Clause Parametrs Requirements
1 Dimensions, nominal (mm.) Inside Dia Thickness Outside
Dia.
1.A HDPE 5BO, Type 1 90 ±2 2.5 ±0.5 110 ±2
1.B Sub-ducts for Type 1 28 ±1 2.5 ±0.5 33 ±1
1.C HDPE 3DO, Type 2 90 ±2 2.5 ±0.5 110 ±2
1.D Sub-ducts for Type 2 36 ±1 2.8 ±0.5 42 ±1
1.E HDPE EO, Type 3 (Empty) 90 ±2 2.5 ±0.5 110 ±2
1.F HDPE 3CO, Type 4 58 ±2 2.5 ±0.5 77 ±2
1.G Sub-ducts for Type 4 22.2 ±1 2.5 ±0.5 27.2 ±1
2 Main duct wall design
Inner and outer walls shall be corrugat-ed with average pitch demension of
25.4±1mm. The corrugationshall either be helical or annular (ring)
3 Sub-duct wall design Outer and inner walls shall be plain and smooth
4 Fusion of main duct and Sub-duct
All contact surfaces between main duct and built-in sub-ducts shall fuse togeth-er during extrusion process. This fusion shall prevent movement or twisting of
subducts inside the main HDPE DUCT in finished products.
5Color of main HDPE duct Orange
Color of Sub-dcut According to customer requirement
AMS HDPE CORRUGATED DUCT AND SUB-DUCTTECHNICAL SHDPEIFICATION
DUCT SIZES AND DIMENSIONS
AMS HDPE & SUB-DUCT Pipes AMS HDPE & SUB-DUCT PipesAMS HDPE & SUB-DUCT Pipes AMS HDPE & SUB-DUCT Pipes
Type Model DesignConfiguration Description Application
1 HDPE-5BO HDPE-CD, 110mm OD, with5-33mm OD Sub-ducts
FOC installations
2 HDPE-3DO HDPE-CD, 110mm OD, with3-42mm OD Sub-ducts FOC installations
3 HDPE-EO HDPE-CD, 110mm OD,Without Sub-ducts
Copper Cableinstallations
4 HDPE-3CO HDPE-CD, 77mm OD, with3-27.2mm OD Sub-ducts FOC installations
General:HDPE Duct with built-in 5 sub-ducts for use in underground duct system Fiber Optical and Copper Cables.
PE 80 Pressure pipes according to DIN 8074 / 8075NominalOutside
Diametermm
SDR 33, S 16PN 3.1
SDR 26, S 12.5PN 4
SDR 17.6, S 8.3PN 6
SDR 11, S 5PN 10
SDR 9, S 4PN 12.5
SDR 7.4, S 3.2PN 15.3
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
16 - - - - - - - - 1.8 0.084 2.2 0.099
20 - - - - - - 1.9 0.112 2.3 0.133 2.8 0.154
25 - - - - - - 2.3 0.171 2.8 0.200 3.5 0.240
32 - - - - 1.8 0.179 2.9 0.272 3.6 0.327 4.4 0.386
40 - - 1.8 0.227 2.3 0.285 3.7 0.430 4.5 0.509 5.5 0.600
50 1.8 0.287 2.0 0.314 2.9 0.440 4.6 0.666 5.6 0.788 6.9 0.936
63 2.0 0.399 2.5 0.494 3.6 0.688 5.8 1.05 7.1 1.26 8.6 1.47
75 2.3 0.551 2.9 0.675 4.3 0.966 6.8 1.47 8.4 1.76 10.3 2.09
90 2.8 0.791 3.5 0.978 5.1 1.39 8.2 2.12 10.1 2.54 12.3 3.0
110 3.4 1.17 4.2 1.43 6.3 2.08 10.0 3.14 12.3 3.78 15.1 4.49
125 3.9 1.51 4.8 1.84 7.1 2.66 11.4 4.08 14.0 4.87 17.1 5.77
140 4.3 1.88 5.5 2.32 8.0 3.34 12.7 5.08 15.7 6.11 19.2 7.25
160 4.9 2.42 6.2 3.04 9.1 4.35 14.6 6.67 17.9 7.96 21.9 9.44
180 5.5 3.07 6.9 3.79 10.2 5.48 16.4 8.42 20.1 10.1 24.6 11.9
200 6.2 3.84 7.7 4.69 11.4 6.79 18.2 10.4 22.4 12.4 27.4 14.8
225 6.9 4.77 8.6 5.89 12.8 8.55 20.5 13.1 25.2 15.8 30.8 18.6
250 7.7 5.92 9.6 7.30 14.2 10.6 22.7 16.2 27.9 19.4 34.2 23.0
280 8.6 7.40 10.7 9.10 15.9 13.2 25.4 20.3 31.3 24.3 38.3 28.9
315 9.7 9.37 12.1 11.6 17.9 16.7 28.6 25.6 35.2 30.8 43.1 36.5
PE 100 Pressure pipes according to DIN 8074 / 8075NominalOutside
Diametermm
SDR 41, S 20PN 4
SDR 26, S 12.5PN 6.3
SDR 17, S 8PN 10
SDR 13.6, S 6.3PN 12.5
SDR 11, S 5PN 16
SDR 9, S 4PN 20
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
WallThick-nessmm
WeightKg/
Meter
16 - - - - - - - - - - 1.8 0.084
20 - - - - - - 1.8 0.107 1.9 0.112 2.3 0.133
25 - - - - 1.8 0.137 1.9 0.144 2.3 0.171 2.8 0.200
32 - - - - 1.9 0.187 2.4 0.232 2.9 0.272 3.6 0.327
40 - - 1.8 0.227 2.4 0.295 3.0 0.356 3.7 0.430 4.5 0.509
50 - - 2.0 0.314 3.0 0.453 3.7 0.549 4.6 0.666 5.6 0.788
63 1.8 0.364 2.5 0.494 3.8 0.721 4.7 0.873 5.8 1.05 7.1 1.26
75 1.9 0.457 2.9 0.675 4.5 1.02 5.6 1.24 6.8 1.47 8.4 1.76
90 2.2 0.643 3.5 0.978 5.4 1.46 6.7 1.77 8.2 2.12 10.1 2.54
110 2.7 0.943 4.2 1.43 6.6 2.17 8.1 2.62 10.0 3.14 12.3 3.78
125 3.1 1.23 4.8 1.84 7.4 2.76 9.2 3.37 11.4 4.08 14.0 4.87
140 3.5 1.54 5.4 2.32 8.3 3.46 10.3 4.22 12.7 5.08 15.7 6.11
160 4.0 2.0 6.2 3.04 9.5 4.52 11.8 5.50 14.6 6.67 17.9 7.96
180 4.4 2.49 6.9 3.79 10.7 5.71 13.3 6.98 16.4 8.42 20.1 10.1
200 4.9 3.05 7.7 4.69 11.9 7.05 14.7 8.56 18.2 10.4 22.4 12.4
225 5.5 3.86 8.6 5.89 13.4 8.93 16.6 10.9 20.5 13.1 25.2 15.8
250 6.2 4.83 9.6 7.30 14.8 11.0 18.4 13.4 22.7 16.2 27.9 19.4
280 6.9 5.98 10.7 9.10 16.6 13.7 20.6 16.8 25.4 20.3 31.3 24.3
315 7.7 7.52 12.1 11.6 18.7 17.4 23.2 21.2 28.6 25.6 35.2 30.8
AMS HDPE Pipes AMS HDPE PipesAMS HDPE Pipes HIGH DENSITY POLYTHYLENE P.E 100
PE 100 Pressure pipes according to DIN 8074 / 8075PE 80 Pressure pipes according to DIN 8074 / 8075
Dimension for PE 100Dimension for PE 80
PE 100 Physical Characteristics at 20 c˚Properties Test Method Units Typical Value
Density ASTM D 1505 g/cm 3 0.96Tensile Strength @ Yield Point ASTM D 638 kg./cm2 230 @ Break Point ASTM D 638 kg./cm2 350Melt Index (190C/5 kg.) ASTM D 1238 g/10min 0.21Elongation @ Break Point ASTM D 638 % > 600Vicat Softening Point ASTM D 1525 C 122Flexural Modulus ASTM D 747 kg./cm2 8500Izod Impact Strength ASTM D 256 kg-cm/cm 20Carbon Black Content ISO 6964 % 2Brittleness Temperature ASTM D 746 C <-75Pipe Sress Rupture 12.4 Mpa ISO 1167 Hrs. >100
AMS Plastic manufactures high density polyethyleneaccording to Din 8074 & ISO 4427 standard in different
various pressure ratings according to
pipes (H.D.P.E) size range from 16mm to 315mmpressure ratings sHDPEific sizes are also produced incustomer requirements.
A.M.S FACTORY FOR
POLYETHELENE
manufactures H.D.P.E. pipes
in P.E.80 and P.E.100 for the
telecommunication industry.
Strict quality control
measures are adopted
keeping into consideration
design parameters. Latest
co-extrusion technology is
used to produce bi-colour co-
extruded pipes.