am_ss03_e2_p1 zxa10-msan cabinet & power module introduction(malaysia) v1.1 19p

19
A10&DSL D&T Group A10&DSL D&T Group AM_SS03_E2_P1 AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction ZXA10-MSAN Cabinet & Power Module Introduction V1.1 V1.1

Upload: honestcheater

Post on 29-Dec-2015

29 views

Category:

Documents


2 download

DESCRIPTION

asd

TRANSCRIPT

Page 1: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

A10&DSL D&T GroupA10&DSL D&T Group

AM_SS03_E2_P1AM_SS03_E2_P1

ZXA10-MSAN Cabinet & Power Module Introduction

ZXA10-MSAN Cabinet & Power Module Introduction

V1.1V1.1

Page 2: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

2

Course OutlineCourse Outline

OUT60 Rack Introduction

ZXDU45 Power Module Introduction

Page 3: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

3

Rectifier(Height 3U)

AC&DC

Grounding box

U300 control shelf(Height 9U)

S200 shelf(Height 2U)

100AH

L0

U300 subscriber shelf(Height 9U)

L1

U300 subscriber shelf(Height 9U)

L2

Dis

tribu

tion

area

Wire routing frame(Height 1U)1# Fan tray(Height 1U) accumulator

wind outlet layer(Height 2U)

wind outlet layer(Height 1U)

wind outlet layer(Height 2U)

wind outlet layer(Height 1U)

accumulator100AH

accumulator100AH 100AH

accumulator

Wire routing frame(Height 1U) Wire routing frame(Height 1U)2# Fan tray(Height 1U)

wind outlet layer(Height 2U)

wind outlet layer(Height 2U)

Power distribution box

Overall compositionOverall composition

Page 4: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

4

OUT60 SpecificationOUT60 SpecificationItems Description

Cabinet 620 kg

Dimensions 1600 mm × 1500 mm × 780 mm (height ×width × depth)

Operating Voltage 220 ± 30% V AC 50 Hz240 ± 30% V AC 60 Hz

Ambient Temperature –35˚C to 40˚C

Power Consumption 2000 w (without heater module)4300 w (with heater module)

Relative Humidity 10% to 100%

Grounding Resistance ≤10 ohm

Storage Battery 12 V/100 -Ah

Environment Conditions The cabinet is used outside where electromagnetism is weak

Storage Battery Four 12 V/100 Ah storage batteries

Rainproof and Dustproof MeasuresMeet IEC IP5.5 and adopt special process for major components to increase corrosion-proof capability

Page 5: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

5

OUT60 module configurationOUT60 module configurationThe following are OUT60 module configuration:

Power supply module

Control and processing module

Test module

Subscriber module

Transmission module

Monitoring module

Page 6: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

6

Power Supply ModulePower Supply ModuleThis power supply module provides the following functions:

It filters power and feeds 220 V AC to power rectifier and pass it to power distribution box and provides grounding to prevent equipment from lightning.

Four batteries provide -48 V DC connection. Batteries are used as a backup power.

POWER K card provides secondary power +5 V,-48 V DC and ringing current -75 V AC.

Page 7: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

7

Control And Process ModuleControl And Process ModuleThe Control And Process Module supply module provides the

following functions:

It implements service control

It supports multiple accesses such as narrowband voices, data at various rates, DSL, and LAN

Page 8: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

8

Test ModuleTest ModuleThe Test Module supply module provides the following functions:

Measures insulation resistance, AC/DC voltage, inter-line capacitance

Detects signal tone, tests equipment receiving pulse number, DTMF number receiving functions and tests dialing tone.

Measures ringing output voltage and frequency.

Page 9: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

9

Subscriber ModuleSubscriber ModuleBuilt-in MDF wiring module

Internal line modules support 1152 loops.

External line modules support 1400 loops.

Page 10: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

10

Transmission ModuleTransmission ModuleBuilt-in MSTP Products S200

ZXA10-S200 is positioned at the MAN access layer, and supports L2 Ethernet convergence between multiple NEsand small-capacity TDM service.

ZXA10-S200 is capable of access, transparent transmission and convergence of the TDM service, Ethernet service and ATM service

Page 11: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

11

Monitoring ModuleMonitoring Module

Monitoring equipment temperature

Monitoring humidity

Smoke monitoring

Alarm indications

Flood

Secondary Power

Page 12: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

12

IM A E H D B

RSTRST

ALM

HOOK

RUN

A LCIS T 1A IC S

RSTRST

ALM

HOOK

RUN

A LC

RSTRST

ALM

HOOK

RUN

A LC

RSTRST

ALM

HOOK

RUN

A LC

RST

U8

U5

U7

U6

U4

U3

ALM

U2

U1

RUN

D LC A

RST

U8

U5

U7

U6

U4

U3

ALM

U2

U1

RUN

D LC A IC S A D LA D L

RSTRST

ALM

HOOK

RUN

A LC

3

4

5

P E B

1

2

2

3

IE B A

1

3

IE B B

1

2

S E B IS E BE PE B

3

4

5

P E B

1

2

S E B S E B SE B S E B S E B S E B SE BSE BSE B

OUT60 Shelf LayoutOUT60 Shelf Layout

Page 13: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

13

Subscriber cableSubscriber cable

68

34

67

33

3736

32

C

35

1

End A End B

Di rect i on C

Page 14: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

14

Cascading cableCascading cable

C

Pos. 50 Pos. 1

Pos. 1 Pos. 50

D

End AEnd B1

End B2

Di rect i on C Di rect i on D

Page 15: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

15

Monitoring CableMonitoring Cable

B5B6B7B8B9B10B11B12

B15B16

B25

B20B21

B23B24

B22

CB14

B17

B3

B13

B19

B18

B4

B1

B2

End A

End B

Di r ect i on C

Page 16: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

16

ZXDU45, ZXDU75---Built-in Power System

ZXDU45, ZXDU75---Built-in Power System

Page 17: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

17

ZXDU45---Built-in Power System

ZXDU45---Built-in Power System

ID Indicator Status Meaning

PWR On The AC input is normal.

RUN Flashing The program is running normally.

COMM On The system is communicating with the background computer.

FAU On The equipment fails.

Page 18: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

18

ZXDU45---Built-in Power System

ZXDU45---Built-in Power System

AC input (single-phase,

3-wire)

Anti-lightning

power distribution

unit

Switched rectifier (3 at

the most)

Load I

Load II

Battery

Monitoring unit

Near-end monitoring

RS232RS232

MODEM MODEM Remote monitoring

Telephoneline

Page 19: AM_SS03_E2_P1 ZXA10-MSAN Cabinet & Power Module Introduction(Malaysia) V1.1 19p

univ.zte.com.cnuniv.zte.com.cn