virgin river dcip report - university of british columbia · 2011. 1. 26. · virgin river dcip...
Post on 09-Aug-2021
2 Views
Preview:
TRANSCRIPT
Data AcquisitionInversion
InterpretationDiscussion
Virgin River DCIP Report
Justin Granek1
1University of British Columbia
Geophysical Inversion Facility
Applied Geophysics, 2010
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Outline
1 Data AcquisitionLocationSurvey Specications
2 InversionData ErrorsDCIP2DDCIP3D
3 InterpretationCorrelationsSnowbird Tectonic Zone
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
LocationSurvey Specs
Outline
1 Data AcquisitionLocationSurvey Specications
2 InversionData ErrorsDCIP2DDCIP3D
3 InterpretationCorrelationsSnowbird Tectonic Zone
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
LocationSurvey Specs
RegionalAthabasca Basin, Northern Saskatchewan
Northern Saskatchewan
South Central Athabasca Basin
NTS Reference 74 G/12
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
LocationSurvey Specs
LocalWide Lake Grid
10 Lines runningNW-SE
Approximately 4kmlong each
Approximately 40line-km total
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
LocationSurvey Specs
Outline
1 Data AcquisitionLocationSurvey Specications
2 InversionData ErrorsDCIP2DDCIP3D
3 InterpretationCorrelationsSnowbird Tectonic Zone
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
LocationSurvey Specs
Electrode CongurationPole-Pole
Collected in Summer 2007-2008 by Patterson Geophysics Ltd.
Pole Spacing a = 150m
12 Stainless Steel Electrodes (Including Innites)
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
LocationSurvey Specs
Electrode CongurationCurrent Advance Protocol
For Electrodes n=1:6
Advance in Increments of 75m
For Electrodes n=7:10
Advance in Increments of 150m
Data Collected at Current-Potential Electrode Spacings of...
75m, 150m, 225m, 300m, 375m, 450m, 525m, 600m, 675m, 750m,825m, 900m, 1050m, 1200m, 1350m, and 1500m.
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
LocationSurvey Specs
HardwareInstrument Specications
Walcer TX9000 9.0 kW IP Transmitter
Walcer MG-12 Motor Generator
Two IRIS Instruments ELREC Pro Time DomainIP-Resistivity Receivers
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
LocationSurvey Specs
DataFiles Provided to UBC-GIF
RES2DINV File (.dat)
Reduced data format for RES2DINV software
Excel Spreadsheet (.xls)
File containing most of the raw data:
Voltage (mV)
Current (A)
Self Potential (mV/V)
20 Chargeability Channels (mV/V)
Local Tx/Rx Electrode Coordinates
Reduced Excel Spreadsheet (.xls)
Reduced data format for plotting pseudo-sections from Excel
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
LocationSurvey Specs
DataQuality
Duplicates
Data are mostly duplicated
Typically very similar
IP Data
Very noisy
Not very useful
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Outline
1 Data AcquisitionLocationSurvey Specications
2 InversionData ErrorsDCIP2DDCIP3D
3 InterpretationCorrelationsSnowbird Tectonic Zone
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Errors
Noise oor + 5% of each Datum
2D: Noise oor calculated as 90% of smallest value along line
3D: Noise oor calculated as 90% of smallest value
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Outline
1 Data AcquisitionLocationSurvey Specications
2 InversionData ErrorsDCIP2DDCIP3D
3 InterpretationCorrelationsSnowbird Tectonic Zone
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Survey Lines
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Local Grid: Default ParametersData
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Local Grid: Default ParametersInversion Results
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Local Grid: Default ParametersInversion Results
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
UTM: Fine MeshData
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
UTM: Fine MeshInversion Results
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Outline
1 Data AcquisitionLocationSurvey Specications
2 InversionData ErrorsDCIP2DDCIP3D
3 InterpretationCorrelationsSnowbird Tectonic Zone
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
UTM: Default ParametersInversion Parameters
Data 3582
Mesh 175 712 cells
Core Cell Size 75m×75m×37.5m
Reference Model 1000Ωm
Mist 4059
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
UTM: Default ParametersVertical Slice through Line 1200N
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
UTM: Default ParametersSurface View
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
UTM: Default Parameters375m Depth Slice
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
UTM: Default Parameters750m Depth Slice
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
UTM: Default ParametersResistivity Cuto of 300Ωm
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
ProblemsTopics worth Revisiting
Duplicated Data
IP Chargeability
Noisy Surface
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Duplicated DataComparison at 600m Depth Slice
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
IP ChargeabilityDecay Curves
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
IP ChargeabilityInversion
Datum 554
Mesh 165 528 cells
Core Cell Size 75m×75m×37.5m
Mist 2539
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
IP Chargeability600m Depth Slice: Useful...?
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Surface WeightingSurface View
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Surface WeightingVertical Slice through Line 1200N
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Surface Weighting375m Depth Slice
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
Data ErrorsDCIP2DDCIP3D
Surface Weighting750m Depth Slice
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
CorrelationsSnowbird Tectonic Zone
Outline
1 Data AcquisitionLocationSurvey Specications
2 InversionData ErrorsDCIP2DDCIP3D
3 InterpretationCorrelationsSnowbird Tectonic Zone
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
CorrelationsSnowbird Tectonic Zone
ZTEMRecall From Elliott's Presentation...
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
CorrelationsSnowbird Tectonic Zone
Outline
1 Data AcquisitionLocationSurvey Specications
2 InversionData ErrorsDCIP2DDCIP3D
3 InterpretationCorrelationsSnowbird Tectonic Zone
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
CorrelationsSnowbird Tectonic Zone
Snowbird Tectonic ZoneGraphitic Fault Oset
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
CorrelationsSnowbird Tectonic Zone
Snowbird Tectonic ZoneGraphitic Fault Oset
Justin Granek DCIP Report
Data AcquisitionInversion
InterpretationDiscussion
DiscussionFeedback, Questions & Opinions
What Do You Think?
Justin Granek DCIP Report
top related