seminario peruano-alemán smart city visiones y soluciones ... · mexico city unam is one of the...

Post on 15-Jul-2020

1 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Seminario Peruano-Alemán Smart City – Visiones y Soluciones

Lima Nov. 2015

Water Recycling

Public Acceptance

Water Quality – Fit For Purpose

Questions to think about:

1. What quality of water is needed for different uses?

2. How much recycled water can be used?

Water Reuse Possibilities

Landscaping

Irrigation Cooling Towers

Groundwater Recharge

Amenity

Fire/Washdown

Toilets

Recycled Water Quality

Before After

Before After

Membrane Equipment

VRM

BioMem

smartMBR – Designed for Hotels etc.

HUBER

BioMem®

Installed in Modules.

Module sizes from 75m2 – 300m2

HUBER VRM®

2 x Size Ranges: 2m dia & 3m dia

Single machines available up to 3,840m2 membrane area

Very low energy consumption

Some Examples of

Installed Projects

11

Case Study – University in Mexico Universidad Nacional Autónoma de México Mexico City

UNAM is one of the largest universities in the world, with a total population (staff & students) of approximately 350,000. 1,500 m3/day Membrane Bioreactor (MBR) ultrafiltration system, to treat the combined black & grey wastewater. The treated water is recycled for irrigation of the campus green spaces.

Case Study – Resort in Turkey.

The Xanadu Island Resort

➤ 5 star hotel with 320 rooms and suites

➤ Approximately 9 restaurants & bars on site

➤ 880 individual villas

Case Study – Hotel in Greece.

Romanos Costa Navarino (operated by Starwood)

➤ 5 star with 321 rooms

➤ Approximately 10 restaurants & bars on site

➤ Open air cinema

➤ Various retail outlets

Case Study – Hotel in Mexico.

Pueblo Bonito Sunset Beach Hotel is located in Los Cabos (Southern Tip of Baja Peninsula)

➤ 5 star with 327 bedrooms

➤ 7 on site restaurants & bars

The hotel is operated by Pueblo Bonito Oceanfront Resorts & Spas.

Plaza Indonesia - Jakarta Retail mall provides:

• ~70,000 m2 of retail area.

• Over 250 retail units & food outlets.

The Grand Hyatt Jakarta.

• 450 hotel rooms and suites

• 7 on-site restaurants & bars

• 14 conference/meeting spaces

Project Example: Le Roy HS – Alabama, USA • Le Roy High school has around 830 students and

60 teachers. • It produces approximately 19,000 US gallons/day

wastewater (72m3/day).

HUBER smartMBR size 75 installed

to reduce environmental impact to

receiving stream

HUBER SE . www.huber.de

Wärmequelle Abwasser

Energy Rivers Run Below Our Feet

Lets start using them.

HUBER SE . www.huber.de

Abwasserproduzent (kommunal / industriell)

Kanal Pumpwerk Kläranlage Vorflut

Kommunal: 23 °C Industriell: 60+ °C

12-14°C 10-14°C 10-12°C

Abwassertemperaturen

HUBER SE . www.huber.de

Die Lösung: Das Huber ThermWin® - Verfahren

HUBER SE . www.huber.de

Huber ThermWin® - Winterthur, CH

Schachtsiebanlage Rok4 Vorsiebung – 6mm (Lochblech)

HUBER SE . www.huber.de

Huber ThermWin® - Winterthur, CH

Ansicht Pumpenschacht

2x Pumpe – 50 l/s

2 x Wärmetauscher RoWin BG 8

Thermische Entzugsleistung

Heizen / Kühlen: 480 kW / 600 kW

HUBER SE . www.huber.de

Huber ThermWin® - Winterthur, CH

Wärmepumpe

Heizleistung / Kühlleistung: 585 kW / 840 kW

HUBER SE . www.huber.de

Huber ThermWin® - Winterthur, CH

HUBER SE . www.huber.de

Heizleistung kommunal 40-250 kW

Heizleistung industriell 40kW-1MW

Kühlleistung: 40-500 kW

Automatische Selbstreinigung

Batch-Beschickung

Huber RoWin® - Abwasserwärmeübertrager

Huber RoWin® - Vor der Reinigung

HUBER SE . www.huber.de

Biofilm

Sedimente

Austrag der Sedimente durch eine Förderschnecke

autom. Reinigungsschlitten

Huber RoWin® - Während der Reinigung

HUBER SE . www.huber.de

HUBER SE . www.huber.de

Huber RoWin® Auto. Reinigungsvorrichtung

Gereinigtes Rohrmodul

Verschmutztes Rohrmodul

Gewährleistung eines konstant hohen k-Wertes!

HUBER SE . www.huber.de

Textilfabriken

Papierfabriken

Lebensmittelindustrie

Fleischverarbeitung

Reinigungsanlagen

Anwendungsfelder

Fernwärmenetze

Liegenschaften

In – House Lösungen

Kommunal Industrie

HUBER SE . www.huber.de

Realisierung

Anwendungen -

Industrie

Office Tower Switzerland

The system yields 480kW of heating & 840kW of cooling and operates with a Coefficient of Performance (COP) of approximately 5-6.

~100 Apartments - Germany

Comparison of energy sources

Heat recovery from wastewater

385,200

535,000

96,300

53,500

23,000

0

100000

200000

300000

400000

500000

600000

Ene

rgy

Inp

ut

[kW

h/a

]

Wastewater Heat Recovery Conventional

Hilfsenergie [kWh/a] Gas [kWh/a] Nutzenergie [kWh/a] Abwasserwärme [kWh/a]

72 % Umweltwärme

aus Abwasser

Comparison of CO2 emissions

Heat recovery from wastewater

14

140

0

20

40

60

80

100

120

140

CO

2 -

Emis

sio

ne

n [

t/a]

Wastewater Heat Recovery Conventional

Verlust der Energie an die Umwelt!

HUBER SE . www.huber.de

Industrielle Abwärme durch Prozesswasser

Huber RoWin® - Industrie

Vorwärmung von Prozesswasser

Abkühlung des Abwassers

Win-Win durch RoWin • Abflusstemperaturen reduzieren! • gesetzlichen Grenzwerte einhalten! • CO2 Emissionen reduzieren! • Geld sparen!

HUBER SE . www.huber.de

Huber RoWin® - Industrie Gerberei, AUT

Betriebsmodus 1 Abkühlen des Abwasser (gesetzl. Vorschrift) Betriebsmodus 2 Vorwärmen des Prozesswassers Abwassertemperatur: ca. 85°C therm. Entzugsleistung: ca. 500 kW

Aufstellung zwischen Fettabscheider und der Einleitung in die hauseigene Kläranlage

HUBER SE . www.huber.de

Industrielle Abwärme durch Prozesswasser

Abwasser Temperatur: ca. 80°C Abwasser: 2,5 l/s Kühlwasser Temperatur: 6,5°C

Einleittemperatur Abwasser: < 30°C (MIT HUBER RoWin)

0

50

100

150

200

250

300

350

400

450

500

15

20

25

30

35

40

45

0.00 1.00 2.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00

Wär

me

me

nge

[kW

]

Tem

pe

ratu

r [°

C]

Volumenstrom KW [l/s]

Austrittstemperatur / Wärmemenge

T (Kühlwasser) T (Abwasser) Wärmemenge

Huber RoWin® - Industrie Gerberei, AUT

HUBER SE . www.huber.de

Industrielle Abwärme durch Prozesswasser

Bestand Gasheizung Variante 1 RoWin Wärmeübertrager (inkl. Wärmepumpe) Allgemein Vorlauftemperatur 50°C Th. Entzugsleistung 500 kW Heizleistung 635 kW

Huber RoWin® - Industrie Gerberei, AUT

€-

€200,000

€400,000

€600,000

€800,000

€1,000,000

€1,200,000

€1,400,000

€1,600,000

0 1 2 3 4 5 6 7 8 9 10

Jahre

Variante 1 Bestand

Life-Cycle-Kosten Wärmerückgewinnung

Mit 3600 Betriebsstunden pro Jahr ergibt sich ein ROI (=Return of Invest) bereits nach 2 Jahren

Bzw. nach 7200 Betriebsstunden

HUBER SE . www.huber.de

Huber RoWin® - Lindenschmidt KG, DE

Simultanes Heizen und Kühlen einzelner Behandlungsstufen

1. Kühlung der biologischen Stufe 2. Ganzjähriges heizen der Öltanks therm. Entzugsleistung: 90 kW Heizleistung: 110 kW Besonderheit: Rohabwasser mit einem TS – Gehalt von ca. 3%

HUBER SE . www.huber.de

Huber RoWin® - Lindenschmidt KG, DE

Herausforderung Biologischer Abbau erwärmt das Belebungsbecken sehr stark

Herausforderung Öltank muss das gesamte Jahr beheizt werden

Die Lösung: HUBER RoWin

Kaltwasserersatz 100% Back-Up

Thank you for your Attention! Questions? Comments?

top related