. J002501

@A2

Client:

LOUBSER

NOTES

THIS DRAWING MUST BE READ IN CONJUNCTION WITHALL RELEVANT SPECIFICATION, REPORTS, CONTRACTS AND DRAWINGS.

Scale:

Sheet

Date: MAR 2016

Drn by: Chk by:

Drawing:

ELEVATIONS

Suite 14, 755 Albany Hwy East Victoria Park WA 6101Tel | +61 8 9355 5484

Web | www.approvalsbydesign.com.au

© COPYRIGHT

2400 2400 2350

857 856

2350 2450

0 0

2400 2450

2,800

F.L. 00mm

C.L. 2800mm

GROUND LEVEL

SHEET METAL ROOF@8° PITCH

CEDAR BOARDCLADDING

CEDAR BOARDCLADDING

SHEET METAL ROOF@8° PITCH

SHEET METAL ROOF@8° PITCH

SHEET METAL ROOF@3° PITCH TO VERANDAH

2350 2450

2143

0

2400

857

2400

900

2400

0

2400

857

2350 2450

2,800

F.L. 00mm

C.L. 2800mm

GROUND LEVEL

SHEET METAL ROOF@8° PITCH

CEDAR BOARDCLADDING

SHEET METAL ROOF@8° PITCH

CEDAR BOARDCLADDING

OBSCUREDGLAZING

STRUCTURAL COLUMNTO ENGINEER SPECS

STRUCTURAL COLUMNTO ENGINEER SPECS

SHEET METAL ROOF@3° PITCH TO VERANDAH

3124

3724

1050 HIGH BALUSTRADEAS SELECTED TOENGINEER SPECS

857

2350 2350 2450

2400

1800 1714

2450

2143

0

2900

3500

2900

3500

2,800

F.L. 00mm

C.L. 2800mm

GROUND LEVEL

SHEET METAL ROOF@8° PITCH

CEDAR BOARDCLADDING

CEDAR BOARDCLADDING

OBSCUREDGLAZING

NATURAL GROUND LEVEL

SHEET METAL ROOF@8° PITCH

CEDAR BOARDCLADDING

NATURAL GROUND LEVEL

GROUND LEVEL

min 150mm SUBFLOORVENTILATION AS PER

NCC 2014 VOLUME 2 PART 3.4.1.

SHEET METAL ROOF@20° PITCHSHEET METAL ROOF

@3° PITCH TO VERANDAH

1050 HIGH BALUSTRADEAS SELECTED TO

ENGINEER SPECS

6x180=1080 STEPSREFER TO

ENGINEER SPECS

RETAINING WALLREFER TO

ENGINEER SPECS

TIMBER FRAMED FLOOR CONSTRUCTIONTO BE IN ACCORDANCE WITH A.S. 1884

REFER TO ENGINEER DETAILS FORSUB FLOOR MEMBER SIZES & POSITION

2350 2450

2400

2560

2400

857

2400

686

2900 3500

857

2900 3500

2,800

F.L. 00mm

C.L. 2800mm

SHEET METAL ROOF@8° PITCH

CEDAR BOARDCLADDING

CEDAR BOARDCLADDING

OBSCUREDGLAZING

NATURAL GROUND LEVEL

NATURAL GROUND LEVEL

GROUND LEVEL

min 150mm SUBFLOORVENTILATION AS PER

NCC 2014 VOLUME 2 PART 3.4.1.

SHEET METAL ROOF@20° PITCH SHEET METAL ROOF

@3° PITCH TO VERANDAH

6x180=1080 STEPSREFER TO

ENGINEER SPECS

RETAINING WALLREFER TO

ENGINEER SPECS TIMBER FRAMED FLOOR CONSTRUCTIONTO BE IN ACCORDANCE WITH A.S. 1884

REFER TO ENGINEER DETAILS FORSUB FLOOR MEMBER SIZES & POSITION

1:100

BC 4 of 4

E-01 ELEVATION 11:100

E-03 ELEVATION 31:100

E-02 ELEVATION 21:100

E-04 ELEVATION 41:100

OCM084.2.07.17