1 WWW.ALLFASTENERS.COM.AUCall 1800 255 349
Revi
sed
Doc.
05.
03.2
015
Through Bolt AnchorsTorque Controlled Expansion Anchor
TECHNICAL DATA SHEET:
The Through Bolt is a permanent torque controlled anchor, using an expansion clip over a tapered working
end to achieve high capacity loading. The Through Bolt diameter is equal to the required drill hole making drill
selection easy and straight forward.
On installation the anchor uses its design to expand the clip against the hole wall pulling the body upwards
whilst clamping the fixture.
The Through Bolt can be used in a wide variety of applications with is availability from M8 to M20 in stain-
less steel or electroplated zinc plating and hot dipped galvanised carbon steel.
Material Specification
Components Carbon Steel Hot Dip Galvanised Stainless Steel
Body property class 4.8
AISI 316 (A4)
Expanding Clip Hardened carbon steel 316 (A4) Stainless Steel
Hex Nut property class 6
Flat Washer Hardened carbon steel
Plating/FinishElectroplated zinc plating (yellow)
to coating thickness of 3 microns min.Hot Dip Galvanised
coating thickness to 40 microns min.-
Stainless Steel Expansion Clip for effective high loading.
Chamfered end ensures easy removal & installation of nut & washer when bolt
head is damaged.
Anti-rotation dimples.
Tapered working end ensures optimum
performance
Reduced section prevents threads from damageHarden Carbon Steel or Stainless
Hex Nut & Washer pre-assembled
M10
A4
Featuring a reduced section on the length of the thread prevents damage when anchor is tapped into its embedment.
Designed as a torque controlled expansion anchor provides a min-imal effort upon install with easy torque setting into concrete and masonry base material.
The expansion clip features an-ti-rotation dimples and are made from heavy duty stainless steel for maximum corrosion protection.
2
Through Bolt AnchorsALLFASTENERS
sales@allfasteners.com.au
TECHNICAL DATA SHEET:
Call 1800 255 349
Revi
sed
Doc.
05.
03.2
015
Through Bolt Anchor: Hex Nut & Washer
Zinc Plated (Yellow)
ZINC YELLOW HD GALVANISEDAnchor* x O.A.L (mm)
MAX. Fixture Thickness (mm)
Drill DepthClearance Hole
ø (mm)Hex Nut A/F
(mm)
- 1PTBG08080 M8 x 80 15
O.A.L minus Fixture thickness
10 13
50 500
- 1PTBG08100 M8 x 100 40 50 500
- 1PTBG08120 M8 x 120 60 50 5001PTBZ10065 1PTBG10065 M10 x 65 10
12 1725 250
1PTBZ10090 1PTBG10090 M10 x 90 20 25 2501PTBZ10120 1PTBG10120 M10 x 120 50 25 2501PTBZ12080 1PTBG12080 M12 x 80 10
15 19
25 2501PTBZ12100 1PTBG12100 M12 x 100 25 25 2501PTBZ12140 1PTBG12140 M12 x 140 60 25 1501PTBZ12180 - M12 x 180 100 25 1001PTBZ16105 1PTBG16105 M16 x 105 10
19 24
25 1001PTBZ16125 1PTBG16125 M16 x 125 20 25 1001PTBZ16140 1PTBG16140 M16 x 140 35 25 1001PTBZ16190 1PTBG16190 M16 x 190 70 25 50
- 1PTBG20125 M20 x 125 1024 30
10 50- 1PTBG20160 M20 x 160 30 10 40- 1PTBG20200 M20 x 200 60 10 30
*Drill diameter O.A.L = Overall Length
AISI 316 (A4) Stainless Steel
Anchor* x O.A.L (mm)
MAX. Fixture Thickness (mm))
MIN. Drill Depth (mm)
Clearance Hole ø (mm)
Hex Nut A/F (mm)
1PTBS08090 M8 x 90 40
O.A.L minus Fixture thickness
10 1350 500
1PTBS108115 M8 x 115 60 SPECIAL ORDER1PTBS10060 M10 x 60 5
12 17
25 2501PTBS10075 M10 x 75 12 25 2501PTBS10090 M10 x 90 30 25 250
1PTBS10120 M10 x 120 50 25 250
1PTBS12080 M12 x 80 1015 19
25 250
1PTBS12100 M12 x 100 25 25 2501PTBS12135 M12 x 135 40 25 1501PTBS16105 M16 x 105 10
19 2425 150
1PTBS16140 M16 x 140 35 15 901PTBS20125 M20 x 125 10
24 3010 60
1PTBS20160 M20 x 160 35 10 601PTBS20200 M20 x 200 80 10 30
*Drill diameter O.A.L = Overall Length
Hot Dipped Galvanised
316 (A4) Stainless Steel
CARBON STEEL THROUGH BOLT
STAINLESS STEEL THROUGH BOLT
This information published in this section is based on the anchor 'minimum' embedment to achieve a 'maximum' fixture thickness. An increased embed-ment and reduced fixture thickness is permitted. For further assitance please contact Allfasteners.
NEWSIZENEWSIZE
3 WWW.ALLFASTENERS.COM.AUCall 1800 255 349
Revi
sed
Doc.
05.
03.2
015
Admissible working loads capacities for carbon steel Through Bolt
32 MPa Concrete 40 MPa ConcreteThread
SizeEmbed.
Depth* (mm)Torque (Nm) Tension (kN) Shear (kN) Tension (kN) Shear (kN)
M840
154.1 4.4 4.6 4.4
55 4.5 5.3 5.3 5.3
M1050
305.0 6.7 5.7 6.7
60 6.2 7.6 7.5 7.6
M1250
504.6 5.3 5.2 5.3
80 9.6 10.7 11.1 10.7
M1660
1206.4 9.5 7.3 9.5
100 15.4 16.5 18.0 16.5
M2080
20011.8 14.0 13.5 14.0
120 18.0 23.8 21.0 23.8
*Embedment Depth (mm) it the requirment of the anchor lengths into the base material.NOTE Incorporated safety factor for tension and shear values
PERFORMANCE DATAAdmissible working loads are based on standard spacing and edge distances.
SETTING
BMT
Spacing
Edge Distance
Base Material Thickness (BMT) There is a recommended minimum thickness of the solid base material that the anchor can be set in. The minimum is based on 1.5 times of the calculated embedment to be used.
SpacingThe anchor diameter is equal to the drill diameter which elimnates the need for hole plotting or layout. As the anchor can be spaced using the fixture the maximum load in tension or shear can be achieved by spacing anchors 10 times the selected diameter. This spacing can be reduced but the load value should also be reduced, see table below.
Edge Distance for Tension Should be determined by 12 times the selected anchor diameter to obtain the maximum load in tension. The recommended minimum spacing is 5 times the selected anchor diameter.In tension – reducing the edge distance to the minimum, the load value will reduce by 20%.
Edge Distance in TENSION only
LOAD CAPACITY 12 x D 11 x D 10 x D 9 x D 8 x D 7 x D 6 x D 5 x D
Reduce by 100% 3% 6% 9% 11% 14% 17% 20%
Reduction Factor 1.00 0.97 0.94 0.91 0.89 0.86 0.83 0.80
Anchor SPACING
LOAD CAPACITY 10 x D 9 x D 8 x D 7 x D 6 x D 5 x D
Reduce by 100% 10% 20% 30% 40% 50%
Reduction Factor 1.00 0.90 0.80 0.70 0.60 0.50
Dri
ll D
epth
Fixture
Em
bed
men
t
Shear
Tens
ion
Drill ø = Anchor ø
Drill Depth = OAL - FixtureBMT = Embedment Depth x 1.5
BMT
4
Through Bolt AnchorsALLFASTENERS
sales@allfasteners.com.au
TECHNICAL DATA SHEET:
Call 1800 255 349
Revi
sed
Doc.
05.
03.2
015
Melbourne – Head Office 78 - 84 Logistics Street, Keilor Park VIC 3042
Tel 03 9330 0555 | Fax 03 9338 6434
Sydney65 Atkins Road, Ermington NSW 2115
Tel 02 8844 4550 | Fax 02 9807 7500
Adelaide116 Churchill Road North, Dry Creek SA 5094
Tel 08 8396 2781 | Fax 08 8263 3769
ALLFASTENERS holds a Management System Conformity Certificate with ISO 9001:2008 accreditation, for implementing quality management systems, standards and guidelines for the supply & express delivery of fasteners to the industrial, heavy industry, mining & construction industries. Certificate No. AU1439
INSTALLATION1. Drill or core a hole to the recommended diameter and depth using the fixture as a tem-
plate. Clean the hole thoroughly removing debris with a hand pump, compressed air, or vacuum.
2. Insert the Through Bolt through the fixture and tap it into the hole until the nut and wash-er are in contact against the fixture. Ensure the anchor is embeded to the required depth.
3. Tighten the nut with a torque wrench to the specified assembly torque amount from a finger tighten position.
Edge Distance for Shear Should be determined by 12 times the selected anchor diameter to obtain the maximum load in shear. The recommended minimum spacing is 5 times the selected anchor diameter.
In shear – reducing the edge distance to the minimum, the load value will reduce by 50%.
Edge Distance in SHEAR only
LOAD CAPACITY 12 x D 11 x D 10 x D 9 x D 8 x D 7 x D 6 x D 5 x D
Reduce by 100% 7% 14% 21% 29% 36% 43% 50%
Reduction Factor 1.00 0.93 0.86 0.79 0.71 0.64 0.57 0.50