Fire protection in building
Technological innovations which provide solutions for fire protection of lifeand property in:According to UNE-EN-12.845: Colleges, schools and offices with low fireload and low flammability, which are not unitary surfaces over 126 m2 witha fire resistance of less than 30 minutes. Penitentiary Institutions.According to NFPA-13: Educational centers, hospitals, nursing homes,hotels, libraries, museums, offices, homes, restaurants, theaters and audito-riums (excluding scenarios), churches, clubs and penitentiary institutions.
w w w . a n b e r g l o b e . c o m
Light hazard
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:56 Página 1
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:56 Página 2
INDEX
FIXED SYSTEMS: AUTOMATIC SPRINKLERS
Automatic sprinkler.....................................................................................1Valve....................................................................................................................4
FIRE SERVICE EQUIPMENTS
Hydrant..............................................................................................................5FHCs and IPF..................................................................................................6
SYSTEM COMPONENTS
Pump control valve....................................................................................7Valves..................................................................................................................8Electric switches and monitoring devices.....................................9
PIPE, COUPLINGS AND SUPPORT
CPVC pipe....................................................................................................10Steel pipe.......................................................................................................11Stainless Steel..............................................................................................12
Page
w w w . a n b e r g l o b e . c o m
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:56 Página 3
DH-80 SPRINKLER
Fix
ed
Sys
tem
s: A
uto
mat
ic S
pri
nkl
ers
1
NEW COVERAGE HORIZONTAL SIDEWALL 8.4 MWIDTH AND 4.2 M LENGHT
Install 1 sprinkler instead of 2
LONG & NARROW APPLICATIONS:
- Hallways- Decks- Balconies- Corridors- Roofs- Room up to 28’ (8.5 m) long
STYLES AVAILABLE:
- Horizontal sidewall- Horizontal sidewall recessed- Horizontal sidewall concealed
INSTALLATION CRITERIA:
- Distance between sprinkler maximum 8.4 mminimum 3.6 m
- Distance opposite wall 4,2 m- Deflector to ceiling dimensions are 100 mm
minimum and 305 mm maximum.- Smooth and flat roofs- K= 116
FINISHINGS:
- White, chrome, other colorsavailable
Máximum coverage: 8.5m x 4.3mResponse: QuickK=116Design norm: NFPA 13Technical Bulletin: 003
w w w . a n b e r g l o b e . c o m
Consult technical bulletin nº 003
4.2
m4.
2 m
8.4 m
AUTOMATIC SPRINKLERS
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 4
DECORATIVES
INSTITUTIONAL
Fixe
d Syste
ms: A
uto
matics Sp
rinkle
rs
2w w w . a n b e r g l o b e . c o m
1 Maximum coverage area in the cases considered in design norm.
AUTOMATIC SPRINKLERS
XL.EC AND XL PENDENT XL.EC AND XL PENDENT
GL CONCEALED
AGC, AGC-QR CONCEALEDINCH CONCEALED
MILLENIUM
BASIC SIDEWALL RECESSED BASIC PENDENT RECESSED
SWC56 SIDEWALL CONCEALEDResponse: Standard and quickK (metric): 39, 59, 80Design norm: UNE-EN-12.845 NFPA 13 Coverplate: Adjustable threepositionTechnical bulletin: GL 2854 /GL2804
Response: Standard and quickK (metric): 80 Design norm: UNE-EN-12.845 NFPA 13 Coverplate: Adjustable up to 1"Technical bulletin: GL 5653 /GL 5606
Response: Standard and quickK (metric): 39, 59, 80, 111, 116Design norm: UNE-EN 12.845NFPA 13 Technical bulletin: GL 5651 /GL 2801
Response: Standard and quickK (metric): 39, 59, 80, 111, 116Design norm: UNE-EN 12.845NFPA 13Technical bulletin: GL 5651 / GL 2801
Response: QuickK (metric): 80Design norm: UNE-EN-12.845NFPA 13Technical bulletin: GL 5650
Response: Standard and quickK (metric): 40, 60, 80Design norm: UNE-EN12.845NFPA 13Coverplate: ajustable por roscaTechnical bulletin: 121/154
Response: Standard and quickK (metric): 80Design norm: UNE-EN-12.845NFPA 13Coverplate: Adjustable by threadTechnical bulletin: 168
Coverage1: 4.9 m x 4.9 mKK (metric): 80Response: QuickDesign norm: NFPA 13Hoja técnica: 113
Coverage1: 4.9 m x 4.9 mKK (metric): 80Response: QuickDesign norm: NFPA 13Hoja técnica: 113
ZX-1
Response: QuickK (metric): 80Design norm: UNE-EN 12.845NFPA 13Technical bulletin: 134
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 5
EXTENDED COVERAGE
JL 112 UPRIGHT
HORIZONTAL SIDEWALL
G4 XLO CONCEALED
DH 56 DH 80
Fix
ed
Sys
tem
s: A
uto
mat
ics
Spri
nkl
ers
3
Max. Coverage1: 37.2 m2
Respons: QuickK (metric): 160Design norm: NFPA 13Technical bulletin: 173
JL 112 PENDENT
Max. Coverage1: 37.2 m2
Respons: QuickK (metric): 160Design norm: NFPA 13Technical bulletin: 172
Max. Coverage1: 4.87 m x 6.7 mRespons: Standard and QuickK (metric): 80 and 116Design norm: NFPA 13Technical bulletin: GL5628,GL8128
Max. Coverage1: 6.09 m x 6.09 mRespons: Standard and QuickK (metric): 160Design norm: NFPA 13Technical bulletin: 144
Max. Coverage1: 8,5 m x 3 mRespons: RápidaK (metric): 80Design norm: NFPA 13Technical bulletin: 015
Max. Coverage1: 8.5 m x 4.3 mRespons: QuickK (metric): 116Design norm: NFPA 13Technical bulletin: 003
HORIZONTAL SIDEWALL CONCEALED
Max. Coverage1: 4.87 m x 6.09 mRespons: QuickK (metric): 80, 116Design norm: NFPA 13Technical bulletin: GL 5613
PENDENT CONCEALED
Max. Coverage1: 6.09 m x 6.09 mRespons: QuickK (metric): 116Design norm: NFPA 13Technical bulletin: GL 8104
PENDENT
Max. Coverage1: 6.09 m x 6.09 mRespons: QuickK (metric): 80, 116Design norm: NFPA 13Technical bulletin: 148, GL 8109
DH 56 CONCEALED DH 80 CONCEALED
Max. Coverage1: 8.5 m x 3 mRespons: QuickK (metric): 80Design norm: NFPA 13Technical bulletin: 015
Max. Coverage1: 8.5 m x 4.3 mRespons: QuickK (metric): 116Design norm: NFPA 13Technical bulletin: 003
w w w . a n b e r g l o b e . c o m
Fid
SA
iS
ikl
1 Maximum coverage area in the cases considered in design norm.
F1FR EPEC PENDENT
Max. Coverage1: 17.64 m2
Respons: QuickDesign norm: UNE-EN 12.845with TB222 LPCTechnical bulletin: 012
AUTOMATIC SPRINKLERS
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 6
VALVE
WET
PREACTION SYSTEM
RISER CHECK: CONTROL OF PLANT AND AREA
MODEL H1, H2, H3
AGC-X MODEL
Fixe
d Syste
ms: A
uto
matic Sp
rinkle
rs
4
Operating principle: water / waterUse: Schools, hospitals, homes, offices, restaurants, theaters andpremises that have similar conditions and use.Norm: UNE-EN 12845, NFPA 13 AND FMDiameters: 2 ½”, 3”, 4”, 6” and 8”
Operating principle: water / detection and/or compressed airUse: Buildings where the effect of water can cause as much dam-age as the fire such as museums, libraries and penitentiary institutionsNorm: UNE-EN 12845, NFPA 13 AND FMDiameters: 2”, 2 ½”, 3”, 4” and 6”
Description:When the detection system send a sign, valve open and water floodthe pipes emiting an alarm. Water keep into pipes until sprinkleropen by the efect of fire.
w w w . a n b e r g l o b e . c o m
Description:Pipes contain water. When the sprinkler is opened by the actionof the fire, water is discharge inmediatly
Operating principle: water / waterUse: Buildings in height with more than one plant or area for eachvalveNorm: UNE-EN 12845, NFPA 13 and FMDiameters: 1” – 8”
Description:The pipes contain water. They allow monitoring, draining, purgeand control the installation of sprinklers in more than one plant foreach checkpoint
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 7
CALIFORNIA
WET PILLAR FIRE HYDRANT
DRY PILLAR FIRE HYDRANT
UNDERGROUND FIRE HYDRANT
HYDRANT
SUPERTIFON, TIFON, TIFON PLUS
Serv
ice
Fir
e E
xti
nti
on
5
Use: Buildings located in places without frost problems, traffic or spaceon sidewalks.Flow rate sparehead: 500 l/minMax. Distance: 80 m real routeK factor: outlet of 70 mm K 1745 and outlet of 100 mm K 3780 (K onlyhydrant)Design characteristic: The hydrant is equipped with globes valves, whichhave separate opening and closing for each outlet built into the hydrantbody.
Use: Buildings located in places with problem of frost andheavy traffic.Flow rate sparehead: 500 l/minMax. Distance: 80 m real routeK factor: outlet 70 mm K1900 and outlet 100 mm K 3300(K only hydrant)Design characteristic: Frost-free System: This model isequipped with a device which AUTOMATICALLY DRAINSany water in the standpipe when the main valve isclosed, preventing frost damage. Break-resistantSystem: The hydrant is also equipped with a device simi-lar to a fuse which, in the case of a heavy blow, willbreak where the body is connected to the barrel, releas-ing the main valve which will automatically emainclosed because of the water pressure, thereby ensuringfull tightness without the need for auxiliart components.
Use: Buildings located in places with space problems on sidewalks.Flow rate sparehead: 500 l/minMax. Distance: 80 m real routeK factor: outlet 70 mm K1830 and outlet 100 mm K 3080Design characteristic: The locking mechanism is built on non-ferrous materials,thus impeding that with the passage of time, is leaking due to corrosion. Theyincorporate an optional automatic drainage system, which prevents damageby frost.
w w w . a n b e r g l o b e . c o m
Fid
SA
iS
ikl
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 8
RISER CHECK VALVE
DRY RISER (IPF 39, 40 AND 41)
25 FHCs with 45 mm connector
FHCs AND IPF
25 FHCs
Fire Se
rvice E
qu
ipm
en
ts
6
Hose: semi-rigid 25 mmUse: Have water spearhead, it does not need to be spreaded inits entirety for useMinimum flow rate: 100 l/minMaximum distance: 25 real routeK factor: 42
Hose: semi-rigid 25 mmUse: Allows the adjustment of additional hose 45Minimun flow rate: 200 l/minMaximum distance: 25 real route
Use: Backstop, discharge, control and monitoring of waternetwork of FHCsDiameter: 1 1/2” to 8”Norm: NFPA 13 D/ 13R
IPF 39: Outlet in floor with 2 connections 1 1 / 2 "(45 mm)IPF 40: Outlet in floor with 2 connections 1 ½” (45mm). Valvesevering 3 "(80 mm)IPF 41: Connection at facade with 2 connections 2 ½” (70 mm)Use: water free-instalation, incorporated into the building tosupport the fire department services. It is used by connectingthe fire department vehicle to the facade inlet in order to sup-ply water to the floor outlets.
w w w . a n b e r g l o b e . c o m
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 9
MODEL FP 720 AND FP420
MODEL FP450
PRESSURE REDUCING VALVE
PUMP CONTROL VALVE
LEVEL CONTROL VALVE
Syst
em
Co
mp
on
en
ts
7
MODEL FP430, FP730 AND FP436
w w w . a n b e r g l o b e . c o m
Use: Contributing to establish pressure zones, maintaining the hydraulic balance inthe water distribution systems against fire. They are responsible for reducing thepressure highest input to a predetermined constant pressure and lower output.
-Line-pressure driven – Independent operation-Hydraulic actuation
Close drip tight under static pressureHigh flow capacity
-Operation through pilot – easy calibration-Free obstacles in the single cavity – Free flow-Pre-assembled trim-In-line serviceable – Easy maintenance
-Hydraulically powered valve designQuick reactionCloses drip tight time after timeEliminates jamming problems
-Advanced pilot systemAdjustable closung speedEliminates pressure surges
-System pilot dual parallel-One-piece molded single moving part – no maintenance required-Free obstacles in the single cavity – Free flow -In-line serviceable – Easy maintenance
-Line-pressure driven – Independent operation-Balanced rolling-diaphragm
High flow capacityVery low opening & closing pressure requirement
-Dynamically restrained actuationNon-slam closing
-Free obstacles in the single cavity – Free flow -External installation
Easy access to valve & flotaLess wear and tear
-In-line serviceable – Easy maintenance
Use: The pressure control pressure valves of the pump is activated by the hydraulicpressure in the line and are designed to protect the pumping systems and waterdistribution.
Use: Water level control of tank in protection against FIRE instalation.Fi
Si
Ei
CONTROL PRESSURE VALVE
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 10
CHECK VALVE GROOVED
RESILIENT SEATED OS&Y GATE VALVE / RESILIENT SEATED NRS GATE VALVE
VERTICAL AND HORIZONTAL INDICATOR POST
BUTTERFLY VALVE
CHECK VALVE
VALVES System
Co
mp
on
en
ts
8
OS&Y NRS
w w w . a n b e r g l o b e . c o m
Use: Open and close water flowApprovals: FM and ULPN: 16 barConnection: Flanged
Use: Show open/close shut-off valve position Approvals: FM, UL
Use: Open and close water flow with gear oper-ator, indicator switch and position switch.Approvals: FM, ULPN: from 12 to 21 barConnection: Threaded, grooved and flanged
Use: They prevent reverse flow preventingemptying facilitiesApprovals: FM, UL, ULCPN: 12 barConnection: Threaded and flanged
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 11
COMPRESSOR
TAMPER SUPERVISORY SWITCHES
WATERFLOW SWITCHES
Syst
em
Co
mp
on
en
ts
9
PRESSURE SWITCHES
WATER TANK SWITCHES
ELECTRIC SWITCHES AND MONITORING DEVICESSC
w w w . a n b e r g l o b e . c o m
Use: Electric Monitoring of waterflowand/or airflow in the instalationApprovals: UL, FM, LPCB, CE
Use: Show valve positionApprovals: UL, FM, CE
Use: Pressurization of the sprinkler network in drypipe system and preaction systemTypes: Coaxial, belt, diesel
Use: Show level of water in the tankApprovals: UL
Use: Electric Monitoring of waterflowand/or airflow in the instalationApprovals: UL, FM, LPC, CE
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 12
FITTINGS & COUPLINGS
PIPE HANGERS AND SUPPORT
CPVC PIPE
10
CPVC PIPE Pip
e, C
ou
plin
gs and
Sup
po
rt
w w w . a n b e r g l o b e . c o m
-Resistant to aggressive environments and condensation-Pipes from 3 / 4 "to 3"-Post chlorinated poly vinyl chloride-Its lightness eases the assembly and eliminates the need forqualified staff
-Minimizing redundant in works-Better coefficient of friction (lower pressure drop), C = 140
Use: Union of CPVC pipe. Tees. Sprinkler teePN: 12 barWorking temperature: +2ºC + 66 ºCDescription: provide flexibility for the installation. No need for qualifiedpersonnel. Eliminate welding work
Use: Clamp and hanger / fastener accesories /Channel / Fixing accessories / ComplementsDescription: Designed to support pipe in caseof fire.
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 13
STEEL PIPE PREFABRICATION
GROOVED FITTINGS & COUPLINGS
11
STEEL PIPEP
ipe
, C
ou
pli
ngs
an
d S
up
po
rt
GROOVED FITTINGS & COUPLINGS
PIPE HANGERS AND SUPPORT
-Any pipe: any standard, from 1” up to 12”-Any finish available-Process standardization and improving quality product.-Easy assembly and it is not needed professional labour force.-Minimizing redundant in works-Planning of a priori assembly.-Sizing and calculation based on real installation
Use: joint of steel pipe, Tee, sprinkler tee.PN: 21 barWorking temperature: -60º + 110º CDescription: Give flexibility to instalation. Without profesional labour force. Eliminate welding
Description: It consists of a tube corrugated helical flexible ofstainless steel, one outlet, a reducer, a bar and two support fixingreducer to the support guides of false ceiling ensuring a perfectposition for automatic sprinklers.Approvals: UL / FM
Use: Clamp and hanger / fastener accesories / Channel / Fixing acces-sories / ComplementsApprovals: FM, ULDescription: Designed to support pipe in case of fire.
w w w . a n b e r g l o b e . c o m
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 14
w w w . a n b e r g l o b e . c o m
FITTINGS & COUPLINGS
PIPE HANGERS AND SUPPORT
STAINLESS STEEL PIPE
12
STAINLESS STEEL PIPE Pip
e, C
ou
plin
gs and
Sup
po
rt
- Resistant to aggressive environments and condensation- Pipe 10 mm to 108 mm- Stainless steel AISI 304 or AISI 316- It facilitates the assembly to be slight and there was no need for
the qualified personnel- Minimizing redundant in works- Better coefficient of friction (lower pressure drop), C = 140
Use: Union of stainless steel pipe. Tees. SprinklerteePN: 20 barWorking temperature: -30 ºC +110 ºCDescription: provide flexibility for the installa-tion. No need for qualified personnel. Eliminatewelding work
Use: Clamp and hanger / fastener accesories /Channel / Fixing accessories / ComplementsApprovals: FM, ULDescription: Designed to support pipe in case of fire.
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 15
w w w . a n b e r g l o b e . c o m
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 16
w w w . a n b e r g l o b e . c o m
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 17
w w w . a n b e r g l o b e . c o m
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 18
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 19
Avda. de las Flores, 13 -15 - P.E. El Molino28970 Humanes de Madrid - Madrid (España)
Tel.: (+34) 91 606 37 11Fax: (+34) 91 690 95 61e-mail: [email protected]
w w w . a n b e r g l o b e . c o m
RIESGO LIGERO:RIESGO LIGERO 24/6/08 14:57 Página 20